-
A Radial Time Projection Chamber for $α$ detection in CLAS at JLab
Authors:
R. Dupré,
S. Stepanyan,
M. Hattawy,
N. Baltzell,
K. Hafidi,
M. Battaglieri,
S. Bueltmann,
A. Celentano,
R. De Vita,
A. El Alaoui,
L. El Fassi,
H. Fenker,
K. Kosheleva,
S. Kuhn,
P. Musico,
S. Minutoli,
M. Oliver,
Y. Perrin,
B. Torayev,
E. Voutier
Abstract:
A new Radial Time Projection Chamber (RTPC) was developed at the Jefferson Laboratory to track low-energy nuclear recoils for the purpose of measuring exclusive nuclear reactions, such as coherent Deeply Virtual Compton Scattering and coherent meson production off $^4$He. In such processes, the $^4$He nucleus remains intact in the final state, however the CEBAF Large Acceptance Spectrometer (CLAS)…
▽ More
A new Radial Time Projection Chamber (RTPC) was developed at the Jefferson Laboratory to track low-energy nuclear recoils for the purpose of measuring exclusive nuclear reactions, such as coherent Deeply Virtual Compton Scattering and coherent meson production off $^4$He. In such processes, the $^4$He nucleus remains intact in the final state, however the CEBAF Large Acceptance Spectrometer (CLAS) cannot track the low energy $α$ particles. In 2009, we carried out measurements using the CLAS spectrometer supplemented by the RTPC positioned directly around a gaseous $^4$He target, allowing a detection threshold as low as 12$\sim$MeV for $^4$He. This article discusses the design, principle of operation, calibration methods and the performances of this RTPC.
△ Less
Submitted 30 January, 2018; v1 submitted 30 June, 2017;
originally announced June 2017.
-
DarkLight: A Search for Dark Forces at the Jefferson Laboratory Free-Electron Laser Facility
Authors:
J. Balewski,
J. Bernauer,
W. Bertozzi,
J. Bessuille,
B. Buck,
R. Cowan,
K. Dow,
C. Epstein,
P. Fisher,
S. Gilad,
E. Ihloff,
Y. Kahn,
A. Kelleher,
J. Kelsey,
R. Milner,
C. Moran,
L. Ou,
R. Russell,
B. Schmookler,
J. Thaler,
C. Tschalär,
C. Vidal,
A. Winnebeck,
S. Benson,
C. Gould
, et al. (42 additional authors not shown)
Abstract:
We give a short overview of the DarkLight detector concept which is designed to search for a heavy photon A' with a mass in the range 10 MeV/c^2 < m(A') < 90 MeV/c^2 and which decays to lepton pairs. We describe the intended operating environment, the Jefferson Laboratory free electon laser, and a way to extend DarkLight's reach using A' --> invisible decays.
We give a short overview of the DarkLight detector concept which is designed to search for a heavy photon A' with a mass in the range 10 MeV/c^2 < m(A') < 90 MeV/c^2 and which decays to lepton pairs. We describe the intended operating environment, the Jefferson Laboratory free electon laser, and a way to extend DarkLight's reach using A' --> invisible decays.
△ Less
Submitted 19 July, 2013; v1 submitted 16 July, 2013;
originally announced July 2013.
-
The lead-glass electromagnetic calorimeters for the magnetic spectrometers in Hall C at Jefferson Lab
Authors:
H. Mkrtchyan,
R. Carlini,
V. Tadevosyan,
J. Arrington,
A. Asaturyan,
M. E. Christy,
D. Dutta,
R. Ent,
H. C. Fenker,
D. Gaskell,
T. Horn,
M. K. Jones,
C. E. Keppel,
D. J. Mack,
S. P. Malace,
A. Mkrtchyan,
M. I. Niculescu,
J. Seely,
V. Tvaskis,
S. A. Wood,
S. Zhamkochyan
Abstract:
The electromagnetic calorimeters of the various magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers design considerations, relevant construction information, and comparisons of simulated and experimental results are included. The energy resolution of the HMS and SOS calorimeters is better than $σ/E \sim 6%/\sqrt E $, and pion/electron ($π/e$)…
▽ More
The electromagnetic calorimeters of the various magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers design considerations, relevant construction information, and comparisons of simulated and experimental results are included. The energy resolution of the HMS and SOS calorimeters is better than $σ/E \sim 6%/\sqrt E $, and pion/electron ($π/e$) separation of about 100:1 has been achieved in energy range 1 -- 5 GeV. Good agreement has been observed between the experimental and simulated energy resolutions, but simulations systematically exceed experimentally determined $π^-$ suppression factors by close to a factor of two. For the SHMS spectrometer presently under construction details on the design and accompanying GEANT4 simulation efforts are given. The anticipated performance of the new calorimeter is predicted over the full momentum range of the SHMS. Good electron/hadron separation is anticipated by combining the energy deposited in an initial (preshower) calorimeter layer with the total energy deposited in the calorimeter.
△ Less
Submitted 28 April, 2012;
originally announced April 2012.
-
The Qweak Experiment: A Search for New Physics at the TeV Scale via a Measurement of the Proton's Weak Charge
Authors:
R. D. Carlini,
J. M. Finn,
S. Kowalski,
S. A. Page,
D. S. Armstrong,
A. Asaturyan,
T. Averett,
J. Benesch,
J. Birchall,
P. Bosted,
A. Bruell,
C. L. Capuano,
G. Cates,
C. Carrigee,
S. Chattopadhyay,
S. Covrig,
C. A. Davis,
K. Dow,
J. Dunne,
D. Dutta,
R. Ent,
J. Erler,
W. Falk,
H. Fenker,
T. A. Forest
, et al. (61 additional authors not shown)
Abstract:
We propose a new precision measurement of parity-violating electron scattering on the proton at very low Q^2 and forward angles to challenge predictions of the Standard Model and search for new physics. A unique opportunity exists to carry out the first precision measurement of the proton's weak charge, $Q_W =1 - 4\sin^2θ_W$. A 2200 hour measurement of the parity violating asymmetry in elastic ep…
▽ More
We propose a new precision measurement of parity-violating electron scattering on the proton at very low Q^2 and forward angles to challenge predictions of the Standard Model and search for new physics. A unique opportunity exists to carry out the first precision measurement of the proton's weak charge, $Q_W =1 - 4\sin^2θ_W$. A 2200 hour measurement of the parity violating asymmetry in elastic ep scattering at Q^2=0.03 (GeV/c)^2 employing 180 $μ$A of 85% polarized beam on a 35 cm liquid Hydrogen target will determine the proton's weak charge with approximately 4% combined statistical and systematic errors. The Standard Model makes a firm prediction of $Q_W$, based on the running of the weak mixing angle from the Z0 pole down to low energies, corresponding to a 10 sigma effect in this experiment.
△ Less
Submitted 7 February, 2012; v1 submitted 6 February, 2012;
originally announced February 2012.
-
The G0 Experiment: Apparatus for Parity-Violating Electron Scattering Measurements at Forward and Backward Angles
Authors:
G0 Collaboration,
D. Androic,
D. S. Armstrong,
J. Arvieux,
R. Asaturyan,
T. D. Averett,
S. L. Bailey,
G. Batigne,
D. H. Beck,
E. J. Beise,
J. Benesch,
F. Benmokhtar,
L. Bimbot,
J. Birchall,
A. Biselli,
P. Bosted,
H. Breuer,
P. Brindza,
C. L. Capuano,
R. D. Carlini,
R. Carr,
N. Chant,
Y. -C. Chao,
R. Clark,
A. Coppens
, et al. (105 additional authors not shown)
Abstract:
In the G0 experiment, performed at Jefferson Lab, the parity-violating elastic scattering of electrons from protons and quasi-elastic scattering from deuterons is measured in order to determine the neutral weak currents of the nucleon. Asymmetries as small as 1 part per million in the scattering of a polarized electron beam are determined using a dedicated apparatus. It consists of specialized bea…
▽ More
In the G0 experiment, performed at Jefferson Lab, the parity-violating elastic scattering of electrons from protons and quasi-elastic scattering from deuterons is measured in order to determine the neutral weak currents of the nucleon. Asymmetries as small as 1 part per million in the scattering of a polarized electron beam are determined using a dedicated apparatus. It consists of specialized beam-monitoring and control systems, a cryogenic hydrogen (or deuterium) target, and a superconducting, toroidal magnetic spectrometer equipped with plastic scintillation and aerogel Cerenkov detectors, as well as fast readout electronics for the measurement of individual events. The overall design and performance of this experimental system is discussed.
△ Less
Submitted 3 March, 2011;
originally announced March 2011.
-
The aerogel threshold Cherenkov detector for the High Momentum Spectrometer in Hall C at Jefferson Lab
Authors:
R. Asaturyan,
R. Ent,
H. Fenker,
D. Gaskell,
G. M. Huber,
M. Jones,
D. Mack,
H. Mkrtchyan,
B. Metzger,
N. Novikoff,
V. Tadevosyan,
W. Vulcan,
S. Wood
Abstract:
We describe a new aerogel threshold Cherenkov detector installed in the HMS spectrometer in Hall C at Jefferson Lab. The Hall C experimental program in 2003 required an improved particle identification system for better identification of pi/K/P, which was achieved by installing an additional threshold Cherenkov counter. Two types of aerogel with n=1.03 and n=1.015 allow one to reach 10^{-3} prot…
▽ More
We describe a new aerogel threshold Cherenkov detector installed in the HMS spectrometer in Hall C at Jefferson Lab. The Hall C experimental program in 2003 required an improved particle identification system for better identification of pi/K/P, which was achieved by installing an additional threshold Cherenkov counter. Two types of aerogel with n=1.03 and n=1.015 allow one to reach 10^{-3} proton and 10^{-2} kaon rejection in the 1-5 GeV/c momentum range with pion detection efficiency better than 99% (97%). The detector response shows no significant position dependence due to a diffuse light collection technique. The diffusion box was equipped with 16 Photonis XP4572 PMT's. The mean number of photoelectrons in saturation was ~16 and ~8, respectively. Moderate particle identification is feasible near threshold.
△ Less
Submitted 16 November, 2004;
originally announced November 2004.