-
Understanding and minimizing resonance frequency deviations on a 4-inch kilo-pixel kinetic inductance detector array
Authors:
S. Shu,
M. Calvo,
J. Goupy,
S. Leclercq,
A. Catalano,
A. Bideaud,
A. Monfardini,
E. F. C. Driessen
Abstract:
One of the advantages of kinetic inductance detectors is their intrinsic frequency domain multiplexing capability. However, fabrication imperfections usually give rise to resonance frequency deviations, which create frequency collision and limit the array yield. Here we study the resonance frequency deviation of a 4-inch kilo-pixel lumped-element kinetic inductance detector (LEKID) array using opt…
▽ More
One of the advantages of kinetic inductance detectors is their intrinsic frequency domain multiplexing capability. However, fabrication imperfections usually give rise to resonance frequency deviations, which create frequency collision and limit the array yield. Here we study the resonance frequency deviation of a 4-inch kilo-pixel lumped-element kinetic inductance detector (LEKID) array using optical map**. Using the measured resonator dimensions and film thickness, the fractional deviation can be explained within $\pm 25\times 10^{-3}$, whereas the residual deviation is due to variation of electric film properties. Using the capacitor trimming technique, the fractional deviation is decreased by a factor of 14. The yield of the trimming process is found to be 97%. The map** yield, measured under a 110~K background, is improved from 69% to 76%, which can be further improved to 81% after updating our readout system. With the improvement in yield, the capacitor trimming technique may benefit future large-format LEKID arrays.
△ Less
Submitted 30 August, 2021; v1 submitted 28 May, 2021;
originally announced May 2021.
-
Observing with NIKA2Pol from the IRAM 30m telescope. Early results on the commissioning phase
Authors:
A. Ritacco,
R. Adam,
P. Ade,
H. Ajeddig,
P. André,
A. Andrianasolo,
H. Aussel,
A. Beelen,
A. Benoît,
A. Bideaud,
O. Bourrion,
M. Calvo,
A. Catalano,
B. Comis,
M. De Petris,
F. -X. Désert,
S. Doyle,
E. F. C. Driessen,
A. Gomez,
J. Goupy,
F. Kéruzoré,
C. Kramer,
B. Ladjelate,
G. Lagache,
S. Leclercq
, et al. (19 additional authors not shown)
Abstract:
The NIKA2 polarization channel at 260 GHz (1.15 mm) has been proposed primarily to observe galactic star-forming regions and probe the critical scales between 0.01-0.05 pc at which magnetic field lines may channel the matter of interstellar filaments into growing dense cores. The NIKA2 polarimeter consists of a room temperature continuously rotating multi-mesh HWP and a cold polarizer that separat…
▽ More
The NIKA2 polarization channel at 260 GHz (1.15 mm) has been proposed primarily to observe galactic star-forming regions and probe the critical scales between 0.01-0.05 pc at which magnetic field lines may channel the matter of interstellar filaments into growing dense cores. The NIKA2 polarimeter consists of a room temperature continuously rotating multi-mesh HWP and a cold polarizer that separates the two orthogonal polarizations onto two 260 GHz KIDs arrays. We describe in this paper the preliminary results obtained during the most recent commissioning campaign performed in December 2018. We concentrate here on the analysis of the extended sources, while the observation of compact sources is presented in a companion paper [12]. We present preliminary NIKA2 polarization maps of the Crab nebula. We find that the integrated polarization intensity flux measured by NIKA2 is consistent with expectations.In terms of polarization angle, we are still limited by systematic uncertainties that will be further investigated in the forthcoming commissioning campaigns.
△ Less
Submitted 17 December, 2019;
originally announced December 2019.
-
Calibration and Performance of the NIKA2 camera at the IRAM 30-meter Telescope
Authors:
L. Perotto,
N. Ponthieu,
J. -F. Macías-Pérez,
R. Adam,
P. Ade,
P. André,
A. Andrianasolo,
H. Aussel,
A. Beelen,
A. Benoît,
S. Berta,
A. Bideaud,
O. Bourrion,
M. Calvo,
A. Catalano,
B. Comis,
M. De Petris,
F. -X. Désert,
S. Doyle,
E. F. C. Driessen,
P. García,
A. Gomez,
J. Goupy,
D. John,
F. Kéruzoré
, et al. (23 additional authors not shown)
Abstract:
NIKA2 is a dual-band millimetric continuum camera of 2900 Kinetic Inductance Detectors (KID), operating at $150$ and $260\,\rm{GHz}$, installed at the IRAM 30-meter telescope. We present the performance assessment of NIKA2 after one year of observation using a dedicated point-source calibration method, referred to as the \emph{baseline} method. Using a large data set acquired between January 2017…
▽ More
NIKA2 is a dual-band millimetric continuum camera of 2900 Kinetic Inductance Detectors (KID), operating at $150$ and $260\,\rm{GHz}$, installed at the IRAM 30-meter telescope. We present the performance assessment of NIKA2 after one year of observation using a dedicated point-source calibration method, referred to as the \emph{baseline} method. Using a large data set acquired between January 2017 and February 2018 that span the whole range of observing elevations and atmospheric conditions encountered at the IRAM 30-m telescope, we test the stability of the performance parameters. We report an instantaneous field of view (FOV) of 6.5' in diameter, filled with an average fraction of $84\%$ and $90\%$ of valid detectors at $150$ and $260\,\rm{GHz}$, respectively. The beam pattern is characterized by a FWHM of $17.6'' \pm 0.1''$ and $11.1''\pm 0.2''$, and a beam efficiency of $77\% \pm 2\%$ and $55\% \pm 3\%$ at $150$ and $260\,\rm{GHz}$, respectively. The rms calibration uncertainties are about $3\%$ at $150\,\rm{GHz}$ and $6\%$ at $260\,\rm{GHz}$. The absolute calibration uncertainties are of $5\%$ and the systematic calibration uncertainties evaluated at the IRAM 30-m reference Winter observing conditions are below $1\%$ in both channels. The noise equivalent flux density (NEFD) at $150$ and $260\,\rm{GHz}$ are of $9 \pm 1\, \rm{mJy}\cdot s^{1/2}$ and $30 \pm 3\, \rm{mJy}\cdot s^{1/2}$. This state-of-the-art performance confers NIKA2 with map** speeds of $1388 \pm 174$ and $111 \pm 11 \,\rm{arcmin}^2\cdot \rm{mJy}^{-2}\cdot \rm{h}^{-1}$ at $150$ and $260\,\rm{GHz}$. With these unique capabilities of fast dual-band map** at high (better that 18'') angular resolution, NIKA2 is providing an unprecedented view of the millimetre Universe.
△ Less
Submitted 21 January, 2020; v1 submitted 4 October, 2019;
originally announced October 2019.
-
Increased multiplexing of superconducting microresonator arrays by post-characterization adaptation of the on-chip capacitors
Authors:
Shibo Shu,
Martino Calvo,
Johannes Goupy,
Samuel Leclercq,
Andrea Catalano,
Aurelien Bideaud,
Alessandro Monfardini,
Eduard F. C. Driessen
Abstract:
We present an interdigitated capacitor trimming technique for fine-tuning the resonance frequency of superconducting microresonators and increasing the multiplexing factor. We first measure the optical response of the array with a beam map** system to link all resonances to their physical resonators. Then a new set of resonance frequencies with uniform spacing and higher multiplexing factor is d…
▽ More
We present an interdigitated capacitor trimming technique for fine-tuning the resonance frequency of superconducting microresonators and increasing the multiplexing factor. We first measure the optical response of the array with a beam map** system to link all resonances to their physical resonators. Then a new set of resonance frequencies with uniform spacing and higher multiplexing factor is designed. We use simulations to deduce the lengths that we should trim from the capacitor fingers in order to shift the resonances to the desired frequencies. The sample is then modified using contact lithography and re-measured using the same setup. We demonstrate this technique on a 112-pixel aluminum lumped-element kinetic-inductance detector array. Before trimming, the resonance frequency deviation of this array is investigated. The variation of the inductor width plays the main role for the deviation. After trimming, the mean fractional frequency error for identified resonators is -6.4e-4, with a standard deviation of 1.8e-4. The final optical yield is increased from 70.5% to 96.7% with no observable crosstalk beyond -15 dB during map**. This technique could be applied to other photon-sensitive superconducting microresonator arrays for increasing the yield and multiplexing factor.
△ Less
Submitted 13 August, 2018; v1 submitted 11 August, 2018;
originally announced August 2018.
-
Epitaxial electrical contact to graphene on SiC
Authors:
T. Le Quang,
L. Huder,
F. Lipp Bregolin,
A. Artaud,
H. Okuno,
S. Pouget,
N. Mollard,
G. Lapertot,
A. G. M Jansen,
F. Lefloch,
E. F. C Driessen,
C. Chapelier,
V. T. Renard
Abstract:
Establishing good electrical contacts to nanoscale devices is a major issue for modern technology and contacting 2D materials is no exception to the rule. One-dimensional edge-contacts to graphene were recently shown to outperform surface contacts but the method remains difficult to scale up. We report a resist-free and scalable method to fabricate few graphene layers with electrical contacts in a…
▽ More
Establishing good electrical contacts to nanoscale devices is a major issue for modern technology and contacting 2D materials is no exception to the rule. One-dimensional edge-contacts to graphene were recently shown to outperform surface contacts but the method remains difficult to scale up. We report a resist-free and scalable method to fabricate few graphene layers with electrical contacts in a single growth step. This method derives from the discovery reported here of the growth of few graphene layers on a metallic carbide by thermal annealing of a carbide forming metallic film on SiC in high vacuum. We exploit the combined effect of edge-contact and partially-covalent surface epitaxy between graphene and the metallic carbide to fabricate devices in which low contact-resistance and Josephson effect are observed. Implementing this approach could significantly simplify the realization of large-scale graphene circuits.
△ Less
Submitted 11 July, 2017; v1 submitted 17 May, 2017;
originally announced May 2017.
-
Uniform non-stoichiometric titanium nitride thin films for improved kinetic inductance detector array
Authors:
G. Coiffard,
K-F. Schuster,
E. F. C. Driessen,
S. Pignard,
M. Calvo,
A. Catalano,
J. Goupy,
A. Monfardini
Abstract:
We describe the fabrication of homogeneous sub-stoichiometric titanium nitride films for microwave kinetic inductance detector (mKID) arrays. Using a 6 inch sputtering target and a homogeneous nitrogen inlet, the variation of the critical temperature over a 2 inch wafer was reduced to <25 %. Measurements of a 132-pixel mKID array from these films reveal a sensitivity of 16 kHz/pW in the 100 GHz ba…
▽ More
We describe the fabrication of homogeneous sub-stoichiometric titanium nitride films for microwave kinetic inductance detector (mKID) arrays. Using a 6 inch sputtering target and a homogeneous nitrogen inlet, the variation of the critical temperature over a 2 inch wafer was reduced to <25 %. Measurements of a 132-pixel mKID array from these films reveal a sensitivity of 16 kHz/pW in the 100 GHz band, comparable to the best aluminium mKIDs. We measured a noise equivalent power of NEP = 3.6e-15 W/Hz^(1/2). Finally, we describe possible routes to further improve the performance of these TiN mKID arrays.
△ Less
Submitted 7 January, 2016; v1 submitted 7 October, 2015;
originally announced October 2015.
-
The effect of magnetic field on the intrinsic detection efficiency of superconducting single-photon detectors
Authors:
J. J. Renema,
R. J. Rengelink,
I. Komen,
Q. Wang,
R. Gaudio,
K. P. M. op 't Hoog,
Z. Zhou,
D. Sahin,
A. Fiore,
P. Kes,
J. Aarts,
M. P. van Exter,
M. J. A. de Dood,
E. F. C. Driessen
Abstract:
We experimentally investigate the effect of a magnetic field on photon detection in superconducting single-photon detectors. At low fields, the effect of a magnetic field is through the direct modification of the quasiparticle density of states of the superconductor, and magnetic field and bias current are interchangable, as is expected for homogeneous dirty-limit superconductors. At the field whe…
▽ More
We experimentally investigate the effect of a magnetic field on photon detection in superconducting single-photon detectors. At low fields, the effect of a magnetic field is through the direct modification of the quasiparticle density of states of the superconductor, and magnetic field and bias current are interchangable, as is expected for homogeneous dirty-limit superconductors. At the field where a first vortex enters the detector, the effect of the magnetic field is reduced, up until the point where the critical current of the detector starts to be determined by flux flow. From this field on, increasing the magnetic field does not alter the detection of photons anymore, whereas it does still change the rate of dark counts. This result points at an intrinsic difference in dark and light counts, and also shows that no enhancement of the intrinsic detection efficiency of a straight SSPD wire is achievable in a magnetic field.
△ Less
Submitted 31 October, 2014;
originally announced October 2014.
-
Efficient and robust fiber coupling of superconducting single photon detectors
Authors:
S. N. Dorenbos,
R. W. Heeres,
E. F. C Driessen,
V. Zwiller
Abstract:
We applied a recently developed fiber coupling technique to superconducting single photon detectors (SSPDs). As the detector area of SSPDs has to be kept as small as possible, coupling to an optical fiber has been either inefficient or unreliable. Etching through the silicon substrate allows fabrication of a circularly shaped chip which self aligns to the core of a ferrule terminated fiber in a fi…
▽ More
We applied a recently developed fiber coupling technique to superconducting single photon detectors (SSPDs). As the detector area of SSPDs has to be kept as small as possible, coupling to an optical fiber has been either inefficient or unreliable. Etching through the silicon substrate allows fabrication of a circularly shaped chip which self aligns to the core of a ferrule terminated fiber in a fiber sleeve. In situ alignment at cryogenic temperatures is unnecessary and no thermal stress during cooldown, causing misalignment, is induced. We measured the quantum efficiency of these devices with an attenuated tunable broadband source. The combination of a lithographically defined chip and high precision standard telecommunication components yields near unity coupling efficiency and a system detection efficiency of 34% at a wavelength of 1200 nm. This quantum efficiency measurement is confirmed by an absolute efficiency measurement using correlated photon pairs (with $λ$ = 1064 nm) produced by spontaneous parametric down-conversion. The efficiency obtained via this method agrees well with the efficiency measured with the attenuated tunable broadband source.
△ Less
Submitted 27 September, 2011;
originally announced September 2011.
-
Impedance model for the polarization-dependent optical absorption of superconducting single-photon detectors
Authors:
E. F. C. Driessen,
F. R. Braakman,
E. M. Reiger,
S. N. Dorenbos,
V. Zwiller,
M. J. A. de Dood
Abstract:
We measured the single-photon detection efficiency of NbN superconducting single photon detectors as a function of the polarization state of the incident light for different wavelengths in the range from 488 nm to 1550 nm. The polarization contrast varies from ~5% at 488 nm to ~30% at 1550 nm, in good agreement with numerical calculations. We use an optical-impedance model to describe the absorp…
▽ More
We measured the single-photon detection efficiency of NbN superconducting single photon detectors as a function of the polarization state of the incident light for different wavelengths in the range from 488 nm to 1550 nm. The polarization contrast varies from ~5% at 488 nm to ~30% at 1550 nm, in good agreement with numerical calculations. We use an optical-impedance model to describe the absorption for polarization parallel to the wires of the detector. For lossy NbN films, the absorption can be kept constant by kee** the product of layer thickness and filling factor constant. As a consequence, we find that the maximum possible absorption is independent of filling factor. By illuminating the detector through the substrate, an absorption efficiency of ~70% can be reached for a detector on Si or GaAs, without the need for an optical cavity.
△ Less
Submitted 30 January, 2009;
originally announced January 2009.