-
Input optics systems of the KAGRA detector during O3GK
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Bae,
Y. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
Z. Cao,
E. Capocasa,
M. Chan,
C. Chen,
K. Chen,
Y. Chen,
C-I. Chiang,
H. Chu,
Y-K. Chu,
S. Eguchi
, et al. (228 additional authors not shown)
Abstract:
KAGRA, the underground and cryogenic gravitational-wave detector, was operated for its solo observation from February 25th to March 10th, 2020, and its first joint observation with the GEO 600 detector from April 7th -- 21st, 2020 (O3GK). This study presents an overview of the input optics systems of the KAGRA detector, which consist of various optical systems, such as a laser source, its intensit…
▽ More
KAGRA, the underground and cryogenic gravitational-wave detector, was operated for its solo observation from February 25th to March 10th, 2020, and its first joint observation with the GEO 600 detector from April 7th -- 21st, 2020 (O3GK). This study presents an overview of the input optics systems of the KAGRA detector, which consist of various optical systems, such as a laser source, its intensity and frequency stabilization systems, modulators, a Faraday isolator, mode-matching telescopes, and a high-power beam dump. These optics were successfully delivered to the KAGRA interferometer and operated stably during the observations. The laser frequency noise was observed to limit the detector sensitivity above a few kHz, whereas the laser intensity did not significantly limit the detector sensitivity.
△ Less
Submitted 12 October, 2022;
originally announced October 2022.
-
Improving the stability of frequency dependent squeezing with bichromatic control of filter cavity length, alignment and incident beam pointing
Authors:
Yuhang Zhao,
Eleonora Capocasa,
Marc Eisenmann,
Naoki Aritomi,
Michael Page,
Yuefan Guo,
Eleonora Polini,
Koji Arai,
Yoichi Aso,
Martin van Beuzekom,
Yao-Chin Huang,
Ray-Kuang Lee,
Harald Lück,
Osamu Miyakawa,
Pierre Prat,
Ayaka Shoda,
Matteo Tacca,
Ryutaro Takahashi,
Henning Vahlbruch,
Marco Vardaro,
Chien-Ming Wu,
Matteo Leonardi,
Matteo Barsuglia,
Raffaele Flaminio
Abstract:
Frequency dependent squeezing is the main upgrade for achieving broadband quantum noise reduction in upcoming observation runs of gravitational wave detectors. The proper frequency dependence of the squeezed quadrature is obtained by reflecting squeezed vacuum from a Fabry-Perot filter cavity detuned by half of its linewidth. However, since the squeezed vacuum contains no classical amplitude, co-p…
▽ More
Frequency dependent squeezing is the main upgrade for achieving broadband quantum noise reduction in upcoming observation runs of gravitational wave detectors. The proper frequency dependence of the squeezed quadrature is obtained by reflecting squeezed vacuum from a Fabry-Perot filter cavity detuned by half of its linewidth. However, since the squeezed vacuum contains no classical amplitude, co-propagating auxiliary control beams are required to achieve the filter cavity's length, alignment, and incident beam pointing stability. In our frequency dependent squeezing experiment at the National Astronomical Observatory of Japan, we used a control beam at a harmonic of squeezed vacuum wavelength and found visible detuning variation related to the suspended mirrors angular drift. These variations can degrade interferometer quantum noise reduction. We investigated various mechanisms that can cause the filter cavity detuning variation. The detuning drift is found to be mitigated sufficiently by fixing the incident beam pointing and applying filter cavity automatic alignment. It was also found that there is an optimal position of the beam on the filter cavity mirror that helps to reduce the detuning fluctuations. Here we report a stabilized filter cavity detuning variation of less than 10$\,$Hz compared to the 113$\,$Hz cavity linewidth. Compared to previously published results [Phys. Rev. Lett. 124, 171101 (2020)], such detuning stability would be sufficient to make filter cavity detuning drift induced gravitational wave detector detection range fluctuation reduce from $11\%$ to within $2\%$.
△ Less
Submitted 21 March, 2022;
originally announced March 2022.
-
Prospects for improving the sensitivity of the cryogenic gravitational wave detector KAGRA
Authors:
Yuta Michimura,
Kentaro Komori,
Yutaro Enomoto,
Koji Nagano,
Atsushi Nishizawa,
Eiichi Hirose,
Matteo Leonardi,
Eleonora Capocasa,
Naoki Aritomi,
Yuhang Zhao,
Raffaele Flaminio,
Takafumi Ushiba,
Tomohiro Yamada,
Li-Wei Wei,
Hiroki Takeda,
Satoshi Tanioka,
Masaki Ando,
Kazuhiro Yamamoto,
Kazuhiro Hayama,
Sadakazu Haino,
Kentaro Somiya
Abstract:
Upgrades to improve the sensitivity of gravitational wave detectors enable more frequent detections and more precise source parameter estimation. Unlike other advanced interferometric detectors such as Advanced LIGO and Advanced Virgo, KAGRA requires different approach for the upgrade since it is the only detector which employs cryogenic cooling of the test masses. In this paper, we describe possi…
▽ More
Upgrades to improve the sensitivity of gravitational wave detectors enable more frequent detections and more precise source parameter estimation. Unlike other advanced interferometric detectors such as Advanced LIGO and Advanced Virgo, KAGRA requires different approach for the upgrade since it is the only detector which employs cryogenic cooling of the test masses. In this paper, we describe possible KAGRA upgrades with technologies focusing on different detector bands, and compare the impacts on the detection of compact binary coalescences. We show that either fivefold improvement in the $100 M_{\odot}$--$100 M_{\odot}$ binary black hole range, a factor of 1.3 improvement in the binary neutron star range, or a factor of 1.7 improvement in the sky localization of binary neutron stars is well feasible with upgrades that do not require changes in the existing cryogenic or vacuum infrastructure. We also show that twofold broadband sensitivity improvement is possible by applying multiple upgrades to the detector.
△ Less
Submitted 24 July, 2020; v1 submitted 16 June, 2020;
originally announced June 2020.
-
Overview of KAGRA: Detector design and construction history
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
Y. Aso,
S. -W. Bae,
Y. -B. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
E. Capocasa,
M. -L. Chan,
C. -S. Chen,
K. -H. Chen,
Y. -R. Chen,
H. -Y. Chu,
Y-K. Chu,
S. Eguchi,
Y. Enomoto,
R. Flaminio,
Y. Fujii
, et al. (175 additional authors not shown)
Abstract:
KAGRA is a newly built gravitational-wave telescope, a laser interferometer comprising arms with a length of 3\,km, located in Kamioka, Gifu, Japan. KAGRA was constructed under the ground and it is operated using cryogenic mirrors that help in reducing the seismic and thermal noise. Both technologies are expected to provide directions for the future of gravitational-wave telescopes. In 2019, KAGRA…
▽ More
KAGRA is a newly built gravitational-wave telescope, a laser interferometer comprising arms with a length of 3\,km, located in Kamioka, Gifu, Japan. KAGRA was constructed under the ground and it is operated using cryogenic mirrors that help in reducing the seismic and thermal noise. Both technologies are expected to provide directions for the future of gravitational-wave telescopes. In 2019, KAGRA finished all installations with the designed configuration, which we call the baseline KAGRA. In this occasion, we present an overview of the baseline KAGRA from various viewpoints in a series of of articles. In this article, we introduce the design configurations of KAGRA with its historical background.
△ Less
Submitted 2 July, 2020; v1 submitted 12 May, 2020;
originally announced May 2020.
-
Control of a filter cavity with coherent control sidebands
Authors:
Naoki Aritomi,
Matteo Leonardi,
Eleonora Capocasa,
Yuhang Zhao,
Raffaele Flaminio
Abstract:
For broadband quantum noise reduction of gravitational-wave detectors, frequency-dependent squeezed vacuum states realized using a filter cavity is a mature technique and will be implemented in Advanced LIGO and Advanced Virgo from the fourth observation run. To obtain the benefit of frequency-dependent squeezing, detuning and alignment of the filter cavity with respect to squeezed vacuum states m…
▽ More
For broadband quantum noise reduction of gravitational-wave detectors, frequency-dependent squeezed vacuum states realized using a filter cavity is a mature technique and will be implemented in Advanced LIGO and Advanced Virgo from the fourth observation run. To obtain the benefit of frequency-dependent squeezing, detuning and alignment of the filter cavity with respect to squeezed vacuum states must be controlled accurately. To this purpose, we suggest a new length and alignment control scheme, using coherent control sidebands which are already used to control the squeezing angle. Since both squeezed vacuum states and coherent control sidebands have the same mode matching conditions and almost the same frequency, detuning and alignment of the filter cavity can be controlled accurately with this scheme. In this paper, we show the principle of this scheme and its application to a gravitational-wave detector.
△ Less
Submitted 10 August, 2020; v1 submitted 3 April, 2020;
originally announced April 2020.
-
Frequency-Dependent Squeezed Vacuum Source for Broadband Quantum Noise Reduction in Advanced Gravitational-Wave Detectors
Authors:
Yuhang Zhao,
Naoki Aritomi,
Eleonora Capocasa,
Matteo Leonardi,
Marc Eisenmann,
Yuefan Guo,
Eleonora Polini,
Akihiro Tomura,
Koji Arai,
Yoichi Aso,
Yao-Chin Huang,
Ray-Kuang Lee,
Harald Lück,
Osamu Miyakawa,
Pierre Prat,
Ayaka Shoda,
Matteo Tacca,
Ryutaro Takahashi,
Henning Vahlbruch,
Marco Vardaro,
Chien-Ming Wu,
Matteo Barsuglia,
Raffaele Flaminio
Abstract:
The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current…
▽ More
The astrophysical reach of current and future ground-based gravitational-wave detectors is mostly limited by quantum noise, induced by vacuum fluctuations entering the detector output port. The replacement of this ordinary vacuum field with a squeezed vacuum field has proven to be an effective strategy to mitigate such quantum noise and it is currently used in advanced detectors. However, current squeezing cannot improve the noise across the whole spectrum because of the Heisenberg uncertainty principle: when shot noise at high frequencies is reduced, radiation pressure at low frequencies is increased. A broadband quantum noise reduction is possible by using a more complex squeezing source, obtained by reflecting the squeezed vacuum off a Fabry-Perot cavity, known as filter cavity. Here we report the first demonstration of a frequency-dependent squeezed vacuum source able to reduce quantum noise of advanced gravitational-wave detectors in their whole observation bandwidth. The experiment uses a suspended 300-m-long filter cavity, similar to the one planned for KAGRA, Advanced Virgo and Advanced LIGO, and capable of inducing a rotation of the squeezing ellipse below 100 Hz.
△ Less
Submitted 28 April, 2020; v1 submitted 24 March, 2020;
originally announced March 2020.
-
An arm length stabilization system for KAGRA and future gravitational-wave detectors
Authors:
T. Akutsu,
M. Ando,
K. Arai,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
Y. Aso,
S. Bae,
Y. Bae,
L. Baiotti,
R. Bajpai,
M. A. Barton,
K. Cannon,
E. Capocasa,
M. Chan,
C. Chen,
K. Chen,
Y. Chen,
H. Chu,
Y-K. Chu,
K. Doi,
S. Eguchi,
Y. Enomoto
, et al. (181 additional authors not shown)
Abstract:
Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock acquisition processes, the scheme called arm length stabilization (ALS) had been employed for lock acquisition of the arm cavities. We designed a new type of the ALS, wh…
▽ More
Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock acquisition processes, the scheme called arm length stabilization (ALS) had been employed for lock acquisition of the arm cavities. We designed a new type of the ALS, which is compatible with the interferometers having long arms like the next generation GW detectors. The features of the new ALS are that the control configuration is simpler than those of previous ones and that it is not necessary to lay optical fibers for the ALS along the kilometer-long arms of the detector. Along with simulations of its noise performance, an experimental test of the new ALS was performed utilizing a single arm cavity of KAGRA. This paper presents the first results of the test where we demonstrated that lock acquisition of the arm cavity was achieved using the new ALS and residual noise was measured to be $8.2\,\mathrm{Hz}$ in units of frequency, which is smaller than the linewidth of the arm cavity and thus low enough to lock the full interferometer of KAGRA in a repeatable and reliable manner.
△ Less
Submitted 28 November, 2019; v1 submitted 2 October, 2019;
originally announced October 2019.
-
Prospects for improving the sensitivity of KAGRA gravitational wave detector
Authors:
Yuta Michimura,
Masaki Ando,
Eleonora Capocasa,
Yutaro Enomoto,
Raffaele Flaminio,
Sadakazu Haino,
Kazuhiro Hayama,
Eiichi Hirose,
Yousuke Itoh,
Tomoya Kinugawa,
Kentro Komori,
Matteo Leonardi,
Norikatsu Mio,
Koji Nagano,
Hiroyuki Nakano,
Atsushi Nishizawa,
Norichika Sago,
Masaru Shibata,
Hisaaki Shinkai,
Kentaro Somiya,
Hiroki Takeda,
Takahiro Tanaka,
Satoshi Tanioka,
Li-Wei Wei,
Kazuhiro Yamamoto
Abstract:
KAGRA is a new gravitational wave detector which aims to begin joint observation with Advanced LIGO and Advanced Virgo from late 2019. Here, we present KAGRA's possible upgrade plans to improve the sensitivity in the decade ahead. Unlike other state-of-the-art detectors, KAGRA requires different investigations for the upgrade since it is the only detector which employs cryogenic cooling of the tes…
▽ More
KAGRA is a new gravitational wave detector which aims to begin joint observation with Advanced LIGO and Advanced Virgo from late 2019. Here, we present KAGRA's possible upgrade plans to improve the sensitivity in the decade ahead. Unlike other state-of-the-art detectors, KAGRA requires different investigations for the upgrade since it is the only detector which employs cryogenic cooling of the test mass mirrors. In this paper, investigations on the upgrade plans which can be realized by changing the input laser power, increasing the mirror mass, and injecting frequency dependent squeezed vacuum are presented. We show how each upgrade affects to the detector frequency bands and also discuss impacts on gravitational-wave science. We then propose an effective progression of upgrades based on technical feasibility and scientific scenarios.
△ Less
Submitted 6 June, 2019;
originally announced June 2019.
-
First cryogenic test operation of underground km-scale gravitational-wave observatory KAGRA
Authors:
KAGRA Collaboration,
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
W. Creus,
K. Doi,
K. Eda
, et al. (179 additional authors not shown)
Abstract:
KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic…
▽ More
KAGRA is a second-generation interferometric gravitational-wave detector with 3-km arms constructed at Kamioka, Gifu in Japan. It is now in its final installation phase, which we call bKAGRA (baseline KAGRA), with scientific observations expected to begin in late 2019. One of the advantages of KAGRA is its underground location of at least 200 m below the ground surface, which brings small seismic motion at low frequencies and high stability of the detector. Another advantage is that it cools down the sapphire test mass mirrors to cryogenic temperatures to reduce thermal noise. In April-May 2018, we have operated a 3-km Michelson interferometer with a cryogenic test mass for 10 days, which was the first time that km-scale interferometer was operated at cryogenic temperatures. In this article, we report the results of this "bKAGRA Phase 1" operation. We have demonstrated the feasibility of 3-km interferometer alignment and control with cryogenic mirrors.
△ Less
Submitted 11 January, 2019;
originally announced January 2019.
-
Vibration isolation system with a compact dam** system for power recycling mirrors of KAGRA
Authors:
Y. Akiyama,
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
V. Dattilo,
K. Doi,
Y. Enomoto,
R. Flaminio,
Y. Fujii
, et al. (149 additional authors not shown)
Abstract:
A vibration isolation system called Type-Bp system used for power recycling mirrors has been developed for KAGRA, the interferometric gravitational-wave observatory in Japan. A suspension of the Type-Bp system passively isolates an optic from seismic vibration using three main pendulum stages equipped with two vertical vibration isolation systems. A compact reaction mass around each of the main st…
▽ More
A vibration isolation system called Type-Bp system used for power recycling mirrors has been developed for KAGRA, the interferometric gravitational-wave observatory in Japan. A suspension of the Type-Bp system passively isolates an optic from seismic vibration using three main pendulum stages equipped with two vertical vibration isolation systems. A compact reaction mass around each of the main stages allows for achieving sufficient dam** performance with a simple feedback as well as vibration isolation ratio. Three Type-Bp systems were installed in KAGRA, and were proved to satisfy the requirements on the dam** performance, and also on estimated residual displacement of the optics.
△ Less
Submitted 10 January, 2019;
originally announced January 2019.
-
KAGRA: 2.5 Generation Interferometric Gravitational Wave Detector
Authors:
T. Akutsu,
M. Ando,
K. Arai,
Y. Arai,
S. Araki,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
S. Bae,
L. Baiotti,
M. A. Barton,
K. Cannon,
E. Capocasa,
C-S. Chen,
T-W. Chiu,
K. Cho,
Y-K. Chu,
K. Craig,
W. Creus,
K. Doi,
K. Eda,
Y. Enomoto
, et al. (169 additional authors not shown)
Abstract:
The recent detections of gravitational waves (GWs) reported by LIGO/Virgo collaborations have made significant impact on physics and astronomy. A global network of GW detectors will play a key role to solve the unknown nature of the sources in coordinated observations with astronomical telescopes and detectors. Here we introduce KAGRA (former name LCGT; Large-scale Cryogenic Gravitational wave Tel…
▽ More
The recent detections of gravitational waves (GWs) reported by LIGO/Virgo collaborations have made significant impact on physics and astronomy. A global network of GW detectors will play a key role to solve the unknown nature of the sources in coordinated observations with astronomical telescopes and detectors. Here we introduce KAGRA (former name LCGT; Large-scale Cryogenic Gravitational wave Telescope), a new GW detector with two 3-km baseline arms arranged in the shape of an "L", located inside the Mt. Ikenoyama, Kamioka, Gifu, Japan. KAGRA's design is similar to those of the second generations such as Advanced LIGO/Virgo, but it will be operating at the cryogenic temperature with sapphire mirrors. This low temperature feature is advantageous for improving the sensitivity around 100 Hz and is considered as an important feature for the third generation GW detector concept (e.g. Einstein Telescope of Europe or Cosmic Explorer of USA). Hence, KAGRA is often called as a 2.5 generation GW detector based on laser interferometry. The installation and commissioning of KAGRA is underway and its cryogenic systems have been successfully tested in May, 2018. KAGRA's first observation run is scheduled in late 2019, aiming to join the third observation run (O3) of the advanced LIGO/Virgo network. In this work, we describe a brief history of KAGRA and highlights of main feature. We also discuss the prospects of GW observation with KAGRA in the era of O3. When operating along with the existing GW detectors, KAGRA will be helpful to locate a GW source more accurately and to determine the source parameters with higher precision, providing information for follow-up observations of a GW trigger candidate.
△ Less
Submitted 20 November, 2018;
originally announced November 2018.
-
Measurement of optical losses in a high-finesse 300 m filter cavity for broadband quantum noise reduction in gravitational-wave detectors
Authors:
Eleonora Capocasa,
Yuefan Guo,
Marc Eisenmann,
Yuhang Zhao,
Akihiro Tomura,
Koji Arai,
Yoichi Aso,
Manuel Marchiò,
Laurent Pinard,
Pierre Prat,
Kentaro Somiya,
Roman Schnabel,
Matteo Tacca,
Ryutaro Takahashi,
Daisuke Tatsumi,
Matteo Leonardi,
Matteo Barsuglia,
Raffaele Flaminio
Abstract:
Earth-based gravitational-wave detectors will be limited by quantum noise in a large part of their spectrum. The most promising technique to achieve a broadband reduction of such noise is the injection of a frequency dependent squeezed vacuum state from the output port of the detector, whit the squeeze angle rotated by the reflection off a Fabry-Perot filter cavity. One of the most important param…
▽ More
Earth-based gravitational-wave detectors will be limited by quantum noise in a large part of their spectrum. The most promising technique to achieve a broadband reduction of such noise is the injection of a frequency dependent squeezed vacuum state from the output port of the detector, whit the squeeze angle rotated by the reflection off a Fabry-Perot filter cavity. One of the most important parameters limiting the squeezing performance is represented by the optical losses of the filter cavity. We report here the operation of a 300 m filter cavity prototype installed at the National Astronomical Observatory of Japan (NAOJ). The cavity is designed to obtain a rotation of the squeeze angle below 100 Hz. After achieving the resonance of the cavity with a multi-wavelength technique, the round trip losses have been measured to be between 50 ppm and 90 ppm. This result demonstrates that with realistic assumption on the input squeeze factor and on the other optical losses, a quantum noise reduction of at least 4 dB in the frequency region dominated by radiation pressure can be achieved.
△ Less
Submitted 27 June, 2018;
originally announced June 2018.
-
Construction of KAGRA: an Underground Gravitational Wave Observatory
Authors:
T. Akutsu,
M. Ando,
S. Araki,
A. Araya,
T. Arima,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
L. Baiotti,
M. A. Barton,
D. Chen,
K. Cho,
K. Craig,
R. DeSalvo,
K. Doi,
K. Eda,
Y. Enomoto,
R. Flaminio,
S. Fujibayashi,
Y. Fujii,
M. -K. Fujimoto,
M. Fukushima,
T. Furuhata
, et al. (202 additional authors not shown)
Abstract:
Major construction and initial-phase operation of a second-generation gravitational-wave detector KAGRA has been completed. The entire 3-km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferomet…
▽ More
Major construction and initial-phase operation of a second-generation gravitational-wave detector KAGRA has been completed. The entire 3-km detector is installed underground in a mine in order to be isolated from background seismic vibrations on the surface. This allows us to achieve a good sensitivity at low frequencies and high stability of the detector. Bare-bones equipment for the interferometer operation has been installed and the first test run was accomplished in March and April of 2016 with a rather simple configuration. The initial configuration of KAGRA is named {\it iKAGRA}. In this paper, we summarize the construction of KAGRA, including the study of the advantages and challenges of building an underground detector and the operation of the iKAGRA interferometer together with the geophysics interferometer that has been constructed in the same tunnel.
△ Less
Submitted 11 December, 2017; v1 submitted 30 November, 2017;
originally announced December 2017.
-
The status of KAGRA underground cryogenic gravitational wave telescope
Authors:
KAGRA Collaboration,
T. Akutsu,
M. Ando,
A. Araya,
N. Aritomi,
H. Asada,
Y. Aso,
S. Atsuta,
K. Awai,
M. A. Barton,
K. Cannon,
K. Craig,
W. Creus,
K. Doi,
K. Eda,
Y. Enomoto,
R. Flaminio,
Y. Fujii,
M. -K. Fujimoto,
T. Furuhata,
S. Haino,
K. Hasegawa,
K. Hashino,
K. Hayama,
S. Hirobayashi
, et al. (126 additional authors not shown)
Abstract:
KAGRA is a 3-km interferometric gravitational wave telescope located in the Kamioka mine in Japan. It is the first km-class gravitational wave telescope constructed underground to reduce seismic noise, and the first km-class telescope to use cryogenic cooling of test masses to reduce thermal noise. The construction of the infrastructure to house the interferometer in the tunnel, and the initial ph…
▽ More
KAGRA is a 3-km interferometric gravitational wave telescope located in the Kamioka mine in Japan. It is the first km-class gravitational wave telescope constructed underground to reduce seismic noise, and the first km-class telescope to use cryogenic cooling of test masses to reduce thermal noise. The construction of the infrastructure to house the interferometer in the tunnel, and the initial phase operation of the interferometer with a simple 3-km Michelson configuration have been completed. The first cryogenic operation is expected in 2018, and the observing runs with a full interferometer are expected in 2020s. The basic interferometer configuration and the current status of KAGRA are described.
△ Less
Submitted 13 October, 2017;
originally announced October 2017.
-
Mirror actuation design for the interferometer control of the KAGRA gravitational wave telescope
Authors:
Yuta Michimura,
Tomofumi Shimoda,
Takahiro Miyamoto,
Ayaka Shoda,
Koki Okutomi,
Yoshinori Fujii,
Hiroki Tanaka,
Mark A. Barton,
Ryutaro Takahashi,
Yoichi Aso,
Tomotada Akutsu,
Masaki Ando,
Yutaro Enomoto,
Raffaele Flaminio,
Kazuhiro Hayama,
Eiichi Hirose,
Yuki Inoue,
Takaaki Kajita,
Masahiro Kamiizumi,
Seiji Kawamura,
Keiko Kokeyama,
Kentaro Komori,
Rahul Kumar,
Osamu Miyakawa,
Koji Nagano
, et al. (14 additional authors not shown)
Abstract:
KAGRA is a 3-km cryogenic interferometric gravitational wave telescope located at an underground site in Japan. In order to achieve its target sensitivity, the relative positions of the mirrors of the interferometer must be finely adjusted with attached actuators. We have developed a model to simulate the length control loops of the KAGRA interferometer with realistic suspension responses and vari…
▽ More
KAGRA is a 3-km cryogenic interferometric gravitational wave telescope located at an underground site in Japan. In order to achieve its target sensitivity, the relative positions of the mirrors of the interferometer must be finely adjusted with attached actuators. We have developed a model to simulate the length control loops of the KAGRA interferometer with realistic suspension responses and various noises for mirror actuation. Using our model, we have designed the actuation parameters to have sufficient force range to acquire lock as well as to control all the length degrees of freedom without introducing excess noise.
△ Less
Submitted 21 June, 2019; v1 submitted 8 September, 2017;
originally announced September 2017.
-
Gravitational wave astronomy: the current status
Authors:
David Blair,
Li Ju,
Chunnong Zhao,
Linqing Wen,
Qi Chu,
Qi Fang,
RongGen Cai,
JiangRui Gao,
XueChun Lin,
Dong Liu,
Ling-An Wu,
ZongHong Zhu,
David H. Reitze,
Koji Arai,
Fan Zhang,
Raffaele Flaminio,
Xingjiang Zhu,
George Hobbs,
Richard N. Manchester,
Ryan M. Shannon,
Carlo Baccigalupi,
Peng Xu,
Xing Bian,
Zhoujian Cao,
Zi**g Chang
, et al. (14 additional authors not shown)
Abstract:
In the centenary year of Einstein's General Theory of Relativity, this paper reviews the current status of gravitational wave astronomy across a spectrum which stretches from attohertz to kilohertz frequencies. Sect. 1 of this paper reviews the historical development of gravitational wave astronomy from Einstein's first prediction to our current understanding the spectrum. It is shown that detecti…
▽ More
In the centenary year of Einstein's General Theory of Relativity, this paper reviews the current status of gravitational wave astronomy across a spectrum which stretches from attohertz to kilohertz frequencies. Sect. 1 of this paper reviews the historical development of gravitational wave astronomy from Einstein's first prediction to our current understanding the spectrum. It is shown that detection of signals in the audio frequency spectrum can be expected very soon, and that a north-south pair of next generation detectors would provide large scientific benefits. Sect. 2 reviews the theory of gravitational waves and the principles of detection using laser interferometry. The state of the art Advanced LIGO detectors are then described. These detectors have a high chance of detecting the first events in the near future. Sect. 3 reviews the KAGRA detector currently under development in Japan, which will be the first laser interferometer detector to use cryogenic test masses. Sect. 4 of this paper reviews gravitational wave detection in the nanohertz frequency band using the technique of pulsar timing. Sect. 5 reviews the status of gravitational wave detection in the attohertz frequency band, detectable in the polarisation of the cosmic microwave background, and discusses the prospects for detection of primordial waves from the big bang. The techniques described in sects. 1-5 have already placed significant limits on the strength of gravitational wave sources. Sects. 6 and 7 review ambitious plans for future space based gravitational wave detectors in the millihertz frequency band. Sect. 6 presents a roadmap for development of space based gravitational wave detectors by China while sect. 7 discusses a key enabling technology for space interferometry known as time delay interferometry.
△ Less
Submitted 9 February, 2016;
originally announced February 2016.
-
Mechanical loss in state-of-the-art amorphous optical coatings
Authors:
Massimo Granata,
Emeline Saracco,
Nazario Morgado,
Alix Cajgfinger,
Gianpietro Cagnoli,
Jérôme Degallaix,
Vincent Dolique,
Danièle Forest,
Janyce Franc,
Christophe Michel,
Laurent Pinard,
Raffaele Flaminio
Abstract:
We present the results of mechanical characterizations of many different high-quality optical coatings made of ion-beam-sputtered titania-doped tantala and silica, developed originally for interferometric gravitational-wave detectors. Our data show that in multi-layer stacks (like high-reflection Bragg mirrors, for example) the measured coating dissipation is systematically higher than the expecta…
▽ More
We present the results of mechanical characterizations of many different high-quality optical coatings made of ion-beam-sputtered titania-doped tantala and silica, developed originally for interferometric gravitational-wave detectors. Our data show that in multi-layer stacks (like high-reflection Bragg mirrors, for example) the measured coating dissipation is systematically higher than the expectation and is correlated with the stress condition in the sample. This has a particular relevance for the noise budget of current advanced gravitational-wave interferometers, and, more generally, for any experiment involving thermal-noise limited optical cavities.
△ Less
Submitted 21 January, 2016; v1 submitted 19 November, 2015;
originally announced November 2015.
-
Observation of the Three-Mode Parametric Instability
Authors:
X. Chen,
C. Zhao,
S. Danilishin,
L. Ju,
D. Blair,
H. Wang,
S. P. Vyatchanin,
C. Molinelli,
A. Kuhn,
S. Gras,
T. Briant,
P. -F. Cohadon,
A. Heidmann,
I. Roch-Jeune,
R. Flaminio,
C. Michel,
L. Pinard
Abstract:
Three-mode parametric interactions occur in triply-resonant optomechanical systems: photons from an optical pump mode are coherently scattered to a high-order mode by mechanical motion of the cavity mirrors, and these modes resonantly interact via radiation pressure force when certain conditions are met. Such effects are predicted to occur in long baseline advanced gravitational-wave detectors. Th…
▽ More
Three-mode parametric interactions occur in triply-resonant optomechanical systems: photons from an optical pump mode are coherently scattered to a high-order mode by mechanical motion of the cavity mirrors, and these modes resonantly interact via radiation pressure force when certain conditions are met. Such effects are predicted to occur in long baseline advanced gravitational-wave detectors. They can pump energy into acoustic modes, leading to parametric instability, but they can also extract acoustic energy, leading to optomechanical cooling. We develop a large amplitude model of three-mode interactions that explains the ring-up amplitude saturation after instability occurs. We also demonstrate both radiation-pressure cooling and mechanical amplification in two different three-mode optomechanical systems, including the first observation of the three-mode parametric instability in a free-space Fabry-Perot cavity. The experimental data agrees well with the theoretical model. Contrary to expectations, parametric instability does not lead to loss of cavity lock, a fact which may make it easier to implement control techniques to overcome instability.
△ Less
Submitted 11 November, 2014;
originally announced November 2014.
-
2D photonic-crystal optomechanical nanoresonator
Authors:
K. Makles,
T. Antoni,
A. G. Kuhn,
S. Deléglise,
T. Briant,
P. F. Cohadon,
R. Braive,
G. Beaudoin,
L. Pinard,
C. Michel,
V. Dolique,
R. Flaminio,
G. Cagnoli,
I. Robert-Philip,
A. Heidmann
Abstract:
We present the optical optimization of an optomechanical device based on a suspended InP membrane patterned with a 2D near-wavelength grating (NWG) based on a 2D photonic-crystal geometry. We first identify by numerical simulation a set of geometrical parameters providing a reflectivity higher than 99.8 % over a 50-nm span. We then study the limitations induced by the finite value of the optical w…
▽ More
We present the optical optimization of an optomechanical device based on a suspended InP membrane patterned with a 2D near-wavelength grating (NWG) based on a 2D photonic-crystal geometry. We first identify by numerical simulation a set of geometrical parameters providing a reflectivity higher than 99.8 % over a 50-nm span. We then study the limitations induced by the finite value of the optical waist and lateral size of the NWG pattern using different numerical approaches. The NWG grating, pierced in a suspended InP 265 nm-thick membrane, is used to form a compact microcavity involving the suspended nano-membrane as end mirror. The resulting cavity has a waist size smaller than 10 $μ$m and a finesse in the 200 range. It is used to probe the Brownian motion of the mechanical modes of the nanomembrane.
△ Less
Submitted 23 October, 2014;
originally announced October 2014.
-
Advanced Virgo: a 2nd generation interferometric gravitational wave detector
Authors:
F. Acernese,
M. Agathos,
K. Agatsuma,
D. Aisa,
N. Allemandou,
A. Allocca,
J. Amarni,
P. Astone,
G. Balestri,
G. Ballardin,
F. Barone,
J. -P. Baronick,
M. Barsuglia,
A. Basti,
F. Basti,
Th. S. Bauer,
V. Bavigadda,
M. Bejger,
M. G. Beker,
C. Belczynski,
D. Bersanetti,
A. Bertolini,
M. Bitossi,
M. A. Bizouard,
S. Bloemen
, et al. (209 additional authors not shown)
Abstract:
Advanced Virgo is the project to upgrade the Virgo interferometric detector of gravitational waves, with the aim of increasing the number of observable galaxies (and thus the detection rate) by three orders of magnitude. The project is now in an advanced construction phase and the assembly and integration will be completed by the end of 2015. Advanced Virgo will be part of a network with the two A…
▽ More
Advanced Virgo is the project to upgrade the Virgo interferometric detector of gravitational waves, with the aim of increasing the number of observable galaxies (and thus the detection rate) by three orders of magnitude. The project is now in an advanced construction phase and the assembly and integration will be completed by the end of 2015. Advanced Virgo will be part of a network with the two Advanced LIGO detectors in the US and GEO HF in Germany, with the goal of contributing to the early detections of gravitational waves and to opening a new observation window on the universe. In this paper we describe the main features of the Advanced Virgo detector and outline the status of the construction.
△ Less
Submitted 16 October, 2014; v1 submitted 18 August, 2014;
originally announced August 2014.
-
Reconstruction of the gravitational wave signal $h(t)$ during the Virgo science runs and independent validation with a photon calibrator
Authors:
Virgo collaboration,
T. Accadia,
F. Acernese,
M. Agathos,
A. Allocca,
P. Astone,
G. Ballardin,
F. Barone,
M. Barsuglia,
A. Basti,
Th. S. Bauer,
M. Bejger,
M . G. Beker,
C. Belczynski,
D. Bersanetti,
A. Bertolini,
M. Bitossi,
M. A. Bizouard,
M. Blom,
M. Boer,
F. Bondu,
L. Bonelli,
R. Bonnand,
V. Boschi,
L. Bosi
, et al. (171 additional authors not shown)
Abstract:
The Virgo detector is a kilometer-scale interferometer for gravitational wave detection located near Pisa (Italy). About 13 months of data were accumulated during four science runs (VSR1, VSR2, VSR3 and VSR4) between May 2007 and September 2011, with increasing sensitivity.
In this paper, the method used to reconstruct, in the range 10 Hz-10 kHz, the gravitational wave strain time series $h(t)$…
▽ More
The Virgo detector is a kilometer-scale interferometer for gravitational wave detection located near Pisa (Italy). About 13 months of data were accumulated during four science runs (VSR1, VSR2, VSR3 and VSR4) between May 2007 and September 2011, with increasing sensitivity.
In this paper, the method used to reconstruct, in the range 10 Hz-10 kHz, the gravitational wave strain time series $h(t)$ from the detector signals is described. The standard consistency checks of the reconstruction are discussed and used to estimate the systematic uncertainties of the $h(t)$ signal as a function of frequency. Finally, an independent setup, the photon calibrator, is described and used to validate the reconstructed $h(t)$ signal and the associated uncertainties.
The uncertainties of the $h(t)$ time series are estimated to be 8% in amplitude. The uncertainty of the phase of $h(t)$ is 50 mrad at 10 Hz with a frequency dependence following a delay of 8 $μ$s at high frequency. A bias lower than $4\,\mathrm{μs}$ and depending on the sky direction of the GW is also present.
△ Less
Submitted 3 July, 2014; v1 submitted 23 January, 2014;
originally announced January 2014.
-
Measurements of mechanical thermal noise and energy dissipation in optical dielectric coatings
Authors:
Tianjun Li,
Felipe A. Aguilar Sandoval,
Mickael Geitner,
Gianpietro Cagnoli,
Vincent Dolique,
Jérôme Degallaix,
Raffaele Flaminio,
Danièle Forest,
Massimo Granata,
Christophe Michel,
Nazario Morgado,
Laurent Pinard,
Ludovic Bellon
Abstract:
In recent years an increasing number of devices and experiments are shown to be limited by mechanical thermal noise. In particular sub-Hertz laser frequency stabilization and gravitational wave detectors, that are able to measure fluctuations of 1E-18 m/rtHz or less, are being limited by thermal noise in the dielectric coatings deposited on mirrors. In this paper we present a new measurement of th…
▽ More
In recent years an increasing number of devices and experiments are shown to be limited by mechanical thermal noise. In particular sub-Hertz laser frequency stabilization and gravitational wave detectors, that are able to measure fluctuations of 1E-18 m/rtHz or less, are being limited by thermal noise in the dielectric coatings deposited on mirrors. In this paper we present a new measurement of thermal noise in low absorption dielectric coatings deposited on micro-cantilevers and we compare it with the results obtained from the mechanical loss measurements. The coating thermal noise is measured on the widest range of frequencies with the highest signal to noise ratio ever achieved. In addition we present a novel technique to deduce the coating mechanical losses from the measurement of the mechanical quality factor which does not rely on the knowledge of the coating and substrate Young moduli. The dielectric coatings are deposited by ion beam sputtering. The results presented here give a frequency independent loss angle of (4.70 $\pm$ 0.2)x1E-4 with a Young's modulus of 118 GPa for annealed tantala from 10 Hz to 20 kHz. For as-deposited silica, a weak frequency dependence (~ f^{-0.025}) is observed in this frequency range, with a Young's modulus of 70 GPa and an internal dam** of (6.0 $\pm$ 0.3)x1E-4 at 16 kHz, but this value decreases by one order of magnitude after annealing and the frequency dependence disappears.
△ Less
Submitted 10 March, 2014; v1 submitted 31 December, 2013;
originally announced January 2014.
-
High quality factor mg-scale silicon mechanical resonators for 3-mode optoacoustic parametric amplifiers
Authors:
Francis Achilles Torres,
Phillip Meng,
Li Ju,
Chunnong Zhao,
David Gerald Blair,
Kai-Yu Liu,
Shiuh Chao,
Mariusz Martyniuk,
Isabelle Roch-Jeune,
Raffaele Flaminio,
Christophe Michel
Abstract:
Milligram-scale resonators have been shown to be suitable for the creation of 3-mode optoacoustic parametric amplifiers, based on a phenomena first predicted for advanced gravitational-wave detectors. To achieve practical optoacoustic parametric amplification, high quality factor resonators are required. We present millimetre-scale silicon resonators designed to exhibit a torsional vibration mode…
▽ More
Milligram-scale resonators have been shown to be suitable for the creation of 3-mode optoacoustic parametric amplifiers, based on a phenomena first predicted for advanced gravitational-wave detectors. To achieve practical optoacoustic parametric amplification, high quality factor resonators are required. We present millimetre-scale silicon resonators designed to exhibit a torsional vibration mode with a frequency in the 10^5 - 10^6 Hz range, for observation of 3-mode optoacoustic interactions in a compact table-top system. Our design incorporates an isolation stage and minimizes the acoustic loss from optical coating. We observe a quality factor of 7.5 x 10^5 for a mode frequency of 401.5 kHz, at room temperature and pressure of 10^-3 Pa. We confirmed the mode shape by map** the amplitude response across the resonator and comparing to finite element modelling. This study contributes towards the development of 3-mode optoacoustic parametric amplifiers for use in novel high-sensitivity signal transducers and quantum measurement experiments.
△ Less
Submitted 24 March, 2013;
originally announced March 2013.
-
Production of gamma rays by pulsed laser beam Compton scattering off GeV-electrons using a non-planar four-mirror optical cavity
Authors:
T. Akagi,
S. Araki,
J. Bonis,
I. Chaikovska,
R. Chiche,
R. Cizeron,
M. Cohen,
E. Cormier,
P. Cornebise,
N. Delerue,
R. Flaminio,
S. Funahashi,
D. Jehanno,
Y. Honda,
F. Labaye,
M. Lacroix,
R. Marie,
C. Michel,
S. Miyoshi,
S. Nagata,
T. Omori,
Y. Peinaud,
L. Pinard,
H. Shimizu,
V. Soskov
, et al. (6 additional authors not shown)
Abstract:
As part of the positron source R&D for future $e^+-e^-$ colliders and Compton based compact light sources, a high finesse non-planar four-mirror Fabry-Perot cavity has recently been installed at the ATF (KEK, Tsukuba, Japan). The first measurements of the gamma ray flux produced with a such cavity using a pulsed laser is presented here. We demonstrate the production of a flux of 2.7 $\pm$ 0.2 gamm…
▽ More
As part of the positron source R&D for future $e^+-e^-$ colliders and Compton based compact light sources, a high finesse non-planar four-mirror Fabry-Perot cavity has recently been installed at the ATF (KEK, Tsukuba, Japan). The first measurements of the gamma ray flux produced with a such cavity using a pulsed laser is presented here. We demonstrate the production of a flux of 2.7 $\pm$ 0.2 gamma rays per bunch crossing ($\sim3\times10^6$ gammas per second) during the commissioning.
△ Less
Submitted 4 January, 2012; v1 submitted 24 November, 2011;
originally announced November 2011.
-
Non-planar four-mirror optical cavity for high intensity gamma ray flux production by pulsed laser beam Compton scattering off GeV-electrons
Authors:
J. Bonis,
R. Chiche,
R. Cizeron,
M. Cohen,
E. Cormier,
P. Cornebise,
N. Delerue,
R. Flaminio,
D. Jehanno,
F. Labaye,
M. Lacroix,
R. Marie,
B. Mercier,
C. Michel,
Y. Peinaud,
L. Pinard,
C. Prevost,
V. Soskov,
A. Variola,
F. Zomer
Abstract:
As part of the R&D toward the production of high flux of polarised Gamma-rays we have designed and built a non-planar four-mirror optical cavity with a high finesse and operated it at a particle accelerator. We report on the main challenges of such cavity, such as the design of a suitable laser based on fiber technology, the mechanical difficulties of having a high tunability and a high mechanical…
▽ More
As part of the R&D toward the production of high flux of polarised Gamma-rays we have designed and built a non-planar four-mirror optical cavity with a high finesse and operated it at a particle accelerator. We report on the main challenges of such cavity, such as the design of a suitable laser based on fiber technology, the mechanical difficulties of having a high tunability and a high mechanical stability in an accelerator environment and the active stabilization of such cavity by implementing a double feedback loop in a FPGA.
△ Less
Submitted 21 December, 2011; v1 submitted 24 November, 2011;
originally announced November 2011.
-
High flux polarized gamma rays production: first measurements with a four-mirror cavity at the ATF
Authors:
Nicolas Delerue,
J. Bonis,
Iryna Chaikovska,
R. Chiche,
R. Cizeron,
M. Cohen,
J. Colin,
P. Cornebise,
D. Jehanno,
F. Labaye,
M. Lacroix,
R. Marie,
Y. Peinaud,
V. Soskov,
A. Variola,
F. Zomer,
E. Cormier,
R. Flaminio,
L. Pinard,
S. Araki,
S. Funahashi,
Y. Honda,
T. Omori,
H. Shimizu,
T. Terunuma
, et al. (5 additional authors not shown)
Abstract:
The next generation of e+/e- colliders will require a very intense flux of gamma rays to allow high current polarized positrons to be produced. This can be achieved by converting polarized high energy photons in polarized pairs into a target. In that context, an optical system consisting of a laser and a four-mirror passive Fabry-Perot cavity has recently been installed at the Accelerator Test Fac…
▽ More
The next generation of e+/e- colliders will require a very intense flux of gamma rays to allow high current polarized positrons to be produced. This can be achieved by converting polarized high energy photons in polarized pairs into a target. In that context, an optical system consisting of a laser and a four-mirror passive Fabry-Perot cavity has recently been installed at the Accelerator Test Facility (ATF) at KEK to produce a high flux of polarized gamma rays by inverse Compton scattering. In this contribution, we describe the experimental system and present preliminary results. An ultra-stable four-mirror non planar geometry has been implemented to ensure the polarization of the gamma rays produced. A fiber amplifier is used to inject about 10W in the high finesse cavity with a gain of 1000. A digital feedback system is used to keep the cavity at the length required for the optimal power enhancement. Preliminary measurements show that a flux of about $4\times10^6 γ$/s with an average energy of about 24 MeV was generated. Several upgrades currently in progress are also described.
△ Less
Submitted 14 October, 2011;
originally announced October 2011.
-
A micropillar for cavity optomechanics
Authors:
A. G. Kuhn,
M. Bahriz,
O. Ducloux,
C. Chartier,
O. Le Traon,
T. Briant,
P. -F. Cohadon,
A. Heidmann,
C. Michel,
L. Pinard,
R. Flaminio
Abstract:
We present a new micromechanical resonator designed for cavity optomechanics. We have used a micropillar geometry to obtain a high-frequency mechanical resonance with a low effective mass and a very high quality factor. We have coated a 60-$μ$m diameter low-loss dielectric mirror on top of the pillar and are planning to use this micromirror as part of a high-finesse Fabry-Perot cavity, to laser co…
▽ More
We present a new micromechanical resonator designed for cavity optomechanics. We have used a micropillar geometry to obtain a high-frequency mechanical resonance with a low effective mass and a very high quality factor. We have coated a 60-$μ$m diameter low-loss dielectric mirror on top of the pillar and are planning to use this micromirror as part of a high-finesse Fabry-Perot cavity, to laser cool the resonator down to its quantum ground state and to monitor its quantum position fluctuations by quantum-limited optical interferometry.
△ Less
Submitted 19 July, 2011;
originally announced July 2011.
-
Calibration and sensitivity of the Virgo detector during its second science run
Authors:
The Virgo Collaboration,
T. Accadia,
F. Acernese,
F. Antonucci,
P. Astone,
G. Ballardin,
F. Barone,
M. Barsuglia,
A. Basti,
Th. S. Bauer,
M. G. Beker,
A. Belletoile,
S. Birindelli,
M. Bitossi,
M. A. Bizouard,
M. Blom,
F. Bondu,
L. Bonelli,
R. Bonnand,
V. Boschi,
L. Bosi,
B. Bouhou,
S. Braccini,
C. Bradaschia,
A. Brillet
, et al. (153 additional authors not shown)
Abstract:
The Virgo detector is a kilometer-length interferometer for gravitational wave detection located near Pisa (Italy). During its second science run (VSR2) in 2009, six months of data were accumulated with a sensitivity close to its design. In this paper, the methods used to determine the parameters for sensitivity estimation and gravitational wave reconstruction are described. The main quantities to…
▽ More
The Virgo detector is a kilometer-length interferometer for gravitational wave detection located near Pisa (Italy). During its second science run (VSR2) in 2009, six months of data were accumulated with a sensitivity close to its design. In this paper, the methods used to determine the parameters for sensitivity estimation and gravitational wave reconstruction are described. The main quantities to be calibrated are the frequency response of the mirror actuation and the sensing of the output power. Focus is also put on their absolute timing. The monitoring of the calibration data as well as the parameter estimation with independent techniques are discussed to provide an estimation of the calibration uncertainties. Finally, the estimation of the Virgo sensitivity in the frequency-domain is described and typical sensitivities measured during VSR2 are shown.
△ Less
Submitted 18 January, 2011; v1 submitted 27 September, 2010;
originally announced September 2010.
-
A method to measure the resonance transitions between the gravitationally bound quantum states of neutrons in the GRANIT spectrometer
Authors:
M. Kreuz,
V. V. Nesvizhevsky,
P. Schmidt-Wellenburg,
T. Soldner,
M. Thomas,
H. G. Boerner,
F. Naraghi,
G. Pignol,
K. V. Protasov,
D. Rebreyend,
F. Vezzu,
R. Flaminio,
C. Michel,
L. Pinard,
A. Remillieux,
S. Baessler,
A. M. Gagarski,
L. A. Grigorieva,
T. M. Kuzmina,
A. E. Meyerovich,
L. P. Mezhov-Deglin,
G. A. Petrov,
A. V. Strelkov,
A. Yu. Voronin
Abstract:
We present a method to measure the resonance transitions between the gravitationally bound quantum states of neutrons in the GRANIT spectrometer. The purpose of GRANIT is to improve the accuracy of measurement of the quantum states parameters by several orders of magnitude, taking advantage of long storage of Ultracold neutrons at specula trajectories. The transitions could be excited using a pe…
▽ More
We present a method to measure the resonance transitions between the gravitationally bound quantum states of neutrons in the GRANIT spectrometer. The purpose of GRANIT is to improve the accuracy of measurement of the quantum states parameters by several orders of magnitude, taking advantage of long storage of Ultracold neutrons at specula trajectories. The transitions could be excited using a periodic spatial variation of a magnetic field gradient. If the frequency of such a perturbation (in the frame of a moving neutron) coincides with a resonance frequency defined by the energy difference of two quantum states, the transition probability will sharply increase. The GRANIT experiment is motivated by searches for short-range interactions (in particular spin-dependent interactions), by studying the interaction of a quantum system with a gravitational field, by searches for extensions of the Standard model, by the unique possibility to check the equivalence principle for an object in a quantum state and by studying various quantum optics phenomena.
△ Less
Submitted 3 February, 2009; v1 submitted 1 February, 2009;
originally announced February 2009.