-
Correction of high-order phase variation effects in dynamic field monitoring
Authors:
Paul I. Dubovan,
Kyle M. Gilbert,
Corey A. Baron
Abstract:
Purpose: Field monitoring measures field perturbations, which can be accounted for during image reconstructions. In certain field monitoring environments, significant phase deviations can arise far from isocenter due to the finite extent of the gradient and/or main magnet. This can degrade the accuracy of field dynamics when field probes are placed near or outside the diameter spherical volume of…
▽ More
Purpose: Field monitoring measures field perturbations, which can be accounted for during image reconstructions. In certain field monitoring environments, significant phase deviations can arise far from isocenter due to the finite extent of the gradient and/or main magnet. This can degrade the accuracy of field dynamics when field probes are placed near or outside the diameter spherical volume of the gradient coils and/or main magnet, leading to corrupted image quality. The objective of this work was to develop a correction algorithm that reduces errors from highly nonlinear phase variations at distant field probes in field dynamic fits. Methods: The algorithm is split into three components. Component one fits phase coefficients one spatial order at a time, while the second implements a weighted least squares solution based on probe distance. After initial fitting, component three calculates phase residuals and removes the phase for distant probes before re-fitting. Two healthy volunteers were scanned on a head-only 7T MRI using diffusion-weighted single-shot spiral and EPI sequences and field monitoring was performed. Images were reconstructed with and without phase coefficient correction and compared qualitatively. Results: The algorithm was able to correct corrupted field dynamics, resulting in image quality improvements. Significant artefact reduction was observed when correcting higher order fits, especially for diffusion weighted images. Stepwise fitting provided the most correction benefit, which was marginally improved when adding weighted least squares and phase residual corrections. Conclusion: The proposed algorithm can mitigate effects of phase errors in field monitoring, providing improved reliability of field dynamic characterization.
△ Less
Submitted 23 January, 2023;
originally announced January 2023.
-
High-resolution single-shot spiral diffusion-weighted imaging at 7T using expanded encoding with compressed sensing
Authors:
Gabriel Varela-Mattatall,
Paul I. Dubovan,
Tales Santini,
Kyle M. Gilbert,
Ravi S. Menon,
Corey A. Baron
Abstract:
Purpose: The expanded encoding model incorporates spatially- and time-varying field perturbations for correction during reconstruction. So far, these reconstructions have used the conjugate gradient method with early stop** used as implicit regularization. However, this approach is likely suboptimal for low-SNR cases like diffusion or high-resolution MRI. Here, we investigate the extent that l1-…
▽ More
Purpose: The expanded encoding model incorporates spatially- and time-varying field perturbations for correction during reconstruction. So far, these reconstructions have used the conjugate gradient method with early stop** used as implicit regularization. However, this approach is likely suboptimal for low-SNR cases like diffusion or high-resolution MRI. Here, we investigate the extent that l1-wavelet regularization, or equivalently compressed sensing (CS), combined with expanded encoding improves trade-offs between spatial resolution, readout time and SNR for single-shot spiral diffusion-weighted imaging at 7T. The reconstructions were performed using our open-source GPU-enabled reconstruction toolbox, MatMRI, that allows inclusion of the different components of the expanded encoding model, with or without CS. Methods: In vivo accelerated single-shot spirals were acquired with five acceleration factors (2-6) and three in-plane spatial resolutions (1.5, 1.3, and 1.1 mm). From the in vivo reconstructions, we estimated diffusion tensors and computed fractional anisotropy maps. Then, simulations were used to quantitatively investigate and validate the impact of CS-based regularization on image quality when compared to a known ground truth. Results: In vivo reconstructions revealed improved image quality with retainment of small features when CS was used. Simulations showed that the joint use of the expanded encoding model and CS improves accuracy of image reconstructions (reduced mean-squared error) over the range of acceleration factors investigated. Conclusion: The expanded encoding model and CS regularization are complementary tools for single-shot spiral diffusion MRI, which enables both higher spatial resolutions and higher acceleration factors.
△ Less
Submitted 14 November, 2022;
originally announced November 2022.
-
Model-based determination of the synchronization delay between MRI and trajectory data
Authors:
Paul I. Dubovan,
Corey A. Baron
Abstract:
Purpose: Real time monitoring of dynamic magnetic fields has recently become a commercially available option for measuring MRI k-space trajectories and magnetic fields induced by eddy currents in real time. However, for accurate image reconstructions, sub-microsecond synchronization between the MRI and trajectory data is required. In this work, we introduce a new model-based algorithm to automatic…
▽ More
Purpose: Real time monitoring of dynamic magnetic fields has recently become a commercially available option for measuring MRI k-space trajectories and magnetic fields induced by eddy currents in real time. However, for accurate image reconstructions, sub-microsecond synchronization between the MRI and trajectory data is required. In this work, we introduce a new model-based algorithm to automatically perform this synchronization using only the MRI and trajectory data. Methods: The algorithm works by enforcing consistency between the MRI data, trajectory data, and receiver sensitivity profiles by iteratively alternating between convex optimizations for (a) the image and (b) the synchronization delay. A healthy human subject was scanned at 7T using a transmit-receive coil with integrated field probes using both single shot spiral and echo-planar imaging (EPI), and reconstructions with various synchronization delays were compared to the result of the proposed algorithm. The accuracy of the algorithm was also investigated using simulations, where the acquisition delays for simulated acquisitions were determined using the proposed algorithm and compared to the known ground truth. Results: In the in vivo scans, the proposed algorithm minimized artefacts related to synchronization delay for both spiral and EPI acquisitions, and the computation time required was less than 30 seconds. The simulations demonstrated accuracy to within tens of nanoseconds. Conclusion: The proposed algorithm can automatically determine synchronization delays between MRI data and trajectories measured using a field probe system.
△ Less
Submitted 27 May, 2022; v1 submitted 23 November, 2021;
originally announced November 2021.
-
Tuned bipolar oscillating gradients for map** frequency dispersion of diffusion kurtosis in the human brain
Authors:
Kevin B. Borsos,
Desmond H. Y. Tse,
Paul I. Dubovan,
Corey A. Baron
Abstract:
Purpose: Oscillating gradient spin echo (OGSE) sequences have demonstrated an ability to probe time-dependent microstructural features, though they often suffer from low SNR due to increased echo times. In this work we introduce frequency tuned bipolar (FTB) gradients as a variation of oscillating gradients with reduced echo time and demonstrate their utility by map** the frequency dispersion of…
▽ More
Purpose: Oscillating gradient spin echo (OGSE) sequences have demonstrated an ability to probe time-dependent microstructural features, though they often suffer from low SNR due to increased echo times. In this work we introduce frequency tuned bipolar (FTB) gradients as a variation of oscillating gradients with reduced echo time and demonstrate their utility by map** the frequency dispersion of diffusion kurtosis in human subjects. Methods: An FTB oscillating gradient waveform is presented that provides encoding of 1.5 net oscillation periods thereby reducing the echo time of the acquisition. Simulations were performed to determine an optimal protocol based on SNR of kurtosis frequency dispersion - defined as the difference in kurtosis between pulsed and oscillating gradient acquisitions. Healthy human subjects were scanned at 7T using pulsed gradient and an optimized 23 Hz FTB protocol, which featured a maximum b-value of 2500 s/mm2. In addition, to directly compare existing methods, measurements using traditional cosine OGSE were also acquired. Results: FTB oscillating gradients demonstrated equivalent frequency dependent diffusion measurements compared to cosine modulated OGSE while enabling a significant reduction in echo time. Optimization and in vivo results suggest FTB gradients provide increased SNR of kurtosis dispersion maps compared to traditional cosine OGSE. The optimized FTB gradient protocol demonstrated consistent reductions in apparent kurtosis values and increased diffusivity in generated frequency dispersion maps. Conclusion: This work presents an alternative to traditional cosine OGSE sequences enabling more time efficient acquisitions of frequency dependent diffusion quantities as demonstrated through in vivo kurtosis frequency dispersion maps.
△ Less
Submitted 15 October, 2022; v1 submitted 28 September, 2021;
originally announced September 2021.
-
Characterization and Correction of Time-Varying Eddy Currents for Diffusion MRI
Authors:
Jake J. Valsamis,
Paul I. Dubovan,
Corey A. Baron
Abstract:
Purpose: Diffusion MRI (dMRI) suffers from eddy currents induced by strong diffusion gradients, which introduce artefacts that can impair subsequent diffusion metric analysis. Existing retrospective correction techniques that correct for diffusion gradient induced eddy currents do not account for eddy current decay, which is generally effective for traditional Pulsed Gradient Spin Echo (PGSE) diff…
▽ More
Purpose: Diffusion MRI (dMRI) suffers from eddy currents induced by strong diffusion gradients, which introduce artefacts that can impair subsequent diffusion metric analysis. Existing retrospective correction techniques that correct for diffusion gradient induced eddy currents do not account for eddy current decay, which is generally effective for traditional Pulsed Gradient Spin Echo (PGSE) diffusion encoding. However, these techniques do not necessarily apply to advanced forms of dMRI that require substantial gradient slewing, such as Oscillating Gradient Spin Echo (OGSE).
Methods: An in-house algorithm (TVEDDY), that for the first time retrospectively models eddy current decay, was tested on PGSE and OGSE brain images acquired at 7T. Correction performance was compared to conventional correction methods by evaluating the mean-squared error (MSE) between diffusion-weighted images acquired with opposite polarity diffusion gradients. As a ground truth comparison, images were corrected using field dynamics up to third order in space measured using a field monitoring system.
Results: Time-varying eddy currents were observed for OGSE, which introduced blurring that was not reduced using the traditional approach but was diminished considerably with TVEDDY and model-based reconstruction. No MSE difference was observed between the conventional approach and TVEDDY for PGSE, but for OGSE TVEDDY resulted in significantly lower MSE than the conventional approach. The field-monitoring-informed model-based reconstruction had the lowest MSE for both PGSE and OGSE.
Conclusion: This work establishes that it is possible to estimate time-varying eddy currents from the diffusion data itself, which provides substantial image quality improvements for gradient-intensive dMRI acquisitions like OGSE.
△ Less
Submitted 14 July, 2021; v1 submitted 31 January, 2021;
originally announced February 2021.