-
Elastic wavepackets crossing a space-time interface
Authors:
Alexandre Delory,
Claire Prada,
Maxime Lanoy,
Antonin Eddi,
Mathias Fink,
Fabrice Lemoult
Abstract:
The interaction between waves and evolving media challenges traditional conservation laws. We experimentally investigate the behavior of elastic wave packets crossing a moving interface that separates two media with distinct propagation properties, observing the non-conservation of wavelength and frequency. Our experimental setup employs an elastic strip whose local stretching can be dynamically a…
▽ More
The interaction between waves and evolving media challenges traditional conservation laws. We experimentally investigate the behavior of elastic wave packets crossing a moving interface that separates two media with distinct propagation properties, observing the non-conservation of wavelength and frequency. Our experimental setup employs an elastic strip whose local stretching can be dynamically altered by pulling one end at a constant velocity. By demonstrating that this dynamic configuration creates a spatio-temporal interface traveling along the strip, we confirm theoretical predictions regarding observed shifts when a wave packet crosses this interface.
△ Less
Submitted 21 June, 2024;
originally announced June 2024.
-
Towards optimal spatiotemporal wavefront sha** for the cocktail party problem with inverse design of an acoustic reconfigurable metasurface in disordered media
Authors:
Raphael Pestourie,
Constant Bourdeloux,
Fabrice Lemoult,
Mathias Fink,
Steven G. Johnson
Abstract:
Multiple-user multiple-input multiple-output applications have recently gained a lot of attention. Here, we show an efficient optimization formulation for the design of all the temporal and spatial degrees of freedom of an acoustic reconfigurable metasurface for the cocktail party problem. In the frequency domain, the closed-form least square solution matches the optimal time reversal solution for…
▽ More
Multiple-user multiple-input multiple-output applications have recently gained a lot of attention. Here, we show an efficient optimization formulation for the design of all the temporal and spatial degrees of freedom of an acoustic reconfigurable metasurface for the cocktail party problem. In the frequency domain, the closed-form least square solution matches the optimal time reversal solution for multiple emitter-receiver pairs, optimizing for each frequency independently. This is more efficient than solving in the time domain where the time convolution mixes all the degrees of freedom into a resource-intensive optimization. We illustrate this methodology by optimizing the frequency response of a design for two pairs of emitters-receivers using the Green's functions of disordered media that are measured experimentally. We report strong performance that will be put in perspective in future work, where we will analyze the robustness of the design to noise in the data and design the convolutional filters that match the optimal frequency response for experiment validation of the design.
△ Less
Submitted 23 March, 2024;
originally announced March 2024.
-
Exploiting spacetime symmetry in dissipative nonlinear multimode amplifiers for output control
Authors:
Chun-Wei Chen,
Kabish Wisal,
Mathias Fink,
A. Douglas Stone,
Hui Cao
Abstract:
Time-reversal symmetry enables sha** input waves to control output waves in many linear and nonlinear systems; however energy dissipation violates such symmetry. We consider a saturated multimode fiber amplifier in which light generates heat flow and suffers nonlinear thermo-optical scattering, breaking time-reversal symmetry. We identify a spacetime symmetry which maps the target output back to…
▽ More
Time-reversal symmetry enables sha** input waves to control output waves in many linear and nonlinear systems; however energy dissipation violates such symmetry. We consider a saturated multimode fiber amplifier in which light generates heat flow and suffers nonlinear thermo-optical scattering, breaking time-reversal symmetry. We identify a spacetime symmetry which maps the target output back to an input field. This map** employs phase conjugation, gain and absorption substitution but not time reversal, and holds in steady-state and for slowly varying inputs. Our results open the possibility of output control of a saturated multimode fiber amplifier.
△ Less
Submitted 15 February, 2024;
originally announced February 2024.
-
Temporal chirp, temporal lensing and temporal routing via space-time interfaces
Authors:
Victor Pacheco-Peña,
Mathias Fink,
Nader Engheta
Abstract:
A time interface (a rapid change of the constitutive parameters of a material in time), applied within an unbounded medium where a wave travels, can enable frequency conversion, and is considered the temporal analogue of a spatial interface between two materials. Here, we study light-matter interactions in four dimensions, 4D (space, x,y,z, and time, t), by exploring the implications of applying t…
▽ More
A time interface (a rapid change of the constitutive parameters of a material in time), applied within an unbounded medium where a wave travels, can enable frequency conversion, and is considered the temporal analogue of a spatial interface between two materials. Here, we study light-matter interactions in four dimensions, 4D (space, x,y,z, and time, t), by exploring the implications of applying time interfaces not to the entire space where a wave travels, but to certain regions of space in order to create spatial interfaces in time. Different configurations such as induced perpendicular, parallel, and oblique spatial interfaces via a temporal interface are discussed. It is shown how such four-dimensional combinations of temporal and spatial interfaces can enable interesting features such as the 4D generalized Snell law and the temporal chirp, temporal lensing, and temporal routing of electromagnetic waves. Such exotic possibilities may provide new ways to manipulate light-matter interactions via a combination of temporal and spatial interfaces.
△ Less
Submitted 17 November, 2023;
originally announced November 2023.
-
Topology Optimization for Microwave Control With Reconfigurable Intelligent Metasurfaces In Complex Media
Authors:
Theodosios D. Karamanos,
Mathias Fink,
Fabrice Lemoult
Abstract:
Reconfigurable intelligent metasurfaces have been proposed as an efficient solution for improving wireless telecommunication systems in multiple scattering or reverberating media. Concurrently, topology optimization has been successfully employed as an inverse design technique in many fields, and particularly in electromagnetics. In this work, we apply a gradient-based topology optimization for tu…
▽ More
Reconfigurable intelligent metasurfaces have been proposed as an efficient solution for improving wireless telecommunication systems in multiple scattering or reverberating media. Concurrently, topology optimization has been successfully employed as an inverse design technique in many fields, and particularly in electromagnetics. In this work, we apply a gradient-based topology optimization for tuning the binary elements of a metasurface for a focusing goal in a complex environment. First, the metasurface unit-cells are approximated as point sources and, then, the optimization problem is formulated. Afterwards, the proposed method is applied to find the optimal parameter sets on three distinct environments of an ascending complexity and the resulting focus for each case is demonstrated via simulations. The combination of reverberating cavity and a metasurface inside the latter reveals very powerful since everything can be solved analytically for focusing outside the cavity.
△ Less
Submitted 6 November, 2023;
originally announced November 2023.
-
Unveiling the deep plumbing system of a volcano by a reflection matrix analysis of seismic noise
Authors:
Elsa Giraudat,
Arnaud Burtin,
Arthur Le Ber,
Mathias Fink,
Jean-Christophe Komorowski,
Alexandre Aubry
Abstract:
In geophysics, volcanoes are particularly difficult to image because of the multi-scale heterogeneities of fluids and rocks that compose them and their complex non-linear dynamics. By exploiting seismic noise recorded by a sparse array of geophones, we are able to reveal the magmatic and hydrothermal plumbing system of La Soufrière volcano in Guadeloupe. Spatio-temporal cross-correlation of seismi…
▽ More
In geophysics, volcanoes are particularly difficult to image because of the multi-scale heterogeneities of fluids and rocks that compose them and their complex non-linear dynamics. By exploiting seismic noise recorded by a sparse array of geophones, we are able to reveal the magmatic and hydrothermal plumbing system of La Soufrière volcano in Guadeloupe. Spatio-temporal cross-correlation of seismic noise actually provides the impulse responses between virtual geophones located inside the volcano. The resulting reflection matrix can be exploited to numerically perform an auto-focus of seismic waves on any reflector of the underground. An unprecedented view on the volcano's inner structure is obtained at a half-wavelength resolution. This innovative observable provides fundamental information for the conceptual modeling and high-resolution monitoring of volcanoes.
△ Less
Submitted 2 November, 2023;
originally announced November 2023.
-
Multi-Spectral Reflection Matrix for Ultra-Fast 3D Label-Free Microscopy
Authors:
Paul Balondrade,
Victor Barolle,
Nicolas Guigui,
Emeric Auriant,
Nathan Rougier,
Claude Boccara,
Mathias Fink,
Alexandre Aubry
Abstract:
Label-free microscopy exploits light scattering to obtain a three-dimensional image of biological tissues. However, light propagation is affected by aberrations and multiple scattering, which drastically degrade the image quality and limit the penetration depth. Multi-conjugate adaptive optics and time-gated matrix approaches have been developed to compensate for aberrations but the associated fra…
▽ More
Label-free microscopy exploits light scattering to obtain a three-dimensional image of biological tissues. However, light propagation is affected by aberrations and multiple scattering, which drastically degrade the image quality and limit the penetration depth. Multi-conjugate adaptive optics and time-gated matrix approaches have been developed to compensate for aberrations but the associated frame rate is extremely limited for 3D imaging. Here we develop a multi-spectral matrix approach to solve these fundamental problems. Based on an interferometric measurement of a polychromatic reflection matrix, the focusing process can be optimized in post-processing at any voxel by addressing independently each frequency component of the wave-field. A proof-of-concept experiment demonstrates the three-dimensional image of an opaque human cornea over a 0.1 mm^3-field-of-view at a 290 nm-resolution and a 1 Hz-frame rate. This work paves the way towards a fully-digital microscope allowing real-time, in-vivo, quantitative and deep inspection of tissues.
△ Less
Submitted 17 October, 2023; v1 submitted 19 September, 2023;
originally announced September 2023.
-
Optimizing multi-user indoor sound communications with acoustic reconfigurable metasurfaces
Authors:
Hongkuan Zhang,
Qiyuan Wang,
Mathias Fink,
Guancong Ma
Abstract:
Sound in indoor spaces forms a complex wavefield due to multiple scattering encountered by the sound. Indoor acoustic communication involving multiple sources and receivers thus inevitably suffers from cross-talks. Here, we demonstrate the isolation of acoustic communication channels in a room by wavefield sha** using acoustic reconfigurable metasurfaces (ARMs) controlled by optimization protoco…
▽ More
Sound in indoor spaces forms a complex wavefield due to multiple scattering encountered by the sound. Indoor acoustic communication involving multiple sources and receivers thus inevitably suffers from cross-talks. Here, we demonstrate the isolation of acoustic communication channels in a room by wavefield sha** using acoustic reconfigurable metasurfaces (ARMs) controlled by optimization protocols based on communication theories. The ARMs have 200 electrically switchable units, each selectively offering 0 or π phase shifts in the reflected waves. The sound field is reshaped for maximal Shannon capacity and minimal cross-talk simultaneously. We demonstrate diverse acoustic functionalities over a spectrum much larger than the coherence bandwidth of the room, including multi-channel, multi-spectral channel isolations, and frequency-multiplexed acoustic communication. Our work shows that wavefield sha** in complex media can offer new strategies for future acoustic engineering.
△ Less
Submitted 10 February, 2024; v1 submitted 3 August, 2023;
originally announced August 2023.
-
Development of the front-end electronics for a cost-effective PET-like detector system
Authors:
Josephine Oppotsch,
Nadia Böhle,
Thomas Held,
Mario Fink,
Miriam Fritsch,
Fritz-Herbert Heinsius,
Matthias Steinke,
Ulrich Wiedner
Abstract:
Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall cost of a PEPT-capable detector system by using large and cost-effective plastic scintillators and develo** custom 2 x 2 silicon photomultiplier (SiPM) arrays…
▽ More
Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall cost of a PEPT-capable detector system by using large and cost-effective plastic scintillators and develo** custom 2 x 2 silicon photomultiplier (SiPM) arrays, preamplifiers, and discriminators. The use of long (20 mm x 20 mm x 1000 mm) plastic scintillator bars read out with photodetectors only at their respective ends allows an overall smaller number of photodetectors and associated readout electronics, which in turn reduces the overall cost of the system. In addition, the development of a custom SiPM array and preamplifier allows a free selection of interconnection and readout, as most commercial producers only offer specific types of interconnections and therefore lack other connections such as serial or hybrid. Thus, several common circuit types for SiPMs and preamplifiers were tested and compared in this work, and it was found that a serial connection implemented in a hybrid interconnection for the SiPMs and an inverting preamplifier based on a high-frequency operational amplifier provided the best results for the proposed detector system. Measured with a Na-22 source, the combination of SiPM array and preamplifier led to a rise time of 3.7 ns and a signal amplitude of 175 mV.
△ Less
Submitted 28 October, 2023; v1 submitted 30 June, 2023;
originally announced June 2023.
-
Subwavelength pulse focusing and perfect absorption in the Maxwell fisheye
Authors:
Gautier Lefebvre,
Marc Dubois,
Younes Achaoui,
Ros Kiri Ing,
Mathias Fink,
Sébastien Guenneau,
Patrick Sebbah
Abstract:
Maxwell's fisheye is a paradigm for an absolute optical instrument with a refractive index deduced from the stereographic projection of a sphere on a plane. We investigate experimentally the dynamics of flexural waves in a thin plate with a thickness varying according to the Maxwell fisheye index profile and a clamped boundary. We demonstrate subwavelength focusing and temporal pulse compression a…
▽ More
Maxwell's fisheye is a paradigm for an absolute optical instrument with a refractive index deduced from the stereographic projection of a sphere on a plane. We investigate experimentally the dynamics of flexural waves in a thin plate with a thickness varying according to the Maxwell fisheye index profile and a clamped boundary. We demonstrate subwavelength focusing and temporal pulse compression at the image point. This is achieved by introducing a sink emitting a cancelling signal optimally shaped using a time-reversal procedure. Perfect absorption and outward going wave cancellation at the focus point are demonstrated. The time evolution of the kinetic energy stored inside the cavity reveals that the sink absorbs energy out of the plate ten times faster than the natural decay rate.
△ Less
Submitted 23 June, 2023;
originally announced June 2023.
-
Imaging the dynamics of cardiac fiber orientation in vivo using 3D Ultrasound Backscatter Tensor Imaging
Authors:
Clement Papadacci,
Victor Finel,
Jean Provost,
Olivier Villemain,
Patrick Bruneval,
Jean-Luc Gennisson,
Mickael Tanter,
Mathias Fink,
Mathieu Pernot
Abstract:
The assessment of myocardial fiber disarray is of major interest for the study of the progression of myocardial disease. However, time-resolved imaging of the myocardial structure remains unavailable in clinical practice. In this study, we introduce 3D Backscatter Tensor Imaging (3D-BTI), an entirely novel ultrasound-based imaging technique that can map the myocardial fibers orientation and its dy…
▽ More
The assessment of myocardial fiber disarray is of major interest for the study of the progression of myocardial disease. However, time-resolved imaging of the myocardial structure remains unavailable in clinical practice. In this study, we introduce 3D Backscatter Tensor Imaging (3D-BTI), an entirely novel ultrasound-based imaging technique that can map the myocardial fibers orientation and its dynamics with a temporal resolution of 10 ms during a single cardiac cycle, non-invasively and in vivo in entire volumes. 3D-BTI is based on ultrafast volumetric ultrasound acquisitions, which are used to quantify the spatial coherence of backscattered echoes at each point of the volume. The capability of 3D-BTI to map the fibers orientation was evaluated in vitro in 5 myocardial samples. The helicoidal transmural variation of fiber angles was in good agreement with the one obtained by histological analysis. 3D-BTI was then performed to map the fiber orientation dynamics in vivo in the beating heart of an open-chest sheep at a volume rate of 90 volumes/s. Finally, the clinical feasibility of 3D-BTI was shown on a healthy volunteer. These initial results indicate that 3D-BTI could become a fully non-invasive technique to assess myocardial disarray at the bedside of patients.
△ Less
Submitted 19 April, 2023;
originally announced April 2023.
-
Three-Dimensional Ultrasound Matrix Imaging
Authors:
Flavien Bureau,
Justine Robin,
Arthur Le Ber,
William Lambert,
Mathias Fink,
Alexandre Aubry
Abstract:
Matrix imaging paves the way towards a next revolution in wave physics. Based on the response matrix recorded between a set of sensors, it enables an optimized compensation of aberration phenomena and multiple scattering events that usually drastically hinder the focusing process in heterogeneous media. Although it gave rise to spectacular results in optical microscopy or seismic imaging, the succ…
▽ More
Matrix imaging paves the way towards a next revolution in wave physics. Based on the response matrix recorded between a set of sensors, it enables an optimized compensation of aberration phenomena and multiple scattering events that usually drastically hinder the focusing process in heterogeneous media. Although it gave rise to spectacular results in optical microscopy or seismic imaging, the success of matrix imaging has been so far relatively limited with ultrasonic waves because wave control is generally only performed with a linear array of transducers. In this paper, we extend ultrasound matrix imaging to a 3D geometry. Switching from a 1D to a 2D probe enables a much sharper estimation of the transmission matrix that links each transducer and each medium voxel. Here, we first present an experimental proof of concept on a tissue-mimicking phantom through ex-vivo tissues and then, show the potential of 3D matrix imaging for transcranial applications.
△ Less
Submitted 17 October, 2023; v1 submitted 13 March, 2023;
originally announced March 2023.
-
Non-invasive Retrieval of the Time-Gated Transmission Matrix for Optical Imaging Deep Inside a Multiple Scattering Medium
Authors:
Ulysse Najar,
Victor Barolle,
Paul Balondrade,
Mathias Fink,
A. Claude Boccara,
Alexandre Aubry
Abstract:
As light travels through a disordered medium such as biological tissues, it undergoes multiple scattering events. This phenomenon is detrimental to in-depth optical microscopy, as it causes a drastic degradation of contrast, resolution and brightness of the resulting image beyond a few scattering mean free paths. However, the information about the inner reflectivity of the sample is not lost; only…
▽ More
As light travels through a disordered medium such as biological tissues, it undergoes multiple scattering events. This phenomenon is detrimental to in-depth optical microscopy, as it causes a drastic degradation of contrast, resolution and brightness of the resulting image beyond a few scattering mean free paths. However, the information about the inner reflectivity of the sample is not lost; only scrambled. To recover this information, a matrix approach of optical imaging can be fruitful. Here we report on a de-scanned measurement of a high-dimension reflection matrix R via low coherence interferometry. Then, we show how the time-gated transmission matrix linking each camera sensor and each medium voxel can be extracted through an iterative multi-scale analysis of wave distortions contained in R. This transmission matrix is the Holy Grail for volumetric imaging since it enables an optimal compensation of forward multiple scattering paths and provides a three-dimensional confocal image of the sample as the latter one had become digitally transparent. The proof-of-concept experiment is performed on a human opaque cornea and an extension of the penetration depth by a factor five is demonstrated compared to the state-of-the-art.
△ Less
Submitted 5 October, 2023; v1 submitted 10 March, 2023;
originally announced March 2023.
-
Entangling microwaves with optical light
Authors:
Rishabh Sahu,
Liu Qiu,
William Hease,
Georg Arnold,
Yuri Minoguchi,
Peter Rabl,
Johannes M. Fink
Abstract:
Entanglement is a genuine quantum mechanical property and the key resource in currently developed quantum technologies. Sharing this fragile property between superconducting microwave circuits and optical or atomic systems would enable new functionalities but has been hindered by the tremendous energy mismatch of $\sim10^5$ and the resulting mutually imposed loss and noise. In this work we create…
▽ More
Entanglement is a genuine quantum mechanical property and the key resource in currently developed quantum technologies. Sharing this fragile property between superconducting microwave circuits and optical or atomic systems would enable new functionalities but has been hindered by the tremendous energy mismatch of $\sim10^5$ and the resulting mutually imposed loss and noise. In this work we create and verify entanglement between microwave and optical fields in a millikelvin environment. Using an optically pulsed superconducting electro-optical device, we deterministically prepare an itinerant microwave-optical state that is squeezed by $0.72^{+0.31}_{-0.25}$\,dB and violates the Duan-Simon separability criterion by $>5$ standard deviations. This establishes the long-sought non-classical correlations between superconducting circuits and telecom wavelength light with wide-ranging implications for hybrid quantum networks in the context of modularization, scaling, sensing and cross-platform verification.
△ Less
Submitted 9 January, 2023;
originally announced January 2023.
-
Coherent optical control of a superconducting microwave cavity via electro-optical dynamical back-action
Authors:
Liu Qiu,
Rishabh Sahu,
William Hease,
Georg Arnold,
Johannes M. Fink
Abstract:
Recent quantum technologies have established precise quantum control of various microscopic systems using electromagnetic waves. Interfaces based on cryogenic cavity electro-optic systems are particularly promising, due to the direct interaction between microwave and optical fields in the quantum regime. Quantum optical control of superconducting microwave circuits has been precluded so far due to…
▽ More
Recent quantum technologies have established precise quantum control of various microscopic systems using electromagnetic waves. Interfaces based on cryogenic cavity electro-optic systems are particularly promising, due to the direct interaction between microwave and optical fields in the quantum regime. Quantum optical control of superconducting microwave circuits has been precluded so far due to the weak electro-optical coupling as well as quasi-particles induced by the pump laser. Here we report the coherent control of a superconducting microwave cavity using laser pulses in a multimode electro-optical device at millikelvin temperature with near-unity cooperativity. Both the stationary and instantaneous responses of the microwave and optical modes comply with the coherent electro-optical interaction, and reveal only minuscule amount of excess back-action with an unanticipated time delay. Our demonstration enables wide ranges of applications beyond quantum transductions, from squeezing and quantum non-demolition measurements of microwave fields, to entanglement generation and hybrid quantum networks.
△ Less
Submitted 25 June, 2023; v1 submitted 22 October, 2022;
originally announced October 2022.
-
Super-resolved imaging based on spatiotemporal wavefront sha**
Authors:
Guillaume Noetinger,
Samuel Métais,
Geoffroy Lerosey,
Mathias Fink,
Sébastien M. Popoff,
Fabrice Lemoult
Abstract:
A novel approach to improving the performances of confocal scanning imaging is proposed. We experimentally demonstrate its feasibility using acoustic waves. It relies on a new way to encode spatial information using the temporal dimension. By moving an emitter, used to insonify an object, along a circular path, we create a temporally modulated wavefield. Due to the cylindrical symmetry of the prob…
▽ More
A novel approach to improving the performances of confocal scanning imaging is proposed. We experimentally demonstrate its feasibility using acoustic waves. It relies on a new way to encode spatial information using the temporal dimension. By moving an emitter, used to insonify an object, along a circular path, we create a temporally modulated wavefield. Due to the cylindrical symmetry of the problem and its temporal periodicity, the spatiotemporal input field can be decomposed into harmonics corresponding to different spatial vortices, or topological charges. Acquiring the back-reflected waves with receivers which are also rotating, multiple images of the same object with different Point Spread Functions (PSFs) are obtained. Not only is the resolution improved compared to a standard confocal configuration, but the accumulation of information also allows building images beating the diffraction limit. The topological robustness of the approach promises good performances in real life conditions.
△ Less
Submitted 21 October, 2022;
originally announced October 2022.
-
Compact orthogonal view OCT: clinical exploration of human trabecular meshwork and cornea at cell resolution
Authors:
Viacheslav Mazlin,
Kristina Irsch,
Vincent Borderie,
Christophe Baudouin,
Michel Paques,
Mathias Fink,
Kate Grieve,
Albert Claude Boccara
Abstract:
Glaucoma remains among the leading causes of blindness despite many treatment options available today. Effective treatment requires early diagnosis, which is difficult to achieve with existing imaging technologies that detect the already inflicted irreversible posterior eye damage. One improved approach could be to detect the changes in trabecular meshwork of the anterior eye that precede the intr…
▽ More
Glaucoma remains among the leading causes of blindness despite many treatment options available today. Effective treatment requires early diagnosis, which is difficult to achieve with existing imaging technologies that detect the already inflicted irreversible posterior eye damage. One improved approach could be to detect the changes in trabecular meshwork of the anterior eye that precede the intraocular pressure buildup and vision loss. Here we report a device that enables in vivo exploration of trabecular meshwork at cell resolution. The instrument combines two orthogonal views: en face view of time-domain full-field OCT for high-resolution and cross-sectional view of spectral-domain OCT for aligning to the meshwork. The device resolves micron-level corneoscleral and uveal pores, meshwork beams and internal elastic fibers, ciliary body tendons and trabecular cell nuclei. Capable of detecting blockage of trabecular pores, orthogonal view OCT presents a promising solution to the long-standing problem of early glaucoma diagnosis. Future clinical adoption of the device is facilitated by the compact footprint and broad functionality that includes corneal imaging in healthy subjects and patients (with keratoconus, Fuchs endothelial dystrophy) using the same design.
△ Less
Submitted 12 September, 2022;
originally announced September 2022.
-
Full-Waveform Modeling for Time-of-Flight Measurements based on Arrival Time of Photons
Authors:
Maximilian Fink,
Michael Schardt,
Valentin Baier,
Kun Wang,
Martin Jakobi,
Alexander W. Koch
Abstract:
Modern LiDAR sensors find increasing use in safety-critical applications. Therefore, highly accurate modeling of the system's behavior under demanding environmental conditions is necessary. In this paper, we present a modular structure to accurately simulate the amplified raw detector signal of a direct time-of-flight LiDAR system for coaxial transmitter-receiver optics. Our model describes, a mea…
▽ More
Modern LiDAR sensors find increasing use in safety-critical applications. Therefore, highly accurate modeling of the system's behavior under demanding environmental conditions is necessary. In this paper, we present a modular structure to accurately simulate the amplified raw detector signal of a direct time-of-flight LiDAR system for coaxial transmitter-receiver optics. Our model describes, a measurement system based on standard optical components and a detector able of converting single photons to an electrical signal. To verify the model's predictions, single-point measurements for targets of different reflectivity at defined distances were performed. Statistical analysis shows an R-squared value greater than 0.990 for simulated and measured signal amplitude levels. Noise modeling shows good accordance with the performed measurements for different target irradiance levels. The presented results have a guiding significance in the modeling of the complex signal processing chain of LiDAR systems, as it enables the prediction of key parameters of the system early in the development process. Hence, unnecessary costs by design flaws can be mitigated. The modular structure allows easy adaption for arbitrary LiDAR systems.
△ Less
Submitted 3 August, 2022;
originally announced August 2022.
-
Tunable directional photon scattering from a pair of superconducting qubits
Authors:
Elena S. Redchenko,
Alexander V. Poshakinskiy,
Riya Sett,
Martin Zemlicka,
Alexander N. Poddubny,
Johannes M. Fink
Abstract:
The ability to control the direction of scattered light in integrated devices is crucial to provide the flexibility and scalability for a wide range of on-chip applications, such as integrated photonics, quantum information processing and nonlinear optics. In the optical and microwave frequency ranges tunable directionality can be achieved by applying external magnetic fields, that modify optical…
▽ More
The ability to control the direction of scattered light in integrated devices is crucial to provide the flexibility and scalability for a wide range of on-chip applications, such as integrated photonics, quantum information processing and nonlinear optics. In the optical and microwave frequency ranges tunable directionality can be achieved by applying external magnetic fields, that modify optical selection rules, by using nonlinear effects, or interactions with vibrations. However, these approaches are less suitable to control propagation of microwave photons inside integrated superconducting quantum devices, that is highly desirable. Here, we demonstrate tunable directional scattering with just two transmon qubits coupled to a transmission line based on periodically modulated transition frequency. By changing the symmetry of the modulation, governed by the relative phase between the local modulation tones, we achieve directional forward or backward photon scattering.
△ Less
Submitted 6 May, 2022;
originally announced May 2022.
-
Fiber-optic multimode interference sensing: comprehensive characterization and its potential for strain-insensitive temperature sensing
Authors:
Kun Wang,
Yosuke Mizuno,
Xingchen Dong,
Wolfgang Kurz,
Maximilian Fink,
Heeyoung Lee,
Martin Jakobi,
Alexander W. Koch
Abstract:
A strain-insensitive temperature sensor based on multimode interference using standard multimode fibers (MMFs) is proposed according to the comprehensive study of the characteristics of the MMFs. The temperature and strain dependences on the core diameter, numerical aperture (NA), and the length of the MMF section in the single-mode--multimode--single-mode (SMS) fiber structure are investigated ex…
▽ More
A strain-insensitive temperature sensor based on multimode interference using standard multimode fibers (MMFs) is proposed according to the comprehensive study of the characteristics of the MMFs. The temperature and strain dependences on the core diameter, numerical aperture (NA), and the length of the MMF section in the single-mode--multimode--single-mode (SMS) fiber structure are investigated experimentally. The results indicate that the larger core diameter of the MMF leads to higher temperature sensitivity but lower strain sensitivity (absolute values); the higher NA does not influence the temperature sensitivity but results in higher absolute value of strain sensitivity; the longer MMF section brings lower temperature sensitivity but does not have an impact on strain sensitivity. These findings also contribute to the theoretical analysis of the length dependence in the SMS fiber sensors. Besides, the results of the characterization study show that the strain sensitivity is relatively low, which brings a possibility to develop a strain-insensitive temperature sensor. The proposed sensor is used for temperature sensing while the strain is constantly applied from 0 to 1100 $με$ with steps of 100 $με$. The measured results are consistent with the comprehensive study. The mean temperature sensitivity is 6.14 pm/$^{\circ}$C with a standard deviation of 0.39 pm/$^{\circ}$C, which proves that the proposed temperature sensor exhibits good stability and is insensitive to strain. We expect that these results will provide a profound guideline to fiber sensors based on multimode interference.
△ Less
Submitted 23 April, 2022;
originally announced April 2022.
-
Smart Radio Environments
Authors:
Gabriele Gradoni,
Marco Di Renzo,
Ana Diaz-Rubio,
Sergei Tretyakov,
Christophe Caloz,
Zhen Peng,
Andrea Alu,
Geoffroy Lerosey,
Mathias Fink,
Vincenzo Galdi,
Tie Jun Cui,
Benjamin Frazier,
Steven Anlage,
Marco Salucci,
Andrea Massa,
Qiang Cheng,
**ghe Wang,
Shi **,
Davide Dardari,
Nicolo Decarli,
Okan Yurduseven,
Michail Matthaiou,
Mitchell Kenney,
George Gordon,
Orestis Georgiou
, et al. (5 additional authors not shown)
Abstract:
This Roadmap takes the reader on a journey through the research in electromagnetic wave propagation control via reconfigurable intelligent surfaces. Meta-surface modelling and design methods are reviewed along with physical realisation techniques. Several wireless applications are discussed, including beam-forming, focusing, imaging, localisation, and sensing, some rooted in novel architectures fo…
▽ More
This Roadmap takes the reader on a journey through the research in electromagnetic wave propagation control via reconfigurable intelligent surfaces. Meta-surface modelling and design methods are reviewed along with physical realisation techniques. Several wireless applications are discussed, including beam-forming, focusing, imaging, localisation, and sensing, some rooted in novel architectures for future mobile communications networks towards 6G.
△ Less
Submitted 16 November, 2021;
originally announced November 2021.
-
Optical phase modulation by natural eye movements: application to time-domain FF-OCT image retrieval
Authors:
Viacheslav Mazlin,
Peng Xiao,
Kristina Irsch,
Jules Scholler,
Kassandra Groux,
Kate Grieve,
Mathias Fink,
Albert Claude Boccara
Abstract:
Eye movements are commonly seen as an obstacle to high-resolution ophthalmic imaging. In this context we study the natural axial movements of the in vivo human eye and show that they can be used to modulate the optical phase and retrieve tomographic images via time-domain full-field optical coherence tomography (TD-FF-OCT). This approach opens a path to a simplified ophthalmic TD-FF-OCT device, op…
▽ More
Eye movements are commonly seen as an obstacle to high-resolution ophthalmic imaging. In this context we study the natural axial movements of the in vivo human eye and show that they can be used to modulate the optical phase and retrieve tomographic images via time-domain full-field optical coherence tomography (TD-FF-OCT). This approach opens a path to a simplified ophthalmic TD-FF-OCT device, operating without the usual piezo motor-camera synchronization. The device demonstrates in vivo human corneal images under the different image retrieval schemes (2-phase and 4-phase) and different exposure times (3.5 ms, 10 ms, 20 ms). Data on eye movements, acquired with a 100 kHz spectral-domain OCT with axial eye tracking, are used to study the influence of ocular motion on the probability of capturing high-signal tomographic images without phase washout. The optimal combinations of camera acquisition speed and amplitude of piezo modulation are proposed and discussed.
△ Less
Submitted 18 October, 2021;
originally announced October 2021.
-
Freeze-dried microfluidic monodisperse microbubbles as a new generation of ultrasound contrast agents
Authors:
Ugur Soysal,
Pedro N. Azevedo,
Flavien Bureau,
Alexandre Aubry,
Marcio S. Carvalho,
Amanda C. S. N. Pessoa,
Lucimara G. De la Torre,
Olivier Couture,
Arnaud Tourin,
Mathias Fink,
Patrick Tabeling
Abstract:
In the paper, we succeeded to freeze-dry monodisperse microbubbles without degrading their size and acoustic properties. We used microfluidic technology to generate highly monodisperse (coefficient of variation, CV<5%) microbubbles and optimized their formulation along with a cryoprotectant. By using a specific technique of retrieval of the bubble, we showed that freeze-drying the microbubbles doe…
▽ More
In the paper, we succeeded to freeze-dry monodisperse microbubbles without degrading their size and acoustic properties. We used microfluidic technology to generate highly monodisperse (coefficient of variation, CV<5%) microbubbles and optimized their formulation along with a cryoprotectant. By using a specific technique of retrieval of the bubble, we showed that freeze-drying the microbubbles does not alter their size distribution. To compare the fundamental resonance properties of the bubbles, we performed backscattered acoustic characterization measurements. Our experimental results revealed that the freeze-drying process conserved the acoustic properties of the bubbles. The maximum backscattering power amplitude of fresh and freeze-dried monodisperse PVA bubbles was around ten eight times higher than that of SonoVue at a similar concentration in vitro. By solving the question of storage and transportation of monodisperse bubbles, our work facilitates their penetration in the domain of UCAs, for performing new tasks and develo** novel non-invasive measurements, such as pressure, unaccessible to the existing commercialized bubbles.
△ Less
Submitted 6 August, 2021;
originally announced August 2021.
-
Static-to-dynamic field conversion with time-varying media
Authors:
Mario Junior Mencagli,
Dimitrios L. Sounas,
Mathias Fink,
Nader Engheta
Abstract:
In this Letter, we theoretically demonstrate that a uniform static electric field distribution can be partially converted to radiation fields when a portion of the medium undergoes a temporal change of its permittivity. An in-depth theoretical investigation of this phenomenon is developed for a dielectric block with a step-like temporal change located inside a waveguide charged with a DC voltage s…
▽ More
In this Letter, we theoretically demonstrate that a uniform static electric field distribution can be partially converted to radiation fields when a portion of the medium undergoes a temporal change of its permittivity. An in-depth theoretical investigation of this phenomenon is developed for a dielectric block with a step-like temporal change located inside a waveguide charged with a DC voltage source. Closed analytical expressions are derived for the radiated electric and magnetic fields. The exchange of energy between the electrostatic and electromagnetic fields is discussed. The reconciliation between the seemingly contradictory temporal and spatial boundary conditions for the electric and magnetic fields at the interface of the time-varying dielectric block is analyzed and elucidated. Our findings may provide an alternative solution for generating electromagnetic radiation based on time-varying media.
△ Less
Submitted 23 July, 2021;
originally announced July 2021.
-
Experimental demonstration of a mmWave passive access point extender based on a binary reconfigurable intelligent surface
Authors:
Vladislav Popov,
Mikhail Odit,
Jean-Baptiste Gros,
Vladimir Lenets,
Akira Kumagai,
Mathias Fink,
Kotaro Enomoto,
Geoffroy Lerosey
Abstract:
As data rates demands are exploding, 5G will soon rely on mmWaves that offer much higher bandwidths. Yet at these frequencies, attenuation and diffraction of waves require point to point communications with beamforming base stations that are complex and power greedy. Furthermore, since any obstacle at these frequencies completely blocks the waves, the networks must be extremely dense, resulting in…
▽ More
As data rates demands are exploding, 5G will soon rely on mmWaves that offer much higher bandwidths. Yet at these frequencies, attenuation and diffraction of waves require point to point communications with beamforming base stations that are complex and power greedy. Furthermore, since any obstacle at these frequencies completely blocks the waves, the networks must be extremely dense, resulting in dramatic increase of its cost. One way to avoid this problem is to redirect beams coming from base stations at many locations with Reconfigurable Intelligent Surfaces, in order to increase their coverage even in cluttered environments. Here we describe and experimentally demonstrate a binary tunable metasurface operating at 28~GHz, based on standard PCB and off the shelves PIN diodes. We show that it can be used as a Reconfigurable Intelligent Surface that beamforms an incoming plane wave at a given angle to one or several outgoing plane waves at angles reconfigurable in real time. Most importantly we use this 20~cm$\times$20~cm reconfigurable Intelligent Surface alongside software defined radio and up/down converters at 28~GHz, and demonstrate a wireless link between an emitter and a receiver 10~meters away, in a non line of sight configuration, hence proving the validity of the approach.
△ Less
Submitted 5 July, 2021;
originally announced July 2021.
-
Non invasive live imaging of a novel retinal pigment epithelium stress model with Dynamic Full-Field Optical Coherence Tomography
Authors:
Kassandra Groux,
Anna Verschueren,
Céline Nanteau,
Marilou Clémençon,
Mathias Fink,
José-Alain Sahel,
Claude Boccara,
Michel Paques,
Sacha Reichman,
Kate Grieve
Abstract:
Retinal degenerative diseases lead to the blindness of millions of people around the world. In case of age-related macular degeneration (AMD), the atrophy of retinal pigment epithelium (RPE) precedes neural dystrophy. But as crucial as understanding both healthy and pathological RPE cell physiology is for those diseases, no current technique allows subcellular in vivo or in vitro live observation…
▽ More
Retinal degenerative diseases lead to the blindness of millions of people around the world. In case of age-related macular degeneration (AMD), the atrophy of retinal pigment epithelium (RPE) precedes neural dystrophy. But as crucial as understanding both healthy and pathological RPE cell physiology is for those diseases, no current technique allows subcellular in vivo or in vitro live observation of this critical cell layer. To fill this gap, we propose dynamic full-field OCT (D-FFOCT) as a candidate for live observation of in vitro RPE phenotype. In this way, we monitored primary porcine and human stem cell-derived RPE cells in stress model conditions by performing scratch assays. In this study, we quantified wound healing parameters on the stressed RPE, and observed different cell phenotypes, displayed by the D-FFOCT signal. In order to decipher the subcellular contributions to these dynamic profiles, we performed immunohistochemistry to identify which organelles generate the signal and found mitochondria to be the main contributor to D-FFOCT contrast. Altogether, D-FFOCT appears to be an innovative method to follow degenerative disease evolution and could be an appreciated method in the future for live patient diagnostics and to direct treatment choice.
△ Less
Submitted 19 June, 2021;
originally announced June 2021.
-
Waveform analysis of human retinal and choroidal blood flow with laser Doppler holography
Authors:
Léo Puyo,
Michel Paques,
Mathias Fink,
José-Alain Sahel,
Michael Atlan
Abstract:
Laser Doppler holography was introduced as a full-field imaging technique to measure blood flow in the retina and choroid with an as yet unrivaled temporal resolution. We here investigate separating the different contributions to the power Doppler signal in order to isolate the flow waveforms of vessels in the posterior pole of the human eye. Distinct flow behaviors are found in retinal arteries a…
▽ More
Laser Doppler holography was introduced as a full-field imaging technique to measure blood flow in the retina and choroid with an as yet unrivaled temporal resolution. We here investigate separating the different contributions to the power Doppler signal in order to isolate the flow waveforms of vessels in the posterior pole of the human eye. Distinct flow behaviors are found in retinal arteries and veins with seemingly interrelated waveforms. We demonstrate a full field map** of the local resistivity index, and the possibility to perform unambiguous identification of retinal arteries and veins on the basis of their systolodiastolic variations. Finally we investigate the arterial flow waveforms in the retina and choroid and find synchronous and similar waveforms, although with a lower pulsatility in choroidal vessels. This work demonstrates the potential held by laser Doppler holography to study ocular hemodynamics in healthy and diseased eyes.
△ Less
Submitted 1 June, 2021;
originally announced June 2021.
-
Choroidal vasculature imaging with laser Doppler holography
Authors:
Léo Puyo,
Michel Paques,
Mathias Fink,
José-Alain Sahel,
Michael Atlan
Abstract:
The choroid is a highly vascularized tissues supplying the retinal pigment epithelium and photoreceptors. Its implication in retinal diseases is gaining increasing interest. However, investigating the anatomy and flow of the choroid remains challenging. Here we show that laser Doppler holography provides high contrast imaging of choroidal vessels in humans, with a spatial resolution comparable to…
▽ More
The choroid is a highly vascularized tissues supplying the retinal pigment epithelium and photoreceptors. Its implication in retinal diseases is gaining increasing interest. However, investigating the anatomy and flow of the choroid remains challenging. Here we show that laser Doppler holography provides high contrast imaging of choroidal vessels in humans, with a spatial resolution comparable to state of the art indocyanine green angiography and optical coherence tomography. Additionally, laser Doppler holography contributes to sort out choroidal arteries and veins by using a power Doppler spectral analysis. We thus demonstrate the potential of laser Doppler holography to improve our understanding of the anatomy and flow of the choroidal vascular network.
△ Less
Submitted 1 June, 2021;
originally announced June 2021.
-
Ultrasound Matrix Imaging-Part II: The distortion matrix for aberration correction over multiple isoplanatic patches
Authors:
William Lambert,
Laura A. Cobus,
Justine Robin,
Mathias Fink,
Alexandre Aubry
Abstract:
This is the second article in a series of two which report on a matrix approach for ultrasound imaging in heterogeneous media. This article describes the quantification and correction of aberration, i.e. the distortion of an image caused by spatial variations in the medium speed-of-sound. Adaptive focusing can compensate for aberration, but is only effective over a restricted area called the isopl…
▽ More
This is the second article in a series of two which report on a matrix approach for ultrasound imaging in heterogeneous media. This article describes the quantification and correction of aberration, i.e. the distortion of an image caused by spatial variations in the medium speed-of-sound. Adaptive focusing can compensate for aberration, but is only effective over a restricted area called the isoplanatic patch. Here, we use an experimentally-recorded matrix of reflected acoustic signals tosynthesize a set of virtual transducers. We then examine wave propagation between these virtual transducers and an arbitrary correction plane. Such wave-fronts consist of two components: (i) An ideal geometric wave-front linked to diffraction and the input focusing point, and; (ii) Phase distortions induced by the speed-of-sound variations. These distortions are stored in a so-called distortion matrix, the singular value decomposition of which gives access to an optimized focusing law at any point. We show that, by decoupling the aberrations undergone by the outgoing and incoming waves and applying an iterative strategy, compensation for even high-order and spatially-distributed aberrations can be achieved. After a numerical validation of the process, ultrasound matrix imaging (UMI) is applied to the in-vivo imaging of a gallbladder. A map of isoplanatic modes is retrieved and is shown to be strongly correlated with the arrangement of tissues constituting the medium. The corresponding focusing laws yield an ultrasound image with drastically improved contrast and transverse resolution. UMI thus provides a flexible and powerful route towards computational ultrasound.
△ Less
Submitted 3 December, 2022; v1 submitted 2 March, 2021;
originally announced March 2021.
-
Ultrasound Matrix Imaging-Part I: The focused reflection matrix, the F-factor and the role of multiple scattering
Authors:
William Lambert,
Justine Robin,
Laura A. Cobus,
Mathias Fink,
Alexandre Aubry
Abstract:
This is the first article in a series of two dealing with a matrix approach for aberration quantification and correction in ultrasound imaging. Advanced synthetic beamforming relies on a double focusing operation at transmission and reception on each point of the medium. Ultrasound matrix imaging (UMI) consists in decoupling the location of these transmitted and received focal spots. The response…
▽ More
This is the first article in a series of two dealing with a matrix approach for aberration quantification and correction in ultrasound imaging. Advanced synthetic beamforming relies on a double focusing operation at transmission and reception on each point of the medium. Ultrasound matrix imaging (UMI) consists in decoupling the location of these transmitted and received focal spots. The response between those virtual transducers form the so-called focused reflection matrix that actually contains much more information than a confocal ultrasound image. In this paper, a time-frequency analysis of this matrix is performed, which highlights the single and multiple scattering contributions as well as the impact of aberrations in the monochromatic and broadband regimes. Interestingly, this analysis enables the measurement of the incoherent input-output point spread function at any pixel of this image. A fitting process enables the quantification of the single scattering, multiple scattering and noise components in the image. From the single scattering contribution, a focusing criterion is defined, and its evolution used to quantify the amount of aberration throughout the ultrasound image. In contrast to the state-of-the-art coherence factor, this new indicator is robust to multiple scattering and electronic noise, thereby providing a contrasted map of the focusing quality at a much better transverse resolution. After a validation of the proof-of-concept based on time-domain simulations, UMI is applied to the in-vivo study of a human calf. Beyond this specific example, UMI opens a new route for speed-of-sound and scattering quantification in ultrasound imaging.
△ Less
Submitted 3 December, 2022; v1 submitted 2 March, 2021;
originally announced March 2021.
-
Manifestation of aberrations in full-field optical coherence tomography
Authors:
Victor Barolle,
Jules Scholler,
Pedro Mecê,
Jean-Marie Chassot,
Kassandra Groux,
Mathias Fink,
A. Claude Boccara,
Alexandre Aubry
Abstract:
We report on a theoretical model for image formation in full-field optical coherence tomography (FFOCT). Because the spatial incoherence of the illumination acts as a virtual confocal pinhole in FFOCT, its imaging performance is equivalent to a scanning time-gated coherent confocal microscope. In agreement with optical experiments enabling a precise control of aberrations, FFOCT is shown to have n…
▽ More
We report on a theoretical model for image formation in full-field optical coherence tomography (FFOCT). Because the spatial incoherence of the illumination acts as a virtual confocal pinhole in FFOCT, its imaging performance is equivalent to a scanning time-gated coherent confocal microscope. In agreement with optical experiments enabling a precise control of aberrations, FFOCT is shown to have nearly twice the resolution of standard imaging at moderate aberration level. Beyond a rigorous study on the sensitivity of FFOCT with respect to aberrations, this theoretical model paves the way towards an optimized design of adaptive optics and \rev{computational tools} for high-resolution and deep imaging of biological tissues.
△ Less
Submitted 2 July, 2021; v1 submitted 25 January, 2021;
originally announced January 2021.
-
Asymmetric frequency conversion with acoustic non-Hermitian space-time varying metamaterial
Authors:
Xinhua Wen,
Xinghong Zhu,
Alvin Fan,
Wing Yim Tam,
Jie Zhu,
Fabrice Lemoult,
Mathias Fink,
Jensen Li
Abstract:
Space-time modulated metamaterials support extraordinary rich applications, such as parametric amplification, frequency conversion and non-reciprocal transmission. However, experimental realization of space-time modulation is highly non-trivial, hindering many interesting physics that are theoretically predicted to be experimentally demonstrated. Here, based on the proposed virtualized metamateria…
▽ More
Space-time modulated metamaterials support extraordinary rich applications, such as parametric amplification, frequency conversion and non-reciprocal transmission. However, experimental realization of space-time modulation is highly non-trivial, hindering many interesting physics that are theoretically predicted to be experimentally demonstrated. Here, based on the proposed virtualized metamaterials with software-defined impulse response, we experimentally realize non-Hermitian space-time varying metamaterials for efficient and asymmetric frequency conversion by allowing material gain and loss to be tailor-made and balanced in the time domain. In the application of frequency conversion, the combination of space-time varying capability and non-Hermiticity allows us to diminish the main band through gain-loss balance and to increase the efficiency of side band conversion at the same time. In addition, our approach of software-defined metamaterials is flexible to realize the analogy of quantum interference in an acoustic system with design capability. Applying an additional modulation phase delay between different atoms allows to control such interference to get asymmetric amplification in frequency conversion.
△ Less
Submitted 27 September, 2020;
originally announced November 2020.
-
Thermal Noise in Electro-Optic Devices at Cryogenic Temperatures
Authors:
Sonia Mobassem,
Nicholas J. Lambert,
Alfredo Rueda,
Johannes M. Fink,
Gerd Leuchs,
Harald G. L. Schwefel
Abstract:
The quantum bits (qubits) on which superconducting quantum computers are based have energy scales corresponding to photons with GHz frequencies. The energy of photons in the gigahertz domain is too low to allow transmission through the noisy room-temperature environment, where the signal would be lost in thermal noise. Optical photons, on the other hand, have much higher energies, and signals can…
▽ More
The quantum bits (qubits) on which superconducting quantum computers are based have energy scales corresponding to photons with GHz frequencies. The energy of photons in the gigahertz domain is too low to allow transmission through the noisy room-temperature environment, where the signal would be lost in thermal noise. Optical photons, on the other hand, have much higher energies, and signals can be detected using highly efficient single-photon detectors. Transduction from microwave to optical frequencies is therefore a potential enabling technology for quantum devices. However, in such a device the optical pump can be a source of thermal noise and thus degrade the fidelity; the similarity of input microwave state to the output optical state. In order to investigate the magnitude of this effect we model the sub-Kelvin thermal behavior of an electro-optic transducer based on a lithium niobate whispering gallery mode resonator. We find that there is an optimum power level for a continuous pump, whilst pulsed operation of the pump increases the fidelity of the conversion.
△ Less
Submitted 20 August, 2020;
originally announced August 2020.
-
Cavity quantum electro-optics: Microwave-telecom conversion in the quantum ground state
Authors:
William Hease,
Alfredo Rueda,
Rishabh Sahu,
Matthias Wulf,
Georg Arnold,
Harald G. L. Schwefel,
Johannes M. Fink
Abstract:
Fiber optic communication is the backbone of our modern information society, offering high bandwidth, low loss, weight, size and cost, as well as an immunity to electromagnetic interference. Microwave photonics lends these advantages to electronic sensing and communication systems, but - unlike the field of nonlinear optics - electro-optic devices so far require classical modulation fields whose v…
▽ More
Fiber optic communication is the backbone of our modern information society, offering high bandwidth, low loss, weight, size and cost, as well as an immunity to electromagnetic interference. Microwave photonics lends these advantages to electronic sensing and communication systems, but - unlike the field of nonlinear optics - electro-optic devices so far require classical modulation fields whose variance is dominated by electronic or thermal noise rather than quantum fluctuations. Here we present a cavity electro-optic transceiver operating in a millikelvin environment with a mode occupancy as low as 0.025 $\pm$ 0.005 noise photons. Our system is based on a lithium niobate whispering gallery mode resonator, resonantly coupled to a superconducting microwave cavity via the Pockels effect. For the highest continuous wave pump power of 1.48 mW we demonstrate bidirectional single-sideband conversion of X band microwave to C band telecom light with a total (internal) efficiency of 0.03 % (0.7 %) and an added output conversion noise of 5.5 photons. The high bandwidth of 10.7 MHz combined with the observed very slow heating rate of 1.1 noise photons s$^{-1}$ puts quantum limited pulsed microwave-optics conversion within reach. The presented device is versatile and compatible with superconducting qubits, which might open the way for fast and deterministic entanglement distribution between microwave and optical fields, for optically mediated remote entanglement of superconducting qubits, and for new multiplexed cryogenic circuit control and readout strategies.
△ Less
Submitted 26 May, 2020;
originally announced May 2020.
-
Curved-field optical coherence tomography: large-field imaging of human corneal cells and nerves
Authors:
Viacheslav Mazlin,
Kristina Irsch,
Michel Paques,
Mathias Fink,
Albert Claude Boccara
Abstract:
High-resolution optical imaging methods, such as confocal microscopy and full-field optical coherence tomography, capture flat optical sections of the sample. If the sample is curved, the optical field sections through several sample layers and the view of each layer is reduced. Here we present curved-field optical coherence tomography, capable of capturing optical sections of arbitrary curvature.…
▽ More
High-resolution optical imaging methods, such as confocal microscopy and full-field optical coherence tomography, capture flat optical sections of the sample. If the sample is curved, the optical field sections through several sample layers and the view of each layer is reduced. Here we present curved-field optical coherence tomography, capable of capturing optical sections of arbitrary curvature. We test the device on a challenging task of imaging the human cornea in vivo and achieve 10x larger viewing area comparing to the clinical state-of-the-art. This enables more precise cell and nerve counts, opening a path to improved diagnosis of corneal and general health conditions (e.g. diabetes). The method is non-contact, compact and works in a single-shot, making it readily available for use in optical research and clinical practice.
△ Less
Submitted 2 April, 2020;
originally announced April 2020.
-
Real-time, non-contact, cellular imaging and angiography of human cornea and limbus with common-path Full-field/SDOCT
Authors:
Viacheslav Mazlin,
Peng Xiao,
Jules Scholler,
Kristina Irsch,
Kate Grieve,
Mathias Fink,
A. Claude Boccara
Abstract:
In today's clinics, a cellular-resolution view of the cornea can be achieved only with an in vivo confocal microscope (IVCM) in contact with the eye. Here, we present a common-path Full-field/Spectral-domain OCT microscope (FF/SD OCT), which, for the first time, enables cell-detail imaging of the entire ocular surface (central and peripheral cornea, limbus, sclera, tear film) without contact and i…
▽ More
In today's clinics, a cellular-resolution view of the cornea can be achieved only with an in vivo confocal microscope (IVCM) in contact with the eye. Here, we present a common-path Full-field/Spectral-domain OCT microscope (FF/SD OCT), which, for the first time, enables cell-detail imaging of the entire ocular surface (central and peripheral cornea, limbus, sclera, tear film) without contact and in real time. The device, which has been successfully tested in human subjects, is now ready for direct implementation in clinical research. Real-time performance is achieved through rapid axial eye tracking and simultaneous defocusing correction. Images, extracted from real-time videos, contain cells and nerves, which can be quantified over a millimetric field-of-view, beyond the capability of IVCM and conventional OCT. In the limbus, Palisades of Vogt, vessels and blood flow can be resolved with high contrast without contrast agent injection. The fast imaging speed of 275 frames/s (0.6 billion pixels/s) allowed direct monitoring of blood flow dynamics, enabling creation of high-resolution velocity maps for the first time. Tear flow velocity and evaporation time could be measured without fluorescein administration.
△ Less
Submitted 22 January, 2020;
originally announced January 2020.
-
Curved-Full-Field OCT for high-resolution imaging of living human retina over a large field-of-view
Authors:
Pedro Mecê,
Kassandra Groux,
Jules Scholler,
Olivier Thouvenin,
Mathias Fink,
Kate Grieve,
Claude Boccara
Abstract:
Allying high-resolution with a large field-of-view (FOV) is of great importance in the fields of biology and medicine, but particularly challenging when imaging non-flat living samples such as the human retina. Indeed, high-resolution is normally achieved with adaptive optics (AO) and scanning methods, which considerably reduce the useful FOV and increase the system complexity. An alternative tech…
▽ More
Allying high-resolution with a large field-of-view (FOV) is of great importance in the fields of biology and medicine, but particularly challenging when imaging non-flat living samples such as the human retina. Indeed, high-resolution is normally achieved with adaptive optics (AO) and scanning methods, which considerably reduce the useful FOV and increase the system complexity. An alternative technique is time-domain Full-Field Optical Coherence Tomography (FF-OCT), which has already shown its potential for in-vivo high-resolution retinal imaging. Here, we introduce curved-field FF-OCT, capable of matching the coherence gate geometry to the sample curvature, thus achieving a larger FOV than previously possible. Using this instrument, we obtained high-resolution images of living human photoreceptors close to the foveal center without AO and with a 1 mm x 1 mm FOV in a single shot. This novel advance enables the extraction of photoreceptor-based biomarkers with ease and spatiotemporal monitoring of individual photoreceptors. We compare our findings with AO-assisted ophthalmoscopes, highlighting the potential of FF-OCT, as a relatively simple, compact and low-cost system, to become a routine clinical imaging technique.
△ Less
Submitted 19 January, 2020;
originally announced January 2020.
-
Technical Design Report for the PANDA Endcap Disc DIRC
Authors:
Panda Collaboration,
F. Davi,
W. Erni,
B. Krusche,
M. Steinacher,
N. Walford,
H. Liu,
Z. Liu,
B. Liu,
X. Shen,
C. Wang,
J. Zhao,
M. Albrecht,
T. Erlen,
F. Feldbauer,
M. Fink,
V. Freudenreich,
M. Fritsch,
F. H. Heinsius,
T. Held,
T. Holtmann,
I. Keshk,
H. Koch,
B. Kopf,
M. Kuhlmann
, et al. (441 additional authors not shown)
Abstract:
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c.…
▽ More
PANDA (anti-Proton ANnihiliation at DArmstadt) is planned to be one of the four main experiments at the future international accelerator complex FAIR (Facility for Antiproton and Ion Research) in Darmstadt, Germany. It is going to address fundamental questions of hadron physics and quantum chromodynamics using cooled antiproton beams with a high intensity and and momenta between 1.5 and 15 GeV/c. PANDA is designed to reach a maximum luminosity of 2x10^32 cm^2 s. Most of the physics programs require an excellent particle identification (PID). The PID of hadronic states at the forward endcap of the target spectrometer will be done by a fast and compact Cherenkov detector that uses the detection of internally reflected Cherenkov light (DIRC) principle. It is designed to cover the polar angle range from 5° to 22° and to provide a separation power for the separation of charged pions and kaons up to 3 standard deviations (s.d.) for particle momenta up to 4 GeV/c in order to cover the important particle phase space. This document describes the technical design and the expected performance of the novel PANDA Disc DIRC detector that has not been used in any other high energy physics experiment (HEP) before. The performance has been studied with Monte-Carlo simulations and various beam tests at DESY and CERN. The final design meets all PANDA requirements and guarantees suffcient safety margins.
△ Less
Submitted 29 December, 2019;
originally announced December 2019.
-
Distortion matrix approach for ultrasound imaging of random scattering media
Authors:
William Lambert,
Laura A. Cobus,
Thomas Frappart,
Mathias Fink,
Alexandre Aubry
Abstract:
Focusing waves inside inhomogeneous media is a fundamental problem for imaging. Spatial variations of wave velocity can strongly distort propagating wavefronts and degrade image quality. Adaptive focusing can compensate for such aberration, but is only effective over a restricted field of view. Here, we introduce a full-field approach to wave imaging based on the concept of the distortion matrix.…
▽ More
Focusing waves inside inhomogeneous media is a fundamental problem for imaging. Spatial variations of wave velocity can strongly distort propagating wavefronts and degrade image quality. Adaptive focusing can compensate for such aberration, but is only effective over a restricted field of view. Here, we introduce a full-field approach to wave imaging based on the concept of the distortion matrix. This operator essentially connects any focal point inside the medium with the distortion that a wavefront, emitted from that point, experiences due to heterogeneities. A time-reversal analysis of the distortion matrix enables the estimation of the transmission matrix that links each sensor and image voxel. Phase aberrations can then be unscrambled for any point, providing a full-field image of the medium with diffraction-limited resolution. Importantly, this process is particularly efficient in random scattering media, where traditional approaches such as adaptive focusing fail. Here, we first present an experimental proof-of-concept on a tissue mimicking phantom, and then apply the method to in vivo imaging of human soft tissues. While introduced here in the context of acoustics, this approach can also be extended to optical microscopy, radar or seismic imaging.
△ Less
Submitted 12 June, 2020; v1 submitted 11 December, 2019;
originally announced December 2019.
-
Dynamic full-field optical coherence tomography: 3D live-imaging of retinal organoids
Authors:
Jules Scholler,
Kassandra Groux,
Olivier Goureau,
José-Alain Sahel,
Mathias Fink,
Sacha Reichman,
Claude Boccara,
Kate Grieve
Abstract:
Optical coherence tomography offers astounding opportunities to image the complex structure of living tissue, but lacks functional information. We present dynamic full-field optical coherence tomography to image living human induced pluripotent stem cell-derived retinal organoids non-invasively. Colored images with an endogenous contrast linked to organelle motility are generated, with sub-microme…
▽ More
Optical coherence tomography offers astounding opportunities to image the complex structure of living tissue, but lacks functional information. We present dynamic full-field optical coherence tomography to image living human induced pluripotent stem cell-derived retinal organoids non-invasively. Colored images with an endogenous contrast linked to organelle motility are generated, with sub-micrometer spatial resolution and millisecond temporal resolution, opening an avenue to identify specific cell types in living tissue via their function.
△ Less
Submitted 5 December, 2019;
originally announced December 2019.
-
The mathematical structure of innovation
Authors:
Thomas M. A. Fink,
Ali Teimouri
Abstract:
Despite our familiarity with specific technologies, the origin of new technologies remains mysterious. Are new technologies made from scratch, or are they built up recursively from new combinations of existing technologies? To answer this, we introduce a simple model of recursive innovation in which technologies are made up of components and combinations of components can be turned into new compon…
▽ More
Despite our familiarity with specific technologies, the origin of new technologies remains mysterious. Are new technologies made from scratch, or are they built up recursively from new combinations of existing technologies? To answer this, we introduce a simple model of recursive innovation in which technologies are made up of components and combinations of components can be turned into new components---a process we call technological recursion. We derive a formula for the extent to which technological recursion increases or decreases the likelihood of making new technologies. We test our predictions on historical data from three domains and find that technologies are not built up from scratch, but are the result of new combinations of existing technologies. This suggests a dynamical process by which known technologies were made and a strategy for accelerating the discovery of new ones.
△ Less
Submitted 6 December, 2019;
originally announced December 2019.
-
Reversible Hardware for Acoustic Communications
Authors:
Harun Siljak,
Julien de Rosny,
Mathias Fink
Abstract:
Reversible computation has been recognised as a potential solution to the technological bottleneck in the future of computing machinery. Rolf Landauer determined the lower limit for power dissipation in computation and noted that dissipation happens when information is lost, i.e., when a bit is erased. This meant that reversible computation, conserving information conserves energy as well, and as…
▽ More
Reversible computation has been recognised as a potential solution to the technological bottleneck in the future of computing machinery. Rolf Landauer determined the lower limit for power dissipation in computation and noted that dissipation happens when information is lost, i.e., when a bit is erased. This meant that reversible computation, conserving information conserves energy as well, and as such can operate on arbitrarily small power. There were only a few applications and use cases of reversible computing hardware. Here we present a novel reversible computation architecture for time reversal of waves, with an application to sound wave communications. This energy efficient design is also a natural one, and it allows the use of the same hardware for transmission and reception at the time reversal mirror.
△ Less
Submitted 14 November, 2019;
originally announced November 2019.
-
Reflection matrix approach for quantitative imaging of scattering media
Authors:
William Lambert,
Laura A. Cobus,
Mathieu Couade,
Mathias Fink,
Alexandre Aubry
Abstract:
We present a physically intuitive matrix approach for wave imaging and characterization in scattering media. The experimental proof-of-concept is performed with ultrasonic waves, but this approach can be applied to any field of wave physics for which multi-element technology is available. The concept is that focused beamforming enables the synthesis, in transmit and receive, of an array of virtual…
▽ More
We present a physically intuitive matrix approach for wave imaging and characterization in scattering media. The experimental proof-of-concept is performed with ultrasonic waves, but this approach can be applied to any field of wave physics for which multi-element technology is available. The concept is that focused beamforming enables the synthesis, in transmit and receive, of an array of virtual transducers which map the entire medium to be imaged. The inter-element responses of this virtual array form a focused reflection matrix from which spatial maps of various characteristics of the propagating wave can be retrieved. Here we demonstrate: (i) a local focusing criterion that enables the image quality and the wave velocity to be evaluated everywhere inside the medium, including in random speckle, and (ii) an highly resolved spatial map** of the prevalence of multiple scattering, which constitutes a new and unique contrast for ultrasonic imaging. The approach is demonstrated for a controllable phantom system, and for in vivo imaging of the human abdomen. More generally, this matrix approach opens an original and powerful route for quantitative imaging in wave physics.
△ Less
Submitted 4 June, 2020; v1 submitted 8 November, 2019;
originally announced November 2019.
-
Distortion matrix concept for deep optical imaging in scattering media
Authors:
Amaury Badon,
Victor Barolle,
Kristina Irsch,
A. Claude Boccara,
Mathias Fink,
Alexandre Aubry
Abstract:
In optical imaging, light propagation is affected by the inhomogeneities of the medium. Sample-induced aberrations and multiple scattering can strongly degrade the image resolution and contrast. Based on a dynamic correction of the incident and/or reflected wave-fronts, adaptive optics has been employed to compensate for those aberrations. However, it only applies to spatially-invariant aberration…
▽ More
In optical imaging, light propagation is affected by the inhomogeneities of the medium. Sample-induced aberrations and multiple scattering can strongly degrade the image resolution and contrast. Based on a dynamic correction of the incident and/or reflected wave-fronts, adaptive optics has been employed to compensate for those aberrations. However, it only applies to spatially-invariant aberrations or to thin aberrating layers. Here, we propose a global and non-invasive approach based on the distortion matrix concept. This matrix basically connects any focusing point of the image with the distorted part of its wave-front in reflection. A singular value decomposition of the distortion matrix allows to correct for high-order aberrations and forward multiple scattering over multiple isoplanatic modes. Proof-of-concept experiments are performed through biological tissues including a turbid cornea. We demonstrate a Strehl ratio enhancement up to 2500 and recover a diffraction-limited resolution until a depth of ten scattering mean free paths.
△ Less
Submitted 31 July, 2020; v1 submitted 16 October, 2019;
originally announced October 2019.
-
Analysis of retinal and choroidal images measured by laser Doppler holography
Authors:
L. Puyo,
M. Paques,
M. Fink,
J-A Sahel,
M. Atlan
Abstract:
Laser Doppler holography (LDH) is a full-field imaging technique that was recently used in the human eye to reveal blood flow contrasts in the retinal and choroidal vasculature non-invasively, and with high temporal resolution. We here demonstrate that the ability of LDH to perform quantitative flow measurements with high temporal resolution enables arteriovenous differentiation in the retina and…
▽ More
Laser Doppler holography (LDH) is a full-field imaging technique that was recently used in the human eye to reveal blood flow contrasts in the retinal and choroidal vasculature non-invasively, and with high temporal resolution. We here demonstrate that the ability of LDH to perform quantitative flow measurements with high temporal resolution enables arteriovenous differentiation in the retina and choroid. In the retina, arteries and veins can be differentiated on the basis of their respective power Doppler waveforms. Choroidal arteries and veins can instead be discriminated by computing low and high frequency power Doppler images to reveal low and high blood flow images, respectively.
△ Less
Submitted 4 July, 2019;
originally announced July 2019.
-
Measuring Dirac Cones in a Sub-Wavelength Metamaterial
Authors:
Simon Yves,
Thomas Berthelot,
Mathias Fink,
Geoffroy Lerosey,
Fabrice Lemoult
Abstract:
The exciting discovery of bi-dimensional systems in condensed matter physics has triggered the search of their photonic analogues. In this letter, we describe a general scheme to reproduce some of the systems ruled by a tight-binding Hamiltonian in a locally resonant metamaterial: by specifically controlling the structure and the composition it is possible to engineer the band structure at will. W…
▽ More
The exciting discovery of bi-dimensional systems in condensed matter physics has triggered the search of their photonic analogues. In this letter, we describe a general scheme to reproduce some of the systems ruled by a tight-binding Hamiltonian in a locally resonant metamaterial: by specifically controlling the structure and the composition it is possible to engineer the band structure at will. We numerically and experimentally demonstrate this assertion in the microwave domain by reproducing the band structure of graphene, the most famous example of those 2D-systems, and by accurately extracting the Dirac cones. This is a direct evidence that opting for a crystalline description of those sub-wavelength scaled systems, as opposed to the usual description in terms of effective parameters, makes them a really convenient tabletop platform to investigate the tantalizing challenges that solid-state physics offer.
△ Less
Submitted 14 December, 2018;
originally announced December 2018.
-
Observation of the Talbot effect with water waves
Authors:
Alexandra Bakman,
Shmuel Fishman,
Mathias Fink,
Emmanuel Fort,
Sander Wildeman
Abstract:
When light is incident upon a diffraction grating, images of the grating appear at periodic intervals behind the grating. This phenomenon and the associated self-imaging distance were named after Talbot who first observed them in the nineteenth century. A century later, this effect held new surprises with the discovery of sub-images at regular fractional distances of the Talbot length. In this pap…
▽ More
When light is incident upon a diffraction grating, images of the grating appear at periodic intervals behind the grating. This phenomenon and the associated self-imaging distance were named after Talbot who first observed them in the nineteenth century. A century later, this effect held new surprises with the discovery of sub-images at regular fractional distances of the Talbot length. In this paper, we show that water waves enable one to observe the Talbot effect in a classroom experiment. Quantitative measurements, of for example the Talbot distances, can be performed with an easy to use digital Schlieren method.
△ Less
Submitted 16 November, 2018;
originally announced November 2018.
-
Optimal Communication Channels in a Disordered World with Tamed Randomness
Authors:
Philipp del Hougne,
Mathias Fink,
Geoffroy Lerosey
Abstract:
Multi-channel wireless systems have become a standard solution to address our information society's ever-increasing demand for more information transfer. The ultimate bound on the capacity such systems can achieve is the limited channel diversity in a given propagation medium, and countless proposals to reduce channel cross-talk by engineering software or hardware details of the signals and antenn…
▽ More
Multi-channel wireless systems have become a standard solution to address our information society's ever-increasing demand for more information transfer. The ultimate bound on the capacity such systems can achieve is the limited channel diversity in a given propagation medium, and countless proposals to reduce channel cross-talk by engineering software or hardware details of the signals and antenna arrays have been proposed. Here we demonstrate the physical sha** of the propagation medium itself to achieve optimal channel diversity. Using a reconfigurable metasurface placed inside a random environment, we tune the disorder and impose perfect orthogonality of wireless channels. We present experiments in the microwave domain in which we impose equal weights of the channel matrix eigenvalues for up to 4x4 systems, and almost equal weights in larger systems. We further describe one example of wireless image transmission in an office room in which we augmented the 3x3 system's number of effectively independent channels from 2 to the optimum of 3.
△ Less
Submitted 26 September, 2018;
originally announced October 2018.
-
Left-handed Band in an Electromagnetic Metamaterial Inducedby Sub-wavelength Multiple Scattering
Authors:
Simon Yves,
Thomas Berthelot,
Mathias Fink,
Geoffroy Lerosey,
Fabrice Lemoult
Abstract:
Due to the deep sub-wavelength unit cell in metamaterials, the quasi-static approximation is usually employed to describe the propagation. By making pairs of resonators, we highlight that multiple scattering also occurs at this scale and results in the existence of a dipolar resonance, which leads to a negative index of refraction when we consider several resonators. We experimentally verify the p…
▽ More
Due to the deep sub-wavelength unit cell in metamaterials, the quasi-static approximation is usually employed to describe the propagation. By making pairs of resonators, we highlight that multiple scattering also occurs at this scale and results in the existence of a dipolar resonance, which leads to a negative index of refraction when we consider several resonators. We experimentally verify the possibility of obtaining a negative index of refraction in periodic metamaterials in two different ways, and eventually demonstrates a superlensing effect in both cases.
△ Less
Submitted 26 September, 2018;
originally announced September 2018.
-
In vivo laser Doppler holography of the human retina
Authors:
L. Puyo,
M. Paques,
M. Fink,
J. -A. Sahel,
M. Atlan
Abstract:
The eye offers a unique opportunity for non-invasive exploration of cardiovascular diseases. Optical angiography in the retina requires sensitive measurements, which hinders conventional full-field laser Doppler imaging schemes. To overcome this limitation, we used digital holography to perform laser Doppler perfusion imaging of the human retina in vivo with near-infrared light. Wideband measureme…
▽ More
The eye offers a unique opportunity for non-invasive exploration of cardiovascular diseases. Optical angiography in the retina requires sensitive measurements, which hinders conventional full-field laser Doppler imaging schemes. To overcome this limitation, we used digital holography to perform laser Doppler perfusion imaging of the human retina in vivo with near-infrared light. Wideband measurements of the beat frequency spectrum of optical interferograms recorded with a 39 kHz CMOS camera are analyzed by short-time Fourier transformation. Power Doppler images and movies drawn from the zeroth moment of the power spectrum density reveal blood flows in retinal and choroidal vessels over 512 $\times$ 512 pixels covering 2.4 $\times$ 2.4 mm$^2$ on the retina with a 13 ms temporal resolution.
△ Less
Submitted 13 September, 2018; v1 submitted 25 April, 2018;
originally announced April 2018.