Towards clinical translation of deep-learning based classification of DSA image sequences for stroke treatment
Authors:
Timo Baumgärtner,
Benjamin J. Mittmann,
Till Malzacher,
Johannes Roßkopf,
Michael Braun,
Bernd Schmitz,
Alfred M. Franz
Abstract:
In the event of stroke, a catheter-guided procedure (thrombectomy) is used to remove blood clots. Feasibility of machine learning based automatic classifications for thrombus detection on digital substraction angiography (DSA) sequences has been demonstrated. It was however not used live in the clinic, yet. We present an open-source tool for automatic thrombus classification and test it on three s…
▽ More
In the event of stroke, a catheter-guided procedure (thrombectomy) is used to remove blood clots. Feasibility of machine learning based automatic classifications for thrombus detection on digital substraction angiography (DSA) sequences has been demonstrated. It was however not used live in the clinic, yet. We present an open-source tool for automatic thrombus classification and test it on three selected clinical cases regarding functionality and classification runtime. With our trained model all large vessel occlusions in the M1 segment were correctly classified. One small remaining M3 thrombus was not detected. Runtime was in the range from 1 to 10 seconds depending on the used hardware. We conclude that our open-source software tool enables clinical staff to classify DSA sequences in (close to) realtime and can be used for further studies in clinics.
△ Less
Submitted 23 May, 2023;
originally announced June 2023.
-
An open-source tool for automated planning of overlap** ablation zones for percutaneous renal tumor treatment
Authors:
A. M. Franz,
B. J. Mittmann,
J. Roeser,
B. Schmidberger,
M. Meinke,
P. L. Pereira,
H. U. Kauczor,
G. M. Richter,
C. M. Sommer
Abstract:
Percutaneous thermal ablation is a minimally-invasive treatment option for renal cancer. To treat larger tumours, multiple overlap** ablations zones are required. Arrangements with a low number of ablation zones but coverage of the whole tumour volume are challenging to find for physicians. In this work, an open-source software tool with a new planning approach based on the automatic selection f…
▽ More
Percutaneous thermal ablation is a minimally-invasive treatment option for renal cancer. To treat larger tumours, multiple overlap** ablations zones are required. Arrangements with a low number of ablation zones but coverage of the whole tumour volume are challenging to find for physicians. In this work, an open-source software tool with a new planning approach based on the automatic selection from a large number of randomized geometrical arrangements is presented. Two uncertainty parameters are introduced to account for tissue shrinking and tolerance of non-ablated tumour volume. For seven clinical renal T1a, T1b and T2a tumours, ablation plans were proposed by the software. All proposals are comparable to manual plans of an experienced physician with regard to the number of required ablation zones.
△ Less
Submitted 19 December, 2019;
originally announced December 2019.
-
Navigated interventions in the head and neck area: standardized assessment of a new handy field generator
Authors:
Benjamin J. Mittmann,
Alexander Seitel,
Lena Maier-Hein,
Alfred M. Franz
Abstract:
Electromagnetic (EM) tracking enables localization of surgical instruments within the magnetic field emitted by an EM field generator (FG). Usually, the larger a FG is, the larger its tracking volume is. However, the company NDI (Northern Digital Inc., Waterloo, ON, Canada) recently introduced the Planar 10-11 FG, which combines a compact construction (97mm x 112mm x 31mm) with a relatively large,…
▽ More
Electromagnetic (EM) tracking enables localization of surgical instruments within the magnetic field emitted by an EM field generator (FG). Usually, the larger a FG is, the larger its tracking volume is. However, the company NDI (Northern Digital Inc., Waterloo, ON, Canada) recently introduced the Planar 10-11 FG, which combines a compact construction (97mm x 112mm x 31mm) with a relatively large, cylindrical tracking volume (diameter: 340mm, height: 340mm). Using the standardized assessment protocol of Hummel et al., the FG was tested with regard to its tracking accuracy and to its robustness with respect to external sources of disturbance. The mean positional error (5cm distance metric according to Hummel protocol) was 0.59mm, with a mean jitter of 0.26mm in the standard setup. The mean orientational error was found to be 0.10°. The highest positional error (4.82mm) due to metallic sources of disturbance was caused by the steel SST 303. In contrast, steel SST 416 caused the lowest positional error (0.10mm). Overall, the Planar 10-11 FG tends to achieve better tracking accuracy results compared to other NDI FGs. Due to its compact construction and portability, the FG could contribute to increased clinical use of EM tracking systems.
△ Less
Submitted 24 March, 2019;
originally announced March 2019.
-
Open-source Tracked Ultrasound with Anser EMT
Authors:
Alfred Michael Franz,
Herman Alexander Jaeger,
Alexander Seitel,
Padraig Cantillon-Murphy,
Lena Maier-Hein
Abstract:
Image-guided Interventions (IGT) have shown a huge potential to improve medical procedures or even allow for new treatment options. Most ultrasound(US)-based IGT systems use electromagnetic (EM) tracking for localizing US probes and instruments. However, EM tracking is not always reliable in clinical settings because the EM field can be disturbed by medical equipment. So far, most researchers used…
▽ More
Image-guided Interventions (IGT) have shown a huge potential to improve medical procedures or even allow for new treatment options. Most ultrasound(US)-based IGT systems use electromagnetic (EM) tracking for localizing US probes and instruments. However, EM tracking is not always reliable in clinical settings because the EM field can be disturbed by medical equipment. So far, most researchers used and studied commercial EM trackers with their IGT systems which in turn limited the possibilities to customize the trackers in order minimize distortions and make the systems robust for clinical use. In light of current good scientific practice initiatives that increasingly request research to publish the source code corresponding to a paper, the aim of this work was to test the feasibility of using the open-source EM tracker Anser EMT for localizing US probes in a clinical US suite for the first time. The standardized protocol of Hummel et al. yielded a jitter of 0.1$\pm$0.1 mm and a position error of 1.1$\pm$0.7 mm, which is comparable to 0.1 mm and 1.0 mm of a commercial NDI Aurora system. The rotation error of Anser EMT was 0.15$\pm$0.16°, which is lower than at least 0.4° for the commercial tracker. We consider tracked US as feasible with Anser EMT if an accuracy of 1-2 mm is sufficient for a specific application.
△ Less
Submitted 15 March, 2019;
originally announced March 2019.
-
Design and Beam Test Results for the sPHENIX Electromagnetic and Hadronic Calorimeter Prototypes
Authors:
C. A. Aidala,
V. Bailey,
S. Beckman,
R. Belmont,
C. Biggs,
J. Blackburn,
S. Boose,
M. Chiu,
M. Connors,
E. Desmond,
A. Franz,
J. S. Haggerty,
X. He,
M. M. Higdon,
J. Huang,
K. Kauder,
E. Kistenev,
J. LaBounty,
J. G. Lajoie,
M. Lenz,
W. Lenz,
S. Li,
V. R. Loggins,
E. J. Mannel,
T. Majoros
, et al. (25 additional authors not shown)
Abstract:
The super Pioneering High Energy Nuclear Interaction eXperiment (sPHENIX) at the Relativistic Heavy Ion Collider (RHIC) will perform high precision measurements of jets and heavy flavor observables for a wide selection of nuclear collision systems, elucidating the microscopic nature of strongly interacting matter ranging from nucleons to the strongly coupled quark-gluon plasma. A prototype of the…
▽ More
The super Pioneering High Energy Nuclear Interaction eXperiment (sPHENIX) at the Relativistic Heavy Ion Collider (RHIC) will perform high precision measurements of jets and heavy flavor observables for a wide selection of nuclear collision systems, elucidating the microscopic nature of strongly interacting matter ranging from nucleons to the strongly coupled quark-gluon plasma. A prototype of the sPHENIX calorimeter system was tested at the Fermilab Test Beam Facility as experiment T-1044 in the spring of 2016. The electromagnetic calorimeter (EMCal) prototype is composed of scintillating fibers embedded in a mixture of tungsten powder and epoxy. The hadronic calorimeter (HCal) prototype is composed of tilted steel plates alternating with plastic scintillator. Results of the test beam reveal the energy resolution for electrons in the EMCal is $2.8\%\oplus~15.5\%/\sqrt{E}$ and the energy resolution for hadrons in the combined EMCal plus HCal system is $13.5\%\oplus 64.9\%/\sqrt{E}$. These results demonstrate that the performance of the proposed calorimeter system satisfies the sPHENIX specifications.
△ Less
Submitted 16 December, 2018; v1 submitted 5 April, 2017;
originally announced April 2017.
-
A Study of a Mini-drift GEM Tracking Detector
Authors:
B. Azmoun,
B. DiRuzza,
A. Franz,
A. Kiselev,
R. Pak,
M. Phipps,
M. L. Purschke,
C. Woody
Abstract:
A GEM tracking detector with an extended drift region has been studied as part of an effort to develop new tracking detectors for future experiments at RHIC and for the Electron Ion Collider that is being planned for BNL or JLAB. The detector consists of a triple GEM stack with a small drift region that was operated in a mini TPC type configuration. Both the position and arrival time of the charge…
▽ More
A GEM tracking detector with an extended drift region has been studied as part of an effort to develop new tracking detectors for future experiments at RHIC and for the Electron Ion Collider that is being planned for BNL or JLAB. The detector consists of a triple GEM stack with a small drift region that was operated in a mini TPC type configuration. Both the position and arrival time of the charge deposited in the drift region were measured on the readout plane which allowed the reconstruction of a short vector for the track traversing the chamber. The resulting position and angle information from the vector could then be used to improve the position resolution of the detector for larger angle tracks, which deteriorates rapidly with increasing angle for conventional GEM tracking detectors using only charge centroid information. Two types of readout planes were studied. One was a COMPASS style readout plane with 400 micron pitch XY strips and the other consisted of 2x10mm2 chevron pads. The detector was studied in test beams at Fermilab and CERN, along with additional measurements in the lab, in order to determine its position and angular resolution for incident track angles up to 45 degrees. Several algorithms were studied for reconstructing the vector using the position and timing information in order to optimize the position and angular resolution of the detector for the different readout planes. Applications for large angle tracking detectors at RHIC and EIC are also discussed.
△ Less
Submitted 6 October, 2015;
originally announced October 2015.