-
Characterization of Charge Spreading and Gain of Encapsulated Resistive Micromegas Detectors for the Upgrade of the T2K Near Detector Time Projection Chambers
Authors:
D. Attie,
O. Ballester,
M. Batkiewicz-Kwasnia,
P. Billoir,
A. Blondel,
S. Bolognesi,
R. Boullon,
D. Calvet,
M. P. Casado,
M. G. Catanesi,
M. Cicerchia,
G. Cogo,
P. Colas,
G. Collazuol,
D. D Ago,
C. Dalmazzon,
T. Daret,
A. Delbart,
A. De Lorenzis,
R. de Oliveira,
S. Dolan,
K. Dygnarowiczi,
J. Dumarchez,
S. Emery-Schren,
A. Ershova
, et al. (70 additional authors not shown)
Abstract:
An upgrade of the near detector of the T2K long baseline neutrino oscillation experiment is currently being conducted. This upgrade will include two new Time Projection Chambers, each equipped with 16 charge readout resistive Micromegas modules. A procedure to validate the performance of the detectors at different stages of production has been developed and implemented to ensure a proper and relia…
▽ More
An upgrade of the near detector of the T2K long baseline neutrino oscillation experiment is currently being conducted. This upgrade will include two new Time Projection Chambers, each equipped with 16 charge readout resistive Micromegas modules. A procedure to validate the performance of the detectors at different stages of production has been developed and implemented to ensure a proper and reliable operation of the detectors once installed. A dedicated X-ray test bench is used to characterize the detectors by scanning each pad individually and to precisely measure the uniformity of the gain and the deposited energy resolution over the pad plane. An energy resolution of about 10% is obtained. A detailed physical model has been developed to describe the charge dispersion phenomena in the resistive Micromegas anode. The detailed physical description includes initial ionization, electron drift, diffusion effects and the readout electronics effects. The model provides an excellent characterization of the charge spreading of the experimental measurements and allowed the simultaneous extraction of gain and RC information of the modules.
△ Less
Submitted 8 March, 2023;
originally announced March 2023.
-
Analysis of test beam data taken with a prototype of TPC with resistive Micromegas for the T2K Near Detector upgrade
Authors:
D. Attié,
O. Ballester,
M. Batkiewicz-Kwasniak,
P. Billoir,
A. Blanchet,
A. Blondel,
S. Bolognesi,
R. Boullon,
D. Calvet,
M. P. Casado,
M. G. Catanesi,
M. Cicerchia,
G. Cogo,
P. Colas,
G. Collazuol,
C. Dalmazzone,
T. Daret,
A. Delbart,
A. De Lorenzis,
S. Dolan,
K. Dygnarowicz,
J. Dumarchez,
S. Emery-Schrenk,
A. Ershova,
G. Eurin
, et al. (59 additional authors not shown)
Abstract:
In this paper we describe the performance of a prototype of the High Angle Time Projection Chambers (HA-TPCs) that are being produced for the Near Detector (ND280) upgrade of the T2K experiment. The two HA-TPCs of ND280 will be instrumented with eight Encapsulated Resistive Anode Micromegas (ERAM) on each endplate, thus constituting in total 32 ERAMs. This innovative technique allows the detection…
▽ More
In this paper we describe the performance of a prototype of the High Angle Time Projection Chambers (HA-TPCs) that are being produced for the Near Detector (ND280) upgrade of the T2K experiment. The two HA-TPCs of ND280 will be instrumented with eight Encapsulated Resistive Anode Micromegas (ERAM) on each endplate, thus constituting in total 32 ERAMs. This innovative technique allows the detection of the charge emitted by ionization electrons over several pads, improving the determination of the track position. The TPC prototype has been equipped with the first ERAM module produced for T2K and with the HA-TPC readout electronics chain and it has been exposed to the DESY Test Beam in order to measure spatial and dE/dx resolution. In this paper we characterize the performances of the ERAM and, for the first time, we compare them with a newly developed simulation of the detector response. Spatial resolution better than 800 ${μ\rm m}$ and dE/dx resolution better than 10% are observed for all the incident angles and for all the drift distances of interest. All the main features of the data are correctly reproduced by the simulation and these performances fully fulfill the requirements for the HA-TPCs of T2K.
△ Less
Submitted 16 May, 2023; v1 submitted 13 December, 2022;
originally announced December 2022.
-
Scintillator ageing of the T2K near detectors from 2010 to 2021
Authors:
The T2K Collaboration,
K. Abe,
N. Akhlaq,
R. Akutsu,
A. Ali,
C. Alt,
C. Andreopoulos,
M. Antonova,
S. Aoki,
T. Arihara,
Y. Asada,
Y. Ashida,
E. T. Atkin,
S. Ban,
M. Barbi,
G. J. Barker,
G. Barr,
D. Barrow,
M. Batkiewicz-Kwasniak,
F. Bench,
V. Berardi,
L. Berns,
S. Bhadra,
A. Blanchet,
A. Blondel
, et al. (333 additional authors not shown)
Abstract:
The T2K experiment widely uses plastic scintillator as a target for neutrino interactions and an active medium for the measurement of charged particles produced in neutrino interactions at its near detector complex. Over 10 years of operation the measured light yield recorded by the scintillator based subsystems has been observed to degrade by 0.9--2.2\% per year. Extrapolation of the degradation…
▽ More
The T2K experiment widely uses plastic scintillator as a target for neutrino interactions and an active medium for the measurement of charged particles produced in neutrino interactions at its near detector complex. Over 10 years of operation the measured light yield recorded by the scintillator based subsystems has been observed to degrade by 0.9--2.2\% per year. Extrapolation of the degradation rate through to 2040 indicates the recorded light yield should remain above the lower threshold used by the current reconstruction algorithms for all subsystems. This will allow the near detectors to continue contributing to important physics measurements during the T2K-II and Hyper-Kamiokande eras. Additionally, work to disentangle the degradation of the plastic scintillator and wavelength shifting fibres shows that the reduction in light yield can be attributed to the ageing of the plastic scintillator.
△ Less
Submitted 26 July, 2022;
originally announced July 2022.
-
Optimized scintillation strip design for the DANSS upgrade
Authors:
DANSS Collaboration,
I. Alekseev,
V. Belov,
A. Bystryakov,
M. Danilov,
A. Ershova,
D. Filosofov,
M. Fomina,
S. Kazartsev,
A. Kobyakin,
N. Kozlenko,
A. Kuznetsov,
I. Machikhiliyan,
F. Mamedov,
D. Medvedev,
V. Nesterov,
D. Novinsky,
K. Perminov,
I. Rozova,
N. Rumyantseva,
V. Rusinov,
A. Salamatin,
E. Samigullin,
Ye. Shevchik,
M. Shirchenko
, et al. (10 additional authors not shown)
Abstract:
DANSS is a one cubic meter plastic scintillator detector with a primary goal of the sterile neutrino searches at a commercial nuclear reactor. Due to its highly advantageous location, fine segmentation and ability to change the distance to the neutrino production origin DANSS is ahead of many similar experiments around the world in terms of the counting rate, signal to background ratio and sterile…
▽ More
DANSS is a one cubic meter plastic scintillator detector with a primary goal of the sterile neutrino searches at a commercial nuclear reactor. Due to its highly advantageous location, fine segmentation and ability to change the distance to the neutrino production origin DANSS is ahead of many similar experiments around the world in terms of the counting rate, signal to background ratio and sterile neutrino exclusion regions. Yet a moderate energy resolution of the detector prevents the further progress in the physics program. The main challenge of the planned upgrade is to achieve the energy resolution of 12% at 1 MeV. The new design of the main sensitive element - the plastic scintillation strip - is the most important step forward. The strip prototypes were manufactured and tested at the pion beam of the PNPI synchrocyclotron. More than twice higher light output together with fairly flat detector response uniformity, longitudinal timing information and other optimizations will surely help to reach the upgrade goal. The paper discusses the drawbacks of the current strip version, outlines the new features of the proposed upgrade, describes the beam test procedure and presents the test results reflecting the advantages of the new strip design in comparison with the currently used version.
△ Less
Submitted 13 April, 2022; v1 submitted 9 December, 2021;
originally announced December 2021.