-
A highly stable and fully tunable open microcavity platform at cryogenic temperatures
Authors:
Maximilian Pallmann,
Timon Eichhorn,
Julia Benedikter,
Bernardo Casabone,
Thomas Hümmer,
David Hunger
Abstract:
Open-access microcavities are a powerful tool to enhance light-matter interactions for solid-state quantum and nano systems and are key to advance applications in quantum technologies. For this purpose, the cavities should simultaneously meet two conflicting requirements - full tunability to cope with spatial and spectral inhomogeneities of a material, and highest stability under operation in a cr…
▽ More
Open-access microcavities are a powerful tool to enhance light-matter interactions for solid-state quantum and nano systems and are key to advance applications in quantum technologies. For this purpose, the cavities should simultaneously meet two conflicting requirements - full tunability to cope with spatial and spectral inhomogeneities of a material, and highest stability under operation in a cryogenic environment to maintain resonance conditions. To tackle this challenge, we have developed a fully-tunable, open-access, fiber-based Fabry-Pérot microcavity platform which can be operated also under increased noise levels in a closed-cycle cryostat. It comprises custom-designed monolithic micro- and nanopositioning elements with up to mm-scale travel range that achieve a passive cavity length stability at low temperature of only 15 pm rms in a closed-cycle cryostat, and 5 pm in a more quiet flow cryostat. This can be further improved by active stabilization, and even higher stability is obtained under direct mechanical contact between the cavity mirrors, yielding 0:8 pm rms during the quiet phase of the closed-cycle cryo cooler. The platform provides operation of cryogenic cavities with high finesse and small mode volume for strong enhancement of light-matter interactions, opening up novel possibilities for experiments with a great variety of quantum and nano materials.
△ Less
Submitted 22 December, 2022;
originally announced December 2022.
-
Hyperpolarized solution-state NMR spectroscopy with optically polarized crystals
Authors:
Tim R. Eichhorn,
Anna J. Parker,
Felix Josten,
Christoph Müller,
Jochen Scheuer,
Jakob M. Steiner,
Martin Gierse,
Jonas Handwerker,
Michael Keim,
Sebastian Lucas,
Mohammad Usman Qureshi,
Alastair Marshall,
Alon Salhov,
Yifan Quan,
Jan Binder,
Kay Jahnke,
Philipp Neumann,
Stephan Knecht,
John W. Blanchard,
Martin B. Plenio,
Fedor Jelezko,
Lyndon Emsley,
Christophoros C. Vassiliou,
Patrick Hautle,
Ilai Schwartz
Abstract:
Nuclear spin hyperpolarization provides a promising route to overcome the challenges imposed by the limited sensitivity of nuclear magnetic resonance. Here we demonstrate that dissolution of spin-polarized pentacene-doped naphthalene crystals enables transfer of polarization to target molecules via intermolecular cross relaxation at room temperature and moderate magnetic fields (1.45$\,$T). This m…
▽ More
Nuclear spin hyperpolarization provides a promising route to overcome the challenges imposed by the limited sensitivity of nuclear magnetic resonance. Here we demonstrate that dissolution of spin-polarized pentacene-doped naphthalene crystals enables transfer of polarization to target molecules via intermolecular cross relaxation at room temperature and moderate magnetic fields (1.45$\,$T). This makes it possible to exploit the high spin polarization of optically polarized crystals while mitigating the challenges of its transfer to external nuclei, particularly of the large distances and prohibitively weak coupling between source and target nuclei across solid-solid or solid-liquid interfaces. With this method, here we inject the highly polarized mixture into a benchtop NMR spectrometer and observe the polarization dynamics for target $^1$H nuclei. Although the spectra are radiation damped due to the high naphthalene magnetization, we describe a procedure to process the data in order to obtain more conventional NMR spectra, and extract the target nuclei polarization. With the entire process occurring on a timescale of one minute, we observe NMR signals enhanced by factors between -200 and -1730 at 1.45$\,$T for a range of small molecules.
△ Less
Submitted 17 August, 2021; v1 submitted 13 August, 2021;
originally announced August 2021.
-
EUTelescope: A modular reconstruction framework for beam telescope data
Authors:
Tobias Bisanz,
Hendrik Jansen,
Jan-Hendrik Arling,
Antonio Bulgheroni,
Jan Dreyling-Eschweiler,
Thomas Eichhorn,
Ingrid-Maria Gregor,
Phlillip Hamnett,
Claus Kleinwort,
Alexander Morton,
Hanno Perrey,
Michaela Queitsch-Maitland,
Edoardo Rossi,
Simon Spannagel
Abstract:
EUTelescope is a modular, comprehensive software framework for the reconstruction of particle trajectories recorded with beam telescopes. Its modularity allows for a flexible usage of processors each fulfilling separate tasks of the reconstruction chain such as clustering, alignment and track fitting. %The reconstruction chain is directed via XML steering files. The framework facilitates the usage…
▽ More
EUTelescope is a modular, comprehensive software framework for the reconstruction of particle trajectories recorded with beam telescopes. Its modularity allows for a flexible usage of processors each fulfilling separate tasks of the reconstruction chain such as clustering, alignment and track fitting. %The reconstruction chain is directed via XML steering files. The framework facilitates the usage of any position sensitive device for both the beam telescope sensors as well as the device under test and supports a wide range of geometric arrangements of the sensors.
In this work, the functionality of the EUTelescope framework as released in v2.2 and its underlying dependencies are discussed. Various use cases with emphasis on the General Broken Lines advanced track fitting methods give examples of the work flow and capabilities of the framework.
△ Less
Submitted 20 November, 2020;
originally announced November 2020.
-
EUDAQ $-$ A Data Acquisition Software Framework for Common Beam Telescopes
Authors:
P. Ahlburg,
S. Arfaoui,
J. -H. Arling,
H. Augustin,
D. Barney,
M. Benoit,
T. Bisanz,
E. Corrin,
D. Cussans,
D. Dannheim,
J. Dreyling-Eschweiler,
T. Eichhorn,
A. Fiergolski,
I. -M. Gregor,
J. Grosse-Knetter,
D. Haas,
L. Huth,
A. Irles,
H. Jansen,
J. Janssen,
M. Keil,
J. S. Keller,
M. Kiehn,
H. J. Kim,
J. Kroll
, et al. (32 additional authors not shown)
Abstract:
EUDAQ is a generic data acquisition software developed for use in conjunction with common beam telescopes at charged particle beam lines. Providing high-precision reference tracks for performance studies of new sensors, beam telescopes are essential for the research and development towards future detectors for high-energy physics. As beam time is a highly limited resource, EUDAQ has been designed…
▽ More
EUDAQ is a generic data acquisition software developed for use in conjunction with common beam telescopes at charged particle beam lines. Providing high-precision reference tracks for performance studies of new sensors, beam telescopes are essential for the research and development towards future detectors for high-energy physics. As beam time is a highly limited resource, EUDAQ has been designed with reliability and ease-of-use in mind. It enables flexible integration of different independent devices under test via their specific data acquisition systems into a top-level framework. EUDAQ controls all components globally, handles the data flow centrally and synchronises and records the data streams. Over the past decade, EUDAQ has been deployed as part of a wide range of successful test beam campaigns and detector development applications.
△ Less
Submitted 18 November, 2019; v1 submitted 30 September, 2019;
originally announced September 2019.
-
Summary and Conclusions of the 'JRA Beam Telescope 2025'-Forum at the 6th Beam Telescopes and Test Beams Workshop
Authors:
J. Dreyling-Eschweiler,
H. Jansen,
M. S. Amjad,
J. -H. Arling,
T. Coates,
A. Dätwyler,
D. Dannheim,
M. W. U. van Dijk,
T. Eichhorn,
A. Gerbershagen,
O. Girard,
B. Gkotse,
F. J. Iguaz,
J. Kroll,
C. Nellist,
F. Ravotti,
E. Rossi,
A. Rummler,
F. Salvatore,
S. Spannagel,
M. Weers,
J. Weingarten
Abstract:
On January 17th 2018, a forum on a possible Joint Research Activity on a future common Beam Telescope was held during the 6th Beam Telescopes and Test Beams Workshop (BTTB) in Zurich, Switzerland. The BTTB workshop aims at bringing together the community involved in beam tests. It therefore offers a suitable platform to induce community-wide discussions. The forum and its discussions were well rec…
▽ More
On January 17th 2018, a forum on a possible Joint Research Activity on a future common Beam Telescope was held during the 6th Beam Telescopes and Test Beams Workshop (BTTB) in Zurich, Switzerland. The BTTB workshop aims at bringing together the community involved in beam tests. It therefore offers a suitable platform to induce community-wide discussions. The forum and its discussions were well received and the participants concluded that appropriate actions should be undertaken promptly. Specific hardware and software proposals were discussed, with an emphasis on improving current common EUDET-type telescopes based on Mimosa26 sensors towards higher trigger rate capabilities in convolution with considerably improved time resolution. EUDAQ as a common top level DAQ and its modular structure is ready for future hardware. EUTelescope fulfils many requirements of a common reconstruction framework, but has also various drawbacks. Thus, requirements for a new common reconstruction framework were collected. A new common beam telescope evolves with the sensor decision and the whole package including a reconstruction framework depends on that decision.
△ Less
Submitted 8 January, 2019; v1 submitted 24 May, 2018;
originally announced May 2018.
-
Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector
Authors:
M. Dragicevic,
M. Friedl,
J. Hrubec,
H. Steininger,
A. Gädda,
J. Härkönen,
T. Lampén,
P. Luukka,
T. Peltola,
E. Tuominen,
E. Tuovinen,
A. Winkler,
P. Eerola,
T. Tuuva,
G. Baulieu,
G. Boudoul,
L. Caponetto,
C. Combaret,
D. Contardo,
T. Dupasquier,
G. Gallbit,
N. Lumb,
L. Mirabito,
S. Perries,
M. Vander Donckt
, et al. (462 additional authors not shown)
Abstract:
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator…
▽ More
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,μ\mathrm{m}$ and $7.99\pm0.21\,μ\mathrm{m}$ along the $100\,μ\mathrm{m}$ and $150\,μ\mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.
△ Less
Submitted 1 June, 2017;
originally announced June 2017.
-
Enabling Technologies for Silicon Microstrip Tracking Detectors at the HL-LHC
Authors:
C. Barth,
C. A. Betancourt,
I. Bloch,
F. Bögelspacher,
W. de Boer,
M. Daniels,
A. Dierlamm,
R. Eber,
G. Eckerlin,
D. Eckstein,
T. Eichhorn,
J. Erfle,
L. Feld,
E. Garutti,
I. -M. Gregor,
M. Guthoff,
F. Hartmann,
M. Hauser,
U. Husemann,
K. Jakobs,
A. Junkes,
W. Karpinski,
K. Klein,
S. Kuehn,
H. Lacker
, et al. (16 additional authors not shown)
Abstract:
While the tracking detectors of the ATLAS and CMS experiments have shown excellent performance in Run 1 of LHC data taking, and are expected to continue to do so during LHC operation at design luminosity, both experiments will have to exchange their tracking systems when the LHC is upgraded to the high-luminosity LHC (HL-LHC) around the year 2024. The new tracking systems need to operate in an env…
▽ More
While the tracking detectors of the ATLAS and CMS experiments have shown excellent performance in Run 1 of LHC data taking, and are expected to continue to do so during LHC operation at design luminosity, both experiments will have to exchange their tracking systems when the LHC is upgraded to the high-luminosity LHC (HL-LHC) around the year 2024. The new tracking systems need to operate in an environment in which both the hit densities and the radiation damage will be about an order of magnitude higher than today. In addition, the new trackers need to contribute to the first level trigger in order to maintain a high data-taking efficiency for the interesting processes. Novel detector technologies have to be developed to meet these very challenging goals. The German groups active in the upgrades of the ATLAS and CMS tracking systems have formed a collaborative "Project on Enabling Technologies for Silicon Microstrip Tracking Detectors at the HL-LHC" (PETTL), which was supported by the Helmholtz Alliance "Physics at the Terascale" during the years 2013 and 2014. The aim of the project was to share experience and to work together on key areas of mutual interest during the R&D phase of these upgrades. The project concentrated on five areas, namely exchange of experience, radiation hardness of silicon sensors, low mass system design, automated precision assembly procedures, and irradiations. This report summarizes the main achievements.
△ Less
Submitted 28 April, 2016;
originally announced April 2016.
-
Performance of the EUDET-type beam telescopes
Authors:
H. Jansen,
S. Spannagel,
J. Behr,
A. Bulgheroni,
G. Claus,
E. Corrin,
D. G. Cussans,
J. Dreyling-Eschweiler,
D. Eckstein,
T. Eichhorn,
M. Goffe,
I. M. Gregor,
D. Haas,
C. Muhl,
H. Perrey,
R. Peschke,
P. Roloff,
I. Rubinskiy,
M. Winter
Abstract:
Test beam measurements at the test beam facilities of DESY have been conducted to characterise the performance of the EUDET-type beam telescopes originally developed within the EUDET project. The beam telescopes are equipped with six sensor planes using MIMOSA26 monolithic active pixel devices. A programmable Trigger Logic Unit provides trigger logic and time stamp information on particle passage.…
▽ More
Test beam measurements at the test beam facilities of DESY have been conducted to characterise the performance of the EUDET-type beam telescopes originally developed within the EUDET project. The beam telescopes are equipped with six sensor planes using MIMOSA26 monolithic active pixel devices. A programmable Trigger Logic Unit provides trigger logic and time stamp information on particle passage. Both data acquisition framework and offline reconstruction software packages are available. User devices are easily integrable into the data acquisition framework via predefined interfaces.
The biased residual distribution is studied as a function of the beam energy, plane spacing and sensor threshold. Its standard deviation at the two centre pixel planes using all six planes for tracking in a 6\,GeV electron/positron-beam is measured to be $(2.88\,\pm\,0.08)\,\upmu\meter$.Iterative track fits using the formalism of General Broken Lines are performed to estimate the intrinsic resolution of the individual pixel planes. The mean intrinsic resolution over the six sensors used is found to be $(3.24\,\pm\,0.09)\,\upmu\meter$.With a 5\,GeV electron/positron beam, the track resolution halfway between the two inner pixel planes using an equidistant plane spacing of 20\,mm is estimated to $(1.83\,\pm\,0.03)\,\upmu\meter$ assuming the measured intrinsic resolution. Towards lower beam energies the track resolution deteriorates due to increasing multiple scattering. Threshold studies show an optimal working point of the MIMOSA26 sensors at a sensor threshold of between five and six times their RMS noise. Measurements at different plane spacings are used to calibrate the amount of multiple scattering in the material traversed and allow for corrections to the predicted angular scattering for electron beams.
△ Less
Submitted 10 May, 2016; v1 submitted 31 March, 2016;
originally announced March 2016.
-
Trap** in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker
Authors:
W. Adam,
T. Bergauer,
M. Dragicevic,
M. Friedl,
R. Fruehwirth,
M. Hoch,
J. Hrubec,
M. Krammer,
W. Treberspurg,
W. Waltenberger,
S. Alderweireldt,
W. Beaumont,
X. Janssen,
S. Luyckx,
P. Van Mechelen,
N. Van Remortel,
A. Van Spilbeeck,
P. Barria,
C. Caillol,
B. Clerbaux,
G. De Lentdecker,
D. Dobur,
L. Favart,
A. Grebenyuk,
Th. Lenzi
, et al. (663 additional authors not shown)
Abstract:
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determi…
▽ More
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trap** rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trap** rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. The effective trap** rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations.
△ Less
Submitted 7 May, 2015;
originally announced May 2015.
-
A Method to Simulate the Observed Surface Properties of Proton Irradiated Silicon Strip Sensors
Authors:
Timo Peltola,
Ashutosh Bhardwaj,
Ranjeet Dalal,
Robert Eber,
Thomas Eichhorn,
Kavita Lalwani,
Alberto Messineo,
Martin Printz,
Kirti Ranjan
Abstract:
During the scheduled high luminosity upgrade of LHC, the world's largest particle physics accelerator at CERN, the position sensitive silicon detectors installed in the vertex and tracking part of the CMS experiment will face more intense radiation environment than the present system was designed for. To upgrade the tracker to required performance level, extensive measurements and simulations stud…
▽ More
During the scheduled high luminosity upgrade of LHC, the world's largest particle physics accelerator at CERN, the position sensitive silicon detectors installed in the vertex and tracking part of the CMS experiment will face more intense radiation environment than the present system was designed for. To upgrade the tracker to required performance level, extensive measurements and simulations studies have already been carried out. A defect model of Synopsys Sentaurus TCAD simulation package for the bulk properties of proton irradiated devices has been producing simulations closely matching with measurements of silicon strip detectors. However, the model does not provide expected behavior due to the fluence increased surface damage. The solution requires an approach that does not affect the accurate bulk properties produced by the proton model, but only adds to it the required radiation induced properties close to the surface. These include the observed position dependency of the strip detector's charge collection efficiency (CCE). In this paper a procedure to find a defect model that reproduces the correct CCE loss, along with other surface properties of a strip detector up to a fluence $1.5\times10^{15}$ 1 MeV n$_{\textrm{eq}}$ cm$^{-2}$, will be presented. When applied with CCE loss measurements at different fluences, this method may provide means for the parametrization of the accumulation of oxide charge at the SiO2/Si interface as a function of dose.
△ Less
Submitted 10 March, 2015; v1 submitted 24 September, 2014;
originally announced September 2014.