Beam Test Results for New Full-scale GEM Prototypes for a Future Upgrade of the CMS High-eta Muon System
Authors:
D. Abbaneo,
M. Abbrescia,
C. Armagnaud,
P. Aspell,
Y. Assran,
Y. Ban,
S. Bally,
L. Benussi,
U. Berzano,
S. Bianco,
J. Bos,
K. Bunkowski,
J. Cai,
J. P. Chatelain,
J. Christiansen,
S. Colafranceschi,
A. Colaleo,
A. Conde Garcia,
E. David,
G. de Robertis,
R. De Oliveira,
S. Duarte Pinto,
S. Ferry,
F. Formenti,
L. Franconi
, et al. (34 additional authors not shown)
Abstract:
The CMS GEM collaboration is considering Gas Electron Multipliers (GEMs) for upgrading the CMS forward muon system in the 1.5<|eta|<2.4 endcap region. GEM detectors can provide precision tracking and fast trigger information. They would improve the CMS muon trigger and muon momentum resolution and provide missing redundancy in the high-eta region. Employing a new faster construction and assembly t…
▽ More
The CMS GEM collaboration is considering Gas Electron Multipliers (GEMs) for upgrading the CMS forward muon system in the 1.5<|eta|<2.4 endcap region. GEM detectors can provide precision tracking and fast trigger information. They would improve the CMS muon trigger and muon momentum resolution and provide missing redundancy in the high-eta region. Employing a new faster construction and assembly technique, we built four full-scale Triple-GEM muon detectors for the inner ring of the first muon endcap station. We plan to install these or further improved versions in CMS during the first long LHC shutdown in 2013/14 for continued testing. These detectors are designed for the stringent rate and resolution requirements in the increasingly hostile environments expected at CMS after the second long LHC shutdown in 2018/19. The new prototypes were studied in muon/pion beams at the CERN SPS. We discuss our experience with constructing the new full-scale production prototypes and present preliminary performance results from the beam test. We also tested smaller Triple-GEM prototypes with zigzag readout strips with 2 mm pitch in these beams and measured a spatial resolution of 73 microns. This readout offers a potential reduction of channel count and consequently electronics cost for this system while maintaining high spatial resolution.
△ Less
Submitted 16 November, 2012;
originally announced November 2012.
-
Infrastructure for Detector Research and Development towards the International Linear Collider
Authors:
J. Aguilar,
P. Ambalathankandy,
T. Fiutowski,
M. Idzik,
Sz. Kulis,
D. Przyborowski,
K. Swientek,
A. Bamberger,
M. Köhli,
M. Lupberger,
U. Renz,
M. Schumacher,
Andreas Zwerger,
A. Calderone,
D. G. Cussans,
H. F. Heath,
S. Mandry,
R. F. Page,
J. J. Velthuis,
D. Attié,
D. Calvet,
P. Colas,
X. Coppolani,
Y. Degerli,
E. Delagnes
, et al. (252 additional authors not shown)
Abstract:
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras…
▽ More
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.
△ Less
Submitted 23 January, 2012;
originally announced January 2012.
-
Construction and Performance of Large-Area Triple-GEM Prototypes for Future Upgrades of the CMS Forward Muon System
Authors:
M. Tytgat,
A. Marinov,
N. Zaganidis,
Y. Ban,
J. Cai,
H. Teng,
A. Mohapatra,
T. Moulik,
M. Abbrescia,
A. Colaleo,
G. de Robertis,
F. Loddo,
M. Maggi,
S. Nuzzo,
S. A. Tupputi,
L. Benussi,
S. Bianco,
S. Colafranceschi,
D. Piccolo,
G. Raffone,
G. Saviano,
M. G. Bagliesi,
R. Cecchi,
G. Magazzu,
E. Oliveri
, et al. (34 additional authors not shown)
Abstract:
At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-ηregion. An international collaboration is investigating the possibility of covering the 1.6 < |η| < 2.4 region of the muon endcaps with large-area triple-GEM detectors. Given their good spatial resolution, high rate capability, and radiation hardness, these micro-pattern gas dete…
▽ More
At present, part of the forward RPC muon system of the CMS detector at the CERN LHC remains uninstrumented in the high-ηregion. An international collaboration is investigating the possibility of covering the 1.6 < |η| < 2.4 region of the muon endcaps with large-area triple-GEM detectors. Given their good spatial resolution, high rate capability, and radiation hardness, these micro-pattern gas detectors are an appealing option for simultaneously enhancing muon tracking and triggering capabilities in a future upgrade of the CMS detector. A general overview of this feasibility study will be presented. The design and construction of small (10\times10 cm2) and full-size trapezoidal (1\times0.5 m2) triple-GEM prototypes will be described. During detector assembly, different techniques for stretching the GEM foils were tested. Results from measurements with x-rays and from test beam campaigns at the CERN SPS will be shown for the small and large prototypes. Preliminary simulation studies on the expected muon reconstruction and trigger performances of this proposed upgraded muon system will be reported.
△ Less
Submitted 30 November, 2011;
originally announced November 2011.
-
Test beam results of the GE1/1 prototype for a future upgrade of the CMS high-$η$ muon system
Authors:
D. Abbaneo,
M. Abbrescia,
C. Armagnaud,
P. Aspell,
M. G. Bagliesi,
Y. Ban,
S. Bally,
L. Benussi,
U. Berzano,
S. Bianco,
J. Bos,
K. Bunkowski,
J. Cai,
R. Cecchi,
J. P. Chatelain,
J. Christiansen,
S. Colafranceschi,
A. Colaleo,
A. Conde Garcia,
E. David,
G. de Robertis,
R. De Oliveira,
S. Duarte Pinto,
S. Ferry,
F. Formenti
, et al. (33 additional authors not shown)
Abstract:
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| η|<2.4$ endcap region. With a sufficiently fine segmentation GEMs can provide precision tracking as well as fast trigger information. The main objective is to contribute to the improvement of the CMS muon trigger. The const…
▽ More
Gas Electron Multipliers (GEM) are an interesting technology under consideration for the future upgrade of the forward region of the CMS muon system, specifically in the $1.6<| η|<2.4$ endcap region. With a sufficiently fine segmentation GEMs can provide precision tracking as well as fast trigger information. The main objective is to contribute to the improvement of the CMS muon trigger. The construction of large-area GEM detectors is challenging both from the technological and production aspects. In view of the CMS upgrade we have designed and built the largest full-size Triple-GEM muon detector, which is able to meet the stringent requirements given the hostile environment at the high-luminosity LHC. Measurements were performed during several test beam campaigns at the CERN SPS in 2010 and 2011. The main issues under study are efficiency, spatial resolution and timing performance with different inter-electrode gap configurations and gas mixtures. In this paper results of the performance of the prototypes at the beam tests will be discussed.
△ Less
Submitted 30 November, 2011; v1 submitted 21 November, 2011;
originally announced November 2011.
-
The CAST Time Projection Chamber
Authors:
D. Autiero,
B. Beltran,
J. M. Carmona,
S. Cébrian,
E. Chesi,
M. Davenport,
M. Delattre,
L. Di Lella,
F. Formenti,
I. G. Irastorza,
H. Gomez,
M. Hasinoff,
B. Lakić,
G. Luzón,
J. Morales,
L. Musa,
A. Ortiz,
A. Placci,
A. Rodriguez,
J. Ruz,
J. A. Villar,
K. Zioutas
Abstract:
One of the three X-ray detectors of the CAST experiment searching for solar axions is a Time Projection Chamber (TPC) with a multi-wire proportional counter (MWPC) as a readout structure. Its design has been optimized to provide high sensitivity to the detection of the low intensity X-ray signal expected in the CAST experiment. A low hardware threshold of 0.8 keV is safely set during normal data…
▽ More
One of the three X-ray detectors of the CAST experiment searching for solar axions is a Time Projection Chamber (TPC) with a multi-wire proportional counter (MWPC) as a readout structure. Its design has been optimized to provide high sensitivity to the detection of the low intensity X-ray signal expected in the CAST experiment. A low hardware threshold of 0.8 keV is safely set during normal data taking periods, and the overall efficiency for the detection of photons coming from conversion of solar axions is 62 %. Shielding has been installed around the detector, lowering the background level to 4.10 x 10^-5 counts/cm^2/s/keV between 1 and 10 keV. During phase I of the CAST experiment the TPC has provided robust and stable operation, thus contributing with a competitive result to the overall CAST limit on axion-photon coupling and mass.
△ Less
Submitted 22 February, 2007;
originally announced February 2007.