-
The CaloCube calorimeter for high-energy cosmic-ray measurements in space: performance of a large-scale prototype
Authors:
O. Adriani,
A. Agnesi,
S. Albergo,
M. Antonelli,
L. Auditore,
A. Basti,
E. Berti,
G. Bigongiari,
L. Bonechi,
M. Bongi,
V. Bonvicini,
S. Bottai,
P. Brogi,
G. Castellini,
P. W. Cattaneo,
C. Checchia,
R. D Alessandro,
S. Detti,
M. Fasoli,
N. Finetti,
A. Italiano,
P. Maestro,
P. S. Marrocchesi,
N. Mori,
G. Orzan
, et al. (23 additional authors not shown)
Abstract:
The direct observation of high-energy cosmic rays, up to the PeV energy region, will increasingly rely on highly performing calorimeters, and the physics performance will be primarily determined by their geometrical acceptance and energy resolution. Thus, it is extremely important to optimize their geometrical design, granularity and absorption depth, with respect to the totalmass of the apparatus…
▽ More
The direct observation of high-energy cosmic rays, up to the PeV energy region, will increasingly rely on highly performing calorimeters, and the physics performance will be primarily determined by their geometrical acceptance and energy resolution. Thus, it is extremely important to optimize their geometrical design, granularity and absorption depth, with respect to the totalmass of the apparatus, which is amongst the most important constraints for a space mission. CaloCube is an homogeneous calorimeter whose basic geometry is cubic and isotropic, obtained by filling the cubic volume with small cubic scintillating crystals. In this way it is possible to detect particles arriving from every direction in space, thus maximizing the acceptance. This design summarizes a three-year R&D activity, aiming to both optimize and study the full-scale performance of the calorimeter, in the perspective of a cosmic-ray space mission, and investigate a viable technical design by means of the construction of several sizable prototypes. A large scale prototype, made of a mesh of 5x5x18 CsI(Tl) crystals, has been constructed and tested on high-energy particle beams at CERN SPS accelerator. In this paper we describe the CaloCube design and present the results relative to the response of the large scale prototype to electrons.
△ Less
Submitted 4 October, 2021;
originally announced October 2021.
-
A CUPID Li$_{2}$$^{100}$MoO$_4$ scintillating bolometer tested in the CROSS underground facility
Authors:
The CUPID Interest Group,
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
I. C. Bandac,
A. S. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergé,
Ch. Bourgeois,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. M. Calvo-Mozota,
J. Camilleri
, et al. (156 additional authors not shown)
Abstract:
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 an…
▽ More
A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2β$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $γ$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$σ$) between $γ$($β$) and $α$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $μ$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2β$ decay in CROSS and CUPID projects.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
Characterization of cubic Li$_{2}$$^{100}$MoO$_4$ crystals for the CUPID experiment
Authors:
A. Armatol,
E. Armengaud,
W. Armstrong,
C. Augier,
F. T. Avignone III,
O. Azzolini,
A. Barabash,
G. Bari,
A. Barresi,
D. Baudin,
F. Bellini,
G. Benato,
M. Beretta,
L. Bergè,
M. Biassoni,
J. Billard,
V. Boldrini,
A. Branca,
C. Brofferio,
C. Bucci,
J. Camilleri,
S. Capelli,
L. Cappelli,
L. Cardani,
P. Carniti
, et al. (147 additional authors not shown)
Abstract:
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta…
▽ More
The CUPID Collaboration is designing a tonne-scale, background-free detector to search for double beta decay with sufficient sensitivity to fully explore the parameter space corresponding to the inverted neutrino mass hierarchy scenario. One of the CUPID demonstrators, CUPID-Mo, has proved the potential of enriched Li$_{2}$$^{100}$MoO$_4$ crystals as suitable detectors for neutrinoless double beta decay search. In this work, we characterised cubic crystals that, compared to the cylindrical crystals used by CUPID-Mo, are more appealing for the construction of tightly packed arrays. We measured an average energy resolution of (6.7$\pm$0.6) keV FWHM in the region of interest, approaching the CUPID target of 5 keV FWHM. We assessed the identification of $α$ particles with and without a reflecting foil that enhances the scintillation light collection efficiency, proving that the baseline design of CUPID already ensures a complete suppression of this $α$-induced background contribution. We also used the collected data to validate a Monte Carlo simulation modelling the light collection efficiency, which will enable further optimisations of the detector.
△ Less
Submitted 27 November, 2020;
originally announced November 2020.
-
The DUNE Far Detector Interim Design Report, Volume 3: Dual-Phase Module
Authors:
DUNE Collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
D. Adams,
P. Adamson,
M. Adinolfi,
Z. Ahmad,
C. H. Albright,
L. Aliaga Soplin,
T. Alion,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. P. Andrews,
R. A. Andrews,
A. Ankowski,
J. Anthony,
M. Antonello,
M. Antonova
, et al. (1076 additional authors not shown)
Abstract:
The DUNE IDR describes the proposed physics program and technical designs of the DUNE far detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable…
▽ More
The DUNE IDR describes the proposed physics program and technical designs of the DUNE far detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable the DUNE experiment to make the ground-breaking discoveries that will help to answer fundamental physics questions. Volume 3 describes the dual-phase module's subsystems, the technical coordination required for its design, construction, installation, and integration, and its organizational structure.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.
-
The DUNE Far Detector Interim Design Report Volume 1: Physics, Technology and Strategies
Authors:
DUNE Collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
D. Adams,
P. Adamson,
M. Adinolfi,
Z. Ahmad,
C. H. Albright,
L. Aliaga Soplin,
T. Alion,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. P. Andrews,
R. A. Andrews,
A. Ankowski,
J. Anthony,
M. Antonello,
M. Antonova
, et al. (1076 additional authors not shown)
Abstract:
The DUNE IDR describes the proposed physics program and technical designs of the DUNE Far Detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable…
▽ More
The DUNE IDR describes the proposed physics program and technical designs of the DUNE Far Detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable the DUNE experiment to make the ground-breaking discoveries that will help to answer fundamental physics questions. Volume 1 contains an executive summary that describes the general aims of this document. The remainder of this first volume provides a more detailed description of the DUNE physics program that drives the choice of detector technologies. It also includes concise outlines of two overarching systems that have not yet evolved to consortium structures: computing and calibration. Volumes 2 and 3 of this IDR describe, for the single-phase and dual-phase technologies, respectively, each detector module's subsystems, the technical coordination required for its design, construction, installation, and integration, and its organizational structure.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.
-
The DUNE Far Detector Interim Design Report, Volume 2: Single-Phase Module
Authors:
DUNE Collaboration,
B. Abi,
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
D. Adams,
P. Adamson,
M. Adinolfi,
Z. Ahmad,
C. H. Albright,
L. Aliaga Soplin,
T. Alion,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. P. Andrews,
R. A. Andrews,
A. Ankowski,
J. Anthony,
M. Antonello,
M. Antonova
, et al. (1076 additional authors not shown)
Abstract:
The DUNE IDR describes the proposed physics program and technical designs of the DUNE far detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable…
▽ More
The DUNE IDR describes the proposed physics program and technical designs of the DUNE far detector modules in preparation for the full TDR to be published in 2019. It is intended as an intermediate milestone on the path to a full TDR, justifying the technical choices that flow down from the high-level physics goals through requirements at all levels of the Project. These design choices will enable the DUNE experiment to make the ground-breaking discoveries that will help to answer fundamental physics questions. Volume 2 describes the single-phase module's subsystems, the technical coordination required for its design, construction, installation, and integration, and its organizational structure.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.
-
The Single-Phase ProtoDUNE Technical Design Report
Authors:
B. Abi,
R. Acciarri,
M. A. Acero,
M. Adamowski,
C. Adams,
D. L. Adams,
P. Adamson,
M. Adinolfi,
Z. Ahmad,
C. H. Albright,
T. Alion,
J. Anderson,
K. Anderson,
C. Andreopoulos,
M. P. Andrews,
R. A. Andrews,
J. dos Anjos,
A. Ankowski,
J. Anthony,
M. Antonello,
A. Aranda Fernandez,
A. Ariga,
T. Ariga,
E. Arrieta Diaz,
J. Asaadi
, et al. (806 additional authors not shown)
Abstract:
ProtoDUNE-SP is the single-phase DUNE Far Detector prototype that is under construction and will be operated at the CERN Neutrino Platform (NP) starting in 2018. ProtoDUNE-SP, a crucial part of the DUNE effort towards the construction of the first DUNE 10-kt fiducial mass far detector module (17 kt total LAr mass), is a significant experiment in its own right. With a total liquid argon (LAr) mass…
▽ More
ProtoDUNE-SP is the single-phase DUNE Far Detector prototype that is under construction and will be operated at the CERN Neutrino Platform (NP) starting in 2018. ProtoDUNE-SP, a crucial part of the DUNE effort towards the construction of the first DUNE 10-kt fiducial mass far detector module (17 kt total LAr mass), is a significant experiment in its own right. With a total liquid argon (LAr) mass of 0.77 kt, it represents the largest monolithic single-phase LArTPC detector to be built to date. It's technical design is given in this report.
△ Less
Submitted 27 July, 2017; v1 submitted 21 June, 2017;
originally announced June 2017.
-
CaloCube: a novel calorimeter for high-energy cosmic rays in space
Authors:
P. W. Cattaneo,
O. Adriani,
S. Albergo,
L. Auditore,
A. Basti,
E. Berti,
G. Bigongiari,
L. Bonechi,
S. Bonechi,
M. Bongi,
V. Bonvicini,
S. Bottai,
P. Brogi,
G. Carotenuto,
G. Castellini,
R. ďAlessandro,
S. Detti,
M. Fasoli,
N. Finetti,
A. Italiano,
P. Lenzi,
P. Maestro,
P. S. Marrocchesi,
N. Mori,
M. Olmi
, et al. (21 additional authors not shown)
Abstract:
In order to extend the direct observation of high-energy cosmic rays up to the PeV region, highly performing calorimeters with large geometrical acceptance and high energy resolution are required. Within the constraint of the total mass of the apparatus, crucial for a space mission, the calorimeters must be optimized with respect to their geometrical acceptance, granularity and absorption depth. C…
▽ More
In order to extend the direct observation of high-energy cosmic rays up to the PeV region, highly performing calorimeters with large geometrical acceptance and high energy resolution are required. Within the constraint of the total mass of the apparatus, crucial for a space mission, the calorimeters must be optimized with respect to their geometrical acceptance, granularity and absorption depth. CaloCube is a homogeneous calorimeter with cubic geometry, to maximise the acceptance being sensitive to particles from every direction in space; granularity is obtained by relying on small cubic scintillating crystals as active elements. Different scintillating materials have been studied. The crystal sizes and spacing among them have been optimized with respect to the energy resolution. A prototype, based on CsI(Tl) cubic crystals, has been constructed and tested with particle beams. Some results of tests with different beams at CERN are presented.
△ Less
Submitted 23 May, 2017; v1 submitted 19 May, 2017;
originally announced May 2017.