-
CCAT: Detector Noise Limited Performance of the RFSoC-based Readout Electronics for mm/sub-mm/far-IR KIDs
Authors:
Adrian K. Sinclair,
James Burgoyne,
Anthony I. Huber,
Colin Murphy,
Steve K. Choi,
Cody J. Duell,
Zachary B. Huber,
Yaqiong Li,
Scott C. Chapman,
Michael D. Niemack,
Thomas Nikola,
Eve M. Vavagiakis,
Samantha Walker,
Jordan D. Wheeler,
Jason Austermann,
Lawrence Lin,
Ruixuan Xie,
Bugao Zou,
Philip D. Mauskopf
Abstract:
The Fred Young Submillimeter Telescope (FYST), on Cerro Chajnantor in the Atacama desert of Chile, will conduct wide-field and small deep-field surveys of the sky with more than 100,000 detectors on the Prime-Cam instrument. Kinetic inductance detectors (KIDs) were chosen as the primary sensor technology for their high density focal plane packing. Additionally, they benefit from low cost, ease of…
▽ More
The Fred Young Submillimeter Telescope (FYST), on Cerro Chajnantor in the Atacama desert of Chile, will conduct wide-field and small deep-field surveys of the sky with more than 100,000 detectors on the Prime-Cam instrument. Kinetic inductance detectors (KIDs) were chosen as the primary sensor technology for their high density focal plane packing. Additionally, they benefit from low cost, ease of fabrication, and simplified cryogenic readout, which are all beneficial for successful deployment at scale. The cryogenic multiplexing complexity is pulled out of the cryostat and is instead pushed into the digital signal processing of the room temperature electronics. Using the Xilinx Radio Frequency System on a Chip (RFSoC), a highly multiplexed KID readout was developed for the first light Prime-Cam and commissioning Mod-Cam instruments. We report on the performance of the RFSoC-based readout with multiple detector arrays in various cryogenic setups. Specifically we demonstrate detector noise limited performance of the RFSoC-based readout under the expected optical loading conditions.
△ Less
Submitted 21 June, 2024;
originally announced June 2024.
-
CCAT-prime: The 850 GHz camera for Prime-Cam on FYST
Authors:
Scott C. Chapman,
Anthony I. Huber,
Adrian K. Sinclair,
Jordan D. Wheeler,
Jason E. Austermann,
James Beall,
James Burgoyne,
Steve K. Choi,
Abigail Crites,
Cody J. Duell,
Jesslyn Devina,
Jiansong Gao,
Mike Fich,
Doug Henke,
Terry Herter,
Doug Johnstone,
Lewis B. G. Knee,
Michael D. Niemack,
Kayla M. Rossi,
Gordon Stacey,
Joel Tsuchitori,
Joel Ullom,
Jeff Van Lanen,
Eve M. Vavagiakis,
Michael Vissers
, et al. (1 additional authors not shown)
Abstract:
The Fred Young Submillimeter Telescope (FYST) at the Cerro-Chajnantor Atacama Telescope prime (CCAT- prime) Facility will host Prime-Cam as a powerful, first generation camera with imaging polarimeters working at several wavelengths and spectroscopic instruments aimed at intensity map** during the Epoch of Reionization. Here we introduce the 850 GHz (350 micron) instrument module. This will be t…
▽ More
The Fred Young Submillimeter Telescope (FYST) at the Cerro-Chajnantor Atacama Telescope prime (CCAT- prime) Facility will host Prime-Cam as a powerful, first generation camera with imaging polarimeters working at several wavelengths and spectroscopic instruments aimed at intensity map** during the Epoch of Reionization. Here we introduce the 850 GHz (350 micron) instrument module. This will be the highest frequency module in Prime-Cam and the most novel for astronomical and cosmological surveys, taking full advantage of the atmospheric transparency at the high 5600 meter CCAT-prime siting on Cerro Chajnantor. With a 1.1 deg diameter field, the 850 GHz module will deploy ~40,000 Kinetic Inductance Detectors (KIDs) with Silicon platelet feedhorn coupling (both fabricated at NIST), and will provide unprecedented broadband intensity and polarization measurement capabilities. The 850 GHz module will be key to addressing pressing astrophysical questions regarding galaxy formation, Big Bang cosmology, and star formation within our own Galaxy. We present the motivation and overall design for the module, and initial laboratory characterization.
△ Less
Submitted 22 August, 2022;
originally announced August 2022.
-
CCAT-prime: RFSoC Based Readout for Frequency Multiplexed Kinetic Inductance Detectors
Authors:
Adrian K. Sinclair,
Ryan C. Stephenson,
Cody A. Roberson,
Eric L. Weeks,
James Burgoyne,
Anthony I. Huber,
Philip M. Mauskopf,
Scott C. Chapman,
Jason E. Austermann,
Steve K. Choi,
Cody J. Duell,
Michel Fich,
Christopher E. Groppi,
Zachary Huber,
Michael D. Niemack,
Thomas Nikola,
Kayla M. Rossi,
Adhitya Sriram,
Gordon J. Stacey,
Erik Szakiel,
Joel Tsuchitori,
Eve M. Vavagiakis,
Jordan D. Wheeler,
the CCAT-prime collaboration
Abstract:
The Prime-Cam instrument on the Fred Young Submillimeter Telescope (FYST) is expected to be the largest deployment of millimeter and submillimeter sensitive kinetic inductance detectors to date. To read out these arrays efficiently, a microwave frequency multiplexed readout has been designed to run on the Xilinx Radio Frequency System on a Chip (RFSoC). The RFSoC has dramatically improved every ca…
▽ More
The Prime-Cam instrument on the Fred Young Submillimeter Telescope (FYST) is expected to be the largest deployment of millimeter and submillimeter sensitive kinetic inductance detectors to date. To read out these arrays efficiently, a microwave frequency multiplexed readout has been designed to run on the Xilinx Radio Frequency System on a Chip (RFSoC). The RFSoC has dramatically improved every category of size, weight, power, cost, and bandwidth over the previous generation readout systems. We describe a baseline firmware design which can read out four independent RF networks each with 500 MHz of bandwidth and 1000 detectors for ~30 W. The overall readout architecture is a combination of hardware, gateware/firmware, software, and network design. The requirements of the readout are driven by the 850 GHz instrument module of the 7-module Prime-Cam instrument. These requirements along with other constraints which have led to critical design choices are highlighted. Preliminary measurements of the system phase noise and dynamic range are presented.
△ Less
Submitted 15 August, 2022;
originally announced August 2022.
-
The Simons Observatory: Magnetic Shielding Measurements for the Universal Multiplexing Module
Authors:
Zachary B. Huber,
Yaqiong Li,
Eve M. Vavagiakis,
Steve K. Choi,
Jake Connors,
Nicholas F. Cothard,
Cody J. Duell,
Nicholas Galitzki,
Erin Healy,
Johannes Hubmayr,
Bradley R. Johnson,
Benjamin Keller,
Heather McCarrick,
Michael D. Niemack,
Yuhan Wang,
Zhilei Xu,
Kaiwen Zheng
Abstract:
The Simons Observatory (SO) includes four telescopes that will measure the temperature and polarization of the cosmic microwave background using over 60,000 highly sensitive transition-edge bolometers (TES). These multichroic TES bolometers are read out by a microwave RF SQUID multiplexing system with a multiplexing factor of 910. Given that both TESes and SQUIDs are susceptible to magnetic field…
▽ More
The Simons Observatory (SO) includes four telescopes that will measure the temperature and polarization of the cosmic microwave background using over 60,000 highly sensitive transition-edge bolometers (TES). These multichroic TES bolometers are read out by a microwave RF SQUID multiplexing system with a multiplexing factor of 910. Given that both TESes and SQUIDs are susceptible to magnetic field pickup and that it is hard to predict how they will respond to such fields, it is important to characterize the magnetic response of these systems empirically. This information can then be used to limit spurious signals by informing magnetic shielding designs for the detectors and readout. This paper focuses on measurements of magnetic pickup with different magnetic shielding configurations for the SO universal multiplexing module (UMM), which contains the SQUIDs, associated resonators, and TES bias circuit. The magnetic pickup of a prototype UMM was tested under three shielding configurations: no shielding (copper packaging), aluminum packaging for the UMM, and a tin/lead-plated shield surrounding the entire dilution refrigerator 100 mK cold stage. The measurements show that the aluminum packaging outperforms the copper packaging by a shielding factor of 8-10, and adding the tin/lead-plated 1K shield further increases the relative shielding factor in the aluminum configuration by 1-2 orders of magnitude.
△ Less
Submitted 1 March, 2023; v1 submitted 22 November, 2021;
originally announced November 2021.
-
Simons Observatory Microwave SQUID Multiplexing Readout -- Cryogenic RF Amplifier and Coaxial Chain Design
Authors:
Mayuri Sathyanarayana Rao,
Maximiliano Silva-Feaver,
Aamir Ali,
Kam Arnold,
Peter Ashton,
Bradley J. Dober,
Cody J. Duell,
Shannon M. Duff,
Nicholas Galitzki,
Erin Healy,
Shawn Henderson,
Shuay-Pwu Patty Ho,
Jonathan Hoh,
Anna M. Kofman,
Akito Kusaka,
Adrian T. Lee,
Aashrita Mangu,
Justin Mathewson,
Philip Mauskopf,
Heather McCarrick,
Jenna Moore,
Michael D. Niemack,
Christopher Raum,
Maria Salatino,
Trevor Sasse
, et al. (11 additional authors not shown)
Abstract:
The Simons Observatory (SO) is an upcoming polarization-sensitive Cosmic Microwave Background (CMB) experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of \bigO(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiple…
▽ More
The Simons Observatory (SO) is an upcoming polarization-sensitive Cosmic Microwave Background (CMB) experiment on the Cerro Toco Plateau (Chile) with large overlap with other optical and infrared surveys (e.g., DESI, LSST, HSC). To enable the readout of \bigO(10,000) detectors in each of the four telescopes of SO, we will employ the microwave SQUID multiplexing technology. With a targeted multiplexing factor of \bigO{(1,000)}, microwave SQUID multiplexing has never been deployed on the scale needed for SO. Here we present the design of the cryogenic coaxial cable and RF component chain that connects room temperature readout electronics to superconducting resonators that are coupled to Transition Edge Sensor bolometers operating at sub-Kelvin temperatures. We describe design considerations including cryogenic RF component selection, system linearity, noise, and thermal power dissipation.
△ Less
Submitted 19 March, 2020;
originally announced March 2020.