-
A Segmented, Enriched N-type Germanium Detector for Neutrinoless Double Beta-Decay Experiments
Authors:
L. E. Leviner,
C. E. Aalseth,
M. W. Ahmed,
F. T. Avignone III,
H. O. Back,
A. S. Barabash,
M. Boswell,
L. De Braeckeleer,
V. B. Brudanin,
Y-D Chan,
V. G. Egorov,
S. R. Elliott,
V. M. Gehman,
T. W. Hossbach,
J. D. Kephart,
M. F. Kidd,
S. I. Konovalov,
K. T. Lesko,
**gyi Li,
D-M Mei,
S. Mikhailov,
H. Miley,
D. C. Radford,
J. Reeves,
V. G. Sandukovsky
, et al. (5 additional authors not shown)
Abstract:
We present data characterizing the performance of the first segmented, N-type Ge detector, isotopically enriched to 85% $^{76}$Ge. This detector, based on the Ortec PT6x2 design and referred to as SEGA (Segmented, Enriched Germanium Assembly), was developed as a possible prototype for neutrinoless double beta-decay measurements by the {\sc Majorana} collaboration. We present some of the general ch…
▽ More
We present data characterizing the performance of the first segmented, N-type Ge detector, isotopically enriched to 85% $^{76}$Ge. This detector, based on the Ortec PT6x2 design and referred to as SEGA (Segmented, Enriched Germanium Assembly), was developed as a possible prototype for neutrinoless double beta-decay measurements by the {\sc Majorana} collaboration. We present some of the general characteristics (including bias potential, efficiency, leakage current, and integral cross-talk) for this detector in its temporary cryostat. We also present an analysis of the resolution of the detector, and demonstrate that for all but two segments there is at least one channel that reaches the {\sc Majorana} resolution goal below 4 keV FWHM at 2039 keV, and all channels are below 4.5 keV FWHM.
△ Less
Submitted 19 April, 2013;
originally announced April 2013.
-
Results of the BiPo-1 prototype for radiopurity measurements for the SuperNEMO double beta decay source foils
Authors:
J. Argyriades,
R. Arnold,
C. Augier,
J. Baker,
A. S. Barabash,
A. Basharina-Freshville,
M. Bongrand,
C. Bourgeois,
D. Breton,
M. Briére,
G. Broudin-Bay,
V. B. Brudanin,
A. J. Caffrey,
S. Cebrián,
A. Chapon,
E. Chauveau,
Th. Dafni,
J. Díaz,
D. Durand,
V. G. Egorov,
J. J. Evans,
R. Flack,
K-I. Fushima,
I. G. Irastorza,
X. Garrido
, et al. (64 additional authors not shown)
Abstract:
The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in $^{208}$Tl and $^{214}$Bi for the SuperNEMO double beta decay source foils. A modular prototype, called BiPo-1, with 0.8 $m^2$ of sensitive surface area, has been running in the Modane Underground Laboratory since February, 2008. The goal of BiPo-1 is to measure the different components of the backg…
▽ More
The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in $^{208}$Tl and $^{214}$Bi for the SuperNEMO double beta decay source foils. A modular prototype, called BiPo-1, with 0.8 $m^2$ of sensitive surface area, has been running in the Modane Underground Laboratory since February, 2008. The goal of BiPo-1 is to measure the different components of the background and in particular the surface radiopurity of the plastic scintillators that make up the detector. The first phase of data collection has been dedicated to the measurement of the radiopurity in $^{208}$Tl. After more than one year of background measurement, a surface activity of the scintillators of $\mathcal{A}$($^{208}$Tl) $=$ 1.5 $μ$Bq/m$^2$ is reported here. Given this level of background, a larger BiPo detector having 12 m$^2$ of active surface area, is able to qualify the radiopurity of the SuperNEMO selenium double beta decay foils with the required sensitivity of $\mathcal{A}$($^{208}$Tl) $<$ 2 $μ$Bq/kg (90% C.L.) with a six month measurement.
△ Less
Submitted 3 May, 2010;
originally announced May 2010.
-
Spectral modeling of scintillator for the NEMO-3 and SuperNEMO detectors
Authors:
J. Argyriades,
R. Arnold,
C. Augier,
J. Baker,
A. S. Barabash,
M. Bongrand,
G. Broudin-Bay,
V. B. Brudanin,
A. J. Caffrey,
S. Cebrián,
A. Chapon,
E. Chauveau,
Th. Dafni,
Z. Daraktchieva,
J. D iaz,
D. Durand,
V. G. Egorov,
J. J. Evans,
N. Fatemi-Ghomi,
R. Flack,
A. Basharina-Freshville,
K-I. Fushimi,
X. Garrido,
H. Gómez,
B. Guillon
, et al. (68 additional authors not shown)
Abstract:
We have constructed a GEANT4-based detailed software model of photon transport in plastic scintillator blocks and have used it to study the NEMO-3 and SuperNEMO calorimeters employed in experiments designed to search for neutrinoless double beta decay. We compare our simulations to measurements using conversion electrons from a calibration source of $\rm ^{207}Bi$ and show that the agreement is im…
▽ More
We have constructed a GEANT4-based detailed software model of photon transport in plastic scintillator blocks and have used it to study the NEMO-3 and SuperNEMO calorimeters employed in experiments designed to search for neutrinoless double beta decay. We compare our simulations to measurements using conversion electrons from a calibration source of $\rm ^{207}Bi$ and show that the agreement is improved if wavelength-dependent properties of the calorimeter are taken into account. In this article, we briefly describe our modeling approach and results of our studies.
△ Less
Submitted 8 November, 2010; v1 submitted 21 April, 2010;
originally announced April 2010.