-
Quantum Electrodynamics in Strong Electromagnetic Fields: Substate Resolved K$α$ Transition Energies in Helium-like Uranium
Authors:
Philip Pfäfflein,
Günter Weber,
Steffen Allgeier,
Zoran Andelkovic,
Sonja Bernitt,
Andrey I. Bondarev,
Alexander Borovik,
Louis Duval,
Andreas Fleischmann,
Oliver Forstner,
Marvin Friedrich,
Jan Glorius,
Alexandre Gumberidze,
Christoph Hahn,
Daniel Hengstler,
Marc Oliver Herdrich,
Frank Herfurth,
Pierre-Michel Hillenbrand,
Anton Kalinin,
Markus Kiffer,
Felix Martin Kröger,
Maximilian Kubullek,
Patricia Kuntz,
Michael Lestinsky,
Yuri A. Litvinov
, et al. (12 additional authors not shown)
Abstract:
Using novel metallic magnetic calorimeter detectors at the CRYRING@ESR, we recorded X-ray spectra of stored and electron cooled helium-like uranium (U$^{90+}$) with an unmatched spectral resolution of close to 90 eV. This allowed for an accurate determination of the energies of all four components of the K$α$ transitions in U$^{90+}$. We find good agreement with state-of-the-art bound-state QED ca…
▽ More
Using novel metallic magnetic calorimeter detectors at the CRYRING@ESR, we recorded X-ray spectra of stored and electron cooled helium-like uranium (U$^{90+}$) with an unmatched spectral resolution of close to 90 eV. This allowed for an accurate determination of the energies of all four components of the K$α$ transitions in U$^{90+}$. We find good agreement with state-of-the-art bound-state QED calculations for the strong-field regime. Our results do not support any systematic deviation between experiment and theory in helium-like systems, the presence of which was subject of intense debates in recent years.
△ Less
Submitted 10 July, 2024; v1 submitted 4 July, 2024;
originally announced July 2024.
-
Projected background and sensitivity of AMoRE-II
Authors:
A. Agrawal,
V. V. Alenkov,
P. Aryal,
J. Beyer,
B. Bhandari,
R. S. Boiko,
K. Boonin,
O. Buzanov,
C. R. Byeon,
N. Chanthima,
M. K. Cheoun,
J. S. Choe,
Seonho Choi,
S. Choudhury,
J. S. Chung,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Y. M. Gavrilyuk,
A. M. Gezhaev,
O. Gileva
, et al. (81 additional authors not shown)
Abstract:
AMoRE-II aims to search for neutrinoless double beta decay with an array of 423 Li$_2$$^{100}$MoO$_4$ crystals operating in the cryogenic system as the main phase of the Advanced Molybdenum-based Rare process Experiment (AMoRE). AMoRE has been planned to operate in three phases: AMoRE-pilot, AMoRE-I, and AMoRE-II. AMoRE-II is currently being installed at the Yemi Underground Laboratory, located ap…
▽ More
AMoRE-II aims to search for neutrinoless double beta decay with an array of 423 Li$_2$$^{100}$MoO$_4$ crystals operating in the cryogenic system as the main phase of the Advanced Molybdenum-based Rare process Experiment (AMoRE). AMoRE has been planned to operate in three phases: AMoRE-pilot, AMoRE-I, and AMoRE-II. AMoRE-II is currently being installed at the Yemi Underground Laboratory, located approximately 1000 meters deep in Jeongseon, Korea. The goal of AMoRE-II is to reach up to $T^{0νββ}_{1/2}$ $\sim$ 6 $\times$ 10$^{26}$ years, corresponding to an effective Majorana mass of 15 - 29 meV, covering all the inverted mass hierarchy regions. To achieve this, the background level of the experimental configurations and possible background sources of gamma and beta events should be well understood. We have intensively performed Monte Carlo simulations using the GEANT4 toolkit in all the experimental configurations with potential sources. We report the estimated background level that meets the 10$^{-4}$counts/(keV$\cdot$kg$\cdot$yr) requirement for AMoRE-II in the region of interest (ROI) and show the projected half-life sensitivity based on the simulation study.
△ Less
Submitted 13 June, 2024;
originally announced June 2024.
-
MMC Array to Study X-ray Transitions in Muonic Atoms
Authors:
Daniel Unger,
Andreas Abeln,
Thomas Elias Cocolios,
Ofir Eizenberg,
Christian Enss,
Andreas Fleischmann,
Loredana Gastaldo,
César Godinho,
Michael Heines,
Daniel Hengstler,
Paul Indelicato,
Ashish Jadhav,
Daniel Kreuzberger,
Klaus Kirch,
Andreas Knecht,
Jorge Machado,
Ben Ohayon,
Nancy Paul,
Randolf Pohl,
Katharina von Schoeler,
Stergiani Marina Vogiatzi,
Frederik Wauters
Abstract:
The QUARTET collaboration aims to significantly improve the precision of the absolute nuclear charge radii of light nuclei from Li to Ne by using an array of metallic magnetic calorimeters to perform high-precision X-ray spectroscopy of low-lying states in muonic atoms. A proof-of-principle measurement with lithium, beryllium and boron is planned for fall 2023 at the Paul Scherrer Institute. We di…
▽ More
The QUARTET collaboration aims to significantly improve the precision of the absolute nuclear charge radii of light nuclei from Li to Ne by using an array of metallic magnetic calorimeters to perform high-precision X-ray spectroscopy of low-lying states in muonic atoms. A proof-of-principle measurement with lithium, beryllium and boron is planned for fall 2023 at the Paul Scherrer Institute. We discuss the performance achieved with the maXs-30 detector module to be used. To place the detector close to the target chamber where the muon beam will impact the material under study, we have developed a new dilution refrigerator sidearm. We further discuss the expected efficiency given the transparency of the X-ray windows and the quantum efficiency of the detector. The expected muonic X-ray rate combined with the high resolving power and detection efficiency of the detector suggest that QUARTET will be able to study the de-excitation of light muonic atoms at an unprecedented level, increasing the relative energy resolution by up to a factor of 20 compared to conventional detector techniques.
△ Less
Submitted 6 April, 2024; v1 submitted 20 November, 2023;
originally announced November 2023.
-
Towards Precision Muonic X-Ray Measurements of Charge Radii of Light Nuclei
Authors:
Ben Ohayon,
Andreas Abeln,
Silvia Bara,
Thomas Elias Cocolios,
Ofir Eizenberg,
Andreas Fleischmann,
Loredana Gastaldo,
César Godinho,
Michael Heines,
Daniel Hengstler,
Guillaume Hupin,
Paul Indelicato,
Klaus Kirch,
Andreas Knecht,
Daniel Kreuzberger,
Jorge Machado,
Petr Navratil,
Nancy Paul,
Randolf Pohl,
Daniel Unger,
Stella Vogiatzi,
Katharina von Schoeler,
Frederik Wauters
Abstract:
We propose an experiment to measure the nuclear charge radii of light elements with up to 20~times higher accuracy. These are essential both for understanding nuclear physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyon…
▽ More
We propose an experiment to measure the nuclear charge radii of light elements with up to 20~times higher accuracy. These are essential both for understanding nuclear physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyond the Standard Model. The energy levels of muonic atoms are highly susceptible to nuclear structure, especially to the mean square charge radius. The radii of the lightest nuclei (with the atomic number, $Z=1,2$) have been determined with high accuracy using laser spectroscopy in muonic atoms, while those of medium mass and above were determined using X-ray spectroscopy with semiconductor detectors. In this communication, we present a new experiment, aiming to obtain precision measurements of the radii of light nuclei $3 \leq Z \leq 10$ using single-photon energy measurements with cryogenic microcalorimeters; a quantum-sensing technology capable of high efficiency with outstanding resolution for low-energy X-rays.
△ Less
Submitted 17 February, 2024; v1 submitted 5 October, 2023;
originally announced October 2023.
-
Development and characterisation of high-resolution microcalorimeter detectors for the ECHo-100k experiment
Authors:
Federica Mantegazzini,
Neven Kovac,
Christian Enss,
Andreas Fleischmann,
Markus Griedel,
Loredana Gastaldo
Abstract:
The goal of the ECHo experiment is a direct determination of the absolute scale of the neutrino mass by the analysis of the end-point region of the Ho-163 electron capture (EC) spectrum. The results of the first phase of the experiment, ECHo-1k, have paved the way for the current phase, ECHo-100k, which aims at a sensitivity below 2 eV on the effective electron neutrino mass. In order to reach thi…
▽ More
The goal of the ECHo experiment is a direct determination of the absolute scale of the neutrino mass by the analysis of the end-point region of the Ho-163 electron capture (EC) spectrum. The results of the first phase of the experiment, ECHo-1k, have paved the way for the current phase, ECHo-100k, which aims at a sensitivity below 2 eV on the effective electron neutrino mass. In order to reach this goal, a new generation of high-resolution magnetic microcalorimeters with embedded Ho-163 have been developed and characterised. The design has been optimised to meet all the challenging requirements of the ECHo-100k experimental phase, such as excellent energy resolution, wafer scale implantation and multi-chip operation with multiplexing read-out. We present the optimisation studies, the final design of the detector array and the first characterisation studies. The results demonstrate that the detectors fully match and even surpass the requirements for the current experimental phase, ECHo-100k.
△ Less
Submitted 24 July, 2023; v1 submitted 16 January, 2023;
originally announced January 2023.
-
Muonic-Atom Spectroscopy and Impact on Nuclear Structure and Precision QED Theory
Authors:
Aldo Antognini,
Sonia Bacca,
Andreas Fleischmann,
Loredana Gastaldo,
Franziska Hagelstein,
Paul Indelicato,
Andreas Knecht,
Vadim Lensky,
Ben Ohayon,
Vladimir Pascalutsa,
Nancy Paul,
Randolf Pohl,
Frederik Wauters
Abstract:
Recent progress in laser and x-ray spectroscopy of muonic atoms offers promising long-term possibilities at the intersection of atomic, nuclear and particle physics. In muonic hydrogen, laser spectroscopy measurements will determine the ground-state hyperfine splitting (HFS) and additionally improve the Lamb shift by a factor of 5. Precision spectroscopy with cryogenic microcalorimeters has the po…
▽ More
Recent progress in laser and x-ray spectroscopy of muonic atoms offers promising long-term possibilities at the intersection of atomic, nuclear and particle physics. In muonic hydrogen, laser spectroscopy measurements will determine the ground-state hyperfine splitting (HFS) and additionally improve the Lamb shift by a factor of 5. Precision spectroscopy with cryogenic microcalorimeters has the potential to significantly improve the charge radii of the light nuclei in the $Z=3-8$ range. Complementary progress in precision should be achieved on the theory of nucleon- and nuclear-structure effects. The impact of this muonic-atom spectroscopy program will be amplified by the upcoming results from H and He$^+$ spectroscopy, simple molecules such as HD$^+$ and Penning trap measurements. In this broader context, one can test ab-initio nuclear theories, bound-state QED for two- or three-body systems, and determine fundamental constants, such as the Rydberg ($R_\infty$) and the fine-structure ($α$) constants.
△ Less
Submitted 30 October, 2022;
originally announced October 2022.
-
Integration of maXs-type microcalorimeter detectors for high-resolution x-ray spectroscopy into the experimental environment at the CRYRING@ESR electron cooler
Authors:
Ph. Pfäfflein,
S. Bernitt,
Ch. Hahn,
M. O. Herdrich,
F. M. Kröger,
E. B. Menz,
T. Over,
B. Zhu,
Th. Stöhlker,
G. Weber,
S. Allgeier,
M. Friedrich,
D. Hengstler,
P. Kuntz,
A. Fleischmann,
Ch. Enss,
A. Kalinin,
M. Lestinsky,
B. Löher,
U. Spillmann
Abstract:
We report on the first integration of novel magnetic microcalorimeter detectors (MMCs), developed within SPARC (Stored Particles Atomic Physics Research Collaboration), into the experimental environment of storage rings at GSI, Darmstadt, namely at the electron cooler of CRYRING@ESR. Two of these detector systems were positioned at the 0$^\circ$ and 180$^\circ$ view ports of the cooler section to…
▽ More
We report on the first integration of novel magnetic microcalorimeter detectors (MMCs), developed within SPARC (Stored Particles Atomic Physics Research Collaboration), into the experimental environment of storage rings at GSI, Darmstadt, namely at the electron cooler of CRYRING@ESR. Two of these detector systems were positioned at the 0$^\circ$ and 180$^\circ$ view ports of the cooler section to obtain high-resolution x-ray spectra originating from a stored beam of hydrogen-like uranium interacting with the cooler electrons. While previous test measurements with microcalorimeters at the accelerator facility of GSI were conducted in the mode of well-established stand-alone operation, for the present experiment we implemented several notable modifications to exploit the full potential of this type of detector for precision x-ray spectroscopy of stored heavy ions. Among these are a new readout system compatible with the multi branch system data acquisition platform of GSI, the synchronization of a quasi-continuous energy calibration with the operation cycle of the accelerator facility, as well as the first exploitation of the maXs detectors' time resolution to apply coincidence conditions for the detection of photons and charge-changed ions.
△ Less
Submitted 1 February, 2022;
originally announced February 2022.
-
Metallic magnetic calorimeter arrays for the first phase of the ECHo experiment
Authors:
F. Mantegazzini,
A. Barth,
H. Dorrer,
Ch. E. Düllmann,
C. Enss,
A. Fleischmann,
R. Hammann,
S. Kempf,
T. Kieck,
N. Kovac,
C. Velte,
M. Wegner,
K. Wendt,
T. Wickenhäuser,
L. Gastaldo
Abstract:
The ECHo experiment has been designed for the determination of the effective electron neutrino mass by means of the analysis of the end-point region of the Ho-163 electron capture spectrum. Metallic magnetic calorimeters enclosing Ho-163 are used for the high energy resolution calorimetric measurement of the Ho-163 spectrum. For the first phase of the experiment, ECHo-1k, a 72-pixel MMC array has…
▽ More
The ECHo experiment has been designed for the determination of the effective electron neutrino mass by means of the analysis of the end-point region of the Ho-163 electron capture spectrum. Metallic magnetic calorimeters enclosing Ho-163 are used for the high energy resolution calorimetric measurement of the Ho-163 spectrum. For the first phase of the experiment, ECHo-1k, a 72-pixel MMC array has been developed. The single-pixel design has been optimised to reach 100% stop** power for the radiation emitted in the Ho-163 electron capture process (besides the electron neutrino) and an energy resolution < 10 eV FWHM. We describe the design of the ECHo-1k detector chip, the fabrication steps and the characterisation at room temperature, at 4 K and at the final operation temperatures. In particular, a detailed analysis of the results from these tests allowed to define a quality check protocol based on parameters measurable at room temperature. We discuss the performance achieved with the two ECHo-1k detector chips - the first one with Ho-163 implanted in gold and the second one with Ho-163 implanted in silver - which have been used for the high statistics measurement of the ECHo-1k experiment. An average activity per pixel of 0.81 Bq and 0.71 Bq and an average energy resolution of 6.07 eV FWHM and 5.55 eV FWHM have been achieved with these two detectors, fulfilling the requirements for the first phase of the ECHo experiment.
△ Less
Submitted 18 November, 2021;
originally announced November 2021.
-
Data reduction for a calorimetrically measured $^{163}\mathrm{Ho}$ spectrum of the ECHo-1k experiment
Authors:
Robert Hammann,
Arnulf Barth,
Andreas Fleischmann,
Dennis Schulz,
Loredana Gastaldo
Abstract:
The electron capture in $^{163}\mathrm{Ho}$ experiment (ECHo) is designed to directly measure the effective electron neutrino mass by analysing the endpoint region of the $^{163}\mathrm{Ho}$ electron capture spectrum. We present a data reduction scheme for the analysis of high statistics data acquired with the first phase of the ECHo experiment, ECHo-1k, to reliably infer the energy of…
▽ More
The electron capture in $^{163}\mathrm{Ho}$ experiment (ECHo) is designed to directly measure the effective electron neutrino mass by analysing the endpoint region of the $^{163}\mathrm{Ho}$ electron capture spectrum. We present a data reduction scheme for the analysis of high statistics data acquired with the first phase of the ECHo experiment, ECHo-1k, to reliably infer the energy of $^{163}\mathrm{Ho}$ events and discard triggered noise or pile-up events. On a first level, the raw data is filtered purely based on the trigger time information of the acquired signals. On a second level, the time profile of each triggered event is analysed to identify the signals corresponding to a single energy deposition in the detector. We demonstrate that events not belonging to this category are discarded with an efficiency above 99.8%, with a minimal loss of $^{163}\mathrm{Ho}$ events of about 0.7%. While the filter using the trigger time information is completely energy independent, a slight energy dependence of the filter based on the time profile is precisely characterised. This data reduction protocol will be important to minimise systematic errors in the analysis of the $^{163}\mathrm{Ho}$ spectrum for the determination of the effective electron neutrino mass.
△ Less
Submitted 27 July, 2021;
originally announced July 2021.
-
Alpha backgrounds in the AMoRE-Pilot experiment
Authors:
V. Alenkov,
H. W. Bae,
J. Beyer,
R. S. Boiko,
K. Boonin,
O. Buzanov,
N. Chanthima,
M. K. Cheoun,
S. H. Choi,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. Gangapshev,
L. Gastaldo,
Yu. M. Gavriljuk,
A. Gezhaev,
V. D. Grigoryeva,
V. Gurentsov,
D. H. Ha,
C. Ha,
E. J. Ha,
I. Hahn,
E. J. Jeon
, et al. (81 additional authors not shown)
Abstract:
The Advanced Mo-based Rare process Experiment (AMoRE)-Pilot experiment is an initial phase of the AMoRE search for neutrinoless double beta decay of $^{100}$Mo, with the purpose of investigating the level and sources of backgrounds. Searches for neutrinoless double beta decay generally require ultimately low backgrounds. Surface $α$ decays on the crystals themselves or nearby materials can deposit…
▽ More
The Advanced Mo-based Rare process Experiment (AMoRE)-Pilot experiment is an initial phase of the AMoRE search for neutrinoless double beta decay of $^{100}$Mo, with the purpose of investigating the level and sources of backgrounds. Searches for neutrinoless double beta decay generally require ultimately low backgrounds. Surface $α$ decays on the crystals themselves or nearby materials can deposit a continuum of energies that can be as high as the $Q$-value of the decay itself and may fall in the region of interest (ROI). To understand these background events, we studied backgrounds from radioactive contaminations internal to and on the surface of the crystals or nearby materials with Geant4-based Monte Carlo simulations. In this study, we report on the measured $α$ energy spectra fitted with the corresponding simulated spectra for six crystal detectors, where sources of background contributions could be identified through high energy $α$ peaks and continuum parts in the energy spectrum for both internal and surface contaminations. We determine the low-energy contributions from internal and surface $α$ contaminations by extrapolating from the $α$ background fitting model.
△ Less
Submitted 5 December, 2022; v1 submitted 16 July, 2021;
originally announced July 2021.
-
Multichannel read-out for arrays of metallic magnetic calorimeters
Authors:
F. Mantegazzini,
S. Allgeier,
A. Barth,
C. Enss,
A. Ferring-Siebert,
A. Fleischmann,
L. Gastaldo,
R. Hammann,
D. Hengstler,
S. Kempf,
D. Richter,
D. Schulz,
D. Unger,
C. Velte,
M. Wegner
Abstract:
Metallic magnetic micro-calorimeters (MMCs) operated at millikelvin temperature offer the possibility to achieve eV-scale energy resolution with high stop** power for X-rays and massive particles in an energy range up to several tens of keV. This motivates their use in a wide range of applications in fields as particle physics, atomic and molecular physics. Present detector systems consist of MM…
▽ More
Metallic magnetic micro-calorimeters (MMCs) operated at millikelvin temperature offer the possibility to achieve eV-scale energy resolution with high stop** power for X-rays and massive particles in an energy range up to several tens of keV. This motivates their use in a wide range of applications in fields as particle physics, atomic and molecular physics. Present detector systems consist of MMC arrays read out by 32 two-stage SQUID read-out channels. In contrast to the design of the detector array and consequently the design of the front-end SQUIDs, which need to be optimised for the physics case and the particles to be detected in a given experiment, the read-out chain can be standardised. We present our new standardised 32-channel parallel read-out for the operation of MMC arrays to be operated in a dilution refrigerator. The read-out system consists of a detector module, whose design depends on the particular application, an amplifier module, ribbon cables from room temperature to the millikelvin platform and a data acquisition system. In particular, we describe the realisation of the read-out system prepared for the ECHo-1k experiment for the operation of two 64-pixel arrays. The same read-out concept is also used for the maXs detector systems, developed for the study of the de-excitation of highly charged heavy ions by X-rays, as well as for the MOCCA system, developed for the energy and position sensitive detection of neutral molecular fragments for the study of fragmentation when molecular ions recombine with electrons. The choice of standard modular components for the operation of 32-channel MMC arrays offer the flexibility to upgrade detector modules without the need of any changes in the read-out system and the possibility to individually exchange parts in case of damages or failures.
△ Less
Submitted 13 October, 2021; v1 submitted 22 February, 2021;
originally announced February 2021.
-
Flux ramp modulation based MHz frequency-division dc-SQUID multiplexer
Authors:
Daniel Richter,
Ludwig Hoibl,
Thomas Wolber,
Nick Karcher,
Andreas Fleischmann,
Christian Enss,
Marc Weber,
Oliver Sander,
Sebastian Kempf
Abstract:
We present a MHz frequency-division dc-SQUID multiplexer that is based on flux ramp modulation and a series array of $N$ identical current-sensing dc-SQUIDs with tightly coupled input coil. By running a periodic, sawtooth-shaped current signal through an additional modulation coil being tightly, but non-uniformly coupled to the individual SQUIDs, the voltage drop across the array changes according…
▽ More
We present a MHz frequency-division dc-SQUID multiplexer that is based on flux ramp modulation and a series array of $N$ identical current-sensing dc-SQUIDs with tightly coupled input coil. By running a periodic, sawtooth-shaped current signal through an additional modulation coil being tightly, but non-uniformly coupled to the individual SQUIDs, the voltage drop across the array changes according to the superposition of the flux-to-voltage characteristics of the individual SQUIDs within each cycle of the modulation signal. In this mode of operation, an input signal injected in the input coil of one of the SQUIDs and being quasi-static within a time frame adds a constant flux offset and leads to a phase shift of the associated SQUID characteristics. The latter is inherently proportional to the input signal and can be inferred by channelizing and down-converting the sampled array output voltage. Using a prototype multiplexer as well as a self-developed high-speed readout electronics for real-time phase determination, we demonstrate the simultaneous readout of four signal sources with MHz bandwidth per channel.
△ Less
Submitted 4 March, 2021; v1 submitted 16 January, 2021;
originally announced January 2021.
-
High-resolution for IAXO: MMC-based X-ray Detectors
Authors:
D. Unger,
A. Abeln,
C. Enss,
A. Fleischmann,
D. Hengstler,
S. Kempf,
L. Gastaldo
Abstract:
Axion helioscopes like the planned International Axion Observatory (IAXO) search for evidence of axions and axion-like particles (ALPs) from the Sun. A strong magnetic field is used to convert ALPs into photons via the generic ALP-photon coupling. To observe the resulting photons, X-ray detectors with low background and high efficiency are necessary. In addition, good energy resolution and low ene…
▽ More
Axion helioscopes like the planned International Axion Observatory (IAXO) search for evidence of axions and axion-like particles (ALPs) from the Sun. A strong magnetic field is used to convert ALPs into photons via the generic ALP-photon coupling. To observe the resulting photons, X-ray detectors with low background and high efficiency are necessary. In addition, good energy resolution and low energy threshold would allow for investigating the ALP properties by studying the X-ray spectrum after its discovery. We propose to use low temperature metallic magnetic calorimeters (MMCs). Here we present the first detector system based on MMCs developed for IAXO and discuss the results of the characterization. The detector consists of a two-dimensional 64-pixel array covering an active area of 16 mm$^2$ with a fill factor of 93 %. We achieve an average energy resolution of 6.1 eV FWHM allowing for energy thresholds below 100 eV. This detector is the first step towards a larger 1 cm$^2$ array matching the IAXO X-ray optics. We determine the background rate for an unshielded detector system in the energy range between 1 keV and 10 keV to be $3.2(1) \times 10^{-4}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$ from events acquired over 30 days. In the future, active and passive shields will significantly reduce the background induced by cosmic muons and natural radioactivity. Our results demonstrate that MMCs are a promising technology for helioscopes to discover and study ALPs.
△ Less
Submitted 8 June, 2021; v1 submitted 29 October, 2020;
originally announced October 2020.
-
Measurement of the $^{229}$Th isomer energy with a magnetic micro-calorimeter
Authors:
Tomas Sikorsky,
Jeschua Geist,
Daniel Hengstler,
Sebastian Kempf,
Loredana Gastaldo,
Christian Enss,
Christoph Mokry,
Jörg Runke,
Christoph E. Düllmann,
Peter Wobrauschek,
Kjeld Beeks,
Veronika Rosecker,
Johannes H. Sterba,
Georgy Kazakov,
Thorsten Schumm,
Andreas Fleischmann
Abstract:
We present a measurement of the low-energy (0--60$\,$keV) $γ$ ray spectrum produced in the $α$-decay of $^{233}$U using a dedicated cryogenic magnetic micro-calorimeter. The energy resolution of $\sim$$10\,$eV, together with exceptional gain linearity, allow us to measure the energy of the low-lying isomeric state in $^{229}$Th using four complementary evaluation schemes. The most accurate scheme…
▽ More
We present a measurement of the low-energy (0--60$\,$keV) $γ$ ray spectrum produced in the $α$-decay of $^{233}$U using a dedicated cryogenic magnetic micro-calorimeter. The energy resolution of $\sim$$10\,$eV, together with exceptional gain linearity, allow us to measure the energy of the low-lying isomeric state in $^{229}$Th using four complementary evaluation schemes. The most accurate scheme determines the $^{229}$Th isomer energy to be $8.10(17)\,$eV, corresponding to 153.1(37)$\,$nm, superseding in precision previous values based on $γ$ spectroscopy, and agreeing with a recent measurement based on internal conversion electrons. We also measure branching ratios of the relevant excited states to be $b_{29}=9.3(6)\%$ and $b_{42}=0.3(3)\%$.
△ Less
Submitted 27 May, 2020;
originally announced May 2020.
-
Development of a novel calorimetry setup based on metallic paramagnetic temperature sensors
Authors:
Andreas Reifenberger,
Andreas Reiser,
Sebastian Kempf,
Andreas Fleischmann,
Christian Enss
Abstract:
We have developed a new micro-fabricated platform for the measurement of the specific heat of low heat capacity mg-sized metallic samples, such as superconductors, down to temperatures of as low as $10\,\mathrm{mK}$. It addresses challenging aspects of setups of this kind such as the thermal contact between sample and platform, the thermometer resolution, and an addenda heat capacity exceeding tha…
▽ More
We have developed a new micro-fabricated platform for the measurement of the specific heat of low heat capacity mg-sized metallic samples, such as superconductors, down to temperatures of as low as $10\,\mathrm{mK}$. It addresses challenging aspects of setups of this kind such as the thermal contact between sample and platform, the thermometer resolution, and an addenda heat capacity exceeding that of the samples of interest (typically $\mbox{nJ/K at }20\,\mbox{mK}$). The setup allows us to use the relaxation method, where the thermal relaxation following a well defined heat pulse is monitored to extract the specific heat. The sample platform ($5 \times 5\, \mathrm{mm^2}$) includes a micro-structured paramagnetic \underline{Ag}:Er temperature sensor, which is read out by a dc-SQUID via a superconducting flux transformer. In this way, a relative temperature precision of $30\,\mathrm{nK/\sqrt{Hz}}$ can be reached, while the addenda heat capacity falls well below $0.5\,\mathrm{nJ/K}$ for $T < 300\,\mathrm{mK}$. A gold-coated mounting area ($4.4 \times 3 \, \mathrm{mm^2}$) is included to improve the thermal contact between sample and platform.
△ Less
Submitted 2 March, 2020;
originally announced March 2020.
-
First Results from the AMoRE-Pilot neutrinoless double beta decay experiment
Authors:
V. Alenkov,
H. W. Bae,
J. Beyer,
R. S. Boiko,
K. Boonin,
O. Buzanov,
N. Chanthima,
M. K. Cheoun,
D. M. Chernyak,
J. S. Choe,
S. Choi,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Yu. M. Gavriljuk,
A. M. Gezhaev,
V. D. Grigoryeva,
V. I. Gurentsov,
O. Gylova,
C. Ha,
D. H. Ha
, et al. (84 additional authors not shown)
Abstract:
The Advanced Molybdenum-based Rare process Experiment (AMoRE) aims to search for neutrinoless double beta decay (0$νββ$) of $^{100}$Mo with $\sim$100 kg of $^{100}$Mo-enriched molybdenum embedded in cryogenic detectors with a dual heat and light readout. At the current, pilot stage of the AMoRE project we employ six calcium molybdate crystals with a total mass of 1.9 kg, produced from $^{48}$Ca-de…
▽ More
The Advanced Molybdenum-based Rare process Experiment (AMoRE) aims to search for neutrinoless double beta decay (0$νββ$) of $^{100}$Mo with $\sim$100 kg of $^{100}$Mo-enriched molybdenum embedded in cryogenic detectors with a dual heat and light readout. At the current, pilot stage of the AMoRE project we employ six calcium molybdate crystals with a total mass of 1.9 kg, produced from $^{48}$Ca-depleted calcium and $^{100}$Mo-enriched molybdenum ($^{48\textrm{depl}}$Ca$^{100}$MoO$_4$). The simultaneous detection of heat(phonon) and scintillation (photon) signals is realized with high resolution metallic magnetic calorimeter sensors that operate at milli-Kelvin temperatures. This stage of the project is carried out in the Yangyang underground laboratory at a depth of 700 m. We report first results from the AMoRE-Pilot $0νββ$ search with a 111 kg$\cdot$d live exposure of $^{48\textrm{depl}}$Ca$^{100}$MoO$_4$ crystals. No evidence for $0νββ$ decay of $^{100}$Mo is found, and a upper limit is set for the half-life of 0$νββ$ of $^{100}$Mo of $T^{0ν}_{1/2} > 9.5\times10^{22}$ y at 90% C.L.. This limit corresponds to an effective Majorana neutrino mass limit in the range $\langle m_{ββ}\rangle\le(1.2-2.1)$ eV.
△ Less
Submitted 7 May, 2019; v1 submitted 22 March, 2019;
originally announced March 2019.
-
Development of $^{100}$Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search
Authors:
E. Armengaud,
C. Augier,
A. S. Barabash,
J. W. Beeman,
T. B. Bekker,
F. Bellini,
A. Benoît,
L. Bergé,
T. Bergmann,
J. Billard,
R. S. Boiko,
A. Broniatowski,
V. Brudanin,
P. Camus,
S. Capelli,
L. Cardani,
N. Casali,
A. Cazes,
M. Chapellier,
F. Charlieux,
D. M. Chernyak,
M. de Combarieu,
N. Coron,
F. A. Danevich,
I. Dafinei
, et al. (77 additional authors not shown)
Abstract:
This paper reports on the development of a technology involving $^{100}$Mo-enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ($\sim$1~kg), high optical quality, radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been produced and used to develop high…
▽ More
This paper reports on the development of a technology involving $^{100}$Mo-enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ($\sim$1~kg), high optical quality, radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been produced and used to develop high performance single detector modules based on 0.2--0.4~kg scintillating bolometers. In particular, the energy resolution of the lithium molybdate detectors near the $Q$-value of the double-beta transition of $^{100}$Mo (3034~keV) is 4--6~keV FWHM. The rejection of the $α$-induced dominant background above 2.6~MeV is better than 8$σ$. Less than 10~$μ$Bq/kg activity of $^{232}$Th ($^{228}$Th) and $^{226}$Ra in the crystals is ensured by boule recrystallization. The potential of $^{100}$Mo-enriched scintillating bolometers to perform high sensitivity double-beta decay searches has been demonstrated with only 10~kg$\times$d exposure: the two neutrino double-beta decay half-life of $^{100}$Mo has been measured with the up-to-date highest accuracy as $T_{1/2}$ = [6.90 $\pm$ 0.15(stat.) $\pm$ 0.37(syst.)] $\times$ 10$^{18}$~yr. Both crystallization and detector technologies favor lithium molybdate, which has been selected for the ongoing construction of the CUPID-0/Mo demonstrator, containing several kg of $^{100}$Mo.
△ Less
Submitted 4 October, 2017; v1 submitted 6 April, 2017;
originally announced April 2017.
-
A CaMoO4 Crystal Low Temperature Detector for the AMoRE Neutrinoless Double Beta Decay Search
Authors:
G. B. Kim,
S. Choi,
F. A. Danevich,
A. Fleischmann,
C. S. Kang,
H. J. Kim,
S. R. Kim,
Y. D. Kim,
Y. H. Kim,
V. A. Kornoukhov,
H. J. Lee,
J. H. Lee,
M. K. Lee,
S. J. Lee,
J. H. So,
W. S. Yoon
Abstract:
We report the development of a CaMoO4 crystal low temperature detector for the AMoRE neutrinoless double beta decay (0ν\b{eta}\b{eta}) search experiment. The prototype detector cell was composed of a 216 g CaMoO4 crystal and a metallic magnetic calorimeter. An over-ground measurement demonstrated FWHM resolution of 6-11 keV for full absorption gamma peaks. Pulse shape discrimination was clearly de…
▽ More
We report the development of a CaMoO4 crystal low temperature detector for the AMoRE neutrinoless double beta decay (0ν\b{eta}\b{eta}) search experiment. The prototype detector cell was composed of a 216 g CaMoO4 crystal and a metallic magnetic calorimeter. An over-ground measurement demonstrated FWHM resolution of 6-11 keV for full absorption gamma peaks. Pulse shape discrimination was clearly demonstrated in the phonon signals, and 7.6 σ of discrimination power was found for the α and \b{eta}/γ separation. The phonon signals showed rise-times of about 1 ms. It is expected that the relatively fast rise-time will increase the rejection efficiency of two-neutrino double beta decay pile-up events which can be one of the major background sources in 0ν\b{eta}\b{eta} searches.
△ Less
Submitted 24 February, 2016;
originally announced February 2016.
-
LUMINEU: a search for neutrinoless double beta decay based on ZnMoO$_4$ scintillating bolometers
Authors:
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoit,
A. Benoit,
L. Berge,
R. S. Boiko,
T. Bergmann,
J. Blumer,
A. Broniatowski,
V. Brudanin,
P. Camus,
A. Cazes,
M. Chapellier,
F. Charlieux,
D. M. Chernyak,
N. Coron,
P. Coulter,
F. A. Danevich,
T. de Boissiere,
R. Decourt,
M. De Jesus,
L. Devoyon,
A. -A. Drillien,
L. Dumoulin
, et al. (69 additional authors not shown)
Abstract:
The LUMINEU is designed to investigate the possibility to search for neutrinoless double beta decay in $^{100}$Mo by means of a large array of scintillating bolometers based on ZnMoO$_4$ crystals enriched in $^{100}$Mo. High energy resolution and relatively fast detectors, which are able to measure both the light and the heat generated upon the interaction of a particle in a crystal, are very prom…
▽ More
The LUMINEU is designed to investigate the possibility to search for neutrinoless double beta decay in $^{100}$Mo by means of a large array of scintillating bolometers based on ZnMoO$_4$ crystals enriched in $^{100}$Mo. High energy resolution and relatively fast detectors, which are able to measure both the light and the heat generated upon the interaction of a particle in a crystal, are very promising for the recognition and rejection of background events. We present the LUMINEU concepts and the experimental results achieved aboveground and underground with large-mass natural and enriched crystals. The measured energy resolution, the $α/β$ discrimination power and the radioactive internal contamination are all within the specifications for the projected final LUMINEU sensitivity. Simulations and preliminary results confirm that the LUMINEU technology can reach zero background in the region of interest (around 3 MeV) with exposures of the order of hundreds kg$\times$years, setting the bases for a next generation $0\nu2β$ decay experiment capable to explore the inverted hierarchy region of the neutrino mass pattern.
△ Less
Submitted 19 January, 2016;
originally announced January 2016.
-
Proceedings of the third French-Ukrainian workshop on the instrumentation developments for HEP
Authors:
F. Alessio,
S. Ya. Barsuk,
L. Berge,
O. A. Bezshyyko,
R. S. Boiko,
I. Chaikovska,
M. Chapellier,
G. Charles,
A. Chaus,
R. Chehab,
D. M. Chernyak,
N. Coron,
F. A. Danevich,
N. Delerue,
L. Devoyon,
A. -A. Drillien,
L. Dumoulin,
C. Enss,
O. Fedorchuk,
A. Fleischmann,
L. Gastaldo,
A. Giuliani,
D. Gray,
M. Gros,
S. Herve
, et al. (48 additional authors not shown)
Abstract:
The reports collected in these proceedings have been presented in the third French-Ukrainian workshop on the instrumentation developments for high-energy physics held at LAL, Orsay on October 15-16. The workshop was conducted in the scope of the IDEATE International Associated Laboratory (LIA). Joint developments between French and Ukrainian laboratories and universities as well as new proposals h…
▽ More
The reports collected in these proceedings have been presented in the third French-Ukrainian workshop on the instrumentation developments for high-energy physics held at LAL, Orsay on October 15-16. The workshop was conducted in the scope of the IDEATE International Associated Laboratory (LIA). Joint developments between French and Ukrainian laboratories and universities as well as new proposals have been discussed. The main topics of the papers presented in the Proceedings are developments for accelerator and beam monitoring, detector developments, joint developments for large-scale high-energy and astroparticle physics projects, medical applications.
△ Less
Submitted 23 December, 2015;
originally announced December 2015.
-
Technical Design Report for the AMoRE $0νββ$ Decay Search Experiment
Authors:
V. Alenkov,
P. Aryal,
J. Beyer,
R. S. Boiko,
K. Boonin,
O. Buzanov,
N. Chanthima,
M. K. Cheoun D. M. Chernyak,
J. Choi,
S. Choi,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Yu. M. Gavriljuk,
A. M. Gezhaev,
V. I. Gurentsov,
D. H Ha,
I. S. Hahn,
J. H. Jang,
E. J. Jeon,
H. S. Jo
, et al. (65 additional authors not shown)
Abstract:
The AMoRE (Advanced Mo-based Rare process Experiment) project is a series of experiments that use advanced cryogenic techniques to search for the neutrinoless double-beta decay of \mohundred. The work is being carried out by an international collaboration of researchers from eight countries. These searches involve high precision measurements of radiation-induced temperature changes and scintillati…
▽ More
The AMoRE (Advanced Mo-based Rare process Experiment) project is a series of experiments that use advanced cryogenic techniques to search for the neutrinoless double-beta decay of \mohundred. The work is being carried out by an international collaboration of researchers from eight countries. These searches involve high precision measurements of radiation-induced temperature changes and scintillation light produced in ultra-pure \Mo[100]-enriched and \Ca[48]-depleted calcium molybdate ($\mathrm{^{48depl}Ca^{100}MoO_4}$) crystals that are located in a deep underground laboratory in Korea. The \mohundred nuclide was chosen for this \zeronubb decay search because of its high $Q$-value and favorable nuclear matrix element. Tests have demonstrated that \camo crystals produce the brightest scintillation light among all of the molybdate crystals, both at room and at cryogenic temperatures. $\mathrm{^{48depl}Ca^{100}MoO_4}$ crystals are being operated at milli-Kelvin temperatures and read out via specially developed metallic-magnetic-calorimeter (MMC) temperature sensors that have excellent energy resolution and relatively fast response times. The excellent energy resolution provides good discrimination of signal from backgrounds, and the fast response time is important for minimizing the irreducible background caused by random coincidence of two-neutrino double-beta decay events of \mohundred nuclei. Comparisons of the scintillating-light and phonon yields and pulse shape discrimination of the phonon signals will be used to provide redundant rejection of alpha-ray-induced backgrounds. An effective Majorana neutrino mass sensitivity that reaches the expected range of the inverted neutrino mass hierarchy, i.e., 20-50 meV, could be achieved with a 200~kg array of $\mathrm{^{48depl}Ca^{100}MoO_4}$ crystals operating for three years.
△ Less
Submitted 18 December, 2015;
originally announced December 2015.
-
Cryogenic micro-calorimeters for mass spectrometric identification of neutral molecules and molecular fragments
Authors:
O. Novotný,
S. Allgeier,
C. Enss,
A. Fleischmann,
L. Gamer,
D. Hengstler,
S. Kempf,
C. Krantz,
A. Pabinger,
C. Pies,
D. W. Savin,
D. Schwalm,
A. Wolf
Abstract:
We have systematically investigated the energy resolution of a magnetic micro-calorimeter (MMC) for atomic and molecular projectiles at impact energies ranging from $E\approx13$ to 150 keV. For atoms we obtained absolute energy resolutions down to $ΔE \approx 120$ eV and relative energy resolutions down to $ΔE/E\approx10^{-3}$. We also studied in detail the MMC energy-response function to molecula…
▽ More
We have systematically investigated the energy resolution of a magnetic micro-calorimeter (MMC) for atomic and molecular projectiles at impact energies ranging from $E\approx13$ to 150 keV. For atoms we obtained absolute energy resolutions down to $ΔE \approx 120$ eV and relative energy resolutions down to $ΔE/E\approx10^{-3}$. We also studied in detail the MMC energy-response function to molecular projectiles of up to mass 56 u. We have demonstrated the capability of identifying neutral fragmentation products of these molecules by calorimetric mass spectrometry. We have modeled the MMC energy-response function for molecular projectiles and conclude that backscattering is the dominant source of the energy spread at the impact energies investigated. We have successfully demonstrated the use of a detector absorber coating to suppress such spreads. We briefly outline the use of MMC detectors in experiments on gas-phase collision reactions with neutral products. Our findings are of general interest for mass spectrometric techniques, particularly for those desiring to make neutral-particle mass measurements.
△ Less
Submitted 12 June, 2015; v1 submitted 27 May, 2015;
originally announced May 2015.
-
Scintillating bolometers based on ZnMoO$_4$ and Zn$^{100}$MoO$_4$ crystals to search for 0$ν$2$β$ decay of $^{100}$Mo (LUMINEU project): first tests at the Modane Underground Laboratory
Authors:
D. V. Poda,
E. Armengaud,
Q. Arnaud,
C. Augier,
A. Benoît,
A. Benoît,
L. Bergé,
R. S. Boiko,
T. Bergmann,
J. Blümer,
A. Broniatowski,
V. Brudanin,
P. Camus,
A. Cazes,
B. Censier,
M. Chapellier,
F. Charlieux,
D. M. Chernyak,
N. Coron,
P. Coulter,
G. A. Cox,
F. A. Danevich,
T. de Boissière,
R. Decourt,
M. De Jesus
, et al. (69 additional authors not shown)
Abstract:
The technology of scintillating bolometers based on zinc molybdate (ZnMoO$_4$) crystals is under development within the LUMINEU project to search for 0$ν$2$β$ decay of $^{100}$Mo with the goal to set the basis for large scale experiments capable to explore the inverted hierarchy region of the neutrino mass pattern. Advanced ZnMoO$_4$ crystal scintillators with mass of $\sim$~0.3 kg were developed…
▽ More
The technology of scintillating bolometers based on zinc molybdate (ZnMoO$_4$) crystals is under development within the LUMINEU project to search for 0$ν$2$β$ decay of $^{100}$Mo with the goal to set the basis for large scale experiments capable to explore the inverted hierarchy region of the neutrino mass pattern. Advanced ZnMoO$_4$ crystal scintillators with mass of $\sim$~0.3 kg were developed and Zn$^{100}$MoO$_4$ crystal from enriched $^{100}$Mo was produced for the first time by using the low-thermal-gradient Czochralski technique. One ZnMoO$_4$ scintillator and two samples (59 g and 63 g) cut from the enriched boule were tested aboveground at milli-Kelvin temperature as scintillating bolometers showing a high detection performance. The first results of the low background measurements with three ZnMoO$_4$ and two enriched detectors installed in the EDELWEISS set-up at the Modane Underground Laboratory (France) are presented.
△ Less
Submitted 4 February, 2015;
originally announced February 2015.
-
First Calorimetric Measurement of OI-line in the Electron Capture Spectrum of $^{163}$Ho
Authors:
P. C. -O. Ranitzsch,
C. Hassel,
M. Wegner,
S. Kempf,
A. Fleischmann,
C. Enss,
L. Gastaldo,
A. Herlert,
K. Johnston
Abstract:
The isotope $^{163}$Ho undergoes an electron capture process with a recommended value for the energy available to the decay, $Q_{\rm EC}$, of about 2.5 keV. According to the present knowledge, this is the lowest $Q_{\rm EC}$ value for electron capture processes. Because of that, $^{163}$Ho is the best candidate to perform experiments to investigate the value of the electron neutrino mass based on…
▽ More
The isotope $^{163}$Ho undergoes an electron capture process with a recommended value for the energy available to the decay, $Q_{\rm EC}$, of about 2.5 keV. According to the present knowledge, this is the lowest $Q_{\rm EC}$ value for electron capture processes. Because of that, $^{163}$Ho is the best candidate to perform experiments to investigate the value of the electron neutrino mass based on the analysis of the calorimetrically measured spectrum.
We present for the first time the calorimetric measurement of the atomic de-excitation of the $^{163}$Dy daughter atom upon the capture of an electron from the 5s shell in $^{163}$Ho, OI-line. The measured peak energy is 48 eV. This measurement was performed using low temperature metallic magnetic calorimeters with the $^{163}$Ho ion implanted in the absorber.
We demonstrate that the calorimetric spectrum of $^{163}$Ho can be measured with high precision and that the parameters describing the spectrum can be learned from the analysis of the data. Finally, we discuss the implications of this result for the Electron Capture $^{163}$Ho experiment, ECHo, aiming to reach sub-eV sensitivity on the electron neutrino mass by a high precision and high statistics calorimetric measurement of the $^{163}$Ho spectrum.
△ Less
Submitted 29 August, 2014;
originally announced September 2014.
-
Purification of molybdenum oxide, growth and characterization of medium size zinc molybdate crystals for the LUMINEU program
Authors:
V. N. Shlegel,
L. Berge,
R. S. Boiko,
M. Chapellier,
D. M. Chernyak,
N. Coron,
F. A. Danevich,
R. Decourt,
V. Ya. Degoda,
L. Devoyon,
A. Drillien,
L. Dumoulin,
C. Enss,
A. Fleischmann,
L. Gastaldo,
A. Giuliani,
M. Gros,
S. Herve,
I. M. Ivanov,
V. V. Kobychev,
Ya. P. Kogut,
F. Koskas,
M. Loidl,
P. Magnier,
E. P. Makarov
, et al. (23 additional authors not shown)
Abstract:
The LUMINEU program aims at performing a pilot experiment on neutrinoless double beta decay of 100Mo using radiopure ZnMoO4 crystals operated as scintillating bolometers. Growth of high quality radiopure crystals is a complex task, since there are no commercially available molybdenum compounds with the required levels of purity and radioactive contamination. This paper discusses approaches to puri…
▽ More
The LUMINEU program aims at performing a pilot experiment on neutrinoless double beta decay of 100Mo using radiopure ZnMoO4 crystals operated as scintillating bolometers. Growth of high quality radiopure crystals is a complex task, since there are no commercially available molybdenum compounds with the required levels of purity and radioactive contamination. This paper discusses approaches to purify molybdenum and synthesize compound for high quality radiopure ZnMoO4 crystal growth. A combination of a double sublimation (with addition of zinc molybdate) with subsequent recrystallization in aqueous solutions (using zinc molybdate as a collector) was used. Zinc molybdate crystals up to 1.5 kg were grown by the low-thermal-gradient Czochralski technique, their optical, luminescent, diamagnetic, thermal and bolometric properties were tested.
△ Less
Submitted 12 December, 2013;
originally announced December 2013.
-
The Electron Capture $^{163}$Ho Experiment ECHo: an overview
Authors:
L. Gastaldo,
K. Blaum,
A. Doerr,
Ch. E. Duellmann,
K. Eberhardt,
S. Eliseev,
C. Enss,
Amand Faessler,
A. Fleischmann,
S. Kempf,
M. Krivoruchenko,
S. Lahiri,
M. Maiti,
Yu. N. Novikov,
P. C. -O. Ranitzsch,
F. Simkovic,
Z. Szusc,
M. Wegner
Abstract:
The determination of the absolute scale of the neutrino masses is one of the most challenging present questions in particle physics. The most stringent limit, $m(\barν_{\mathrm{e}})<2$eV, was achieved for the electron anti-neutrino mass \cite{numass}. Different approaches are followed to achieve a sensitivity on neutrino masses in the sub-eV range. Among them, experiments exploring the beta decay…
▽ More
The determination of the absolute scale of the neutrino masses is one of the most challenging present questions in particle physics. The most stringent limit, $m(\barν_{\mathrm{e}})<2$eV, was achieved for the electron anti-neutrino mass \cite{numass}. Different approaches are followed to achieve a sensitivity on neutrino masses in the sub-eV range. Among them, experiments exploring the beta decay or electron capture of suitable nuclides can provide information on the electron neutrino mass value. We present the Electron Capture $^{163}$Ho experiment ECHo, which aims to investigate the electron neutrino mass in the sub-eV range by means of the analysis of the calorimetrically measured energy spectrum following electron capture of $^{163}$Ho. A high precision and high statistics spectrum will be measured with arrays of metallic magnetic calorimeters. We discuss some of the essential aspects of ECHo to reach the proposed sensitivity: detector optimization and performance, multiplexed readout, $^{163}$Ho source production and purification, as well as a precise theoretical and experimental parameterization of the calorimetric EC spectrum including in particular the value of $Q_{\mathrm{EC}}$. We present preliminary results obtained with a first prototype of single channel detectors as well as a first 64-pixel chip with integrated micro-wave SQUID multiplexer, which will already allow to investigate $m(ν_{\mathrm{e}})$ in the eV range.
△ Less
Submitted 20 September, 2013;
originally announced September 2013.
-
Multiplexed readout of MMC detector arrays using non-hysteretic rf-SQUIDs
Authors:
S. Kempf,
M. Wegner,
L. Gastaldo,
A. Fleischmann,
C. Enss
Abstract:
Metallic magnetic calorimeters (MMCs) are widely used for various experiments in fields ranging from atomic and nuclear physics to x-ray spectroscopy, laboratory astrophysics or material science. Whereas in previous experiments single pixel detectors or small arrays have been used, for future applications large arrays are needed. Therefore, suitable multiplexing techniques for MMC arrays are curre…
▽ More
Metallic magnetic calorimeters (MMCs) are widely used for various experiments in fields ranging from atomic and nuclear physics to x-ray spectroscopy, laboratory astrophysics or material science. Whereas in previous experiments single pixel detectors or small arrays have been used, for future applications large arrays are needed. Therefore, suitable multiplexing techniques for MMC arrays are currently under development. A promising approach for the readout of large arrays is the microwave SQUID multiplexer that operates in the frequency domain and that employs non-hysteretic rf-SQUIDs to transduce the detector signals into a frequency shift of high $Q$ resonators which can be monitored by using standard microwave measurement techniques. In this paper we discuss the design and the expected performance of a recently developed and fabricated 64 pixel detector array with integrated microwave SQUID multiplexer. First experimental data were obtained characterizing dc-SQUIDs with virtually identical washer design.
△ Less
Submitted 19 September, 2013;
originally announced September 2013.
-
Prospects for measuring the 229Th isomer energy using a metallic magnetic microcalorimeter
Authors:
G. A. Kazakov,
V. Schauer,
J. Schwestka,
S. P. Stellmer,
J. H. Sterba,
A. Fleischmann,
L. Gastaldo,
A. Pabinger,
C. Enss,
T. Schumm
Abstract:
The Thorium-229 isotope features a nuclear isomer state with an extremely low energy. The currently most accepted energy value, 7.8 +- 0.5 eV, was obtained from an indirect measurement using a NASA x-ray microcalorimeter with an instrumental resolution 26 eV. We study, how state-of-the-art magnetic metallic microcalorimeters with an energy resolution down to a few eV can be used to measure the iso…
▽ More
The Thorium-229 isotope features a nuclear isomer state with an extremely low energy. The currently most accepted energy value, 7.8 +- 0.5 eV, was obtained from an indirect measurement using a NASA x-ray microcalorimeter with an instrumental resolution 26 eV. We study, how state-of-the-art magnetic metallic microcalorimeters with an energy resolution down to a few eV can be used to measure the isomer energy. In particular, resolving the 29.18 keV doublet in the γ-spectrum following the α-decay of Uranium-233, corresponding to the decay into the ground and isomer state, allows to measure the isomer transition energy without additional theoretical input parameters, and increase the energy accuracy. We study the possibility of resolving the 29.18 keV line as a doublet and the dependence of the attainable precision of the energy measurement on the signal and background count rates and the instrumental resolution.
△ Less
Submitted 2 April, 2014; v1 submitted 13 June, 2013;
originally announced June 2013.
-
The Electron Capture $^{163}$Ho Experiment ECHo
Authors:
K. Blaum,
A. Doerr,
C. E. Duellmann,
K. Eberhardt,
S. Eliseev,
C. Enss,
A. Faessler,
A. Fleischmann,
L. Gastaldo,
S. Kempf,
M. Krivoruchenko,
S. Lahiri,
M. Maiti,
Yu. N. Novikov,
P. C. -O. Ranitzsch,
F. Simkovic,
Z. Szusc,
M. Wegner
Abstract:
The determination of the absolute scale of the neutrino masses is one of the most challenging questions in particle physics. Different approaches are followed to achieve a sensitivity on neutrino masses in the sub-eV range. Among them, experiments exploring the beta decay and electron capture processes of suitable nuclides can provide necessary information on the electron neutrino mass value. In t…
▽ More
The determination of the absolute scale of the neutrino masses is one of the most challenging questions in particle physics. Different approaches are followed to achieve a sensitivity on neutrino masses in the sub-eV range. Among them, experiments exploring the beta decay and electron capture processes of suitable nuclides can provide necessary information on the electron neutrino mass value. In this talk we present the Electron Capture 163-Ho experiment ECHo, which aims to investigate the electron neutrino mass in the sub-eV range by means of the analysis of the calorimetrically measured energy spectrum following the electron capture process of 163-Ho. A high precision and high statistics spectrum will be measured by means of low temperature magnetic calorimeter arrays. We present preliminary results obtained with a first prototype of single channel detectors as well as the participating groups and their on-going developments.
△ Less
Submitted 11 June, 2013;
originally announced June 2013.
-
Characterization of low temperature metallic magnetic calorimeters having gold absorbers with implanted $^{163}$Ho ions
Authors:
L. Gastaldo,
P. Ranitzsch,
F. von Seggern,
J. -P. Porst,
S. Schäfer,
C. Pies,
S. Kempf,
T. Wolf,
A. Fleischmann,
C. Enss,
A. Herlert,
K. Johnston
Abstract:
For the first time we have investigated the behavior of fully micro-fabricated low temperature metallic magnetic calorimeters (MMCs) after undergoing an ion-implantation process. This experiment had the aim to show the possibility to perform a high precision calorimetric measurement of the energy spectrum following the electron capture of $^{163}$Ho using MMCs having the radioactive $^{163}$Ho ion…
▽ More
For the first time we have investigated the behavior of fully micro-fabricated low temperature metallic magnetic calorimeters (MMCs) after undergoing an ion-implantation process. This experiment had the aim to show the possibility to perform a high precision calorimetric measurement of the energy spectrum following the electron capture of $^{163}$Ho using MMCs having the radioactive $^{163}$Ho ions implanted in the absorber. The implantation of $^{163}$Ho ions was performed at ISOLDE-CERN. The performance of a detector that underwent an ion-implantation process is compared to the one of a detector without implanted ions. The results show that the implantation dose of ions used in this experiment does not compromise the properties of the detector. In addition an optimized detector design for future $^{163}$Ho experiments is presented.
△ Less
Submitted 25 June, 2012;
originally announced June 2012.