-
Dual-comb Spectroscopy of Ammonia Formation in Non-thermal Plasmas
Authors:
Ibrahim Sadiek,
Adam J. Fleisher,
Jakob Hayden,
Xinyi Huang,
Andreas Hugi,
Richard Engeln,
Norbert Lang,
Jean-Pierre H. van Helden
Abstract:
Plasma-activated chemical transformations promise the efficient synthesis of salient chemical products. However, the reaction pathways that lead to desirable products are often unknown, and key quantum-state-resolved information regarding the involved molecular species is lacking. Here we use quantum cascade laser dual-comb spectroscopy (QCL-DCS) to probe plasma-activated NH$_3$ generation with ro…
▽ More
Plasma-activated chemical transformations promise the efficient synthesis of salient chemical products. However, the reaction pathways that lead to desirable products are often unknown, and key quantum-state-resolved information regarding the involved molecular species is lacking. Here we use quantum cascade laser dual-comb spectroscopy (QCL-DCS) to probe plasma-activated NH$_3$ generation with rotational and vibrational state resolution, quantifying state-specific number densities via broadband spectral analysis. The measurements reveal unique translational, rotational and vibrational temperatures for NH$_3$ products, indicative of a highly reactive, non-thermal environment. Ultimately, we postulate on the energy transfer mechanisms that explain trends in temperatures and number densities observed for NH$_3$ generated in low-pressure nitrogen-hydrogen (N$_2$-H$_2$) plasmas.
△ Less
Submitted 8 December, 2023;
originally announced December 2023.
-
Dual electro-optic frequency comb photonic thermometry
Authors:
Adam J. Fleisher,
Zeeshan Ahmed,
Tobias Herman,
Matthew R. Hartings
Abstract:
We report a precision realization of photonic thermometry using dual-comb spectroscopy to interrogate a $π$-phase-shifted fiber Bragg grating. We achieve read-out stability of 7.5 mK at 1 s and resolve temperature changes of similar magnitude--sufficient for most industrial applications. Our dual-comb approach enables rapid sensing of dynamic temperature, and our scalable and reconfigurable electr…
▽ More
We report a precision realization of photonic thermometry using dual-comb spectroscopy to interrogate a $π$-phase-shifted fiber Bragg grating. We achieve read-out stability of 7.5 mK at 1 s and resolve temperature changes of similar magnitude--sufficient for most industrial applications. Our dual-comb approach enables rapid sensing of dynamic temperature, and our scalable and reconfigurable electro-optic generation scheme enables a broad sensing range without laser tuning. Reproducibility on the International Temperature Scale of 1990 is tested, and ultimately limited by the frequency reference and check-thermometer stability. Our demonstration opens the door for a universal interrogator deployable to multiple photonic devices in parallel. Applications include on-chip measurements to simultaneously evaluate quantities like temperature, pressure, humidity, magnetic field and radiation dose.
△ Less
Submitted 8 December, 2022;
originally announced December 2022.
-
Mid-infrared supermirrors with finesse exceeding 400 000
Authors:
G. -W. Truong,
L. W. Perner,
D. M. Bailey,
G. Winkler,
S. B. Cataño-Lopez,
V. J. Wittwer,
T. Sudmeyer,
C. Nguyen,
D. Follman,
A. J. Fleisher,
O. H. Heckl,
G. D. Cole
Abstract:
For trace gas sensing and precision spectroscopy, optical cavities incorporating low-loss mirrors are indispensable for path length and optical intensity enhancement. Optical interference coatings in the visible and near-infrared (NIR) spectral regions have achieved total optical losses below 2 parts per million (ppm), enabling a cavity finesse in excess of 1 million. However, such advancements ha…
▽ More
For trace gas sensing and precision spectroscopy, optical cavities incorporating low-loss mirrors are indispensable for path length and optical intensity enhancement. Optical interference coatings in the visible and near-infrared (NIR) spectral regions have achieved total optical losses below 2 parts per million (ppm), enabling a cavity finesse in excess of 1 million. However, such advancements have been lacking in the mid-infrared (MIR), despite substantial scientific interest. Here, we demonstrate a significant breakthrough in high-performance MIR mirrors, reporting substrate-transferred single-crystal interference coatings capable of cavity finesse values from 200 000 to 400 000 near 4.5 um, with excess optical losses (scatter and absorption) below 5 ppm. In a first proof-of-concept demonstration, we achieve the lowest noise-equivalent absorption in a linear cavity ring-down spectrometer normalized by cavity length. This substantial improvement in performance will unlock a rich variety of MIR applications for atmospheric transport and environmental sciences, detection of fugitive emissions, process gas monitoring, breath-gas analysis, and verification of biogenic fuels and plastics.
△ Less
Submitted 31 July, 2023; v1 submitted 14 September, 2022;
originally announced September 2022.
-
Dual-comb cavity ring-down spectroscopy
Authors:
D. Lisak,
D. Charczun,
A. Nishiyama,
T. Voumard,
T. Wildi,
G. Kowzan,
V. Brasch,
T. Herr,
A. J. Fleisher,
J. T. Hodges,
R. Ciuryło,
A. Cygan,
P. Masłowski
Abstract:
Cavity ring-down spectroscopy is a ubiquitous optical method used to study light-matter interactions with high resolution, sensitivity and accuracy. However, it has never been performed with the multiplexing advantages of direct frequency comb spectroscopy without sacrificing orders of magnitude of resolution. We present dual-comb cavity ring-down spectroscopy (DC-CRDS) based on the parallel heter…
▽ More
Cavity ring-down spectroscopy is a ubiquitous optical method used to study light-matter interactions with high resolution, sensitivity and accuracy. However, it has never been performed with the multiplexing advantages of direct frequency comb spectroscopy without sacrificing orders of magnitude of resolution. We present dual-comb cavity ring-down spectroscopy (DC-CRDS) based on the parallel heterodyne detection of ring-down signals with a local oscillator comb to yield absorption and dispersion spectra. These spectra are obtained from widths and positions of cavity modes. We present two approaches which leverage the dynamic cavity response to coherently or randomly driven changes in the amplitude or frequency of the probe field. Both techniques yield accurate spectra of methane - an important greenhouse gas and breath biomarker. The high sensitivity and accuracy of broadband DC-CRDS, shows promise for applications like studies of the structure and dynamics of large molecules, multispecies trace gas detection and isotopic composition.
△ Less
Submitted 14 June, 2021;
originally announced June 2021.
-
Frequency stabilization of a quantum cascade laser by weak resonant feedback from a Fabry-Pérot cavity
Authors:
Gang Zhao,
Jianfei Tian,
Joseph T. Hodges,
Adam J. Fleisher
Abstract:
Frequency-stabilized mid-infrared lasers are valuable tools for precision molecular spectroscopy. However, their implementation remains limited by complicated stabilization schemes. Here we achieve optical self-locking of a quantum cascade laser to the resonant leak-out field of a highly mode-matched two-mirror cavity. The result is a simple approach to achieving ultra-pure frequencies from high-p…
▽ More
Frequency-stabilized mid-infrared lasers are valuable tools for precision molecular spectroscopy. However, their implementation remains limited by complicated stabilization schemes. Here we achieve optical self-locking of a quantum cascade laser to the resonant leak-out field of a highly mode-matched two-mirror cavity. The result is a simple approach to achieving ultra-pure frequencies from high-powered mid-infrared lasers. For short time scales (<0.1 ms), we report a linewidth reduction factor of $3\times10^{-6}$ to a linewidth of 12 Hz. Furthermore, we demonstrate two-photon cavity-enhanced absorption spectroscopy of an N$_{2}$O overtone transition near a wavelength of 4.53 $μ$m.
△ Less
Submitted 15 April, 2021;
originally announced April 2021.
-
Mid-infrared monocrystalline interference coatings with excess optical loss below 10 ppm
Authors:
G. Winkler,
L. W. Perner,
G. -W. Truong,
G. Zhao,
D. Bachmann,
A. S. Mayer,
J. Fellinger,
D. Follman,
P. Heu,
C. Deutsch,
D. M. Bailey,
H. Peelaers,
S. Puchegger,
A. J. Fleisher,
G. D. Cole,
O. H. Heckl
Abstract:
We present high-reflectivity substrate-transferred single-crystal GaAs/AlGaAs interference coatings at a center wavelength of 4.54 um with record-low excess optical loss below 10 parts per million. These high-performance mirrors are realized via a novel microfabrication process that differs significantly from the production of amorphous multilayers generated via physical vapor deposition processes…
▽ More
We present high-reflectivity substrate-transferred single-crystal GaAs/AlGaAs interference coatings at a center wavelength of 4.54 um with record-low excess optical loss below 10 parts per million. These high-performance mirrors are realized via a novel microfabrication process that differs significantly from the production of amorphous multilayers generated via physical vapor deposition processes. This new process enables reduced scatter loss due to the low surface and interfacial roughness, while low background do** in epitaxial growth ensures strongly reduced absorption. We report on a suite of optical measurements, including cavity ring-down, transmittance spectroscopy, and direct absorption tests to reveal the optical losses for a set of prototype mirrors. In the course of these measurements, we observe a unique polarization-orientation-dependent loss mechanism which we attribute to elastic anisotropy of these strained epitaxial multilayers. A future increase in layer count and a corresponding reduction of transmittance will enable optical resonators with a finesse in excess of 100 000 in the mid-infrared spectral region, allowing for advances in high resolution spectroscopy, narrow-linewidth laser stabilization, and ultrasensitive measurements of various light-matter interactions.
△ Less
Submitted 10 September, 2020;
originally announced September 2020.
-
Precision Spectroscopy of Nitrous Oxide Isotopocules with a Cross-Dispersed Spectrometer and Mid-Infrared Frequency Comb
Authors:
D. Michelle Bailey,
Gang Zhao,
Adam J. Fleisher
Abstract:
As a potent greenhouse gas and ozone depleting agent, nitrous oxide (N$_2$O) plays a critical role in the global climate. Effective mitigation relies on understanding global sources and sinks which can be supported through isotopic analysis. We present a cross-dispersed spectrometer, coupled with a mid-infrared frequency comb, capable of simultaneously monitoring all singly substituted, stable iso…
▽ More
As a potent greenhouse gas and ozone depleting agent, nitrous oxide (N$_2$O) plays a critical role in the global climate. Effective mitigation relies on understanding global sources and sinks which can be supported through isotopic analysis. We present a cross-dispersed spectrometer, coupled with a mid-infrared frequency comb, capable of simultaneously monitoring all singly substituted, stable isotopic variants of N$_2$O. Rigorous evaluation of the instrument lineshape function and data treatment are discussed. Laboratory characterization of the spectrometer demonstrates sub-GHz spectral resolution and an average precision of $7.4\times10^{-6}$ for fractional isotopic abundance retrievals in 1 s.
△ Less
Submitted 30 April, 2020;
originally announced April 2020.
-
Doppler-Free Two-Photon Cavity Ring-Down Spectroscopy of a Nitrous Oxide (N$_2$O) Vibrational Overtone Transition
Authors:
Gang Zhao,
D. Michelle Bailey,
Adam J. Fleisher,
Joseph T. Hodges,
Kevin K. Lehmann
Abstract:
We report Doppler-free two-photon absorption of N$_2$O at $λ$ = 4.53 $μ$m, measured by cavity ring-down spectroscopy. High power was achieved by optical self-locking of a quantum cascade laser to a linear resonator of finesse $F$ = 22730, and accurate laser detuning over a 400 MHz range was measured relative to an optical frequency comb. At a sample pressure of p = 0.13 kPa, we report a large two-…
▽ More
We report Doppler-free two-photon absorption of N$_2$O at $λ$ = 4.53 $μ$m, measured by cavity ring-down spectroscopy. High power was achieved by optical self-locking of a quantum cascade laser to a linear resonator of finesse $F$ = 22730, and accurate laser detuning over a 400 MHz range was measured relative to an optical frequency comb. At a sample pressure of p = 0.13 kPa, we report a large two-photon cross-section of $σ_{13}^{(2)}$ = 8.0 $\times$ 10$^{-41}$ cm$^4$ s molecule$^{-1}$ for the $Q$(18) rovibrational transition at a resonant frequency of $ν_0$ = 66179400.8 MHz.
△ Less
Submitted 27 March, 2020;
originally announced March 2020.
-
arXiv:2002.09584
[pdf]
physics.atom-ph
astro-ph.EP
astro-ph.IM
physics.ao-ph
physics.chem-ph
physics.ins-det
Cavity ring-down spectroscopy of CO$_2$ near $λ$ = 2.06 $μ$m: Accurate transition intensities for the Orbiting Carbon Observatory-2 (OCO-2) "strong band"
Authors:
Hélène Fleurbaey,
Hongming Yi,
Erin M. Adkins,
Adam J. Fleisher,
Joseph T. Hodges
Abstract:
The $λ$ = 2.06 $μ$m absorption band of CO$_2$ is widely used for the remote sensing of atmospheric carbon dioxide, making it relevant to many important top-down measurements of carbon flux. The forward models used in the retrieval algorithms employed in these measurements require increasingly accurate line intensity and line shape data from which absorption cross-sections can be computed. To overc…
▽ More
The $λ$ = 2.06 $μ$m absorption band of CO$_2$ is widely used for the remote sensing of atmospheric carbon dioxide, making it relevant to many important top-down measurements of carbon flux. The forward models used in the retrieval algorithms employed in these measurements require increasingly accurate line intensity and line shape data from which absorption cross-sections can be computed. To overcome accuracy limitations of existing line lists, we used frequency-stabilized cavity ring-down spectroscopy to measure 39 transitions in the $^{12}$C$^{16}$O$_2$ absorption band. The line intensities were measured with an estimated relative combined standard uncertainty of $u_r$ = 0.08 %. We predict the $J$-dependence of the measured intensities using two theoretical modesl: a one-dimensional spectroscopic model with Herman-Wallis rotation-vibration corrections, and a line-by-line ab initio dipole moment surface model [Zak et al. JQSRT 2016;177:31-42]. For the second approach, we fit only a single factor to rescale the theoretical integrated band intensity to be consistent with the measured intensities. We find that the latter approach yields an equally adequate representation of the fitted $J$-dependent intensity data and provides the most physically general representation of the results. Our recommended value for the integrated band intensity equal to 7.183$\times$10$^{-21}$ cm molecule$^{-1}$ $\pm$ 6$\times$10$^{-24}$ cm molecule$^{-1}$ is based on the rescaled ab initio model and corresponds to a fitted scale factor of 1.0069 $\pm$ 0.0002. Comparisons of literature intensity values to our results reveal systematic deviations ranging from $-$1.16 % to +0.33 %.
△ Less
Submitted 19 May, 2020; v1 submitted 20 February, 2020;
originally announced February 2020.
-
Cavity buildup dispersion spectroscopy
Authors:
A. Cygan,
A. J. Fleisher,
R. Ciuryło,
K. A. Gillis,
J. T. Hodges,
D. Lisak
Abstract:
Measurements of ultrahigh-fidelity absorption spectra can help validate quantum theory, engineer ultracold chemistry, and remotely sense atmospheres. Recent achievements in cavity-enhanced spectroscopy using either frequency-based dispersion or time-based absorption approaches have set new records for accuracy with uncertainties at the sub-per-mil level. However, laser scanning5 or susceptibility…
▽ More
Measurements of ultrahigh-fidelity absorption spectra can help validate quantum theory, engineer ultracold chemistry, and remotely sense atmospheres. Recent achievements in cavity-enhanced spectroscopy using either frequency-based dispersion or time-based absorption approaches have set new records for accuracy with uncertainties at the sub-per-mil level. However, laser scanning5 or susceptibility to nonlinearities limits their ultimate performance. Here we present cavity buildup dispersion spectroscopy (CBDS) in which the dispersive frequency shift of a cavity resonance is encoded in the cavity's transient response to a phase-locked non-resonant laser excitation. Beating between optical frequencies during buildup exactly localizes detuning from mode center, and thus enables single-shot dispersion measurements. CBDS yields an accuracy limited by the chosen frequency standard, a speed limited by the cavity round-trip time, and is currently 50 times less susceptible to detection nonlinearity compared to intensity-based methods. The universality of CBDS shows promise for improving fundamental research into a variety of light-matter interactions.
△ Less
Submitted 23 January, 2020;
originally announced January 2020.
-
High-resolution cavity ring-down spectroscopy of the $ν_1 + ν_6$ combination band of methanol at 2.0 $μ$m
Authors:
Hongming Yi,
Adam J. Fleisher
Abstract:
Reported here are portions of the infrared absorption cross-section for methanol (CH$_3$OH) as measured by frequency-stabilized cavity ring-down spectroscopy (FS-CRDS) at wavelengths near $λ$ = 2.0 $μ$m. High-resolution spectra of two gravimetric mixtures of CH$_3$OH-in-air with nominal mole fractions of 202.2 $μ$mol/mol and 45.89 $μ$mol/mol, respectively, were recorded at pressures between 0.8 kP…
▽ More
Reported here are portions of the infrared absorption cross-section for methanol (CH$_3$OH) as measured by frequency-stabilized cavity ring-down spectroscopy (FS-CRDS) at wavelengths near $λ$ = 2.0 $μ$m. High-resolution spectra of two gravimetric mixtures of CH$_3$OH-in-air with nominal mole fractions of 202.2 $μ$mol/mol and 45.89 $μ$mol/mol, respectively, were recorded at pressures between 0.8 kPa and 102 kPa and at a temperature of 298 K. Covering the experimental wavenumber range of 4990 cm$^{-1}$ to 5010 cm$^{-1}$ in increments of 0.0067 cm$^{-1}$ and with an instrument linewidth of 30 kHz, we observed an evolution in the CH$_3$OH spectrum from resolved absorption lines at a low pressure (0.833 kPa) to a pseudo-continuum of absorption at a near-atmospheric pressure (101.575 kPa). An analysis of resolvable features at the lowest recorded pressure yielded a minimum intramolecular vibrational energy redistribution (IVR) lifetime for the OH-stretch ($ν_1$) plus OH-bend ($ν_6$) combination of $τ_{IVR} \geq$ 232 ps - long compared to other methanol overtones and combinations. Consequently, we show that high-resolution FS-CRDS of this relatively weak CH$_3$OH combination band provided an additional avenue by which to study the intramolecular dynamics of this simplest organic molecule with hindered internal rotation.
△ Less
Submitted 24 November, 2019;
originally announced November 2019.
-
Direct frequency comb saturation spectroscopy with an ultradense tooth spacing of 100 Hz
Authors:
David A. Long,
Adam J. Fleisher,
Joseph T. Hodges
Abstract:
Electro-optic frequency combs with tooth spacings as low as 100 Hz were employed to probe electromagnetically induced transparency (EIT) and hyperfine pum** in rubidium and potassium vapor cells. From the potassium EIT transition we were able to determine the ground state hyperfine splitting with a fit uncertainty of 8 Hz. Importantly, because of the mutual coherence between the control and prob…
▽ More
Electro-optic frequency combs with tooth spacings as low as 100 Hz were employed to probe electromagnetically induced transparency (EIT) and hyperfine pum** in rubidium and potassium vapor cells. From the potassium EIT transition we were able to determine the ground state hyperfine splitting with a fit uncertainty of 8 Hz. Importantly, because of the mutual coherence between the control and probe beams, which originate from a single laser, features with linewidths several orders-of-magnitude narrower than the laser linewidth could be observed in a multiplexed fashion. This approach removes the need for slow scanning of either a single laser or a traditional mode-locked-laser-based optical frequency comb.
△ Less
Submitted 21 December, 2018;
originally announced December 2018.
-
Quantitative modeling of complex molecular response in coherent cavity-enhanced dual-comb spectroscopy
Authors:
Adam J. Fleisher,
David A. Long,
Joseph T. Hodges
Abstract:
We present a complex-valued electric field model for experimentally observed cavity transmission in coherent cavity-enhanced (CE) multiplexed spectroscopy (i.e., dual-comb spectroscopy, DCS). The transmission model for CE-DCS differs from that previously derived for Fourier-transform CE direct frequency comb spectroscopy [Foltynowicz et al., Appl. Phys. B 110, 163-175 (2013)] by the treatment of t…
▽ More
We present a complex-valued electric field model for experimentally observed cavity transmission in coherent cavity-enhanced (CE) multiplexed spectroscopy (i.e., dual-comb spectroscopy, DCS). The transmission model for CE-DCS differs from that previously derived for Fourier-transform CE direct frequency comb spectroscopy [Foltynowicz et al., Appl. Phys. B 110, 163-175 (2013)] by the treatment of the local oscillator which, in the case of CE-DCS, does not interact with the enhancement cavity. Validation is performed by measurements of complex-valued near-infrared spectra of CO and CO$_2$ by an electro-optic frequency comb coherently coupled to an enhancement cavity of finesse $F=19600$. Following validation, we measure the $30012\leftarrow00001$ $^{12}$C$^{16}$O$_2$ vibrational band origin with a combined standard uncertainty of 770 kHz (fractional uncertainty of $4\times10^{-9}$).
△ Less
Submitted 8 May, 2018;
originally announced May 2018.
-
Multiplexed sub-Doppler spectroscopy with an optical frequency comb
Authors:
David A. Long,
Adam J. Fleisher,
David F. Plusquellic,
Joseph T. Hodges
Abstract:
An optical frequency comb generated with an electro-optic phase modulator and a chirped radiofrequency waveform is used to perform saturation and pump-probe spectroscopy on the $D_1$ and $D_2$ transitions of atomic potassium. With a comb tooth spacing of 200 kHz and an optical bandwidth of 2 GHz the hyperfine transitions can be simultaneously observed. Interferograms are recorded in as little as 5…
▽ More
An optical frequency comb generated with an electro-optic phase modulator and a chirped radiofrequency waveform is used to perform saturation and pump-probe spectroscopy on the $D_1$ and $D_2$ transitions of atomic potassium. With a comb tooth spacing of 200 kHz and an optical bandwidth of 2 GHz the hyperfine transitions can be simultaneously observed. Interferograms are recorded in as little as 5 $μ$s (a timescale corresponding to the inverse of the comb tooth spacing). Importantly, the sub-Doppler features can be measured as long as the laser carrier frequency lies within the Doppler profile, thus removing the need for slow scanning or a priori knowledge of the frequencies of the sub-Doppler features. Sub-Doppler optical frequency comb spectroscopy has the potential to dramatically reduce acquisition times and allow for rapid and accurate assignment of complex molecular and atomic spectra which are presently intractable.
△ Less
Submitted 20 September, 2016;
originally announced September 2016.
-
Coherent cavity-enhanced dual-comb spectroscopy
Authors:
Adam J. Fleisher,
David A. Long,
Zachary D. Reed,
Joseph T. Hodges,
David F. Plusquellic
Abstract:
Dual-comb spectroscopy allows for the rapid, multiplexed acquisition of high-resolution spectra without the need for moving parts or low-resolution dispersive optics. This method of broadband spectroscopy is most often accomplished via tight phase locking of two mode-locked lasers or via sophisticated signal processing algorithms, and therefore, long integration times of phase coherent signals are…
▽ More
Dual-comb spectroscopy allows for the rapid, multiplexed acquisition of high-resolution spectra without the need for moving parts or low-resolution dispersive optics. This method of broadband spectroscopy is most often accomplished via tight phase locking of two mode-locked lasers or via sophisticated signal processing algorithms, and therefore, long integration times of phase coherent signals are difficult to achieve. Here we demonstrate an alternative approach to dual-comb spectroscopy using two phase modulator combs originating from a single continuous-wave laser capable of > 2 hours of coherent real-time averaging. The dual combs were generated by driving the phase modulators with step-recovery diodes where each comb consisted of > 250 teeth with 203 MHz spacing and spanned > 50 GHz region in the near-infrared. The step-recovery diodes are passive devices that provide low-phase-noise harmonics for efficient coupling into an enhancement cavity at picowatt optical powers. With this approach, we demonstrate the sensitivity to simultaneously monitor ambient levels of CO2, CO, HDO, and H2O in a single spectral region at a maximum acquisition rate of 150 kHz. Robust, compact, low-cost and widely tunable dual-comb systems could enable a network of distributed multiplexed optical sensors.
△ Less
Submitted 30 May, 2016; v1 submitted 1 March, 2016;
originally announced March 2016.
-
Mid-infrared VIPA Spectrometer for Rapid and Broadband Trace Gas Detection
Authors:
Lora Nugent-Glandorf,
Tyler Neely,
Florian Adler,
Adam J. Fleisher,
Kevin C. Cossel,
Bryce Bjork,
Tim Dinneen,
Jun Ye,
Scott A. Diddams
Abstract:
We present and characterize a 2-D imaging spectrometer based on a virtually-imaged phased array (VIPA) disperser for rapid, high-resolution molecular detection using mid-infrared (MIR) frequency combs at 3.1 and 3.8 μm. We demonstrate detection of CH4 at 3.1 μm with >3750 resolution elements spanning >80 nm with ~600 MHz resolution in a <10 μs acquisition time. In addition to broadband detection,…
▽ More
We present and characterize a 2-D imaging spectrometer based on a virtually-imaged phased array (VIPA) disperser for rapid, high-resolution molecular detection using mid-infrared (MIR) frequency combs at 3.1 and 3.8 μm. We demonstrate detection of CH4 at 3.1 μm with >3750 resolution elements spanning >80 nm with ~600 MHz resolution in a <10 μs acquisition time. In addition to broadband detection, rapid, time-resolved single-image detection is demonstrated by capturing dynamic concentration changes of CH4 at a rate of ~375 frames per second. Changes in absorption above the noise floor of 5\times 10-4 are readily detected on the millisecond time scale, leading to important future applications such as real time monitoring of trace gas concentrations and detection of reactive intermediates.
△ Less
Submitted 6 June, 2012;
originally announced June 2012.
-
Cavity-enhanced optical frequency comb spectroscopy in the mid-infrared - application to trace detection of H2O2
Authors:
Aleksandra Foltynowicz,
Piotr Maslowski,
Adam J. Fleisher,
Bryce Bjork,
Jun Ye
Abstract:
We demonstrate the first cavity-enhanced optical frequency comb spectroscopy in the mid-infrared wavelength region and report the sensitive real-time trace detection of hydrogen peroxide in the presence of a large amount of water. The experimental apparatus is based on a mid-infrared optical parametric oscillator synchronously pumped by a high power Yb:fiber laser, a high finesse broadband cavity,…
▽ More
We demonstrate the first cavity-enhanced optical frequency comb spectroscopy in the mid-infrared wavelength region and report the sensitive real-time trace detection of hydrogen peroxide in the presence of a large amount of water. The experimental apparatus is based on a mid-infrared optical parametric oscillator synchronously pumped by a high power Yb:fiber laser, a high finesse broadband cavity, and a fast-scanning Fourier transform spectrometer with autobalancing detection. The comb spectrum with a bandwidth of 200 nm centered around 3.75 μm is simultaneously coupled to the cavity and both degrees of freedom of the comb, i.e., the repetition rate and carrier envelope offset frequency, are locked to the cavity to ensure stable transmission. The autobalancing detection scheme reduces the intensity noise by a factor of 300, and a sensitivity of 5.4 {\times} 10^-9 cm^-1 Hz^-1/2 with a resolution of 800 MHz is achieved (corresponding to 6.9 {\times} 10^-11 cm^-1 Hz^-1/2 per spectral element for 6000 resolved elements). This yields a noise equivalent detection limit for hydrogen peroxide of 8 parts-per-billion (ppb); in the presence of 2.8% of water the detection limit is 130 ppb. Spectra of acetylene, methane and nitrous oxide at atmospheric pressure are also presented, and a line shape model is developed to simulate the experimental data.
△ Less
Submitted 6 February, 2012;
originally announced February 2012.