Skip to main content

Showing 1–6 of 6 results for author: Fagot, A

Searching in archive physics. Search in all archives.
.
  1. arXiv:1807.05680  [pdf, other

    physics.ins-det hep-ex

    High Rate RPC detector for LHC

    Authors: F. Lagarde, A. Fagot, M. Gul, C. Roskas, M. Tytgat, N. Zaganidis, S. Fonseca De Souza, A. Santoro, F. Torres Da Silva De Araujo, A. Aleksandrov, R. Hadjiiska, P. Iaydjiev, M. Rodozov, M. Shopova, G. Sultanov, A. Dimitrov, L. Litov, B. Pavlov, P. Petkov, A. Petrov, S. J. Qian, D. Han, W. Yi, C. Avila, A. Cabrera , et al. (77 additional authors not shown)

    Abstract: The High Luminosity LHC (HL-LHC) phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. The foreseen gradual increase of the instantaneous luminosity of up to more than twice its nominal value of $10\times10^{34}\ {\rm cm}^{-1}{\rm s}^{-2}$ during Phase I and Phase II of the LHC running, presents special challenges for the experiments. The… ▽ More

    Submitted 16 July, 2018; originally announced July 2018.

  2. arXiv:1606.04291  [pdf, other

    physics.ins-det hep-ex

    R&D towards the CMS RPC Phase-2 upgrade

    Authors: A. Fagot, A. Cimmino, S. Crucy, M. Gul, A. A. O. Rios, M. Tytgat, N. Zaganidis, S. Aly, Y. Assran, A. Radi, A. Sayed, G. Singh, M. Abbrescia, G. Iaselli, M. Maggi, G. Pugliese, P. Verwilligen, W. Van Doninck, S. Colafranceschi, A. Sharma, L. Benussi, S. Bianco, D. Piccolo, F. Primavera, V. Bhatnagar , et al. (71 additional authors not shown)

    Abstract: The high pseudo-rapidity region of the CMS muon system is covered by Cathode Strip Chambers (CSC) only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. In order to maintain good efficiency for the muon trigger in this region additional RPCs are planned to be installed in the two outermost stations at low angle… ▽ More

    Submitted 14 June, 2016; originally announced June 2016.

    Comments: 13th Workshop on Resistive Plate Chambers and related detectors, 22-26 February 2016, Ghent University, Belgium

  3. arXiv:1606.01398  [pdf, other

    physics.ins-det hep-ex

    High rate, fast timing Glass RPC for the high η CMS muon detectors

    Authors: F. Lagarde, M. Gouzevitch, I. Laktineh, V. Buridon, X. Chen, C. Combaret, A. Eynard, L. Germani, G. Grenier, H. Mathez, L. Mirabito, A. Petrukhin, A. Steen, W. Tromeuraa, Y. Wang, A. Gongab, N. Moreau, C. de la Taille, F. Dulucqac, A. Cimmino, S. Crucy, A. Fagot, M. Gul, A. A. O. Rios, M. Tytgat , et al. (86 additional authors not shown)

    Abstract: The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6.10^{34} cm^{-2} s^{-1}$ . The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of the expec… ▽ More

    Submitted 22 July, 2016; v1 submitted 4 June, 2016; originally announced June 2016.

    Comments: 14 pages, 11 figures, Conference proceeding for the 2016 Resistive Plate Chambers and Related Detectors

  4. arXiv:1605.06798  [pdf

    physics.ins-det hep-ex

    Performance of Resistive Plate Chambers installed during the first long shutdown of the CMS experiment

    Authors: M. Shopova, A. Aleksandrov, R. Hadjiiska, P. Iaydjiev, G. Sultanov, M. Rodozov, S. Stoykova, Y. Assran, A. Sayed, A. Radi, S. Aly, G. Singh, M. Abbrescia, G. Iaselli, M. Maggi, G. Pugliese, P. Verwilligen, W. Van Doninck, S. Colafranceschi, A. Sharma, L. Benussi, S. Bianco, D. Piccolo, F. Primavera, A. Cimmino , et al. (71 additional authors not shown)

    Abstract: The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. During the first long shutdown (LS1) of the L… ▽ More

    Submitted 22 May, 2016; originally announced May 2016.

    Comments: 5 pages, 6 figures, proceeding to The XIII workshop on Resistive Plate Chambers and Related Detectors (RPC2016)

    Report number: CMS CR-2016/090

  5. arXiv:1605.00440  [pdf

    physics.ins-det hep-ex

    Radiation Tests of Real-Sized Prototype RPCs for the Future CMS RPC Upscope

    Authors: K. S. Lee, S. Choi, B. S. Hong, M. Jo, J. W. Kang, M. Kang, H. Kim, K. Lee, S. K. Parka, A. Cimmino, S. Crucy, A. Fagot, M. Gul, A. A. O. Rios, M. Tytgat, N. Zaganidis, S. Ali, Y. Assran, A. Radi, A. Sayed, G. Singh, M. Abbrescia, G. Iaselli, M. Maggi, G. Pugliese , et al. (71 additional authors not shown)

    Abstract: We report on a systematic study of double-gap and four-gap phenolic resistive plate chambers (RPCs) for future high-η RPC triggers in the CMS. In the present study, we constructed real-sized double-gap and four-gap RPCs with gap thicknesses of 1.6 and 0.8 mm, respectively, with 2-mm-thick phenolic high-pressure-laminated (HPL) plates. We examined the prototype RPCs for cosmic rays and 100 GeV muon… ▽ More

    Submitted 4 May, 2016; v1 submitted 2 May, 2016; originally announced May 2016.

    Comments: Conference proceeding for the 2016 Resistive Plate Chambers and Related Detectors 8 pages, 9 figures

  6. arXiv:1404.6454  [pdf, other

    physics.ins-det hep-ex

    The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers

    Authors: C. Adloff, J. -J. Blaising, M. Chefdeville, C. Drancourt, R. Gaglione, N. Geffroy, Y. Karyotakis, I. Koletsou, J. Prast, G. Vouters J. Repond, J. Schlereth, L. Xia E. Baldolemar, J. Li, S. T. Park, M. Sosebee, A. P. White, J. Yu, G. Eigen, M. A. Thomson, D. R. Ward, D. Benchekroun, A. Hoummada, Y. Khoulaki J. Apostolakis, S. Arfaoui, M. Benoit , et al. (188 additional authors not shown)

    Abstract: The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is m… ▽ More

    Submitted 21 July, 2014; v1 submitted 25 April, 2014; originally announced April 2014.

    Comments: 24 pages including author list, 9 figures, published in JINST

    Report number: MPP-2014-147

    Journal ref: JINST 9 (2014) P07022