-
Integrable Magnetic Fluid Hyperthermia Systems for 3D Magnetic Particle Imaging
Authors:
André Behrends,
Huimin Wei,
Alexander Neumann,
Thomas Friedrich,
Anna C. Bakenecker,
Matthias Graeser,
Thorsten M. Buzug
Abstract:
Background: Combining magnetic particle imaging (MPI) and magnetic fluid hyperthermia (MFH) offers the ability to perform localized hyperthermia and magnetic particle imaging-assisted ther-mometry of hyperthermia treatment. This allows precise regional selective heating inside the body without invasive interventions. In current MPI-MFH platforms, separate systems are used, which require object tra…
▽ More
Background: Combining magnetic particle imaging (MPI) and magnetic fluid hyperthermia (MFH) offers the ability to perform localized hyperthermia and magnetic particle imaging-assisted ther-mometry of hyperthermia treatment. This allows precise regional selective heating inside the body without invasive interventions. In current MPI-MFH platforms, separate systems are used, which require object transfer from one system to another. Here, we present the design, development and evaluation process for integrable MFH platforms, which extends a commercial MPI scanner with the functionality of MFH. Methods: The biggest issue of integrating magnetic fluid hyperthermia platforms into a magnetic par-ticle imaging system is the magnetic coupling of the devices, which induces high voltage in the imaging system, and is harming its components. In this paper we use a self-compensation approach derived from heuristic algorithms to protect the magnetic particle imaging scanner. The integrable platforms are evaluated regarding electrical and magnetic characteristics, cooling capability, field strength, the magnetic coupling to a replica of the magnetic particle imaging system's main solenoid and particle heating. Results: The MFH platforms generate suitable magnetic fields for magnetic heating of particles and are compatible with a commercial magnetic particle imaging scanner. In combination with the imaging system, selective heating with a gradient field and steerable heating positioning using the MPI focus fields are possible. Conclusion: The proposed MFH platforms serve as a therapeutic tool to unlock MFH functionality of a commercial magnetic particle imaging scanner, enabling its use in future preclinical trials of MPI-guided, spatially selective magnetic hyperthermia therapy.
△ Less
Submitted 21 September, 2023;
originally announced September 2023.
-
Deep convolutional neural networks to restore single-shot electron microscopy images
Authors:
I. Lobato,
T. Friedrich,
S. Van Aert
Abstract:
State-of-the-art electron microscopes such as scanning electron microscopes (SEM), scanning transmission electron microscopes (STEM) and transmission electron microscopes (TEM) have become increasingly sophisticated. However, the quality of experimental images is often hampered by stochastic and deterministic distortions arising from the instrument or its environment. These distortions can arise d…
▽ More
State-of-the-art electron microscopes such as scanning electron microscopes (SEM), scanning transmission electron microscopes (STEM) and transmission electron microscopes (TEM) have become increasingly sophisticated. However, the quality of experimental images is often hampered by stochastic and deterministic distortions arising from the instrument or its environment. These distortions can arise during any stage of the imaging process, including image acquisition, transmission, or visualization. In this paper, we will discuss the main sources of distortion in TEM and S(T)EM images, develop models to describe them and propose a method to correct these distortions using a convolutional neural network. We demonstrate the effectiveness of our approach on a variety of experimental images and show that it can significantly improve the signal-to-noise ratio resulting in an increase in the amount of quantitative structural information that can be extracted from the image. Overall, our findings provide a powerful framework for improving the quality of electron microscopy images and advancing the field of structural analysis and quantification in materials science and biology.
△ Less
Submitted 29 March, 2023;
originally announced March 2023.
-
Self-assembly of magnetic iron oxide nanoparticles into cuboidal superstructures
Authors:
Sabine Rosenfeldt,
Stephan Förster,
Thomas Friedrich,
Ingo Rehberg,
Birgit Weber
Abstract:
This chapter describes the synthesis and some characteristics of magnetic iron oxide nanoparticles, mainly nanocubes, and focus on their self-assembly into crystalline cuboids in dispersion. The influence of external magnetic fields, the concentration of particles, and the temperature on the assembly process is experimentally investigated.
This chapter describes the synthesis and some characteristics of magnetic iron oxide nanoparticles, mainly nanocubes, and focus on their self-assembly into crystalline cuboids in dispersion. The influence of external magnetic fields, the concentration of particles, and the temperature on the assembly process is experimentally investigated.
△ Less
Submitted 21 March, 2018;
originally announced March 2018.
-
Towards Picogram Detection of Superparamagnetic Iron-Oxide Particles Using a Gradiometric Receive Coil
Authors:
Matthias Gräser,
Tobias Knopp,
Patryk Szwargulski,
Thomas Friedrich,
Anselm von Gladiss,
Michael Kaul,
Kannan M Krishnan,
Harald Ittrich,
Gerhard Adam,
Thorsten M. Buzug
Abstract:
Superparamagnetic iron-oxide nanoparticles can be used in a variety of medical applications like vascular or targeted imaging. Magnetic particle imaging (MPI) is a promising tomographic imaging technique that allows visualizing the 3D nanoparticle distribution concentration in a non-invasive manner. The two main strengths of MPI are high temporal resolution and high sensitivity. While the first ha…
▽ More
Superparamagnetic iron-oxide nanoparticles can be used in a variety of medical applications like vascular or targeted imaging. Magnetic particle imaging (MPI) is a promising tomographic imaging technique that allows visualizing the 3D nanoparticle distribution concentration in a non-invasive manner. The two main strengths of MPI are high temporal resolution and high sensitivity. While the first has been proven in the assessment of dynamic processes like cardiac imaging, it is unknown how far the detection limit of MPI can be lowered. Within this work, we will present a highly sensitive gradiometric receive-coil unit combined with a noise-matching network tailored for the measurement of mice. The setup is capable of detecting 5 ng of iron in vitro at 2.14 sec acquisition time. In terms of iron concentration we are able to detect 156 μg/L marking the lowest value that has been reported for an MPI scanner so far. In vivo MPI mouse images of a 512 ng bolus at 21.5 ms acquisition time allow for capturing the flow of an intravenously injected tracer through the heart of a mouse. Since it has been rather difficult to compare detection limits across MPI publications we propose guidelines improving the comparability of future MPI studies.
△ Less
Submitted 5 May, 2017; v1 submitted 6 April, 2017;
originally announced April 2017.
-
Spherical sample holders to improve the susceptibility measurement of superparamagnetic materials
Authors:
Thomas Friedrich,
Tobias Lang,
Ingo Rehberg,
Reinhard Richter
Abstract:
The design of two custom sample holders with a spherical cavity for commercial vibrating sample magnetometer systems is described. For such cavities the magnetization M and the internal magnetic field Hi of a sample are both homogeneous. Consequently, the material parameter M(Hi) of a sample can be determined even for liquids and powders with a high magnetic susceptibility.
The design of two custom sample holders with a spherical cavity for commercial vibrating sample magnetometer systems is described. For such cavities the magnetization M and the internal magnetic field Hi of a sample are both homogeneous. Consequently, the material parameter M(Hi) of a sample can be determined even for liquids and powders with a high magnetic susceptibility.
△ Less
Submitted 18 July, 2012; v1 submitted 26 October, 2011;
originally announced October 2011.
-
A note on the magnetic spatial forcing of a ferrofluid layer
Authors:
Thomas Friedrich,
Adrian Lange,
Ingo Rehberg,
Reinhard Richter
Abstract:
We report on the response of a thin layer of ferrofluid to a spatially modulated magnetic field. This field is generated by means of a constant current in a special arrangement of aluminum wires. The full surface profile of the liquid layer is recorded by means of the absorption of X-rays. The outcome is analyzed particularly with regard to the magnetic self focusing effect under a deformable flui…
▽ More
We report on the response of a thin layer of ferrofluid to a spatially modulated magnetic field. This field is generated by means of a constant current in a special arrangement of aluminum wires. The full surface profile of the liquid layer is recorded by means of the absorption of X-rays. The outcome is analyzed particularly with regard to the magnetic self focusing effect under a deformable fluid layer.
△ Less
Submitted 20 June, 2011;
originally announced June 2011.
-
Magnetic traveling-stripe-forcing: enhanced transport in the advent of the Rosensweig instability
Authors:
Thomas Friedrich,
Ingo Rehberg,
Reinhard Richter
Abstract:
A new kind of contactless pum** mechanism is realized in a layer of ferrofluid via a spatio-temporally modulated magnetic field. The resulting pressure gradient leads to a liquid ramp, which is measured by means of X-rays. The transport mechanism works best if a resonance of the surface waves with the driving is achieved. The behavior can be understood semi-quantitatively by considering the magn…
▽ More
A new kind of contactless pum** mechanism is realized in a layer of ferrofluid via a spatio-temporally modulated magnetic field. The resulting pressure gradient leads to a liquid ramp, which is measured by means of X-rays. The transport mechanism works best if a resonance of the surface waves with the driving is achieved. The behavior can be understood semi-quantitatively by considering the magnetically influenced dispersion relation of the fluid.
△ Less
Submitted 23 April, 2010;
originally announced April 2010.
-
First Experimental Observation of Superscars in a Pseudointegrable Barrier Billiard
Authors:
E. Bogomolny,
B. Dietz,
T. Friedrich,
M. Miski-Oglu,
A. Richter,
F. Schaefer,
C. Schmit
Abstract:
With a perturbation body technique intensity distributions of the electric field strength in a flat microwave billiard with a barrier inside up to mode numbers as large as about 700 were measured. A method for the reconstruction of the amplitudes and phases of the electric field strength from those intensity distributions has been developed. Recently predicted superscars have been identified exp…
▽ More
With a perturbation body technique intensity distributions of the electric field strength in a flat microwave billiard with a barrier inside up to mode numbers as large as about 700 were measured. A method for the reconstruction of the amplitudes and phases of the electric field strength from those intensity distributions has been developed. Recently predicted superscars have been identified experimentally and - using the well known analogy between the electric field strength and the quantum mechanical wave function in a two-dimensional microwave billiard - their properties determined.
△ Less
Submitted 11 December, 2006;
originally announced December 2006.
-
Rabi Oscillations at Exceptional Points in Microwave Billiards
Authors:
B. Dietz,
T. Friedrich,
J. Metz,
M. Miski-Oglu,
A. Richter,
F. Schäfer,
C. A. Stafford
Abstract:
We experimentally investigated the decay behavior with time t of resonances near and at exceptional points, where two complex eigenvalues and also the associated eigenfunctions coalesce. The measurements were performed with a dissipative microwave billiard, whose shape depends on two parameters. The t^2-dependence predicted at the exceptional point on the basis of a two-state matrix model could…
▽ More
We experimentally investigated the decay behavior with time t of resonances near and at exceptional points, where two complex eigenvalues and also the associated eigenfunctions coalesce. The measurements were performed with a dissipative microwave billiard, whose shape depends on two parameters. The t^2-dependence predicted at the exceptional point on the basis of a two-state matrix model could be verified. Outside the exceptional point the predicted Rabi oscillations, also called quantum echoes in this context, were detected. To our knowledge this is the first time that quantum echoes related to exceptional points were observed experimentally.
△ Less
Submitted 21 December, 2006;
originally announced December 2006.