-
Projected background and sensitivity of AMoRE-II
Authors:
A. Agrawal,
V. V. Alenkov,
P. Aryal,
J. Beyer,
B. Bhandari,
R. S. Boiko,
K. Boonin,
O. Buzanov,
C. R. Byeon,
N. Chanthima,
M. K. Cheoun,
J. S. Choe,
Seonho Choi,
S. Choudhury,
J. S. Chung,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Y. M. Gavrilyuk,
A. M. Gezhaev,
O. Gileva
, et al. (81 additional authors not shown)
Abstract:
AMoRE-II aims to search for neutrinoless double beta decay with an array of 423 Li$_2$$^{100}$MoO$_4$ crystals operating in the cryogenic system as the main phase of the Advanced Molybdenum-based Rare process Experiment (AMoRE). AMoRE has been planned to operate in three phases: AMoRE-pilot, AMoRE-I, and AMoRE-II. AMoRE-II is currently being installed at the Yemi Underground Laboratory, located ap…
▽ More
AMoRE-II aims to search for neutrinoless double beta decay with an array of 423 Li$_2$$^{100}$MoO$_4$ crystals operating in the cryogenic system as the main phase of the Advanced Molybdenum-based Rare process Experiment (AMoRE). AMoRE has been planned to operate in three phases: AMoRE-pilot, AMoRE-I, and AMoRE-II. AMoRE-II is currently being installed at the Yemi Underground Laboratory, located approximately 1000 meters deep in Jeongseon, Korea. The goal of AMoRE-II is to reach up to $T^{0νββ}_{1/2}$ $\sim$ 6 $\times$ 10$^{26}$ years, corresponding to an effective Majorana mass of 15 - 29 meV, covering all the inverted mass hierarchy regions. To achieve this, the background level of the experimental configurations and possible background sources of gamma and beta events should be well understood. We have intensively performed Monte Carlo simulations using the GEANT4 toolkit in all the experimental configurations with potential sources. We report the estimated background level that meets the 10$^{-4}$counts/(keV$\cdot$kg$\cdot$yr) requirement for AMoRE-II in the region of interest (ROI) and show the projected half-life sensitivity based on the simulation study.
△ Less
Submitted 13 June, 2024;
originally announced June 2024.
-
Alpha backgrounds in the AMoRE-Pilot experiment
Authors:
V. Alenkov,
H. W. Bae,
J. Beyer,
R. S. Boiko,
K. Boonin,
O. Buzanov,
N. Chanthima,
M. K. Cheoun,
S. H. Choi,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. Gangapshev,
L. Gastaldo,
Yu. M. Gavriljuk,
A. Gezhaev,
V. D. Grigoryeva,
V. Gurentsov,
D. H. Ha,
C. Ha,
E. J. Ha,
I. Hahn,
E. J. Jeon
, et al. (81 additional authors not shown)
Abstract:
The Advanced Mo-based Rare process Experiment (AMoRE)-Pilot experiment is an initial phase of the AMoRE search for neutrinoless double beta decay of $^{100}$Mo, with the purpose of investigating the level and sources of backgrounds. Searches for neutrinoless double beta decay generally require ultimately low backgrounds. Surface $α$ decays on the crystals themselves or nearby materials can deposit…
▽ More
The Advanced Mo-based Rare process Experiment (AMoRE)-Pilot experiment is an initial phase of the AMoRE search for neutrinoless double beta decay of $^{100}$Mo, with the purpose of investigating the level and sources of backgrounds. Searches for neutrinoless double beta decay generally require ultimately low backgrounds. Surface $α$ decays on the crystals themselves or nearby materials can deposit a continuum of energies that can be as high as the $Q$-value of the decay itself and may fall in the region of interest (ROI). To understand these background events, we studied backgrounds from radioactive contaminations internal to and on the surface of the crystals or nearby materials with Geant4-based Monte Carlo simulations. In this study, we report on the measured $α$ energy spectra fitted with the corresponding simulated spectra for six crystal detectors, where sources of background contributions could be identified through high energy $α$ peaks and continuum parts in the energy spectrum for both internal and surface contaminations. We determine the low-energy contributions from internal and surface $α$ contaminations by extrapolating from the $α$ background fitting model.
△ Less
Submitted 5 December, 2022; v1 submitted 16 July, 2021;
originally announced July 2021.
-
Improvements of the programmable quantum current generator for better traceability of electrical current measurements
Authors:
Sophie Djordjevic,
Ralf Behr,
Dietmar Drung,
Martin Götz,
Wilfrid Poirier
Abstract:
A programmable quantum current generator based on the application of Ohm's law to quantum voltage and resistance standards has demonstrated a realization of the ampere from the elementary charge with a $10^{-8}$ relative uncertainty [J. Brun-Picard et al. PRX 6, 041051, 2016]. Here, we report on improvements of the device leading to a noise reduction of the generated quantized current. The improve…
▽ More
A programmable quantum current generator based on the application of Ohm's law to quantum voltage and resistance standards has demonstrated a realization of the ampere from the elementary charge with a $10^{-8}$ relative uncertainty [J. Brun-Picard et al. PRX 6, 041051, 2016]. Here, we report on improvements of the device leading to a noise reduction of the generated quantized current. The improved quantum current generator is used to calibrate different ammeters with lower measurement uncertainties. Besides, measurements of its quantized current using a calibrated Ultrastable Low-Noise Current Amplifier (ULCA) have shown that the realizations of the ampere at PTB (Physikalisch-Technische Bundesanstalt) and LNE (Laboratoire national de métrologie et d'essais) in the range $\pm50$ $μ$A agreed to -3.7 parts in $10^{7}$ with a combined standard uncertainty of 3.1 parts in $10^{7}$ (coverage factor $k_\mathrm{c}=1$).
△ Less
Submitted 9 June, 2021;
originally announced June 2021.
-
First Results from the AMoRE-Pilot neutrinoless double beta decay experiment
Authors:
V. Alenkov,
H. W. Bae,
J. Beyer,
R. S. Boiko,
K. Boonin,
O. Buzanov,
N. Chanthima,
M. K. Cheoun,
D. M. Chernyak,
J. S. Choe,
S. Choi,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Yu. M. Gavriljuk,
A. M. Gezhaev,
V. D. Grigoryeva,
V. I. Gurentsov,
O. Gylova,
C. Ha,
D. H. Ha
, et al. (84 additional authors not shown)
Abstract:
The Advanced Molybdenum-based Rare process Experiment (AMoRE) aims to search for neutrinoless double beta decay (0$νββ$) of $^{100}$Mo with $\sim$100 kg of $^{100}$Mo-enriched molybdenum embedded in cryogenic detectors with a dual heat and light readout. At the current, pilot stage of the AMoRE project we employ six calcium molybdate crystals with a total mass of 1.9 kg, produced from $^{48}$Ca-de…
▽ More
The Advanced Molybdenum-based Rare process Experiment (AMoRE) aims to search for neutrinoless double beta decay (0$νββ$) of $^{100}$Mo with $\sim$100 kg of $^{100}$Mo-enriched molybdenum embedded in cryogenic detectors with a dual heat and light readout. At the current, pilot stage of the AMoRE project we employ six calcium molybdate crystals with a total mass of 1.9 kg, produced from $^{48}$Ca-depleted calcium and $^{100}$Mo-enriched molybdenum ($^{48\textrm{depl}}$Ca$^{100}$MoO$_4$). The simultaneous detection of heat(phonon) and scintillation (photon) signals is realized with high resolution metallic magnetic calorimeter sensors that operate at milli-Kelvin temperatures. This stage of the project is carried out in the Yangyang underground laboratory at a depth of 700 m. We report first results from the AMoRE-Pilot $0νββ$ search with a 111 kg$\cdot$d live exposure of $^{48\textrm{depl}}$Ca$^{100}$MoO$_4$ crystals. No evidence for $0νββ$ decay of $^{100}$Mo is found, and a upper limit is set for the half-life of 0$νββ$ of $^{100}$Mo of $T^{0ν}_{1/2} > 9.5\times10^{22}$ y at 90% C.L.. This limit corresponds to an effective Majorana neutrino mass limit in the range $\langle m_{ββ}\rangle\le(1.2-2.1)$ eV.
△ Less
Submitted 7 May, 2019; v1 submitted 22 March, 2019;
originally announced March 2019.
-
Inter-laboratory nanoamp current comparison with sub-part-per-million uncertainty
Authors:
Stephen Giblin,
Dietmar Drung,
Martin Goetz,
Hansjoerg Scherer
Abstract:
An ultrastable low-noise current amplifier (ULCA) has been transferred between two laboratories, NPL and PTB, four times, with three of the transfers yielding a relative change in the trans-resistance gain of less than $2 \times 10^{-7}$. This is a new bench-mark for inter-laboratory transfer of small current. We describe in detail the use of a cryogenic current comparator to calibrate the ULCA at…
▽ More
An ultrastable low-noise current amplifier (ULCA) has been transferred between two laboratories, NPL and PTB, four times, with three of the transfers yielding a relative change in the trans-resistance gain of less than $2 \times 10^{-7}$. This is a new bench-mark for inter-laboratory transfer of small current. We describe in detail the use of a cryogenic current comparator to calibrate the ULCA at NPL, and the use of the ULCA to measure $1$ G$Ω$ resistors with relative uncertainties at the $10^{-7}$ level.
△ Less
Submitted 29 August, 2018;
originally announced August 2018.
-
Electrometer calibration with sub-part-per-million uncertainty
Authors:
Hansjörg Scherer,
Dietmar Drung,
Christian Krause,
Martin Götz,
Ulrich Becker
Abstract:
We performed calibrations of four different commercial picoammeters using the Ultrastable Low-noise Current Amplifier (ULCA) as a calibrator current source operated in the range between 1 femtoampere and 1 microampere. The results allow the comprehensive characterization of the devices under test regarding noise, settling and burden voltage behavior as well as stability of the gain factor, and con…
▽ More
We performed calibrations of four different commercial picoammeters using the Ultrastable Low-noise Current Amplifier (ULCA) as a calibrator current source operated in the range between 1 femtoampere and 1 microampere. The results allow the comprehensive characterization of the devices under test regarding noise, settling and burden voltage behavior as well as stability of the gain factor, and confirm the performance of the ULCA for use as small-current calibrator standard. Also, we present a further advanced setup for the calibration of transimpedance amplifiers. Accuracy limits for best electrometer calibrations in the current range between 1 femtoampere and 1 microampere and possible implications on corresponding calibration and measurement capabilities are discussed.
△ Less
Submitted 22 November, 2018; v1 submitted 27 August, 2018;
originally announced August 2018.
-
A modular, extendible and field-tolerant multichannel vector magnetometer based on current sensor SQUIDs
Authors:
Jan-Hendrik Storm,
Dietmar Drung,
Martin Burghoff,
Rainer Körber
Abstract:
We present the prototype module of our extendible and robust multichannel SQUID magnetometer system. A multi-module arrangement can be implemented by using up to 7 modules. It is intended for high-precision measurements of biomagnetism and spin precession. Further demanding applications are magnetorelaxometry and ultra-low-field nuclear magnetic resonance (ULF NMR), where pulsed fields of up to 10…
▽ More
We present the prototype module of our extendible and robust multichannel SQUID magnetometer system. A multi-module arrangement can be implemented by using up to 7 modules. It is intended for high-precision measurements of biomagnetism and spin precession. Further demanding applications are magnetorelaxometry and ultra-low-field nuclear magnetic resonance (ULF NMR), where pulsed fields of up to 100 mT are typically applied. The system is operated inside the Berlin Magnetically Shielded Room and equipped with 18 magnetometers consisting of niobium (Nb) wire-wound pick-up coils. A total of 16 small pick-up coils with 17.1 mm diameter form a regular grid with individual channels arranged to ensure system sensitivity covers all three orthogonal spatial directions. Two large hexagonal pick-up coils with an equivalent diameter of 74.5 mm sensitive in z-direction surround the grid at two different heights and are suitable for the detection of deep sources. Each coil is connected to the input of a thin-film Nb SQUID current sensor via a detachable superconducting contact. The SQUIDs are equipped with integrated input current limiters. Feedback into the pick-up coils minimizes crosstalk between channels. The current sensor chip package includes a superconducting shield of Nb. The field distortion of the prototype and a multi-module arrangement was analysed by numerical simulation. The measured noise of the small magnetometers was between 0.6 and 1.5 fT/Hz$^{1/2}$, and well below 1 fT/Hz$^{1/2}$ for the large ones. Using a software gradiometer, we achieved a minimum noise level of 0.54 fT/Hz$^{1/2}$. We performed ULF NMR experiments, verifying the system's robustness against pulsed fields, and magnetoencephalographgy (MEG) on somatosensory evoked neuronal activity. The low noise performance of our 18-channel prototype enabled the detection of high-frequency components at around 1 kHz by MEG.
△ Less
Submitted 28 August, 2017;
originally announced August 2017.
-
An ultra-sensitive and wideband magnetometer based on a superconducting quantum interference device
Authors:
Jan-Hendrik Storm,
Peter Hömmen,
Dietmar Drung,
Rainer Körber
Abstract:
The magnetic field noise in superconducting quantum interference devices (SQUIDs) used for biomagnetic research such as magnetoencephalography or ultra-low-field nuclear magnetic resonance is usually limited by instrumental dewar noise. We constructed a wideband, ultra-low noise system with a 45 mm diameter superconducting pick-up coil inductively coupled to a current sensor SQUID. Thermal noise i…
▽ More
The magnetic field noise in superconducting quantum interference devices (SQUIDs) used for biomagnetic research such as magnetoencephalography or ultra-low-field nuclear magnetic resonance is usually limited by instrumental dewar noise. We constructed a wideband, ultra-low noise system with a 45 mm diameter superconducting pick-up coil inductively coupled to a current sensor SQUID. Thermal noise in the liquid helium dewar is minimized by using aluminized polyester fabric as superinsulation and aluminum oxide strips as heat shields, respectively. With a magnetometer pick-up coil in the center of the Berlin magneti- cally shielded room 2 (BMSR2) a noise level of around 150 aT Hz$^{-1/2}$ is achieved in the white noise regime between about 20 kHz and the system bandwidth of about 2.5 MHz. At lower frequencies, the resolution is limited by magnetic field noise arising from the walls of the shielded room. Modeling the BMSR2 as a closed cube with continuous μ-metal walls we can quantitatively reproduce its measured field noise.
△ Less
Submitted 17 February, 2017;
originally announced February 2017.
-
Reducing current noise in cryogenic experiments by vacuum-insulated cables
Authors:
E. Mykkänen,
J. S. Lehtinen,
A. Kemppinen,
C. Krause,
D. Drung,
J. Nissilä,
A. J. Manninen
Abstract:
We measure the current noise of several cryogenic cables in a pulse tube based dilution refrigerator at frequencies between about 1~mHz and 50~kHz. We show that vibration-induced noise can be efficiently suppressed by using vacuum-insulated cables between room temperature and the 2nd pulse tube stage. A noise peak below 4 fA at the 1.4~Hz operation frequency of the pulse tube, and a white noise de…
▽ More
We measure the current noise of several cryogenic cables in a pulse tube based dilution refrigerator at frequencies between about 1~mHz and 50~kHz. We show that vibration-induced noise can be efficiently suppressed by using vacuum-insulated cables between room temperature and the 2nd pulse tube stage. A noise peak below 4 fA at the 1.4~Hz operation frequency of the pulse tube, and a white noise density of 0.44 fA/\sqrt{Hz} in the millihertz range are obtained.
△ Less
Submitted 29 August, 2016; v1 submitted 13 April, 2016;
originally announced April 2016.
-
Improved Calibration of Instruments for Small Direct Currents
Authors:
Hansjörg Scherer,
Dietmar Drung,
Christian Krause
Abstract:
We report on new calibration methods for picoammeters and low-current sources. The "Ultrastable Low-noise Current Amplifier" (ULCA) was used for the exemplary calibration of commercial state-of-the-art ammeter and current source instruments in the current range between 1 femtoampere and 1 microampere. The uncertainties achieved are compared with results obtained from two other calibration methods…
▽ More
We report on new calibration methods for picoammeters and low-current sources. The "Ultrastable Low-noise Current Amplifier" (ULCA) was used for the exemplary calibration of commercial state-of-the-art ammeter and current source instruments in the current range between 1 femtoampere and 1 microampere. The uncertainties achieved are compared with results obtained from two other calibration methods for small direct currents. It is shown that using the ULCA as calibrator allows achieving lower uncertainties together with the benefit of easier handling compared to alternative techniques. Also, the ULCA allows performing current meter and source calibrations between 1 femtoampere and 1 microampere with a single method.
△ Less
Submitted 23 March, 2016;
originally announced March 2016.
-
Technical Design Report for the AMoRE $0νββ$ Decay Search Experiment
Authors:
V. Alenkov,
P. Aryal,
J. Beyer,
R. S. Boiko,
K. Boonin,
O. Buzanov,
N. Chanthima,
M. K. Cheoun D. M. Chernyak,
J. Choi,
S. Choi,
F. A. Danevich,
M. Djamal,
D. Drung,
C. Enss,
A. Fleischmann,
A. M. Gangapshev,
L. Gastaldo,
Yu. M. Gavriljuk,
A. M. Gezhaev,
V. I. Gurentsov,
D. H Ha,
I. S. Hahn,
J. H. Jang,
E. J. Jeon,
H. S. Jo
, et al. (65 additional authors not shown)
Abstract:
The AMoRE (Advanced Mo-based Rare process Experiment) project is a series of experiments that use advanced cryogenic techniques to search for the neutrinoless double-beta decay of \mohundred. The work is being carried out by an international collaboration of researchers from eight countries. These searches involve high precision measurements of radiation-induced temperature changes and scintillati…
▽ More
The AMoRE (Advanced Mo-based Rare process Experiment) project is a series of experiments that use advanced cryogenic techniques to search for the neutrinoless double-beta decay of \mohundred. The work is being carried out by an international collaboration of researchers from eight countries. These searches involve high precision measurements of radiation-induced temperature changes and scintillation light produced in ultra-pure \Mo[100]-enriched and \Ca[48]-depleted calcium molybdate ($\mathrm{^{48depl}Ca^{100}MoO_4}$) crystals that are located in a deep underground laboratory in Korea. The \mohundred nuclide was chosen for this \zeronubb decay search because of its high $Q$-value and favorable nuclear matrix element. Tests have demonstrated that \camo crystals produce the brightest scintillation light among all of the molybdate crystals, both at room and at cryogenic temperatures. $\mathrm{^{48depl}Ca^{100}MoO_4}$ crystals are being operated at milli-Kelvin temperatures and read out via specially developed metallic-magnetic-calorimeter (MMC) temperature sensors that have excellent energy resolution and relatively fast response times. The excellent energy resolution provides good discrimination of signal from backgrounds, and the fast response time is important for minimizing the irreducible background caused by random coincidence of two-neutrino double-beta decay events of \mohundred nuclei. Comparisons of the scintillating-light and phonon yields and pulse shape discrimination of the phonon signals will be used to provide redundant rejection of alpha-ray-induced backgrounds. An effective Majorana neutrino mass sensitivity that reaches the expected range of the inverted neutrino mass hierarchy, i.e., 20-50 meV, could be achieved with a 200~kg array of $\mathrm{^{48depl}Ca^{100}MoO_4}$ crystals operating for three years.
△ Less
Submitted 18 December, 2015;
originally announced December 2015.
-
Validation of the ultrastable low-noise current amplifier as travelling standard for small direct currents
Authors:
Dietmar Drung,
Christian Krause,
Stephen P. Giblin,
Sophie Djordjevic,
Francois Piquemal,
Olivier Séron,
Florentin Rengnez,
Martin Götz,
Eckart Pesel,
Hansjörg Scherer
Abstract:
An interlaboratory comparison of small-current generation and measurement capability is presented with the ultrastable low-noise current amplifier (ULCA) acting as travelling standard. Various measurements at direct currents between 0.16 nA and 13 nA were performed to verify the degree of agreement between the three national metrology institutes involved in the study. Consistency well within one p…
▽ More
An interlaboratory comparison of small-current generation and measurement capability is presented with the ultrastable low-noise current amplifier (ULCA) acting as travelling standard. Various measurements at direct currents between 0.16 nA and 13 nA were performed to verify the degree of agreement between the three national metrology institutes involved in the study. Consistency well within one part per million (ppm) was found. Due to harsh environmental conditions during shipment, the ULCA's transfer accuracy had been limited to about +/-0.4 ppm. Supplemental measurements performed at PTB indicate that further improvements in accuracy are possible. Relative uncertainties of 0.1 ppm are achieved by applying on-site calibration of the ULCA with a suitable cryogenic current comparator.
△ Less
Submitted 1 July, 2015;
originally announced July 2015.
-
Ultrastable low-noise current amplifier
Authors:
Dietmar Drung,
Christian Krause,
Ulrich Becker,
Hansjörg Scherer,
Franz Josef Ahlers
Abstract:
An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current gain and the second performing a current-to-voltage conversion via an internal 1 MOhm reference resistor or, optionally, an external standard resistor. The ULC…
▽ More
An ultrastable low-noise current amplifier (ULCA) is presented. The ULCA is a non-cryogenic instrument based on specially designed operational amplifiers and resistor networks. It involves two stages, the first providing a 1000-fold current gain and the second performing a current-to-voltage conversion via an internal 1 MOhm reference resistor or, optionally, an external standard resistor. The ULCA's transfer coefficient is extremely stable versus time, temperature and current amplitude within the full dynamic range of +/-5 nA. A low noise level of 2.4 fA/sqrt(Hz) helps to keep averaging times low at small input currents. A cryogenic current comparator is used to calibrate both input current gain and output transresistance, providing traceability to the quantum Hall effect. Typically, within one day after calibration, the uncertainty contribution from short-term fluctuations of the transresistance is below one part in 10^7. The long-term stability is expected to be better than one part in 10^5 over a year. A high-precision variant is available that shows a substantially improved stability at the expense of a higher noise level of 7.5 fA/sqrt(Hz). The ULCA also allows the traceable generation of small electrical currents or the calibration of high-ohmic resistors.
△ Less
Submitted 21 August, 2014;
originally announced August 2014.
-
Traceable precision pA direct current measurements with the ULCA
Authors:
Hansjörg Scherer,
Gerd-Dietmar Willenberg,
Dietmar Drung,
Martin Götz,
Eckart Pesel
Abstract:
A standard method for picoammeter calibrations is the capacitor charging technique, which allows generating traceable currents in the sub-nA range. However, its accuracy is limited by the ac-dc differences of the capacitances involved. The Ultrastable Low-noise Current Amplifier (ULCA) is a novel high-precision amperemeter for direct current measurements in the pA range, developed at PTB. Its ampl…
▽ More
A standard method for picoammeter calibrations is the capacitor charging technique, which allows generating traceable currents in the sub-nA range. However, its accuracy is limited by the ac-dc differences of the capacitances involved. The Ultrastable Low-noise Current Amplifier (ULCA) is a novel high-precision amperemeter for direct current measurements in the pA range, developed at PTB. Its amplifier stages, based on resistor networks and op-amps, can be calibrated traceably with a cryogenic current comparator (CCC) system. We compare the results from both independent calibration routes for two different ULCA prototypes. We find agreement between both methods at an uncertainty level below 10 microA/A, limited by the uncertainty of the currents generated with the capacitor charging method. The investigations confirm the superior performance of the new ULCA picoammeter.
△ Less
Submitted 6 August, 2014; v1 submitted 21 July, 2014;
originally announced July 2014.
-
Traceable precision generation and measurement of pA direct currents
Authors:
Hansjörg Scherer,
Gerd-Dietmar Willenberg,
Dietmar Drung,
Martin Götz,
Eckart Pesel
Abstract:
We present the comparison of results from the generation and the measurement of direct currents in the pA range, performed with traceable state-of-the-art methods at highest accuracy. The currents were generated with the capacitor charging method, and measured with the first prototype of a novel picoammeter developed at PTB. The results confirm the agreement between both methods and the linearity…
▽ More
We present the comparison of results from the generation and the measurement of direct currents in the pA range, performed with traceable state-of-the-art methods at highest accuracy. The currents were generated with the capacitor charging method, and measured with the first prototype of a novel picoammeter developed at PTB. The results confirm the agreement between both methods and the linearity of the new picoammeter at an uncertainty level of few microA/A. Also, they shed light on the ac-dc difference of capacitors, crucial for current generation with the capacitor charging method.
△ Less
Submitted 18 June, 2014;
originally announced June 2014.
-
Current Sensing Noise Thermometry: A fast practical solution to low temperature measurement
Authors:
Andrew Casey,
Frank Arnold,
Lev V. Levitin,
Chris P. Lusher,
John Saunders,
Aya Shibahara,
Harriet van der Vliet,
Dietmar Drung,
Thomas Schurig,
Graham Batey,
Michael Cuthbert,
Anthony Matthews
Abstract:
We describe the design and performance of a series of fast, precise current sensing noise thermometers. The thermometers have been fabricated with a range of resistances from 1.290 $Ω$ down to 0.2 m$\mathrmΩ$. This results in either a thermometer that has been optimised for speed, taking advantage of the improvements in superconducting quantum interference device (SQUID) noise and bandwidth, or a…
▽ More
We describe the design and performance of a series of fast, precise current sensing noise thermometers. The thermometers have been fabricated with a range of resistances from 1.290 $Ω$ down to 0.2 m$\mathrmΩ$. This results in either a thermometer that has been optimised for speed, taking advantage of the improvements in superconducting quantum interference device (SQUID) noise and bandwidth, or a thermometer optimised for ultra-low temperature measurement, minimising the system noise temperature. By using a single temperature calibration point, we show that noise thermometers can be used for accurate measurements over a wide range of temperatures below 4 K. Comparisons with a melting curve thermometer, a calibrated germanium thermometer and a pulsed platinum nuclear magnetic resonance thermometer are presented. For the 1.290 $\mathrmΩ$ resistance we measure a 1 % precision in just 100 ms, and have shown this to be independent of temperature.
△ Less
Submitted 15 November, 2013; v1 submitted 13 November, 2013;
originally announced November 2013.
-
Micro-coil detection of Nuclear Magnetic Resonance for nanofluidic samples
Authors:
Aya Shibahara,
Andrew Casey,
Chris Lusher,
John Saunders,
Cornelia Aßmann,
Thomas Schurig,
Dietmar Drung
Abstract:
We have developed a novel dc SQUID system with a micro-coil input circuit to act as a local probe of quantum matter and nanosystems. The planar niobium micro-coil pickup loop is located remotely from the SQUID, coupled through a superconducting twisted pair, enabling the sample to be at microkelvin temperatures. A high degree of coupling between the coil and the region of interest of similar dimen…
▽ More
We have developed a novel dc SQUID system with a micro-coil input circuit to act as a local probe of quantum matter and nanosystems. The planar niobium micro-coil pickup loop is located remotely from the SQUID, coupled through a superconducting twisted pair, enabling the sample to be at microkelvin temperatures. A high degree of coupling between the coil and the region of interest of similar dimensions (up to ~ 100 microns) can be achieved. We report nuclear magnetic resonance (NMR) measurements to characterise the sensitivity of these coils to 3He in the gas phase at 4.2 K in a 30 mT magnetic field.
△ Less
Submitted 8 November, 2013;
originally announced November 2013.