-
Mineral Detection of Neutrinos and Dark Matter 2024. Proceedings
Authors:
Sebastian Baum,
Patrick Huber,
Patrick Stengel,
Natsue Abe,
Daniel G. Ang,
Lorenzo Apollonio,
Gabriela R. Araujo,
Levente Balogh,
Pranshu Bhaumik Yilda Boukhtouchen,
Joseph Bramante,
Lorenzo Caccianiga,
Andrew Calabrese-Day,
Qing Chang,
Juan I. Collar,
Reza Ebadi,
Alexey Elykov,
Katherine Freese,
Audrey Fung,
Claudio Galelli,
Arianna E. Gleason,
Mariano Guerrero Perez,
Janina Hakenmüller,
Takeshi Hanyu,
Noriko Hasebe,
Shigenobu Hirose
, et al. (35 additional authors not shown)
Abstract:
The second "Mineral Detection of Neutrinos and Dark Matter" (MDvDM'24) meeting was held January 8-11, 2024 in Arlington, VA, USA, hosted by Virginia Tech's Center for Neutrino Physics. This document collects contributions from this workshop, providing an overview of activities in the field. MDvDM'24 was the second topical workshop dedicated to the emerging field of mineral detection of neutrinos a…
▽ More
The second "Mineral Detection of Neutrinos and Dark Matter" (MDvDM'24) meeting was held January 8-11, 2024 in Arlington, VA, USA, hosted by Virginia Tech's Center for Neutrino Physics. This document collects contributions from this workshop, providing an overview of activities in the field. MDvDM'24 was the second topical workshop dedicated to the emerging field of mineral detection of neutrinos and dark matter, following a meeting hosted by IFPU in Trieste, Italy in October 2022. Mineral detectors have been proposed for a wide variety of applications, including searching for dark matter, measuring various fluxes of astrophysical neutrinos over gigayear timescales, monitoring nuclear reactors, and nuclear disarmament protocols; both as paleo-detectors using natural minerals that could have recorded the traces of nuclear recoils for timescales as long as a billion years and as detectors recording nuclear recoil events on laboratory timescales using natural or artificial minerals. Contributions to this proceedings discuss the vast physics potential, the progress in experimental studies, and the numerous challenges lying ahead on the path towards mineral detection. These include a better understanding of the formation and annealing of recoil defects in crystals; identifying the best classes of minerals and, for paleo-detectors, understanding their geology; modeling and control of the relevant backgrounds; develo**, combining, and scaling up imaging and data analysis techniques; and many others. During the last years, MDvDM has grown rapidly and gained attention. Small-scale experimental efforts focused on establishing various microscopic readout techniques are underway at institutions in North America, Europe and Asia. We are looking ahead to an exciting future full of challenges to overcome, surprises to be encountered, and discoveries lying ahead of us.
△ Less
Submitted 2 May, 2024;
originally announced May 2024.
-
New Projections for Dark Matter Searches with Paleo-Detectors
Authors:
Sebastian Baum,
Thomas D. P. Edwards,
Katherine Freese,
Patrick Stengel
Abstract:
Paleo-detectors are a proposed experimental technique to search for dark matter (DM). In lieu of the conventional approach of operating a tonne-scale real-time detector to search for DM-induced nuclear recoils, paleo-detectors take advantage of small samples of naturally occurring rocks on Earth that have been deep underground ($\gtrsim 5$ km), accumulating nuclear damage tracks from recoiling nuc…
▽ More
Paleo-detectors are a proposed experimental technique to search for dark matter (DM). In lieu of the conventional approach of operating a tonne-scale real-time detector to search for DM-induced nuclear recoils, paleo-detectors take advantage of small samples of naturally occurring rocks on Earth that have been deep underground ($\gtrsim 5$ km), accumulating nuclear damage tracks from recoiling nuclei for $\mathcal{O}(1)$ Gyr. Modern microscopy techniques promise the capability to read out nuclear damage tracks with nanometer resolution in macroscopic samples. Thanks to their $\mathcal{O}(1)$ Gyr integration times, paleo-detectors could constitute nuclear recoil detectors with keV recoil energy thresholds and 100 kilotonne-yr exposures. This combination would allow paleo-detectors to probe DM-nucleon cross sections orders of magnitude below existing upper limits from conventional direct detection experiments. In this article, we use improved background modeling and a new spectral analysis technique to update the sensitivity forecast for paleo-detectors. We demonstrate the robustness of the sensitivity forecast to the (lack of) ancillary measurements of the age of the samples and the parameters controlling the backgrounds, systematic mismodeling of the spectral shape of the backgrounds, and the radiopurity of the mineral samples. Specifically, we demonstrate that even if the uranium concentration in paleo-detector samples is $10^{-8}$ (per weight), many orders of magnitude larger than what we expect in the most radiopure samples obtained from ultra basic rock or marine evaporite deposits, paleo-detectors could still probe DM-nucleon cross sections below current limits. For DM masses $\lesssim 10$ GeV/$c^2$, the sensitivity of paleo-detectors could still reach down all the way to the conventional neutrino floor in a Xe-based direct detection experiment.
△ Less
Submitted 11 June, 2021;
originally announced June 2021.
-
Paleo-detectors: Searching for Dark Matter with Ancient Minerals
Authors:
Andrzej K. Drukier,
Sebastian Baum,
Katherine Freese,
Maciej Górski,
Patrick Stengel
Abstract:
We explore paleo-detectors as an approach to the direct detection of Weakly Interacting Massive Particle (WIMP) dark matter radically different from conventional detectors. Instead of instrumenting a (large) target mass in a laboratory in order to observe WIMP-induced nuclear recoils in real time, the approach is to examine ancient minerals for traces of WIMP-nucleus interactions recorded over tim…
▽ More
We explore paleo-detectors as an approach to the direct detection of Weakly Interacting Massive Particle (WIMP) dark matter radically different from conventional detectors. Instead of instrumenting a (large) target mass in a laboratory in order to observe WIMP-induced nuclear recoils in real time, the approach is to examine ancient minerals for traces of WIMP-nucleus interactions recorded over timescales as large as 1 Gyr. Here, we discuss the paleo-detector proposal in detail, including background sources and possible target materials. In order to suppress backgrounds induced by radioactive contaminants such as uranium, we propose to use minerals found in marine evaporites or in ultra-basic rocks. We estimate the sensitivity of paleo-detectors to spin-independent and spin-dependent WIMP-nucleus interactions. The sensitivity to low-mass WIMPs with masses $m_χ\lesssim 10$ GeV extends to WIMP-nucleon cross sections many orders of magnitude smaller than current upper limits. For heavier WIMPs with masses $m_χ\gtrsim 30$ GeV cross sections a factor of a few to $\sim 100$ smaller than current upper limits can be probed by paleo-detectors.
△ Less
Submitted 27 February, 2019; v1 submitted 16 November, 2018;
originally announced November 2018.
-
280 GHz Focal Plane Unit Design and Characterization for the SPIDER-2 Suborbital Polarimeter
Authors:
A. S. Bergman,
P. A. R. Ade,
S. Akers,
M. Amiri,
J. A. Austermann,
J. A. Beall,
D. T. Becker,
S. J. Benton,
J. J. Bock,
J. R. Bond,
S. A. Bryan,
H. C. Chiang,
C. R. Contaldi,
R. S Domagalski,
O. Doré,
S. M. Duff,
A. J. Duivenvoorden,
H. K. Eriksen,
M. Farhang,
J. P. Filippini,
L. M. Fissel,
A. A. Fraisse,
K. Freese,
M. Galloway,
A. E. Gambrel
, et al. (54 additional authors not shown)
Abstract:
We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mod…
▽ More
We describe the construction and characterization of the 280 GHz bolometric focal plane units (FPUs) to be deployed on the second flight of the balloon-borne SPIDER instrument. These FPUs are vital to SPIDER's primary science goal of detecting or placing an upper limit on the amplitude of the primordial gravitational wave signature in the cosmic microwave background (CMB) by constraining the B-mode contamination in the CMB from Galactic dust emission. Each 280 GHz focal plane contains a 16 x 16 grid of corrugated silicon feedhorns coupled to an array of aluminum-manganese transition-edge sensor (TES) bolometers fabricated on 150 mm diameter substrates. In total, the three 280 GHz FPUs contain 1,530 polarization sensitive bolometers (765 spatial pixels) optimized for the low loading environment in flight and read out by time-division SQUID multiplexing. In this paper we describe the mechanical, thermal, and magnetic shielding architecture of the focal planes and present cryogenic measurements which characterize yield and the uniformity of several bolometer parameters. The assembled FPUs have high yields, with one array as high as 95% including defects from wiring and readout. We demonstrate high uniformity in device parameters, finding the median saturation power for each TES array to be ~3 pW at 300 mK with a less than 6% variation across each array at one standard deviation. These focal planes will be deployed alongside the 95 and 150 GHz telescopes in the SPIDER-2 instrument, slated to fly from McMurdo Station in Antarctica in December 2018.
△ Less
Submitted 22 November, 2017; v1 submitted 11 November, 2017;
originally announced November 2017.
-
New class of biological detectors for WIMPs
Authors:
Andrzej K. Drukier,
Charles Cantor,
Mark Chonofsky,
George M. Church,
Robert L. Fagaly,
Katherine Freese,
Alejandro Lopez,
Takeshi Sano,
Christopher Savage,
Wesley P. Wong
Abstract:
Weakly Interacting Massive Particles (WIMPs) may constitute a large fraction of the matter in the Universe. There are excess events in the data of DAMA/LIBRA, CoGeNT, CRESST-II, and recently CDMS-Si, which could be consistent with WIMP masses of approximately 10 GeV/c2. However, for MDM > 10 GeV/c2 null results of the CDMS-Ge, XENON, and LUX detectors may be in tension with the potential detection…
▽ More
Weakly Interacting Massive Particles (WIMPs) may constitute a large fraction of the matter in the Universe. There are excess events in the data of DAMA/LIBRA, CoGeNT, CRESST-II, and recently CDMS-Si, which could be consistent with WIMP masses of approximately 10 GeV/c2. However, for MDM > 10 GeV/c2 null results of the CDMS-Ge, XENON, and LUX detectors may be in tension with the potential detections for certain dark matter scenarios and assuming a certain light response.
We propose the use of a new class of biological dark matter (DM) detectors to further examine this light dark matter hypothesis, taking advantage of new signatures with low atomic number targets, Two types of biological DM detectors are discussed here: DNA-based detectors and enzymatic reactions (ER) based detectors. In the case of DNA-based detectors, we discuss a new implementation. In the case of ER detectors, there are four crucial phases of the detection process: a) change of state due to energy deposited by a particle; b) amplification due to the release of energy derived from the action of an enzyme on its substrate; c) sustainable but non-explosive enzymatic reaction; d) self-termination due to the denaturation of the enzyme, when the temperature is raised. This paper provides information of how to design as well as optimize these four processes.
△ Less
Submitted 2 July, 2015; v1 submitted 31 March, 2014;
originally announced March 2014.
-
New Dark Matter Detector using Nanoscale Explosives
Authors:
Alejandro Lopez,
Andrzej Drukier,
Katherine Freese,
Cagliyan Kurdak,
Gregory Tarle
Abstract:
We present nanoscale explosives as a novel type of dark matter detector and study the ignition properties. When a Weakly Interacting Massive Particle WIMP from the Galactic Halo elastically scatters off of a nucleus in the detector, the small amount of energy deposited can trigger an explosion. For specificity, this paper focuses on a type of two-component explosive known as a nanothermite, consis…
▽ More
We present nanoscale explosives as a novel type of dark matter detector and study the ignition properties. When a Weakly Interacting Massive Particle WIMP from the Galactic Halo elastically scatters off of a nucleus in the detector, the small amount of energy deposited can trigger an explosion. For specificity, this paper focuses on a type of two-component explosive known as a nanothermite, consisting of a metal and an oxide in close proximity. When the two components interact they undergo a rapid exothermic reaction --- an explosion. As a specific example, we consider metal nanoparticles of 5 nm radius embedded in an oxide. One cell contains more than a few million nanoparticles, and a large number of cells adds up to a total of 1 kg detector mass. A WIMP interacts with a metal nucleus of the nanoparticles, depositing enough energy to initiate a reaction at the interface between the two layers. When one nanoparticle explodes it initiates a chain reaction throughout the cell. A number of possible thermite materials are studied. Excellent background rejection can be achieved because of the nanoscale granularity of the detector: whereas a WIMP will cause a single cell to explode, backgrounds will instead set off multiple cells.
If the detector operates at room temperature, we find that WIMPs with masses above 100 GeV (or for some materials above 1 TeV) could be detected; they deposit enough energy ($>$10 keV) to cause an explosion. When operating cryogenically at liquid nitrogen or liquid helium temperatures, the nano explosive WIMP detector can detect energy deposits as low as 0.5 keV, making the nano explosive detector more sensitive to very light $<$10 GeV WIMPs, better than other dark matter detectors.
△ Less
Submitted 14 April, 2014; v1 submitted 31 March, 2014;
originally announced March 2014.
-
New Dark Matter Detectors using DNA or RNA for Nanometer Tracking
Authors:
Andrzej Drukier,
Katherine Freese,
Alejandro Lopez,
David Spergel,
Charles Cantor,
George Church,
Takeshi Sano
Abstract:
Weakly Interacting Massive Particles (WIMPs) may constitute most of the matter in the Universe. The ability to detect the directionality of recoil nuclei will considerably facilitate detection of WIMPs. In this paper we propose a novel type of dark matter detector: detectors made of DNA or RNA could provide nanometer resolution for tracking, an energy threshold of 0.5 keV, and can operate at room…
▽ More
Weakly Interacting Massive Particles (WIMPs) may constitute most of the matter in the Universe. The ability to detect the directionality of recoil nuclei will considerably facilitate detection of WIMPs. In this paper we propose a novel type of dark matter detector: detectors made of DNA or RNA could provide nanometer resolution for tracking, an energy threshold of 0.5 keV, and can operate at room temperature. When a WIMP from the Galactic Halo elastically scatters off of a nucleus in the detector, the recoiling nucleus then traverses hundreds of strings of single stranded nucleic acids (ssNA) with known base sequences and severs ssNA strands along its trajectory. The location of the break can be identified by amplifying and identifying the segments of cut ssNA using techniques well known to biologists. Thus the path of the recoiling nucleus can be tracked to nanometer accuracy. In one such detector concept, the transducers are nanometer-thick Au-foils of 1m x 1m, and the direction of recoiling nuclei is measured by "NA Tracking Chamber" consisting of ordered array of ssNA strands. Polymerase Chain Reaction (PCR) and ssNA sequencing are used to read-out the detector. The proposed detector is smaller and cheaper than other alternatives: 1 kg of gold and 0.1 to 4 kg of ssNA (depending on length and strand density), packed into 0.01m$^3$, can be used to study 10 GeV WIMPs. A variety of other detector target elements could be used in this detector to optimize for different WIMP masses and to identify WIMP properties. By leveraging advances in molecular biology, we aim to achieve about 1,000-fold better spatial resolution than in conventional WIMP detectors at reasonable cost.
△ Less
Submitted 11 January, 2015; v1 submitted 28 June, 2012;
originally announced June 2012.