Monte Carlo analysis of the contributions of long-lived positronium to the spectra of positron-impact-induced secondary electrons measured using an annihilation-gamma-triggered time-of-flight spectrometer
Authors:
S. Lotfimarangloo,
V. A. Chirayath,
S. Mukherjee,
H. Akafzade,
A. J. Fairchild,
R. W. Gladen,
A. R. Koymen,
A. H. Weiss
Abstract:
Magnetic bottle Time-of-Flight (ToF) spectrometers can measure the energy spectra of all electrons emitted into a 2$π$ sr solid angle simultaneously, greatly reducing data collection time. When the detection of the annihilation gamma ($γ$) and the detection of the electron (e) are used as timing signals for ToF spectrometers, the e-$γ$ time difference spectra (e-$γ$ TDS) are reflective of the posi…
▽ More
Magnetic bottle Time-of-Flight (ToF) spectrometers can measure the energy spectra of all electrons emitted into a 2$π$ sr solid angle simultaneously, greatly reducing data collection time. When the detection of the annihilation gamma ($γ$) and the detection of the electron (e) are used as timing signals for ToF spectrometers, the e-$γ$ time difference spectra (e-$γ$ TDS) are reflective of the positron-induced electron energy distributions provided the times between the impact of the positrons and the emission of the annihilation gammas are short compared to the flight times of the electrons. This is typically the case since positrons have short lifetime in solids ($\sim$ 100 - 500 ps) compared to the flight times of the secondary electrons ($10^2$ ns to $10^3$ ns). However, if the positron leaves the surface as a positronium atom (a bound electron-positron state), the annihilation gamma photons can be appreciably delayed due to the longer ortho-positronium (o-Ps) lifetime. This can result in an e-$γ$ TDS having an exponential tail with a decay constant related to the o-Ps lifetime. Here, we present an analysis of the e-$γ$ TDS using a Monte Carlo model which estimates the spectral contributions resulting from o-Ps annihilations. By removing the contributions from the delayed gamma signal, the energy spectrum of Positron Impact-Induced Secondary electrons (PIISE) can be isolated. Furthermore, our analysis allows an estimation of the intensity of the exponential tail in the e-$γ$ TDS providing a method to measure the fraction of positrons that form Ps at solid surfaces without relying on assumed 100% Ps emitting surfaces for calibration.
△ Less
Submitted 5 April, 2023; v1 submitted 24 March, 2023;
originally announced March 2023.
-
Identification of Auger mechanisms responsible for low energy electron emission from graphene on copper using Auger-gamma coincidence spectroscopy
Authors:
R. W. Gladen,
V. A. Chirayath,
P. A. Sterne,
A. J. Fairchild,
A. R. Koymen,
A. H. Weiss
Abstract:
We present a novel method for the analysis of the Doppler broadened spectrum of gamma photons emitted following the annihilation of surface trapped positrons with the electrons of bilayer graphene supported on polycrystalline Cu substrate. The method relies on the measurement of the energy of the Doppler shifted annihilation gamma photons in coincidence with the Auger electrons emitted following t…
▽ More
We present a novel method for the analysis of the Doppler broadened spectrum of gamma photons emitted following the annihilation of surface trapped positrons with the electrons of bilayer graphene supported on polycrystalline Cu substrate. The method relies on the measurement of the energy of the Doppler shifted annihilation gamma photons in coincidence with the Auger electrons emitted following the decay of the contemporaneously produced annihilation induced hole. Through the selection of annihilation gamma corresponding to O KVV (adsorbed O), C KVV (graphene), and Cu MVV (substrate) Auger transitions, we have decomposed the annihilation gamma spectrum into spectral components representing annihilation of the positron with 1s electrons of C and O and 3p electrons of Cu. These experimentally derived Doppler broadened gamma line shapes agrees well with the theoretically derived model line shapes demonstrating the ability of our method to resolve a complex Doppler line shapes into its veiled electronic level constituents which has, heretofore, only been achieved through theoretical analysis. We have also demonstrated the reversibility of the analysis method by decomposing the Auger spectra into regions which corresponds to the annihilation gamma photons with a large Doppler shift or to Auger spectra correlated with annihilation gamma photons with a small doppler shift. The reverse analysis provides additional proof that Auger transitions following deep valence annihilations result in the emission of low energy electrons.
△ Less
Submitted 5 May, 2021; v1 submitted 27 July, 2020;
originally announced July 2020.
-
Efficient Machine Learning Approach for Optimizing the Timing Resolution of a High Purity Germanium Detector
Authors:
R. W. Gladen,
V. A. Chirayath,
A. J. Fairchild,
M. T. Manry,
A. R. Koymen,
A. H. Weiss
Abstract:
We describe here an efficient machine-learning based approach for the optimization of parameters used for extracting the arrival time of waveforms, in particular those generated by the detection of 511 keV annihilation gamma-rays by a 60 cm3 coaxial high purity germanium detector (HPGe). The method utilizes a type of artificial neural network (ANN) called a self-organizing map (SOM) to cluster the…
▽ More
We describe here an efficient machine-learning based approach for the optimization of parameters used for extracting the arrival time of waveforms, in particular those generated by the detection of 511 keV annihilation gamma-rays by a 60 cm3 coaxial high purity germanium detector (HPGe). The method utilizes a type of artificial neural network (ANN) called a self-organizing map (SOM) to cluster the HPGe waveforms based on the shape of their rising edges. The optimal timing parameters for HPGe waveforms belonging to a particular cluster are found by minimizing the time difference between the HPGe signal and a signal produced by a BaF2 scintillation detector. Applying these variable timing parameters to the HPGe signals achieved a gamma-coincidence timing resolution of ~ 4.3 ns at the 511 keV photo peak (defined as 511 +- 50 keV) and a timing resolution of ~ 6.5 ns for the entire gamma spectrum--without rejecting any valid pulses. This timing resolution approaches the best obtained by analog nuclear electronics, without the corresponding complexities of analog optimization procedures. We further demonstrate the universality and efficacy of the machine learning approach by applying the method to the generation of secondary electron time-of-flight spectra following the implantation of energetic positrons on a sample.
△ Less
Submitted 31 March, 2020;
originally announced April 2020.
-
A multi-stop time-of-flight spectrometer for the measurement of positron annihilation-induced electrons in coincidence with the Doppler-shifted annihilation gamma photon
Authors:
V. A. Chirayath,
R. W. Gladen,
A. D. McDonald,
A. J. Fairchild,
P. V. Joglekar,
S. Satyal,
Z. H. Lim,
T. N. Shead,
M. D. Chrysler,
S. Mukherjee,
B. M. Barnett,
N. K. Byrnes,
A. R. Koymen,
R. G. Greaves,
A. H. Weiss
Abstract:
Here we describe an advanced multi functional, variable-energy positron beam system capable of measuring the energies of multiple positron-induced electrons in coincidence with the Doppler-shifted gamma photon resulting from the annihilation of the correlated positron. The measurements were carried out using the unique characteristics of the digital time-of-flight spectrometer and the gamma spectr…
▽ More
Here we describe an advanced multi functional, variable-energy positron beam system capable of measuring the energies of multiple positron-induced electrons in coincidence with the Doppler-shifted gamma photon resulting from the annihilation of the correlated positron. The measurements were carried out using the unique characteristics of the digital time-of-flight spectrometer and the gamma spectrometer available with the advanced positron beam system. These measurements have resulted in (i) the first digital time of flight spectrum of positron annihilation-induced Auger electrons generated using coincident signals from a high-purity Ge detector and a micro-channel plate; (ii) a two-dimensional array of the energy of Doppler-broadened annihilation gamma and the time of flight of positron-annihilation induced Auger electrons or secondary electrons measured in coincidence with the annihilation gamma photon; and (iii) the time of flight spectra of multiple secondary electrons ejected from a bilayer graphene surface as a result of the impact and(or) annihilation of positrons. The novelty of the gamma electron coincidence spectroscopy has been demonstrated by extracting the Doppler-broadened spectrum of gamma photons emitted due to the annihilation of positrons exclusively with 1s electrons of carbon. The width of the extracted Doppler-broadened gamma spectrum has been found to be consistent with the expected broadening of the annihilation gamma spectrum due to the momentum of the 1s electrons in carbon.
△ Less
Submitted 27 January, 2020;
originally announced January 2020.
-
Positron Induced Electron Emission from Graphite
Authors:
A. J. Fairchild,
V. A. Chirayath,
R. W. Gladen,
A. R. Koymen,
A. H. Weiss
Abstract:
In this paper, we present and analyze measurements of the positron induced electron spectra (PIES) from highly oriented pyrolytic graphite (HOPG). The spectra were obtained using a time of flight spectrometer attached to a variable energy positron beam. In the first measurements presented, the system was configured to obtain high resolution data from the annihilation induced KVV Auger transition o…
▽ More
In this paper, we present and analyze measurements of the positron induced electron spectra (PIES) from highly oriented pyrolytic graphite (HOPG). The spectra were obtained using a time of flight spectrometer attached to a variable energy positron beam. In the first measurements presented, the system was configured to obtain high resolution data from the annihilation induced KVV Auger transition of carbon. In the second set of data presented, PIES spectra were obtained for 3 different positron beam energies (1.25 eV, 3.5 eV and 4.5 eV). The resulting time of flight (ToF)-PIES exhibit contributions arising from either positron annihilation induced Auger processes (PAES), Auger mediated positron sticking (AMPS), or secondary electron emission. Our analysis indicates that for incident positron energies 3.5 eV and less, the ToF-PIES can be accounted for considering only two mechanisms: positron annihilation induced Auger processes or positron sticking.
△ Less
Submitted 25 July, 2019;
originally announced July 2019.
-
Coincident Measurement of the Energy Spectra of Doppler-Shifted Annihilation Gamma Quanta and Positron-Induced Secondary Electrons
Authors:
R W Gladen,
V A Chirayath,
A J Fairchild,
N K Byrnes,
A R Koymen,
A H Weiss
Abstract:
Preliminary results are presented from a new positron beam system currently under development at the University of Texas at Arlington for the coincident energy measurement of Doppler-shifted annihilation quanta and positron-induced Auger electrons. We report data based on an analysis of the pulses resulting from the detection of positron induced secondary electrons by a micro-channel plate detecto…
▽ More
Preliminary results are presented from a new positron beam system currently under development at the University of Texas at Arlington for the coincident energy measurement of Doppler-shifted annihilation quanta and positron-induced Auger electrons. We report data based on an analysis of the pulses resulting from the detection of positron induced secondary electrons by a micro-channel plate detector in coincidence with the pulses resulting from the detection of associated annihilation gamma rays in a NaI(Tl) gamma detector.
△ Less
Submitted 24 July, 2019;
originally announced July 2019.