Skip to main content

Showing 1–39 of 39 results for author: Fanourakis, G

Searching in archive physics. Search in all archives.
.
  1. arXiv:2406.08712  [pdf, other

    physics.ins-det hep-ex

    A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors

    Authors: X. Wang, R. Aleksan, Y. Angelis, J. Bortfeldt, F. Brunbauer, M. Brunoldi, E. Chatzianagnostou, J. Datta, K. Degmelt, G. Fanourakis, D. Fiorina, K. J. Floethner, M. Gallinaro, F. Garcia, I. Giomataris, K. Gnanvo, F. J. Iguaz, D. Janssens, A. Kallitsopoulou, M. Kovacic, B. Kross, P. Legou, M. Lisowska, J. Liu, I. Maniatis , et al. (26 additional authors not shown)

    Abstract: The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bomb… ▽ More

    Submitted 25 June, 2024; v1 submitted 12 June, 2024; originally announced June 2024.

  2. arXiv:2406.05657  [pdf, other

    physics.ins-det

    Single channel PICOSEC Micromegas detector with improved time resolution

    Authors: A. Utrobicic, R. Aleksan, Y. Angelis, J. Bortfeldt, F. Brunbauer, M. Brunoldi, E. Chatzianagnostou, J. Datta, K. Dehmelt, G. Fanourakis, D. Fiorina, K. J. Floethner, M. Gallinaro, F. Garcia, I. Giomataris, K. Gnanvo, F. J. Iguaz, D. Janssens, A. Kallitsopoulou, M. Kovacic, B. Kross, P. Legou, M. Lisowska, J. Liu, M. Lupberger , et al. (25 additional authors not shown)

    Abstract: This paper presents design guidelines and experimental verification of a single-channel PICOSEC Micromegas (MM) detector with an improved time resolution. The design encompasses the detector board, vessel, auxiliary mechanical parts, and electrical connectivity for high voltage (HV) and signals, focusing on improving stability, reducing noise, and ensuring signal integrity to optimize timing perfo… ▽ More

    Submitted 9 June, 2024; originally announced June 2024.

  3. A large area 100 channel Picosec Micromegas detector with sub 20 ps time resolution

    Authors: Antonija Utrobicic, Yannis Angelis, Stephan Aune, Jonathan Bortfeldt, Florian Brunbauer, Evridiki Chatzianagnostou, Klaus Dehmelt, Daniel Desforge, George Fanourakis, Karl Jonathan Floethner, Michele Gallinaro, Francisco Garcia, Prakhar Garg, Ioannis Giomataris, Kondo Gnanvo, Thomas Gustavsson, Francisco Jose Iguaz, Djunes Janssens, Alexandra Kallitsopoulou, Marinko Kovacic, Philippe Legou, Marta Lisowska, Jianbei Liu, Michael Lupberger, Simona Malace , et al. (20 additional authors not shown)

    Abstract: The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof of concept single-channel small area prototype was able to achieve time resolution below 25 ps. One of the crucial aspects in the development of the precise timing gaseous detectors applicable in high-energy physics exp… ▽ More

    Submitted 31 March, 2023; originally announced April 2023.

  4. Towards robust PICOSEC Micromegas precise timing detectors

    Authors: Marta Lisowska, Yannis Angelis, Stephan Aune, Jonathan Bortfeldt, Florian Brunbauer, Evridiki Chatzianagnostou, Klaus Dehmelt, Daniel Desforge, George Fanourakis, Karl Jonathan Floethner, Michele Gallinaro, Francisco Garcia, Prakhar Garg, Ioannis Giomataris, Kondo Gnanvo, Thomas Gustavsson, Francisco Jose Iguaz, Djunes Janssens, Alexandra Kallitsopoulou, Marinko Kovacic, Philippe Legou, Jianbei Liu, Michael Lupberger, Simona Malace, Ioannis Maniatis , et al. (21 additional authors not shown)

    Abstract: The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel non-resistive PICOSEC MM prototype with 10x10 cm^2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below 18 ps. The objective of this work is to improve the PICOSEC MM detec… ▽ More

    Submitted 31 March, 2023; originally announced March 2023.

  5. arXiv:2303.17356  [pdf, other

    hep-ex hep-ph physics.ins-det

    The ESSnuSB design study: overview and future prospects

    Authors: ESSnuSB Collaboration, A. Alekou, E. Baussan, A. K. Bhattacharyya, N. Blaskovic Kraljevic, M. Blennow, M. Bogomilov, B. Bolling, E. Bouquerel, F. Bramati, A. Branca, O. Buchan, A. Burgman, C. J. Carlile, J. Cederkall, S. Choubey, P. Christiansen, M. Collins, E. Cristaldo Morales, L. D'Alessi, H. Danared, D. Dancila, J. P. A. M. de André, J. P. Delahaye, M. Dracos , et al. (61 additional authors not shown)

    Abstract: ESSnuSB is a design study for an experiment to measure the CP violation in the leptonic sector at the second neutrino oscillation maximum using a neutrino beam driven by the uniquely powerful ESS linear accelerator. The reduced impact of systematic errors on sensitivity at the second maximum allows for a very precise measurement of the CP violating parameter. This review describes the fundamental… ▽ More

    Submitted 8 August, 2023; v1 submitted 30 March, 2023; originally announced March 2023.

    Comments: 19 pages, 12 figures; Final version after review by the Universe journal

  6. Precise timing and recent advancements with segmented anode PICOSEC Micromegas prototypes

    Authors: I. Manthos, S. Aune, J. Bortfeldt, F. Brunbauer, C. David, D. Desforge, G. Fanourakis, M. Gallinaro, F. García, I. Giomataris, T. Gustavsson, F. J. Iguaz, A. Kallitsopoulou, M. Kebbiri, K. Kordas, C. Lampoudis, P. Legou, M. Lisowska, J. Liu, M. Lupberger, O. Maillard, I. Maniatis, H. Müller, E. Oliveri, T. Papaevangelou , et al. (19 additional authors not shown)

    Abstract: Timing information in current and future accelerator facilities is important for resolving objects (particle tracks, showers, etc.) in extreme large particles multiplicities on the detection systems. The PICOSEC Micromegas detector has demonstrated the ability to time 150\,GeV muons with a sub-25\,ps precision. Driven by detailed simulation studies and a phenomenological model which describes stoc… ▽ More

    Submitted 22 November, 2022; originally announced November 2022.

    Comments: 5 pages, 3 figures, 12th International Conference on Position Sensitive Detectors

    Journal ref: JINST 17 C10009 (2022)

  7. arXiv:2211.10396  [pdf, other

    physics.ins-det hep-ex hep-ph nucl-ex

    Particle Physics at the European Spallation Source

    Authors: H. Abele, A. Alekou, A. Algora, K. Andersen, S. Baessler, L. Barron-Palos, J. Barrow, E. Baussan, P. Bentley, Z. Berezhiani, Y. Bessler, A. K. Bhattacharyya, A. Bianchi, J. Bijnens, C. Blanco, N. Blaskovic Kraljevic, M. Blennow, K. Bodek, M. Bogomilov, C. Bohm, B. Bolling, E. Bouquerel, G. Brooijmans, L. J. Broussard, O. Buchan , et al. (154 additional authors not shown)

    Abstract: Presently under construction in Lund, Sweden, the European Spallation Source (ESS) will be the world's brightest neutron source. As such, it has the potential for a particle physics program with a unique reach and which is complementary to that available at other facilities. This paper describes proposed particle physics activities for the ESS. These encompass the exploitation of both the neutrons… ▽ More

    Submitted 30 January, 2024; v1 submitted 18 November, 2022; originally announced November 2022.

    Comments: 121 pages, updated version after referee comments

  8. arXiv:2206.01208  [pdf, other

    hep-ex hep-ph physics.acc-ph

    The European Spallation Source neutrino Super Beam Conceptual Design Report

    Authors: A. Alekou, E. Baussan, A. K. Bhattacharyya, N. Blaskovic Kraljevic, M. Blennow, M. Bogomilov, B. Bolling, E. Bouquerel, O. Buchan, A. Burgman, C. J. Carlile, J. Cederkall, P. Christiansen, M. Collins, E. Cristaldo Morales, P. Cupiał, L. D'Alessi, H. Danared, D. Dancila, J. P. A. M. de André, J. P. Delahaye, M. Dracos, I. Efthymiopoulos, T. Ekelöf, M. Eshraqi , et al. (51 additional authors not shown)

    Abstract: This conceptual design report provides a detailed account of the European Spallation Source neutrino Super Beam (ESS$ν$SB) feasibility study. This facility has been proposed after the measurements reported in 2012 of a relatively large value of the neutrino mixing angle $θ_{13}$, which raised the possibility of observing potential CP violation in the leptonic sector with conventional neutrino beam… ▽ More

    Submitted 2 June, 2022; originally announced June 2022.

    Comments: 216 pages

  9. arXiv:2203.08803  [pdf, other

    physics.acc-ph hep-ex

    The European Spallation Source neutrino Super Beam

    Authors: A. Alekou, E. Baussan, N. Blaskovic Kraljevic, M. Blennow, M. Bogomilov, E. Bouquerel, A. Burgman, C. J. Carlile, J. Cederkall, P. Christiansen, M. Collins, E. Cristaldo Morales, P. Cupial, L. D Alessi, H. Danared, J. P. A. M. de Andre, J. P. Delahaye, M. Dracos, I. Efthymiopoulos, T. Ekelof, M. Eshraqi, G. Fanourakis, E. Fernandez-Martinez, B. Folsom, N. Gazis , et al. (37 additional authors not shown)

    Abstract: In this Snowmass 2021 white paper, we summarise the Conceptual Design of the European Spallation Source neutrino Super Beam (ESSvSB) experiment and its synergies with the possible future muon based facilities, e.g. a Low Energy nuSTORM and the Muon Collider. The ESSvSB will benefit from the high power, 5 MW, of the European Spallation Source (ESS) LINAC in Lund-Sweden to produce the world most int… ▽ More

    Submitted 15 March, 2022; originally announced March 2022.

    Comments: contribution to Snowmass 2021

  10. arXiv:2203.06562  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Snowmass 2021 White Paper Instrumentation Frontier 05 -- White Paper 1: MPGDs: Recent advances and current R&D

    Authors: K. Dehmelt, M. Della Pietra, H. Muller, S. E. Tzamarias, A. White, S. White, Z. Zhang, M. Alviggi, I. Angelis, S. Aune, J. Bortfeldt, M. Bregant, F. Brunbauer, M. T. Camerlingo, V. Canale, V. D'Amico, D. Desforge, C. Di Donato, R. Di Nardo, G. Fanourakis, K. J. Floethner, M. Gallinaro, F. Garcia, I. Giomataris, K. Gnanvo , et al. (45 additional authors not shown)

    Abstract: This paper will review the origins, development, and examples of new versions of Micro-Pattern Gas Detectors. The goal for MPGD development was the creation of detectors that could cost-effectively cover large areas while offering excellent position and timing resolution, and the ability to operate at high incident particle rates. The early MPGD developments culminated in the formation of the RD51… ▽ More

    Submitted 19 March, 2022; v1 submitted 12 March, 2022; originally announced March 2022.

    Comments: Contribution to Snowmass 2021

  11. arXiv:2107.07585  [pdf

    hep-ex hep-ph physics.ins-det

    Updated physics performance of the ESSnuSB experiment

    Authors: A. Alekou, E. Baussan, N. Blaskovic Kraljevic, M. Blennow, M. Bogomilov, E. Bouquerel, A. Burgman, C. J. Carlile, J. Cederkall, P. Christiansen, M. Collins, E. Cristaldo Morales, L. D'Alessi, H. Danared, J. P. A. M. de André, J. P. Delahaye, M. Dracos, I. Efthymiopoulos, T. Ekelöf, M. Eshraqi, G. Fanourakis, E. Fernandez-Martinez, B. Folsom, M. Ghosh, G. Gokbulut , et al. (26 additional authors not shown)

    Abstract: In this paper, we present the physics performance of the ESSnuSB experiment in the standard three flavor scenario using the updated neutrino flux calculated specifically for the ESSnuSB configuration and updated migration matrices for the far detector. Taking conservative systematic uncertainties corresponding to a normalization error of $5\%$ for signal and $10\%$ for background, we find that the… ▽ More

    Submitted 24 December, 2021; v1 submitted 25 June, 2021; originally announced July 2021.

    Comments: 13 pages, 8 figures, 3 tables. Changes: Text updated, this is a published version

    Journal ref: Eur. Phys. J. C 81, 1130 (2021)

  12. arXiv:2012.00545  [pdf, other

    physics.ins-det hep-ex

    Timing performance of a multi-pad PICOSEC-Micromegas detector prototype

    Authors: S. Aune, J. Bortfeldt, F. Brunbauer, C. David, D. Desforge, G. Fanourakis, M. Gallinaro, F. García, I. Giomataris, T. Gustavsson, F. J. Iguaz, M. Kebbiri, K. Kordas, C. Lampoudis, P. Legou, M. Lisowska, J. Liu, M. Lupberger, O. Maillard, I. Manthos, H. Müller, E. Oliveri, T. Papaevangelou, K. Paraschou, M. Pomorski , et al. (17 additional authors not shown)

    Abstract: The multi-pad PICOSEC-Micromegas is an improved detector prototype with a segmented anode, consisting of 19 hexagonal pads. Detailed studies are performed with data collected in a muon beam over four representative pads. We demonstrate that such a device, scalable to a larger area, provides excellent time resolution and detection efficiency. As expected from earlier single-cell device studies, we… ▽ More

    Submitted 28 January, 2021; v1 submitted 1 December, 2020; originally announced December 2020.

    Comments: 29 pages, 20 figures

  13. Timing Performance of a Micro-Channel-Plate Photomultiplier Tube

    Authors: Jonathan Bortfeldt, Florian Brunbauer, Claude David, Daniel Desforge, Georgios Fanourakis, Michele Gallinaro, Francisco Garcia, Ioannis Giomataris, Thomas Gustavsson, Claude Guyot, Francisco Jose Iguaz, Mariam Kebbiri, Kostas Kordas, Philippe Legou, Jianbei Liu, Michael Lupberger, Ioannis Manthos, Hans Müller, Vasileios Niaouris, Eraldo Oliveri, Thomas Papaevangelou, Konstantinos Paraschou, Michal Pomorski, Filippo Resnati, Leszek Ropelewski , et al. (14 additional authors not shown)

    Abstract: The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. In the inner part of the circular active area (radius r$<$5.5\,mm) the time resolution of the tw… ▽ More

    Submitted 14 February, 2020; v1 submitted 27 September, 2019; originally announced September 2019.

    Comments: 6 pages, 6 figures, preprint submitted to Nuclear Instruments and Methods A

  14. arXiv:1901.10779  [pdf, other

    physics.ins-det

    Modeling the Timing Characteristics of the PICOSEC Micromegas Detector

    Authors: J. Bortfeldt, F. Brunbauer, C. David, D. Desforge, G. Fanourakis, M. Gallinaro, F. García, I. Giomataris, T. Gustavsson, F. J. Iguaz, M. Kebbiri, K. Kordas, C. Lampoudis, P. Legou, M. Lisowska, J. Liu, M. Lupberger, O. Maillard, I. Manthos, H. Müller, V. Niaouris, E. Oliveri, T . Papaevangelou, K. Paraschou, M. Pomorski , et al. (16 additional authors not shown)

    Abstract: The PICOSEC Micromegas detector can time the arrival of Minimum Ionizing Particles with a sub-25 ps precision. A very good timing resolution in detecting single photons is also demonstrated in laser beams. The PICOSEC timing resolution is determined mainly by the drift field. The arrival time of the signal and the timing resolution vary with the size of the pulse amplitude. Detailed simulations ba… ▽ More

    Submitted 2 December, 2020; v1 submitted 30 January, 2019; originally announced January 2019.

    Comments: Corresponding author S. E. Tzamarias, 47 pages, 19 figures, 2 appendices, 8 tables

  15. arXiv:1901.03355  [pdf, other

    physics.ins-det

    Precise Charged Particle Timing with the PICOSEC Detector

    Authors: J. Bortfeldt, F. Brunbauer, C. David, D. Desforge, G. Fanourakis, J. Franchi, M. Gallinaro, F. García, I. Giomataris, T. Gustavsson, C. Guyot, F. J. Iguaz, M. Kebbiri, K. Kordas, P. Legou, J. Liu, M. Lupberger, O. Maillard, I. Manthos, H. Müller, V. Niaouris, E. Oliveri, T. Papaevangelou, K. Paraschou, M. Pomorski , et al. (16 additional authors not shown)

    Abstract: The experimental requirements in near future accelerators (e.g. High Luminosity-LHC) has stimulated intense interest in development of detectors with high precision timing capabilities. With this as a goal, a new detection concept called PICOSEC, which is based to a "two-stage" MicroMegas detector coupled to a Cherenkov radiator equipped with a photocathode has been developed. Results obtained wit… ▽ More

    Submitted 10 January, 2019; originally announced January 2019.

    Comments: 7 pages, 7 figures, 10th Jubilee Conference of the Balkan Physical Union

  16. arXiv:1808.00066  [pdf, other

    hep-ex physics.ins-det

    Improved Search for Solar Chameleons with a GridPix Detector at CAST

    Authors: V. Anastassopoulos, S. Aune, K. Barth, A. Belov, H. Bräuninger, G. Cantatore, J. M. Carmona, J. F. Castel, S. A. Cetin, F. Christensen, T. Dafni, M. Davenport, A. Dermenev, K. Desch, B. Döbrich, C. Eleftheriadis, G. Fanourakis, E. Ferrer-Ribas, H. Fischer, W. Funk, J. A. García, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis , et al. (44 additional authors not shown)

    Abstract: We report on a new search for solar chameleons with the CERN Axion Solar Telescope (CAST). A GridPix detector was used to search for soft X-ray photons in the energy range from 200 eV to 10 keV from converted solar chameleons. No signiffcant excess over the expected background has been observed in the data taken in 2014 and 2015. We set an improved limit on the chameleon photon coupling,… ▽ More

    Submitted 8 November, 2018; v1 submitted 31 July, 2018; originally announced August 2018.

    Comments: 19 pages, 12 figures, 3 tables

  17. Charged particle timing at sub-25 picosecond precision: the PICOSEC detection concept

    Authors: F. J. Iguaz, J. Bortfeldt, F. Brunbauer, C. David, D. Desforge, G. Fanourakis, J. Franchi, M. Gallinaro, F. García, I. Giomataris, D. González-Díaz, T. Gustavsson, C. Guyot, M. Kebbiri, P. Legou, J. Liu, M. Lupberger, O. Maillard, I. Manthos, H. Müller, V. Niaouris, E. Oliveri, T. Papaevangelou, K. Paraschou, M. Pomorski , et al. (16 additional authors not shown)

    Abstract: The PICOSEC detection concept consists in a "two-stage" Micromegas detector coupled to a Cherenkov radiator and equipped with a photocathode. A proof of concept has already been tested: a single-photoelectron response of 76 ps has been measured with a femtosecond UV laser at CEA/IRAMIS, while a time resolution of 24 ps with a mean yield of 10.4 photoelectrons has been measured for 150 GeV muons at… ▽ More

    Submitted 4 August, 2018; v1 submitted 12 June, 2018; originally announced June 2018.

    Comments: 4 pages, 7 figures, proceedings of the 14th Pisa Meeting on Advanced Detectors (PM2018), submitted to Nucl. Instr. Meth. A; version 2: 2 figures modified, minor changes in the text

  18. arXiv:1801.04768  [pdf

    physics.ins-det hep-ex

    Operation and performance of a pilot HELYCON cosmic ray telescope with 3 stations

    Authors: Theodore Avgitas, George Bourlis, George K. Fanourakis, Ioannis Gkialas, Antonios Leisos, Ioannis Manthos, Andreas Stamelakis, Apostolos Tsirigotis, Spyros E. Tzamarias

    Abstract: Three autonomous HELYCON stations have been installed, calibrated and operated at the Hellenic Open University campus, detecting cosmic ray air showers. A software package for the detailed simulation of the detectors' response and the stations' operation has been developed. In this work we present the results of the analysis of the data collected by the stations during a period of one year and a h… ▽ More

    Submitted 15 January, 2018; originally announced January 2018.

    Comments: 20 pages, 22 figures

  19. PICOSEC: Charged particle timing at sub-25 picosecond precision with a Micromegas based detector

    Authors: J. Bortfeldt, F. Brunbauer, C. David, D. Desforge, G. Fanourakis, J. Franchi, M. Gallinaro, I. Giomataris, D. González-Díaz, T. Gustavsson, C. Guyot, F. J. Iguaz, M. Kebbiri, P. Legou, J. Liu, M. Lupberger, O. Maillard, I. Manthos, H. Müller, V. Niaouris, E. Oliveri, T. Papaevangelou, K. Paraschou, M. Pomorski, B. Qi , et al. (15 additional authors not shown)

    Abstract: The prospect of pileup induced backgrounds at the High Luminosity LHC (HL-LHC) has stimulated intense interest in develo** technologies for charged particle detection with accurate timing at high rates. The required accuracy follows directly from the nominal interaction distribution within a bunch crossing ($σ_z\sim5$ cm, $σ_t\sim170$ ps). A time resolution of the order of 20-30 ps would lead to… ▽ More

    Submitted 14 March, 2018; v1 submitted 14 December, 2017; originally announced December 2017.

    Comments: 27 pages, 15 figures, preprint submitted to Nuclear Instruments and Methods A, v2: typos fixed and an improved discussion, v3: revised version

  20. arXiv:1705.02290  [pdf, other

    hep-ex physics.ins-det

    New CAST Limit on the Axion-Photon Interaction

    Authors: CAST collaboration, V. Anastassopoulos, S. Aune, K. Barth, A. Belov, H. Brauninger, G. Cantatore, J. M. Carmona, J. F. Castel, S. A. Cetin, F. Christensen, J. I. Collar, T. Dafni, M. Davenport, T. A. Decker, A. Dermenev, K. Desch, C. Eleftheriadis, G. Fanourakis, E. Ferrer-Ribas, H. Fischer, J. A. Garcia, A. Gardikiotis, J. G. Garza, E. N. Gazis , et al. (42 additional authors not shown)

    Abstract: During 2003--2015, the CERN Axion Solar Telescope (CAST) has searched for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. In its final phase of solar axion searches (2013--2015), CAST has returned to evacuated magnet pipes, which is optimal for small axion masses. The absence of a significant signal above background provides a worl… ▽ More

    Submitted 20 December, 2017; v1 submitted 5 May, 2017; originally announced May 2017.

    Comments: Second version after referees comments (post-print). Published version available Open Access at https://www.nature.com/articles/nphys4109

    Journal ref: Nature Phys. 13 (2017) 584-590

  21. arXiv:1702.04902  [pdf

    physics.ins-det

    Deployment and calibration procedures for accurate timing and directional reconstruction of EAS particle-fronts with HELYCON stations

    Authors: Theodore Avgitas, George Bourlis, George K. Fanourakis, Ioannis Gkialas, Antonios Leisos, Ioannis Manthos, Apostolos Tsirigotis, Spyros E. Tzamarias

    Abstract: High energy cosmic rays, with energies thousands of times higher than those encountered in particle accelerators, offer scientists the means of investigating the elementary properties of matter. In order to detect high energy cosmic rays, new detection hardware and experimental methods are being developed. In this work, we describe the network of HELYCON (HEllenic LYceum Cosmic Observatories Netwo… ▽ More

    Submitted 16 February, 2017; originally announced February 2017.

    Comments: 34 pages, 26 figures

  22. arXiv:1503.04561  [pdf, other

    astro-ph.SR hep-ph physics.ins-det

    Search for chameleons with CAST

    Authors: V. Anastassopoulos, M. Arik, S. Aune, K. Barth, A. Belov, H. Bräuninger, G. Cantatore, J. M. Carmona, S. A. Cetin, F. Christensen, J. I. Collar, T. Dafni, M. Davenport, K. Desch, A. Dermenev, C. Eleftheriadis, G. Fanourakis, E. Ferrer-Ribas, P. Friedrich, J. Galán, J. A. García, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis , et al. (39 additional authors not shown)

    Abstract: In this work we present a search for (solar) chameleons with the CERN Axion Solar Telescope (CAST). This novel experimental technique, in the field of dark energy research, exploits both the chameleon coupling to matter ($β_{\rm m}$) and to photons ($β_γ$) via the Primakoff effect. By reducing the X-ray detection energy threshold used for axions from 1$\,$keV to 400$\,$eV CAST became sensitive to… ▽ More

    Submitted 18 March, 2016; v1 submitted 16 March, 2015; originally announced March 2015.

    Comments: 8 pages, 12 figures

  23. arXiv:1503.00610  [pdf, ps, other

    hep-ex physics.ins-det

    New solar axion search in CAST with $^4$He filling

    Authors: M. Arik, S. Aune, K. Barth, A. Belov, H. Bräuninger, J. Bremer, V. Burwitz, G. Cantatore, J. M. Carmona, S. A. Cetin, J. I. Collar, E. Da Riva, T. Dafni, M. Davenport, A. Dermenev, C. Eleftheriadis, N. Elias, G. Fanourakis, E. Ferrer-Ribas, J. Galán, J. A. García, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis , et al. (38 additional authors not shown)

    Abstract: The CERN Axion Solar Telescope (CAST) searches for $a\toγ$ conversion in the 9 T magnetic field of a refurbished LHC test magnet that can be directed toward the Sun. Two parallel magnet bores can be filled with helium of adjustable pressure to match the X-ray refractive mass $m_γ$ to the axion search mass $m_a$. After the vacuum phase (2003--2004), which is optimal for $m_a\lesssim0.02$ eV, we use… ▽ More

    Submitted 11 June, 2015; v1 submitted 2 March, 2015; originally announced March 2015.

    Comments: CAST Collaboration 6 pages 3 figures

    Journal ref: Phys. Rev. D 92, 021101 (2015)

  24. arXiv:1502.04317  [pdf, other

    physics.acc-ph hep-ex

    A Storage Ring Experiment to Detect a Proton Electric Dipole Moment

    Authors: V. Anastassopoulos, S. Andrianov, R. Baartman, M. Bai, S. Baessler, J. Benante, M. Berz, M. Blaskiewicz, T. Bowcock, K. Brown, B. Casey, M. Conte, J. Crnkovic, G. Fanourakis, A. Fedotov, P. Fierlinger, W. Fischer, M. O. Gaisser, Y. Giomataris, M. Grosse-Perdekamp, G. Guidoboni, S. Haciomeroglu, G. Hoffstaetter, H. Huang, M. Incagli , et al. (66 additional authors not shown)

    Abstract: A new experiment is described to detect a permanent electric dipole moment of the proton with a sensitivity of $10^{-29}e\cdot$cm by using polarized "magic" momentum $0.7$~GeV/c protons in an all-electric storage ring. Systematic errors relevant to the experiment are discussed and techniques to address them are presented. The measurement is sensitive to new physics beyond the Standard Model at the… ▽ More

    Submitted 15 February, 2015; originally announced February 2015.

    Comments: 8 pages, 3 figures

  25. Measuring the Polarization of a Rapidly Precessing Deuteron Beam

    Authors: Z. Bagdasarian, S. Bertelli, D. Chiladze, G. Ciullo, J. Dietrich, S. Dymov, D. Eversmann, G. Fanourakis, M. Gaisser, R. Gebel, B. Gou, G. Guidoboni, V. Hejny, A. Kacharava, V. Kamerdzhiev, A. Lehrach, P. Lenisa, B. Lorentz, L. Magallanes, R. Maier, D. Mchedlishvili, W. M. Morse, A. Nass, D. Oellers, A. Pesce , et al. (13 additional authors not shown)

    Abstract: This paper describes a time-marking system that enables a measurement of the in-plane (horizontal) polarization of a 0.97-GeV/c deuteron beam circulating in the Cooler Synchrotron (COSY) at the Forschungszentrum Jülich. The clock time of each polarimeter event is used to unfold the 120-kHz spin precession and assign events to bins according to the direction of the horizontal polarization. After ac… ▽ More

    Submitted 23 May, 2014; originally announced May 2014.

    Comments: 28 pages, 15 figures, prepared for Physical Review ST - Accelerators and Beams

    Journal ref: Phys. Rev, STAB 17 (2014) 052803

  26. arXiv:1401.3233  [pdf, other

    physics.ins-det hep-ex

    Conceptual Design of the International Axion Observatory (IAXO)

    Authors: E. Armengaud, F. T. Avignone, M. Betz, P. Brax, P. Brun, G. Cantatore, J. M. Carmona, G. P. Carosi, F. Caspers, S. Caspi, S. A. Cetin, D. Chelouche, F. E. Christensen, A. Dael, T. Dafni, M. Davenport, A. V. Derbin, K. Desch, A. Diago, B. Döbrich, I. Dratchnev, A. Dudarev, C. Eleftheriadis, G. Fanourakis, E. Ferrer-Ribas , et al. (63 additional authors not shown)

    Abstract: The International Axion Observatory (IAXO) will be a forth generation axion helioscope. As its primary physics goal, IAXO will look for axions or axion-like particles (ALPs) originating in the Sun via the Primakoff conversion of the solar plasma photons. In terms of signal-to-noise ratio, IAXO will be about 4-5 orders of magnitude more sensitive than CAST, currently the most powerful axion heliosc… ▽ More

    Submitted 14 January, 2014; originally announced January 2014.

    Comments: 47 pages, submitted to JINST

    Journal ref: JINST 9 (2014) T05002

  27. X-ray detection with Micromegas with background levels below 10$^{-6}$ keV$^{-1}$cm$^{-2}$s$^{-1}$

    Authors: S. Aune, F. Aznar, D. Calvet, T. Dafni, A. Diago, F. Druillole, G. Fanourakis, E. Ferrer-Ribas, J. Galán, J. A. García, A. Gardikiotis, J. G. Garza, T. Geralis, I. Giomataris, H. Gómez, D. González-Díaz, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, D. Jourde, G. Luzón, H. Mirallas, J. P. Mols, T. Papaevangelou, A. Rodríguez , et al. (4 additional authors not shown)

    Abstract: Micromegas detectors are an optimum technological choice for the detection of low energy x-rays. The low background techniques applied to these detectors yielded remarkable background reductions over the years, being the CAST experiment beneficiary of these developments. In this document we report on the latest upgrades towards further background reductions and better understanding of the detector… ▽ More

    Submitted 16 December, 2013; originally announced December 2013.

    Journal ref: JINST 8 (2013) C12042

  28. Low background x-ray detection with Micromegas for axion research

    Authors: S. Aune, J. F. Castel, T. Dafni, M. Davenport, G. Fanourakis, E. Ferrer-Ribas, J. Galan, J. A. Garcia, A. Gardikiotis, T. Geralis, I. Giomataris, H. Gomez, J. G. Garza, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, D. Jourde, G. Luzon, J. P. Mols, T. Papaevangelou, A. Rodriguez, J. Ruz, L. Segui, A. Tomas, T. Vafeiadis , et al. (1 additional authors not shown)

    Abstract: Axion helioscopes aim at the detection of solar axions through their conversion into x-rays in laboratory magnetic fields. The use of low background x-ray detectors is an essential component contributing to the sensitivity of these searches. Here we review the recent advances on Micromegas detectors used in the CERN Axion Solar Telescope (CAST) and proposed for the future International Axion Obser… ▽ More

    Submitted 12 October, 2013; originally announced October 2013.

    Comments: 26 pages, 21 figures

    Journal ref: S Aune et al 2014 JINST 9 P010011

  29. arXiv:1307.1985  [pdf, ps, other

    hep-ex astro-ph.IM physics.ins-det

    CAST solar axion search with 3^He buffer gas: Closing the hot dark matter gap

    Authors: M. Arik, S. Aune, K. Barth, A. Belov, S. Borghi, H. Brauninger, G. Cantatore, J. M. Carmona, S. A. Cetin, J. I. Collar, E. Da Riva, T. Dafni, M. Davenport, C. Eleftheriadis, N. Elias, G. Fanourakis, E. Ferrer-Ribas, P. Friedrich, J. Galan, J. A. Garcia, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis, E. Georgiopoulou , et al. (50 additional authors not shown)

    Abstract: The CERN Axion Solar Telescope (CAST) has finished its search for solar axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV. This closes the gap to the cosmological hot dark matter limit and actually overlaps with it. From the absence of excess X-rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g_ag < 3.3 x 10^{-10}… ▽ More

    Submitted 15 September, 2014; v1 submitted 8 July, 2013; originally announced July 2013.

    Comments: 5 pages, 2 figures. Last version uploaded

    Journal ref: Phys. Rev. Lett. 112, 091302 (2014)

  30. arXiv:1302.3273  [pdf, ps, other

    physics.ins-det hep-ex

    IAXO - The International Axion Observatory

    Authors: J. K. Vogel, F. T. Avignone, G. Cantatore, J. M. Carmona, S. Caspi, S. A. Cetin, F. E. Christensen, A. Dael, T. Dafni, M. Davenport, A. V. Derbin, K. Desch, A. Diago, A. Dudarev, C. Eleftheriadis, G. Fanourakis, E. Ferrer-Ribas, J. Galan, J. A. Garcia, J. G. Garza, T. Geralis, B. Gimeno, I. Giomataris, S. Gninenko, H. Gomez , et al. (39 additional authors not shown)

    Abstract: The International Axion Observatory (IAXO) is a next generation axion helioscope aiming at a sensitivity to the axion-photon coupling of a few 10^{-12} GeV^{-1}, i.e. 1-1.5 orders of magnitude beyond sensitivities achieved by the currently most sensitive axion helioscope, the CERN Axion Solar Telescope (CAST). Crucial factors in improving the sensitivity for IAXO are the increase of the magnetic f… ▽ More

    Submitted 13 February, 2013; originally announced February 2013.

    Comments: 6 pages, 1 figure, Contribution to the 8th Patras Workshop on Axions, WIMPs and WISPs, Chicago, IL, USA, 2012

  31. arXiv:1208.5690  [pdf, other

    physics.ins-det astro-ph.SR hep-ex

    CAST microbulk micromegas in the Canfranc Underground Laboratory

    Authors: A. Tomás, S. Aune, T. Dafni, G. Fanourakis, E. Ferrer-Ribas, J. Galán, J. A. García, A. Gardikiotis, T. Geralis, I. Giomataris, H. Gómez, J. G. Garza, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, G. Luzón, T. Papaevangelou, A. Rodríguez, J. Ruz, L. Seguí, T. Vafeiadis, S. C. Yildiz

    Abstract: During the last taking data campaigns of the CAST experiment, the micromegas detectors have achieved background levels of $\approx 5 \times 10^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ between 2 and 9 keV. This performance has been possible thanks to the introduction of the microbulk technology, the implementation of a shielding and the development of discrimination algorithms. It has motivated new studies… ▽ More

    Submitted 28 August, 2012; originally announced August 2012.

    Comments: 6 pages, 8 figures. To appear in the proceedings of the 2nd International Conference on Technology and Instrumentation for Particle Physics (TIPP 2011)

    Journal ref: Proceedings of the 2nd International Conference on Technology and Instrumentation in Particle Physics (TIPP 2011) Volume 37, 2012, Pages 478-482

  32. arXiv:1202.1074  [pdf, other

    physics.ins-det hep-ex

    Performances of Anode-resistive Micromegas for HL-LHC

    Authors: J. Manjarres, T. Alexopoulos, D. Attie, M. Boyer, J. Derre, G. Fanourakis, E. Ferrer-Ribas, J. Galan, E. Gazis, T. Geralis, A. Giganon, I. Giomataris, S. Herlant, F. Jeanneau, Ph. Schune, M. Titov, G. Tsipolitis

    Abstract: Micromegas technology is a promising candidate to replace Atlas forward muon chambers -tracking and trigger- for future HL-LHC upgrade of the experiment. The increase on background and pile-up event probability requires detector performances which are currently under studies in intensive RD activities. We studied performances of four different resistive Micromegas detectors with different read-o… ▽ More

    Submitted 6 February, 2012; originally announced February 2012.

    Comments: "Presented at the 2011 Hadron Collider Physics symposium (HCP-2011), Paris, France, November 14-18 2011, 3 pages, 6 figures. "

  33. arXiv:1201.1843  [pdf, other

    physics.ins-det hep-ex

    Performances and ageing study of resistive-anodes Micromegas detectors for HL-LHC environment

    Authors: F. Jeanneau, T. Alexopoulos, D. Attié, M. Boyer, J. Derré, G. Fanourakis, E. Ferrer-Ribas, J. Galán, E. Gazis, T. Geralis, A. Giganon, I. Giomataris, S. Herlant, J. Manjarrés, E. Ntomari, Ph. Schune, M. Titov, G. Tsipolitis

    Abstract: With the tenfold luminosity increase envisaged at the HL-LHC, the background (photons, neutrons, ...) and the event pile-up probability are expected to increase in proportion in the different experiments, especially in the forward regions like, for instance, the muons chambers of the ATLAS detector. Detectors based on the Micromegas principle should be good alternatives for the detector upgrade in… ▽ More

    Submitted 9 January, 2012; originally announced January 2012.

  34. arXiv:1110.2608  [pdf, other

    physics.ins-det astro-ph.IM

    Low X-ray bakground measurements at the Underground Canfranc Laboratory

    Authors: J. Galan, S. Aune, T. Dafni, G. Fanourakis, E. Ferrer-Ribas, J. A. Garcia, A. Gardikiotis, T. Geralis, I. Giomataris, H. Gomez, J. G. Garza, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, G. Luzon, T. Papaevangelou, A. Rodriguez, J. Ruz, L. Segui, A. Tomas, T. Vafeiadis, S. C. Yildiz

    Abstract: Micromegas detectors, thanks to the good spatial and temporal discrimination capabilities, are good candidates for rare event search experiments. Recent X-ray background levels achieved by these detectors in the CAST experiment have motivated further studies in the nature of the background levels measured. In particular, different shielding configurations have been tested at the Canfranc Undergrou… ▽ More

    Submitted 25 October, 2011; v1 submitted 12 October, 2011; originally announced October 2011.

    Comments: Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011

  35. arXiv:1109.4021  [pdf, other

    physics.ins-det hep-ex

    Status of R&D on Micromegas for Rare Event Searches: The T-REX project

    Authors: I. G. Irastorza, J. Castel, S. Cebrián, T. Dafni, G. Fanourakis, E. Ferrer-Ribas, D. Fortuño, L. Esteban, J. Galán, J. A. García, A. Gardikiotis, J. G. Garza, T. Geralis, I. Giomataris, H. Gómez, D. C. Herrera, F. J. Iguaz, G. Luzón, J. P. Mols, A. Ortiz, T. Papaevangelou, A. Rodríguez, J. Ruz, L. Seguí, A. Tomás , et al. (2 additional authors not shown)

    Abstract: The T-REX project aims at develo** novel readout techniques for Time Projection Chambers in experiments searching for rare events. The enhanced performance of the latest Micromegas readouts in issues like energy resolution, gain stability, homogeneity, material budget, combined with low background techniques, is opening new windows of opportunity for their application in this field. Here we revi… ▽ More

    Submitted 19 September, 2011; originally announced September 2011.

    Comments: Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011

  36. The Micromegas detector of the CAST experiment

    Authors: P. Abbon, S. Andriamonje, S. Aune, T. Dafni, M. Davenport, E. Delagnes, R. de Oliveira, G. Fanourakis, E. Ferrer Ribas, J. Franz, T. Geralis, M. Gros, Y. Giomataris, I. G. Irastorza, K. Kousouris, J. Morales, T. Papaevangelou, J. Ruz, K. Zachariadou, K. Zioutas

    Abstract: A low background Micromegas detector has been operating in the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector, made out of low radioactivity materials, operated efficiently and achieved a very low level of background rejection (5 x 10^-5 counts/keV/cm^2/s) without shielding.

    Submitted 22 February, 2007; originally announced February 2007.

    Comments: 13 pages, 12 figures and images, submitted to New Journal of

    Journal ref: NewJ.Phys.9:170,2007

  37. Performance of the Micromegas detector in the CAST experiment

    Authors: S. Aune, T. Dafni, G. Fanourakis, E. Ferrer Ribas, T. Geralis, A. Giganon, Y. Giomataris, I. G. Irastorza, K. Kousouris, K. Zachariadou

    Abstract: The gaseous Micromegas detector designed for the CERN Axion search experiment CAST, operated smoothly during Phase-I, which included the 2003 and 2004 running periods. It exhibited linear response in the energy range of interest (1-10keV), good spatial sensitivity and energy resolution (15-19% FWHM at 5.9keV)as well as remarkable stability. The detector's upgrade for the 2004 run, supported by t… ▽ More

    Submitted 12 December, 2005; originally announced December 2005.

    Comments: Prepared for PSD7: The Seventh International Conference on Position Sensitive Detectors, Liverpool, United Kingdom, 12-16 Sep. 2005

    Journal ref: Nucl.Instrum.Meth.A573:38-40,2007

  38. Progress on a spherical TPC for low energy neutrino detection

    Authors: S Aune, P Colas, H Deschamps, J Dolbeau, G Fanourakis, E Ferrer Ribas, T Enqvist, T Geralis, Y Giomataris, P Gorodetzky, G J Gounaris, M Gros, I G Irastorza, K Kousouris, V Lepeltier, J Morales, T Patzak, E A Paschos, P Salin, I Savvidis, J. D. Vergados

    Abstract: The new concept of the spherical TPC aims at relatively large target masses with low threshold and background, kee** an extremely simple and robust operation. Such a device would open the way to detect the neutrino-nucleus interaction, which, although a standard process, remains undetected due to the low energy of the neutrino-induced nuclear recoils. The progress in the development of the fis… ▽ More

    Submitted 26 November, 2005; originally announced November 2005.

    Comments: 3 pages, talk given at the 9th Workshop on Topics in Astroparticle and Underground Physics, Zaragoza, September 10-14

    Journal ref: J.Phys.Conf.Ser. 39 (2006) 281-283

  39. A low background Micromegas detector for the CAST experiment

    Authors: P. Abbon, S. Andriamonje, S. Aune, D. Besin, S. Cazaux, P. Contrepois, T. Dafni, T. Decker, N. Duportail, G. Fanourakis, E. Ferrer Ribas, T. Geralis, A. Giganon, I. Giomataris, M. Gros, R. Hill, I. G. Irastorza, K. Kousouris, J. Morales, M. Pivovaroff, M. Riallot, R. Soufli, K. Zachariadou, G. Zaffanela

    Abstract: A low background Micromegas detector has been operating on the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector operated efficiently and achieved a very low level of background rejection ($5\times 10^{-5}$ counts keV$^{-1}$cm$^{-2}$s$^{-1}$) thanks to its good spatial and energy resolution as well as the low radioactivity m… ▽ More

    Submitted 28 October, 2005; originally announced October 2005.

    Comments: 6 pages, 3 figures To appear on the proceedings of the 9th ICATPP Conference on AStroparticle, Particle, Space Physics, Detectors and Medical Physics Applications