-
Prompt Engineering for Transformer-based Chemical Similarity Search Identifies Structurally Distinct Functional Analogues
Authors:
Clayton W. Kosonocky,
Aaron L. Feller,
Claus O. Wilke,
Andrew D. Ellington
Abstract:
Chemical similarity searches are widely used in-silico methods for identifying new drug-like molecules. These methods have historically relied on structure-based comparisons to compute molecular similarity. Here, we use a chemical language model to create a vector-based chemical search. We extend implementations by creating a prompt engineering strategy that utilizes two different chemical string…
▽ More
Chemical similarity searches are widely used in-silico methods for identifying new drug-like molecules. These methods have historically relied on structure-based comparisons to compute molecular similarity. Here, we use a chemical language model to create a vector-based chemical search. We extend implementations by creating a prompt engineering strategy that utilizes two different chemical string representation algorithms: one for the query and the other for the database. We explore this method by reviewing the search results from five drug-like query molecules (penicillin G, nirmatrelvir, zidovudine, lysergic acid diethylamide, and fentanyl) and three dye-like query molecules (acid blue 25, avobenzone, and 2-diphenylaminocarbazole). We find that this novel method identifies molecules that are functionally similar to the query, indicated by the associated patent literature, and that many of these molecules are structurally distinct from the query, making them unlikely to be found with traditional chemical similarity search methods. This method may aid in the discovery of novel structural classes of molecules that achieve target functionality.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Magnetic fields inferred by Solar Orbiter: A comparison between SO/PHI-HRT and SDO/HMI
Authors:
J. Sinjan,
D. Calchetti,
J. Hirzberger,
F. Kahil,
G. Valori,
S. K. Solanki,
K. Albert,
N. Albelo Jorge,
A. Alvarez-Herrero,
T. Appourchaux,
L. R. Bellot Rubio,
J. Blanco Rodríguez,
A. Feller,
A. Gandorfer,
D. Germerott,
L. Gizon,
J. M. Gómez Cama,
L. Guerrero,
P. Gutierrez-Marques,
M. Kolleck,
A. Korpi-Lagg,
H. Michalik,
A. Moreno Vacas,
D. Orozco Suárez,
I. Pérez-Grande
, et al. (9 additional authors not shown)
Abstract:
The High Resolution Telescope (HRT) of the Polarimetric and Helioseismic Imager on board the Solar Orbiter spacecraft (SO/PHI) and the Helioseismic and Magnetic Imager (HMI) on board the Solar Dynamics Observatory (SDO) both infer the photospheric magnetic field from polarised light images. SO/PHI is the first magnetograph to move out of the Sun--Earth line and will provide unprecedented access to…
▽ More
The High Resolution Telescope (HRT) of the Polarimetric and Helioseismic Imager on board the Solar Orbiter spacecraft (SO/PHI) and the Helioseismic and Magnetic Imager (HMI) on board the Solar Dynamics Observatory (SDO) both infer the photospheric magnetic field from polarised light images. SO/PHI is the first magnetograph to move out of the Sun--Earth line and will provide unprecedented access to the Sun's poles. This provides excellent opportunities for new research wherein the magnetic field maps from both instruments are used simultaneously. We aim to compare the magnetic field maps from these two instruments and discuss any possible differences between them. We used data from both instruments obtained during Solar Orbiter's inferior conjunction on 7 March 2022. The HRT data were additionally treated for geometric distortion and degraded to the same resolution as HMI. The HMI data were re-projected to correct for the $3^{\circ}$ separation between the two observatories. SO/PHI-HRT and HMI produce remarkably similar line-of-sight magnetograms, with a slope coefficient of $0.97$, an offset below $1$ G, and a Pearson correlation coefficient of $0.97$. However, SO/PHI-HRT infers weaker line-of-sight fields for the strongest fields. As for the vector magnetic field, SO/PHI-HRT was compared to both the $720$-second and $90$-second HMI vector magnetic field: SO/PHI-HRT has a closer alignment with the $90$-second HMI vector. In the weak signal regime ($< 600$ G), SO/PHI-HRT measures stronger and more horizontal fields than HMI, very likely due to the greater noise in the SO/PHI-HRT data. In the strong field regime ($\gtrsim 600$ G), HRT infers lower field strengths but with similar inclinations (a slope of $0.92$) and azimuths (a slope of $1.02$). The slope values are from the comparison with the HMI $90$-second vector.
△ Less
Submitted 29 March, 2023;
originally announced March 2023.
-
Smear correction of highly-variable, frame-transfer-CCD images with application to polarimetry
Authors:
Francisco A. Iglesias,
Alex Feller,
K. Nagaraju
Abstract:
Image smear, produced by the shutter-less operation of frame transfer CCD detectors, can be detrimental for many imaging applications. Existing algorithms used to numerically remove smear, do not contemplate cases where intensity levels change considerably between consecutive frame exposures. In this report we reformulate the smearing model to include specific variations of the sensor illumination…
▽ More
Image smear, produced by the shutter-less operation of frame transfer CCD detectors, can be detrimental for many imaging applications. Existing algorithms used to numerically remove smear, do not contemplate cases where intensity levels change considerably between consecutive frame exposures. In this report we reformulate the smearing model to include specific variations of the sensor illumination. The corresponding desmearing expression and its noise properties are also presented and demonstrated in the context of fast imaging polarimetry.
△ Less
Submitted 11 June, 2015;
originally announced June 2015.
-
Precision in ground based solar polarimetry: Simulating the role of adaptive optics
Authors:
K. Nagaraju,
Alex Feller
Abstract:
Accurate measurement of polarization in spectral lines is important for the reliable inference of magnetic fields on the Sun. For ground based observations, polarimetric precision is severely limited by the presence of Earth's atmosphere. Atmospheric turbulence (seeing) produces signal fluctuations which combined with the non-simultaneous nature of the measurement process cause intermixing of the…
▽ More
Accurate measurement of polarization in spectral lines is important for the reliable inference of magnetic fields on the Sun. For ground based observations, polarimetric precision is severely limited by the presence of Earth's atmosphere. Atmospheric turbulence (seeing) produces signal fluctuations which combined with the non-simultaneous nature of the measurement process cause intermixing of the Stokes parameters known as seeing induced polarization cross-talk. Previous analysis of this effect (Judge et al., 2004) suggests that cross-talk is reduced not only with increase in modulation frequency but also by compensating the seeing induced image aberrations by an Adaptive Optics (AO) system. However, in those studies the effect of higher order image aberrations than those corrected by the AO system was not taken into account. We present in this paper an analysis of seeing induced cross-talk in the presence of higher order image aberrations through numerical simulation. In this analysis we find that the amount of cross-talk among Stokes parameters is practically independent of the degree of image aberration corrected by an AO system. However, higher order AO corrections increase the signal-to-noise ratio by reducing the seeing caused image smearing.
△ Less
Submitted 2 November, 2012;
originally announced November 2012.