Skip to main content

Showing 1–7 of 7 results for author: Fischer, M C

Searching in archive physics. Search in all archives.
.
  1. arXiv:2405.02294  [pdf

    physics.ins-det

    Servo-based light shutters with Arduino control

    Authors: Mathias S. Fischer, Martin C. Fischer

    Abstract: In optical experiments, shutters are devices that open or close a path of light. They are often used to limit the duration of light exposure onto a target or onto a detector in order to reduce possible light-induced damage. Many commercial shutters are available for different applications - some provide very fast opening and closing times, some can handle large optical powers, and others allow for… ▽ More

    Submitted 4 March, 2024; originally announced May 2024.

  2. arXiv:2403.08897  [pdf

    cond-mat.mtrl-sci physics.chem-ph physics.optics

    Noninvasive identification of carbon-based black pigments with pump-probe microscopy

    Authors: Heidi V. Kastenholz, Michael I. Topper, Warren S. Warren, Martin C. Fischer, David Grass

    Abstract: Carbon-based black pigments, a widely used class of pigments, are difficult to differentiate with the noninvasive techniques currently used in cultural heritage science. We utilize pump-probe microscopy to distinguish four common carbon-based black pigments as pure pigments, as two-component black pigment mixtures, and as a mixture of a black and a colorful pigment. This work also demonstrates tha… ▽ More

    Submitted 13 March, 2024; originally announced March 2024.

  3. arXiv:2310.15126  [pdf

    cond-mat.mtrl-sci physics.chem-ph physics.optics

    Non-destructive Three-dimensional Imaging of Artificially Degraded CdS Paints by Pump-probe Microscopy

    Authors: Yue Zhou, David Grass, Warren S. Warren, Martin C. Fischer

    Abstract: Cadmium sulfide (CdS) pigments have degraded in several well-known paintings, but the mechanisms of degradation have yet to be fully understood. Traditional non-destructive analysis techniques primarily focus on macroscopic degradation, whereas microscopic information is typically obtained with invasive techniques that require sample removal. Here, we demonstrate the use of pump-probe microscopy t… ▽ More

    Submitted 20 October, 2023; originally announced October 2023.

  4. arXiv:2207.01491  [pdf

    physics.med-ph physics.optics

    Contrast mechanisms in pump-probe microscopy of melanin

    Authors: David Grass, Georgia M. Beasley, Martin C. Fischer, M. Angelica Selim, Yue Zhou, Warren S. Warren

    Abstract: Pump-probe microscopy of melanin in tumors has been proposed to improve diagnosis of malignant melanoma, based on the hypothesis that aggressive cancers disaggregate melanin structure. However, measured signals of melanin are complex superpositions of multiple nonlinear processes, which makes interpretation challenging. Polarization control during measurement and data fitting is used to decompose… ▽ More

    Submitted 1 July, 2022; originally announced July 2022.

    Comments: 12 pages, 4 figures

  5. arXiv:2012.09215  [pdf

    physics.optics cond-mat.mtrl-sci physics.bio-ph

    Beyond intensity modulation: new approaches to pump-probe microscopy

    Authors: Jun Jiang, David Grass, Yue Zhou, Warren S. Warren, Martin C. Fischer

    Abstract: Pump-probe microscopy is an emerging nonlinear imaging technique based on high repetition rate lasers and fast intensity modulation. Here we present new methods for pump-probe microscopy that keep the beam intensity constant and instead modulate the inter-pulse time delay, the relative polarization, or the pulse length. These techniques can improve image quality for samples that have poor heat dis… ▽ More

    Submitted 18 December, 2020; v1 submitted 16 December, 2020; originally announced December 2020.

  6. arXiv:2001.09906  [pdf

    physics.optics physics.bio-ph

    Crossed-beam pump-probe microscopy

    Authors: Jun Jiang, Warren S. Warren, Martin C. Fischer

    Abstract: We present a new imaging method for pump-probe microscopy that explores non-collinear excitation. This method (crossed-beam pump-probe microscopy, or CBPM) can significantly improve the axial resolution when imaging through low-NA lenses, providing an alternative way for depth resolved, large field-of-view imaging. We performed a proof-of-concept demonstration, characterized CBPM's resolution usin… ▽ More

    Submitted 27 January, 2020; originally announced January 2020.

    Comments: 9 pages, 6 figures

  7. arXiv:1107.5432  [pdf, ps, other

    quant-ph physics.optics

    Controllable ultra-broadband slow light in a warm Rubidium vapor

    Authors: Rui Zhang, Joel A. Greenberg, Martin C. Fischer, Daniel J. Gauthier

    Abstract: We study ultra-broadband slow light in a warm Rubidium vapor cell. By working between the D1 and D2 transitions, we find a several-nm window centered at 788.4 nm in which the group index is highly uniform and the absorption is small (<1%). We demonstrate that we can control the group delay by varying the temperature of the cell, and observe a tunable fractional delay of 18 for pulses as short as 2… ▽ More

    Submitted 27 July, 2011; originally announced July 2011.

    Comments: The first two authors contributed equally to this work