-
Performance of the ATLAS Muon Drift-Tube Chambers at High Background Rates and in Magnetic Fields
Authors:
J. Dubbert,
S. Horvat,
F. Legger,
O. Kortner,
H. Kroha,
R. Richter,
Ch. Valderanis,
F. Rauscher,
A. Staude
Abstract:
The ATLAS muon spectrometer uses drift-tube chambers for precision tracking. The performance of these chambers in the presence of magnetic field and high radiation fluxes is studied in this article using test-beam data recorded in the Gamma Irradiation Facility at CERN. The measurements are compared to detailed predictions provided by the Garfield drift-chamber simulation programme.
The ATLAS muon spectrometer uses drift-tube chambers for precision tracking. The performance of these chambers in the presence of magnetic field and high radiation fluxes is studied in this article using test-beam data recorded in the Gamma Irradiation Facility at CERN. The measurements are compared to detailed predictions provided by the Garfield drift-chamber simulation programme.
△ Less
Submitted 6 April, 2016;
originally announced April 2016.
-
Performance of the ATLAS Precision Muon Chambers under LHC Operating Conditions
Authors:
M. Deile,
H. Dietl,
J. Dubbert,
S. Horvat,
O. Kortner,
H. Kroha,
A. Manz,
S. Mohrdieck,
F. Rauscher,
R. Richter,
A. Staude
Abstract:
For the muon spectrometer of the ATLAS detector at the large hadron collider (LHC), large drift chambers consisting of 6 to 8 layers of pressurized drift tubes are used for precision tracking covering an active area of 5000 m2 in the toroidal field of superconducting air core magnets. The chambers have to provide a spatial resolution of 41 microns with Ar:CO2 (93:7) gas mixture at an absolute pres…
▽ More
For the muon spectrometer of the ATLAS detector at the large hadron collider (LHC), large drift chambers consisting of 6 to 8 layers of pressurized drift tubes are used for precision tracking covering an active area of 5000 m2 in the toroidal field of superconducting air core magnets. The chambers have to provide a spatial resolution of 41 microns with Ar:CO2 (93:7) gas mixture at an absolute pressure of 3 bar and gas gain of 2?104. The environment in which the chambers will be operated is characterized by high neutron and background with counting rates of up to 100 per square cm and second. The resolution and efficiency of a chamber from the serial production for ATLAS has been investigated in a 100 GeV muon beam at photon irradiation rates as expected during LHC operation. A silicon strip detector telescope was used as external reference in the beam. The spatial resolution of a chamber is degraded by 4 ?m at the highest background rate. The detection efficiency of the drift tubes is unchanged under irradiation. A tracking efficiency of 98% at the highest rates has been demonstrated.
△ Less
Submitted 1 April, 2016;
originally announced April 2016.
-
Resolution and Efficiency of the ATLAS Muon Drift-Tube Chambers at High Background Rates
Authors:
M. Deile,
J. Dubbert,
S. Horvat,
O. Kortner,
H. Kroha,
A. Manz,
S. Mohrdieck-Moeck,
F. Rauscher,
R. Richter,
A. Staude,
W. Stiller
Abstract:
The resolution and efficiency of a precision drift-tube chamber for the ATLAS muon spectrometer with final read-out electronics was tested at the Gamma Irradiation Facility at CERN in a 100 GeV muon beam and at photon irradiation rates of up to 990 Hz/square cm which corresponds to twice the highest background rate expected in ATLAS. A silicon strip detector telescope was used as external referenc…
▽ More
The resolution and efficiency of a precision drift-tube chamber for the ATLAS muon spectrometer with final read-out electronics was tested at the Gamma Irradiation Facility at CERN in a 100 GeV muon beam and at photon irradiation rates of up to 990 Hz/square cm which corresponds to twice the highest background rate expected in ATLAS. A silicon strip detector telescope was used as external reference in the beam. The pulse-height measurement of the read-out electronics was used to perform time-slewing corrections which lead to an improvement of the average drift-tube resolution from 104 microns to 82 microns without irradiation and from 128 microns to 108 microns at the maximum expected rate. The measured drift-tube efficiency agrees with the expectation from the dead time of the read-out electronics up to the maximum expected rate.
△ Less
Submitted 31 March, 2016;
originally announced March 2016.
-
Development of Fast High-Resolution Muon Drift-Tube Detectors for High Counting Rates
Authors:
B. Bittner,
J. Dubbert,
S. Horvat,
O. Kortner,
H. Kroha,
F. Legger,
R. Richter,
S. Adomeit,
O. Biebel,
A. Engl,
R. Hertenberger,
F. Rauscher,
A. Zibell
Abstract:
Pressurized drift-tube chambers are efficient detectors for high-precision tracking over large areas. The Monitored Drift-Tube (MDT) chambers of the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) reach a spatial resolution of 35 micons and almost 100% tracking efficiency with 6 layers of 30 mm diameter drift tubes operated with Ar:CO2 (93:7) gas mixture at 3 bar and a g…
▽ More
Pressurized drift-tube chambers are efficient detectors for high-precision tracking over large areas. The Monitored Drift-Tube (MDT) chambers of the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) reach a spatial resolution of 35 micons and almost 100% tracking efficiency with 6 layers of 30 mm diameter drift tubes operated with Ar:CO2 (93:7) gas mixture at 3 bar and a gas gain of 20000. The ATLAS MDT chambers are designed to cope with background counting rates due to neutrons and gamma-rays of up to about 300 kHz per tube which will be exceeded for LHC luminosities larger than the design value of 10-34 per square cm and second. Decreasing the drift-tube diameter to 15 mm while kee** the other parameters, including the gas gain, unchanged reduces the maximum drift time from about 700 ns to 200 ns and the drift-tube occupancy by a factor of 7. New drift-tube chambers for the endcap regions of the ATLAS muon spectrometer have been designed. A prototype chamber consisting of 12 times 8 layers of 15 mm diameter drift tubes of 1 m length has been constructed with a sense wire positioning accuracy of 20 microns. The 15 mm diameter drift-tubes have been tested with cosmic rays in the Gamma Irradiation Facility at CERN at counting rates of up to 1.85 MHz.
△ Less
Submitted 31 March, 2016;
originally announced March 2016.
-
Performance of Drift-Tube Detectors at High Counting Rates for High-Luminosity LHC Upgrades
Authors:
Bernhard Bittner,
Joerg Dubbert,
Oliver Kortner,
Hubert Kroha,
Alessandro Manfredini,
Sebastian Nowak,
Sebastian Ott,
Robert Richter,
Philipp Schwegler,
Daniele Zanzi,
Otmar Biebel,
Ralf Hertenberger,
Alexander Ruschke,
Andre Zibell
Abstract:
The performance of pressurized drift-tube detectors at very high background rates has been studied at the Gamma Irradiation Facility (GIF) at CERN and in an intense 20 MeV proton beam at the Munich Van-der-Graaf tandem accelerator for applications in large-area precision muon tracking at high-luminosity upgrades of the Large Hadron Collider (LHC). The ATLAS muon drifttube (MDT) chambers with 30 mm…
▽ More
The performance of pressurized drift-tube detectors at very high background rates has been studied at the Gamma Irradiation Facility (GIF) at CERN and in an intense 20 MeV proton beam at the Munich Van-der-Graaf tandem accelerator for applications in large-area precision muon tracking at high-luminosity upgrades of the Large Hadron Collider (LHC). The ATLAS muon drifttube (MDT) chambers with 30 mm tube diameter have been designed to cope with and neutron background hit rates of up to 500 Hz/square cm. Background rates of up to 14 kHz/square cm are expected at LHC upgrades. The test results with standard MDT readout electronics show that the reduction of the drift-tube diameter to 15 mm, while leaving the operating parameters unchanged, vastly increases the rate capability well beyond the requirements. The development of new small-diameter muon drift-tube (sMDT) chambers for LHC upgrades is completed. Further improvements of tracking efficiency and spatial resolution at high counting rates will be achieved with upgraded readout electronics employing improved signal sha** for high counting rates.
△ Less
Submitted 31 March, 2016;
originally announced March 2016.
-
Development of Muon Drift-Tube Detectors for High-Luminosity Upgrades of the Large Hadron Collider
Authors:
B. Bittner,
J. Dubbert,
O. Kortner,
H. Kroha,
F. Legger,
R. Richter,
O. Biebel,
A. Engl,
R. Hertenberger,
F. Rauscher
Abstract:
The muon detectors of the experiments at the Large Hadron Collider (LHC) have to cope with unprecedentedly high neutron and gamma ray background rates. In the forward regions of the muon spectrometer of the ATLAS detector, for instance, counting rates of 1.7 kHz/square cm are reached at the LHC design luminosity. For high-luminosity upgrades of the LHC, up to 10 times higher background rates are e…
▽ More
The muon detectors of the experiments at the Large Hadron Collider (LHC) have to cope with unprecedentedly high neutron and gamma ray background rates. In the forward regions of the muon spectrometer of the ATLAS detector, for instance, counting rates of 1.7 kHz/square cm are reached at the LHC design luminosity. For high-luminosity upgrades of the LHC, up to 10 times higher background rates are expected which require replacement of the muon chambers in the critical detector regions. Tests at the CERN Gamma Irradiation Facility showed that drift-tube detectors with 15 mm diameter aluminum tubes operated with Ar:CO2 (93:7) gas at 3 bar and a maximum drift time of about 200 ns provide efficient and high-resolution muon tracking up to the highest expected rates. For 15 mm tube diameter, space charge effects deteriorating the spatial resolution at high rates are strongly suppressed. The sense wires have to be positioned in the chamber with an accuracy of better than 50 ?micons in order to achieve the desired spatial resolution of a chamber of 50 ?microns up to the highest rates. We report about the design, construction and test of prototype detectors which fulfill these requirements.
△ Less
Submitted 31 March, 2016;
originally announced March 2016.
-
Studies on fast triggering and high precision tracking with Resistive Plate Chambers
Authors:
G. Aielli,
B. Bilki,
R. Ball,
J. W. Chapman,
R. Cardarelli,
T. Dai,
E. Diehl,
J. Dubbert,
C. Ferretti,
H. Feng,
K. Francis,
L. Guan,
L. Han,
S. Hou,
D. Levin,
B. Li,
L. Liu,
L. Paolozzi,
J. Repond,
J. Roloff,
R. Santonico,
H. Y. Song,
X. L. Wang,
Y. Wu,
L. Xia
, et al. (5 additional authors not shown)
Abstract:
We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with readout strips with 1.27 mm pitch. This is the first beam test of RPCs with fine-pitch readout strips that explores simultaneously precision tracking and triggering…
▽ More
We report on studies of fast triggering and high-precision tracking using Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180 GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped with readout strips with 1.27 mm pitch. This is the first beam test of RPCs with fine-pitch readout strips that explores simultaneously precision tracking and triggering capabilities. RPC signals were acquired with precision timing and charge integrating readout electronics at both ends of the strips. The time resolution was measured to be better than 600 ps and the average spatial resolution was found to be 220 um using charge information and 287 um using timing information. The dual-ended readout allows the determination of the average and the difference of the signal arrival times. The average time was found to be independent of the incident particle position along the strip and is useful for triggering purposes. The time difference yielded a determination of the hit position with a precision of 7.5 mm along the strip. These results demonstrate the feasibility using RPCs for fast and high-resolution triggering and tracking.
△ Less
Submitted 24 October, 2012;
originally announced October 2012.
-
High Rate Proton Irradiation of 15mm Muon Drifttubes
Authors:
Andre Zibell,
Otmar Biebel,
Ralf Hertenberger,
Alexander Ruschke,
Christopher Schmitt,
Hubert Kroha,
Bernhard Bittner,
Philipp Schwegler,
Jörg Dubbert,
Sebastian Ott
Abstract:
Future LHC luminosity upgrades will significantly increase the amount of background hits from photons, neutrons and protons in the detectors of the ATLAS muon spectrometer. At the proposed LHC peak luminosity of 5*10^34 1/cm^2s, background hit rates of more than 10 kHz/cm^2 are expected in the innermost forward region, leading to a loss of performance of the current tracking chambers. Based on the…
▽ More
Future LHC luminosity upgrades will significantly increase the amount of background hits from photons, neutrons and protons in the detectors of the ATLAS muon spectrometer. At the proposed LHC peak luminosity of 5*10^34 1/cm^2s, background hit rates of more than 10 kHz/cm^2 are expected in the innermost forward region, leading to a loss of performance of the current tracking chambers. Based on the ATLAS Monitored Drift Tube chambers, a new high rate capable drift tube detecor using tubes with a reduced diameter of 15mm was developed. To test the response to highly ionizing particles, a prototype chamber of 46 15mm drift tubes was irradiated with a 20 MeV proton beam at the tandem accelerator at the Maier-Leibnitz Laboratory, Munich. Three tubes in a planar layer were irradiated while all other tubes were used for reconstruction of cosmic muon tracks through irradiated and non-irradiated parts of the chamber. To determine the rate capability of the 15mm drift-tubes we investigated the effect of the proton hit rate on pulse height, efficiency and spatial resolution of the cosmic muon signals.
△ Less
Submitted 13 March, 2012;
originally announced March 2012.
-
Streamlined Calibrations of the ATLAS Precision Muon Chambers for Initial LHC Running
Authors:
N. Amram,
R. Ball,
Y. Benhammou,
M. Ben Moshe,
T. Dai,
E. B. Diehl,
J. Dubbert,
E. Etzion,
C. Ferretti,
J. Gregory,
S. Haider,
J. Hindes,
D. S. Levin,
R. Thun,
A. Wilson,
C. Weaverdyck,
Y. Wu,
H. Yang,
B. Zhou,
S. Zimmermann
Abstract:
The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p = 3% and 10% at 100 GeV and 1 TeV momentum respectively. For this task, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) arrayed in 1200 Chambers. Calibration (RT) functions convert drift time measurements into tube-centered impact parameters for track segment reconstruction. RT function…
▽ More
The ATLAS Muon Spectrometer is designed to measure the momentum of muons with a resolution of dp/p = 3% and 10% at 100 GeV and 1 TeV momentum respectively. For this task, the spectrometer employs 355,000 Monitored Drift Tubes (MDTs) arrayed in 1200 Chambers. Calibration (RT) functions convert drift time measurements into tube-centered impact parameters for track segment reconstruction. RT functions depend on MDT environmental parameters and so must be appropriately calibrated for local chamber conditions. We report on the creation and application of a gas monitor system based calibration program for muon track reconstruction in the LHC startup phase.
△ Less
Submitted 7 March, 2011; v1 submitted 3 March, 2011;
originally announced March 2011.
-
Upgrade of the ATLAS Muon Trigger for the SLHC
Authors:
Jörg Dubbert,
Sandra Horvat,
Oliver Kortner,
Hubert Kroha,
Robert Richter
Abstract:
The outer shell of the ATLAS experiment at the LHC consists of a system of toroidal air-core magnets in order to allow for the precise measurement of the transverse momentum p$_T$ of muons, which in many physics channels are a signature of interesting physics processes. For the precise determination of the muon momentum Monitored Drift Tube chambers (MDT) with high position accuracy are used, whil…
▽ More
The outer shell of the ATLAS experiment at the LHC consists of a system of toroidal air-core magnets in order to allow for the precise measurement of the transverse momentum p$_T$ of muons, which in many physics channels are a signature of interesting physics processes. For the precise determination of the muon momentum Monitored Drift Tube chambers (MDT) with high position accuracy are used, while for the fast identification of muon tracks chambers with high time resolution are used, able to select muons above a predefined p$_T$ threshold for use in the first Level of the ATLAS triggering system (Level-1 trigger). When the luminosity of the LHC will be upgraded to 4-5 times the present nominal value (SLHC) in about a decade from now, an improvement of the selectivity of the ATLAS Level-1 triggering system will be mandatory in order to cope with the maximum allowed trigger rate of 100 kHz. For the Level-1 trigger of the ATLAS muon spectrometer this means an increase of the p$_T$ threshold for single muons. Due to the limited spatial resolution of the trigger chambers, however, the selectivity for tracks above ~20 GeV/c is insufficient for an effective reduction of the Level-1 rate. We describe how the track coordinates measured in the MDT precision chambers can be used to decisively improve the selectivity for high momentum tracks. The resulting increase in latency will also be discussed.
△ Less
Submitted 31 October, 2010;
originally announced November 2010.
-
A Cosmic Ray Measurement Facility for ATLAS Muon Chambers
Authors:
O. Biebel,
M. Binder,
M. Boutemeur,
A. Brandt,
J. Dubbert,
G. Duckeck,
J. Elmsheuser,
F. Fiedler,
R. Hertenberger,
O. Kortner,
T. Nunnemann,
F. Rauscher,
D. Schaile,
P. Schieferdecker,
A. Staude,
W. Stiller,
R. Stroehmer,
R. Vertesi
Abstract:
Monitored Drift Tube (MDT) chambers will constitute the large majority of precision detectors in the Muon Spectrometer of the ATLAS experiment at the Large Hadron Collider at CERN. For commissioning and calibration of MDT chambers, a Cosmic Ray Measurement Facility is in operation at Munich University. The objectives of this facility are to test the chambers and on-chamber electronics, to map th…
▽ More
Monitored Drift Tube (MDT) chambers will constitute the large majority of precision detectors in the Muon Spectrometer of the ATLAS experiment at the Large Hadron Collider at CERN. For commissioning and calibration of MDT chambers, a Cosmic Ray Measurement Facility is in operation at Munich University. The objectives of this facility are to test the chambers and on-chamber electronics, to map the positions of the anode wires within the chambers with the precision needed for standalone muon momentum measurement in ATLAS, and to gain experience in the operation of the chambers and on-line calibration procedures.
Until the start of muon chamber installation in ATLAS, 88 chambers built at the Max Planck Institute for Physics in Munich have to be commissioned and calibrated. With a data taking period of one day individual wire positions can be measured with an accuracy of 8.3 micrometers in the chamber plane and 27 micrometers in the direction perpendicular to that plane.
△ Less
Submitted 30 July, 2003;
originally announced July 2003.