-
The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
S. Aviles,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame,
J. Bensinger
, et al. (365 additional authors not shown)
Abstract:
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherent…
▽ More
LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented.
△ Less
Submitted 28 February, 2022; v1 submitted 3 June, 2020;
originally announced June 2020.
-
The LUX-ZEPLIN (LZ) Experiment
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
A. Alquahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
A. Arbuckle,
J. E. Armstrong,
M. Arthurs,
H. Auyeung,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
J. Bang,
M. J. Barry,
J. Barthel,
D. Bauer,
P. Bauer,
A. Baxter,
J. Belle,
P. Beltrame
, et al. (357 additional authors not shown)
Abstract:
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient n…
▽ More
We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements.
△ Less
Submitted 3 November, 2019; v1 submitted 20 October, 2019;
originally announced October 2019.
-
LUX-ZEPLIN (LZ) Technical Design Report
Authors:
B. J. Mount,
S. Hans,
R. Rosero,
M. Yeh,
C. Chan,
R. J. Gaitskell,
D. Q. Huang,
J. Makkinje,
D. C. Malling,
M. Pangilinan,
C. A. Rhyne,
W. C. Taylor,
J. R. Verbus,
Y. D. Kim,
H. S. Lee,
J. Lee,
D. S. Leonard,
J. Li,
J. Belle,
A. Cottle,
W. H. Lippincott,
D. J. Markley,
T. J. Martin,
M. Sarychev,
T. E. Tope
, et al. (237 additional authors not shown)
Abstract:
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters.
△ Less
Submitted 27 March, 2017;
originally announced March 2017.
-
Identification of Radiopure Titanium for the LZ Dark Matter Experiment and Future Rare Event Searches
Authors:
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
I. J. Arnquist,
M. Arthurs,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
J. Belle,
P. Beltrame,
T. Benson,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. Bolozdynya,
B. Boxer,
R. Bramante,
P. Brás,
J. H. Buckley,
V. V. Bugaev
, et al. (180 additional authors not shown)
Abstract:
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals,…
▽ More
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals, the determination of factors limiting radiopure production, and the selection of titanium for construction of the LZ cryostat and other detector components. This titanium has been measured with activities of $^{238}$U$_{e}$~$<$1.6~mBq/kg, $^{238}$U$_{l}$~$<$0.09~mBq/kg, $^{232}$Th$_{e}$~$=0.28\pm 0.03$~mBq/kg, $^{232}$Th$_{l}$~$=0.25\pm 0.02$~mBq/kg, $^{40}$K~$<$0.54~mBq/kg, and $^{60}$Co~$<$0.02~mBq/kg (68\% CL). Such low intrinsic activities, which are some of the lowest ever reported for titanium, enable its use for future dark matter and other rare event searches. Monte Carlo simulations have been performed to assess the expected background contribution from the LZ cryostat with this radioactivity. In 1,000 days of WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute only a mean background of $0.160\pm0.001$(stat)$\pm0.030$(sys) counts.
△ Less
Submitted 26 September, 2017; v1 submitted 8 February, 2017;
originally announced February 2017.
-
LUX-ZEPLIN (LZ) Conceptual Design Report
Authors:
The LZ Collaboration,
D. S. Akerib,
C. W. Akerlof,
D. Yu. Akimov,
S. K. Alsum,
H. M. Araújo,
X. Bai,
A. J. Bailey,
J. Balajthy,
S. Balashov,
M. J. Barry,
P. Bauer,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
K. E. Boast,
A. I. Bolozdynya,
E. M. Boulton,
R. Bramante,
J. H. Buckley,
V. V. Bugaev,
R. Bunker,
S. Burdin,
J. K. Busenitz
, et al. (170 additional authors not shown)
Abstract:
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive exp…
▽ More
The design and performance of the LUX-ZEPLIN (LZ) detector is described as of March 2015 in this Conceptual Design Report. LZ is a second-generation dark-matter detector with the potential for unprecedented sensitivity to weakly interacting massive particles (WIMPs) of masses from a few GeV/c2 to hundreds of TeV/c2. With total liquid xenon mass of about 10 tonnes, LZ will be the most sensitive experiment for WIMPs in this mass region by the end of the decade. This report describes in detail the design of the LZ technical systems. Expected backgrounds are quantified and the performance of the experiment is presented. The LZ detector will be located at the Sanford Underground Research Facility in South Dakota. The organization of the LZ Project and a summary of the expected cost and current schedule are given.
△ Less
Submitted 23 September, 2015; v1 submitted 9 September, 2015;
originally announced September 2015.
-
Chronopixel Vertex Detectors for Future Linear Colliders
Authors:
C. Baltay,
W. Emmet,
D. Rabinowitz,
J. Brau,
N. Sinev,
D. Strom
Abstract:
Over the past few years we have developed, in collaboration with the SARNOFF Corporation, a design of a Monolithic CMOS Pixel Detector for ILC Vertex Detectors. The unique feature of this design is that each hit is accompanied by a time tag with sufficient precision to assign each hit to a particular bunch crossing of the ILC (thus the name Chronopixel). This reduces the occupancy even in the inne…
▽ More
Over the past few years we have developed, in collaboration with the SARNOFF Corporation, a design of a Monolithic CMOS Pixel Detector for ILC Vertex Detectors. The unique feature of this design is that each hit is accompanied by a time tag with sufficient precision to assign each hit to a particular bunch crossing of the ILC (thus the name Chronopixel). This reduces the occupancy even in the innermost Vertex Detector layer to negligible levels, allowing a robust Vertex Detector even in the case that the backgrounds in the ILC are higher than presently estimated.
△ Less
Submitted 13 September, 2011;
originally announced September 2011.
-
Status of the Chronopixel Project
Authors:
C. Baltay,
J. Brau,
W. Emmet,
D. Rabinovich,
N. Sinev,
D. Strom
Abstract:
Other the past few years we have developed a monolithic CMOS pixel detector design for the ILC in collaboration with the SARNOFF Corporation. The unique feature of this design is the recorded time tag for each hit, allowing assignment of the hit to a particular bunch crossing (thus the name Chronopixel). The prototype design was completed in 2007. The first set of prototype devices was fabricate…
▽ More
Other the past few years we have developed a monolithic CMOS pixel detector design for the ILC in collaboration with the SARNOFF Corporation. The unique feature of this design is the recorded time tag for each hit, allowing assignment of the hit to a particular bunch crossing (thus the name Chronopixel). The prototype design was completed in 2007. The first set of prototype devices was fabricated in 2008. We have developed a detailed testing plan and have designed the test electronics in collaboration with SLAC. Testing is expected to start early in 2009.
△ Less
Submitted 12 February, 2009;
originally announced February 2009.