-
Neurological disorders leading to mechanical dysfunction of the esophagus: an emergent behavior of a neuromechanical dynamical system
Authors:
Guy Elisha,
Sourav Halder,
Xinyi Liu,
Dustin A. Carlson,
Peter J. Kahrilas,
John E. Pandolfino,
Neelesh A. Patankar
Abstract:
An understanding how neurological disorders lead to mechanical dysfunction of the esophagus requires knowledge of the neural circuit of the enteric nervous system. Historically, this has been elusive. Here, we present an empirically guided neural circuit for the esophagus. It has a chain of unidirectionally coupled relaxation oscillators, receiving excitatory signals from stretch receptors along t…
▽ More
An understanding how neurological disorders lead to mechanical dysfunction of the esophagus requires knowledge of the neural circuit of the enteric nervous system. Historically, this has been elusive. Here, we present an empirically guided neural circuit for the esophagus. It has a chain of unidirectionally coupled relaxation oscillators, receiving excitatory signals from stretch receptors along the esophagus. The resulting neuromechanical model reveals complex patterns and behaviors that emerge from interacting components in the system. A wide variety of clinically observed normal and abnormal esophageal responses to distension are successfully predicted. Specifically, repetitive antegrade contractions (RACs) are conclusively shown to emerge from the coupled neuromechanical dynamics in response to sustained volumetric distension. Normal RACs are shown to have a robust balance between excitatory and inhibitory neuronal populations, and the mechanical input through stretch receptors. When this balance is affected, contraction patterns akin to motility disorders are observed. For example, clinically observed repetitive retrograde contractions emerge due to a hyper stretch sensitive wall. Such neuromechanical insights could be crucial to eventually develop targeted pharmacological interventions.
△ Less
Submitted 1 March, 2024; v1 submitted 28 February, 2024;
originally announced February 2024.
-
Direct and retrograde signal propagation in unidirectionally coupled Wilson-Cowan oscillators
Authors:
Guy Elisha,
Richard Gast,
Sourav Halder,
Sara A. Solla,
Peter J. Kahrilas,
John E. Pandolfino,
Neelesh A. Patankar
Abstract:
Certain biological systems exhibit both direct and retrograde propagating wave signals, despite unidirectional neural coupling. However, there is no model to explain this. Therefore, the underlying physics of reversing the signal's direction for one-way coupling remains unclear. Here, we resolve this issue using a Wilson-Cowan oscillators network. By analyzing the limit cycle period of various cou…
▽ More
Certain biological systems exhibit both direct and retrograde propagating wave signals, despite unidirectional neural coupling. However, there is no model to explain this. Therefore, the underlying physics of reversing the signal's direction for one-way coupling remains unclear. Here, we resolve this issue using a Wilson-Cowan oscillators network. By analyzing the limit cycle period of various coupling configurations, we determine that intrinsic frequency differences among oscillators control wave directionality.
△ Less
Submitted 1 March, 2024; v1 submitted 28 February, 2024;
originally announced February 2024.
-
A mechanics--based perspective on the function of human sphincters during functional luminal imaging probe manometry
Authors:
Guy Elisha,
Sourav Halder,
Dustin A. Carlson,
Wenjun Kou,
Peter J. Kahrilas,
John E. Pandolfino,
Neelesh A. Patankar
Abstract:
Functional luminal imaging probe (FLIP) is used to measure cross-sectional area (CSA) and pressure at sphincters. It consists of a catheter surrounded by a fluid filled cylindrical bag, closed on both ends. Plotting the pressure-CSA hysteresis of a sphincter during a contraction cycle, which is available through FLIP testing, offers information on its functionality, and can provide diagnostic insi…
▽ More
Functional luminal imaging probe (FLIP) is used to measure cross-sectional area (CSA) and pressure at sphincters. It consists of a catheter surrounded by a fluid filled cylindrical bag, closed on both ends. Plotting the pressure-CSA hysteresis of a sphincter during a contraction cycle, which is available through FLIP testing, offers information on its functionality, and can provide diagnostic insights. However, limited work has been done to explain the mechanics of these pressure-CSA loops. This work presents a consolidated picture of pressure-CSA loops of different sphincters. Clinical data reveal that although sphincters have a similar purpose (controlling the flow of liquids and solids by opening and closing), two different pressure-CSA loop patterns emerge: negative slope loop (NSL) and positive slope loop (PSL). We show that the loop type is the result of an interplay between (or lack thereof) two mechanical modes: (i) neurogenic mediated relaxation of the sphincter muscle and (ii) muscle contraction proximal to the sphincter which causes mechanical distention. We conclude that sphincters which only function through mechanism (i) exhibition NSL whereas sphincters which open as a result of both (i) and (ii) display a PSL. This work provides a fundamental mechanical understanding of human sphincters. This can be used to identify normal and abnormal phenotypes for the different sphincters and help in creating physiomarkers based on work calculation.
△ Less
Submitted 17 September, 2022;
originally announced September 2022.
-
Pressure -- area loop based phenotypic classification and mechanics of esophagogastric junction physiology
Authors:
Guy Elisha,
Sourav Halder,
Shashank Acharya,
Dustin A. Carlson,
Wenjun Kou,
Peter J. Kahrilas,
John E. Pandolfino,
Neelesh A. Patankar
Abstract:
The esophagogastric junction (EGJ) is located at the distal end of the esophagus and acts as a valve allowing swallowed materials to enter the stomach and preventing acid reflux. Irregular weakening or stiffening of the EGJ muscles result in changes to its opening and closing patterns which can progress into esophageal disorders. Therefore, understanding the physics behind the opening and closing…
▽ More
The esophagogastric junction (EGJ) is located at the distal end of the esophagus and acts as a valve allowing swallowed materials to enter the stomach and preventing acid reflux. Irregular weakening or stiffening of the EGJ muscles result in changes to its opening and closing patterns which can progress into esophageal disorders. Therefore, understanding the physics behind the opening and closing cycle of the EGJ provides a mechanistic insight into its function and can help identify the underlying conditions that cause its degradation. Using clinical FLIP data, we plotted the pressure-area hysteresis at the EGJ location and distinguished two major loop types, a pressure dominant loop (PDL) and a tone dominant loop (TDL). In this study, we aimed to identify the key characteristics that define each loop type and find what causes the inversion from one loop to another. To do so, the clinical observations were reproduced using 1D simulations of flow inside a FLIP device located in the esophagus, and the work done by the EGJ wall over time was calculated. This work was decomposed into active and passive components, which revealed the competing mechanisms that dictate the loop type. These mechanisms are esophagus stiffness, fluid viscosity, and the EGJ relaxation pattern. In PDL, the leading source of energy in the cycle is coming from the fluid pressure increase from the peristaltic contraction wave, and in TDL the leading source of energy in the cycle is coming from the contraction and relaxation of the EGJ tone.
△ Less
Submitted 4 January, 2022;
originally announced January 2022.
-
Peristaltic regimes in esophageal transport
Authors:
Guy Elisha,
Shashank Acharya,
Sourav Halder,
Dustin A. Carlson,
Wenjun Kou,
Peter J. Kahrilas,
John E. Pandolfino,
Neelesh A. Patankar
Abstract:
A FLIP device gives cross-sectional area along the length of the esophagus and one pressure measurement, both as a function of time. Deducing mechanical properties of the esophagus including wall material properties, contraction strength, and wall relaxation from these data is a challenging inverse problem. Knowing mechanical properties can change how clinical decisions are made because of its pot…
▽ More
A FLIP device gives cross-sectional area along the length of the esophagus and one pressure measurement, both as a function of time. Deducing mechanical properties of the esophagus including wall material properties, contraction strength, and wall relaxation from these data is a challenging inverse problem. Knowing mechanical properties can change how clinical decisions are made because of its potential for in-vivo mechanistic insights. To obtain such information, we conducted a parametric study to identify peristaltic regimes by using a 1D model of peristaltic flow through an elastic tube closed on both ends and also applied it to interpret clinical data. The results gave insightful information about the effect of tube stiffness, fluid/bolus density and contraction strength on the resulting esophagus shape through quantitive representations of the peristaltic regimes. Our analysis also revealed the mechanics of the opening of the contraction area as a function of bolus flow resistance. Lastly, we concluded that peristaltic driven flow displays three modes of peristaltic geometries, but all physiologically relevant flows fall into two peristaltic regimes characterized by a tight contraction.
△ Less
Submitted 29 December, 2021;
originally announced December 2021.
-
Fluid-structure instability forecasts thoracic aortic aneurysm progression
Authors:
Tom Y. Zhao,
Ethan M. I. Johnson,
Guy Elisha,
Sourav Halder,
Ben C. Smith,
Bradley D. Allen,
Michael Markl,
Neelesh A. Patankar
Abstract:
The basic mechanism driving aneurysm growth is unknown. Currently, clinical diagnosis of an aneurysm is mainly informed by retrospective tracking of its size and growth rate. However, aneurysms can rupture before reactive criteria are met or remain stable when they are exceeded. Here, we identify a fluid-structure instability that is associated with abnormal aortic dilatation. Our analysis yields…
▽ More
The basic mechanism driving aneurysm growth is unknown. Currently, clinical diagnosis of an aneurysm is mainly informed by retrospective tracking of its size and growth rate. However, aneurysms can rupture before reactive criteria are met or remain stable when they are exceeded. Here, we identify a fluid-structure instability that is associated with abnormal aortic dilatation. Our analysis yields a measurable dimensionless number and its analytically derived critical threshold. This threshold pinpoints the transition from stable flow to unstable aortic fluttering as a function of the physiological properties composing the dimensionless number, like blood pressure and aortic compliance. A retrospective study was then conducted with 4D-flow MRI data from 117 patients indicated for cardiac imaging and 100 healthy volunteers recruited prospectively. The difference between the dimensionless number and its critical threshold was calculated for every subject from their earliest MRI data and used as an aneurysm physiomarker to forecast future growth. As a binary predictor for abnormal growth and subsequent surgical intervention reported from follow-up imaging, the aneurysm physiomarker yielded an AUC of 0.997 in a receiving operator characteristic analysis. Though validated here for thoracic ascending aortic aneurysms, this instability mechanism may be used to understand, predict and inform patient-specific treatment of aneurysms in any location without fundamental differences.
△ Less
Submitted 7 August, 2023; v1 submitted 18 November, 2021;
originally announced November 2021.
-
Esophageal virtual disease landscape using mechanics-informed machine learning
Authors:
Sourav Halder,
Jun Yamasaki,
Shashank Acharya,
Wenjun Kou,
Guy Elisha,
Dustin A. Carlson,
Peter J. Kahrilas,
John E. Pandolfino,
Neelesh A. Patankar
Abstract:
The pathogenesis of esophageal disorders is related to the esophageal wall mechanics. Therefore, to understand the underlying fundamental mechanisms behind various esophageal disorders, it is crucial to map the esophageal wall mechanics-based parameters onto physiological and pathophysiological conditions corresponding to altered bolus transit and supraphysiologic IBP. In this work, we present a h…
▽ More
The pathogenesis of esophageal disorders is related to the esophageal wall mechanics. Therefore, to understand the underlying fundamental mechanisms behind various esophageal disorders, it is crucial to map the esophageal wall mechanics-based parameters onto physiological and pathophysiological conditions corresponding to altered bolus transit and supraphysiologic IBP. In this work, we present a hybrid framework that combines fluid mechanics and machine learning to identify the underlying physics of the various esophageal disorders and maps them onto a parameter space which we call the virtual disease landscape (VDL). A one-dimensional inverse model processes the output from an esophageal diagnostic device called endoscopic functional lumen imaging probe (EndoFLIP) to estimate the mechanical "health" of the esophagus by predicting a set of mechanics-based parameters such as esophageal wall stiffness, muscle contraction pattern and active relaxation of esophageal walls. The mechanics-based parameters were then used to train a neural network that consists of a variational autoencoder (VAE) that generates a latent space and a side network that predicts mechanical work metrics for estimating esophagogastric junction motility. The latent vectors along with a set of discrete mechanics-based parameters define the VDL and form clusters corresponding to the various esophageal disorders. The VDL not only distinguishes different disorders but can also be used to predict disease progression in time. Finally, we also demonstrate the clinical applicability of this framework for estimating the effectiveness of a treatment and track patient condition after a treatment.
△ Less
Submitted 18 November, 2021;
originally announced November 2021.