Skip to main content

Showing 1–8 of 8 results for author: Donckt, M V

Searching in archive physics. Search in all archives.
.
  1. arXiv:1706.00222  [pdf, other

    physics.ins-det hep-ex

    Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector

    Authors: M. Dragicevic, M. Friedl, J. Hrubec, H. Steininger, A. Gädda, J. Härkönen, T. Lampén, P. Luukka, T. Peltola, E. Tuominen, E. Tuovinen, A. Winkler, P. Eerola, T. Tuuva, G. Baulieu, G. Boudoul, L. Caponetto, C. Combaret, D. Contardo, T. Dupasquier, G. Gallbit, N. Lumb, L. Mirabito, S. Perries, M. Vander Donckt , et al. (462 additional authors not shown)

    Abstract: A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator… ▽ More

    Submitted 1 June, 2017; originally announced June 2017.

    Report number: CMS-NOTE-2017-002

  2. arXiv:1506.05316  [pdf, other

    physics.ins-det hep-ex

    Construction and commissioning of a technological prototype of a high-granularity semi-digital hadronic calorimeter

    Authors: G. Baulieu, M. Bedjidian, K. Belkadhi, J. Berenguer, V. Boudry, P. Calabria, S. Callier, E. Calvo Almillo, S. Cap, L. Caponetto, C. Combaret, R. Cornat, E. Cortina Gil, B. de Callatay, F. Davin, C. de la Taille, R. Dellanegra, D. Delaunay, F. Doizon, F. Dulucq, A. Eynard, M-C. Fouz, F. Gastaldi, L. Germani, G. Grenier , et al. (21 additional authors not shown)

    Abstract: A large prototype of 1.3m3 was designed and built as a demonstrator of the semi-digital hadronic calorimeter (SDHCAL) concept proposed for the future ILC experiments. The prototype is a sampling hadronic calorimeter of 48 units. Each unit is built of an active layer made of 1m2 Glass Resistive Plate Chamber(GRPC) detector placed inside a cassette whose walls are made of stainless steel. The casset… ▽ More

    Submitted 24 October, 2015; v1 submitted 15 June, 2015; originally announced June 2015.

    Comments: 49 pages, 41 figures

  3. Trap** in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker

    Authors: W. Adam, T. Bergauer, M. Dragicevic, M. Friedl, R. Fruehwirth, M. Hoch, J. Hrubec, M. Krammer, W. Treberspurg, W. Waltenberger, S. Alderweireldt, W. Beaumont, X. Janssen, S. Luyckx, P. Van Mechelen, N. Van Remortel, A. Van Spilbeeck, P. Barria, C. Caillol, B. Clerbaux, G. De Lentdecker, D. Dobur, L. Favart, A. Grebenyuk, Th. Lenzi , et al. (663 additional authors not shown)

    Abstract: The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determi… ▽ More

    Submitted 7 May, 2015; originally announced May 2015.

    Journal ref: 2016 JINST 11 P04023

  4. arXiv:1404.6454  [pdf, other

    physics.ins-det hep-ex

    The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers

    Authors: C. Adloff, J. -J. Blaising, M. Chefdeville, C. Drancourt, R. Gaglione, N. Geffroy, Y. Karyotakis, I. Koletsou, J. Prast, G. Vouters J. Repond, J. Schlereth, L. Xia E. Baldolemar, J. Li, S. T. Park, M. Sosebee, A. P. White, J. Yu, G. Eigen, M. A. Thomson, D. R. Ward, D. Benchekroun, A. Hoummada, Y. Khoulaki J. Apostolakis, S. Arfaoui, M. Benoit , et al. (188 additional authors not shown)

    Abstract: The intrinsic time structure of hadronic showers influences the timing capability and the required integration time of hadronic calorimeters in particle physics experiments, and depends on the active medium and on the absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15 small plastic scintillator tiles read out with Silicon Photomultipliers, the time structure of showers is m… ▽ More

    Submitted 21 July, 2014; v1 submitted 25 April, 2014; originally announced April 2014.

    Comments: 24 pages including author list, 9 figures, published in JINST

    Report number: MPP-2014-147

    Journal ref: JINST 9 (2014) P07022

  5. arXiv:1311.3761  [pdf, ps, other

    physics.ins-det hep-ex

    Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter

    Authors: CALICE Collaboration, K. Francis, J. Repond, J. Schlereth, J. Smith, L. Xia, E. Baldolemar, J. Li, S. T. Park, M. Sosebee, A. P. White, J. Yu, G. Eigen, Y. Mikami, N. K. Watson, M. A. Thomson, D. R. Ward, D. Benchekroun, A. Hoummada, Y. Khoulaki, J. Apostolakis, A. Dotti, G. Folger, V. Ivantchenko, A. Ribon , et al. (169 additional authors not shown)

    Abstract: A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's performance is presented in terms of the linearity and resolution of the energy measur… ▽ More

    Submitted 11 June, 2014; v1 submitted 15 November, 2013; originally announced November 2013.

    Journal ref: Nuclear Inst. and Methods in Physics Research, A (2014), pp. 278-289

  6. Shower development of particles with momenta from 1 to 10 GeV in the CALICE Scintillator-Tungsten HCAL

    Authors: C. Adloff, J. -J. Blaising, M. Chefdeville, C. Drancourt, R. Gaglione, N. Geffroy, Y. Karyotakis, I. Koletsou, J. Prast, G. Vouters, J. Repond, J. Schlereth, J. Smith, L. Xia, E. Baldolemar, J. Li, S. T. Park, M. Sosebee, A. P. White, J. Yu, G. Eigen, M. A. Thomson, D. R. Ward, D. Benchekroun, A. Hoummada , et al. (194 additional authors not shown)

    Abstract: Lepton colliders are considered as options to complement and to extend the physics programme at the Large Hadron Collider. The Compact Linear Collider (CLIC) is an $e^+e^-$ collider under development aiming at centre-of-mass energies of up to 3 TeV. For experiments at CLIC, a hadron sampling calorimeter with tungsten absorber is proposed. Such a calorimeter provides sufficient depth to contain hig… ▽ More

    Submitted 13 January, 2014; v1 submitted 14 November, 2013; originally announced November 2013.

    Comments: 28 pages, 23 figures, 3 tables

    Journal ref: JINST 9 P01004 January 2014

  7. arXiv:1305.7027  [pdf, other

    physics.ins-det hep-ex

    Track segments in hadronic showers in a highly granular scintillator-steel hadron calorimeter

    Authors: CALICE Collaboration, C. Adloff, J. -J. Blaising, M. Chefdeville, C. Drancourt, R. Gaglione, N. Geffroy, Y. Karyotakis, I. Koletsou, J. Prast, G. Vouters, K. Francis, J. Repond, J. Schlereth, J. Smith, L. Xia, E. Baldolemar, J. Li, S. T. Park, M. Sosebee, A. P. White, J. Yu, G. Eigen, Y. Mikami, N. K. Watson , et al. (184 additional authors not shown)

    Abstract: We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic showers, providing sensitivity to the spatial structure and the details of secondary particle production in hadronic cascades. The multiplicity, length and angul… ▽ More

    Submitted 29 July, 2013; v1 submitted 30 May, 2013; originally announced May 2013.

    Comments: 27 pages, 17 figures, accepted for publication in JINST

    Report number: MPP-2013-143

  8. arXiv:1011.5969  [pdf, other

    physics.ins-det hep-ex

    Performance of Glass Resistive Plate Chambers for a high granularity semi-digital calorimeter

    Authors: M. Bedjidian, K. Belkadhi, V. Boudry, C. Combaret, D. Decotigny, E. Cortina Gil, C. de la Taille, R. Dellanegra, V. A. Gapienko, G. Grenier, C. Jauffret, R. Kieffer, M. -C. Fouz, R. Han, I. Laktineh, N. Lumb, K. Manai, S. Mannai, H. Mathez, L. Mirabito, J. Puerta Pelayo, M. Ruan, F. Schirra, N. Seguin-Moreau, W. Tromeur , et al. (3 additional authors not shown)

    Abstract: A new design of highly granular hadronic calorimeter using Glass Resistive Plate Chambers (GRPCs) with embedded electronics has been proposed for the future International Linear Collider (ILC) experiments. It features a 2-bit threshold semi-digital read-out. Several GRPC prototypes with their electronics have been successfully built and tested in pion beams. The design of these detectors is presen… ▽ More

    Submitted 30 December, 2010; v1 submitted 27 November, 2010; originally announced November 2010.

    Comments: 16 pages, 15 figures

    Journal ref: JINST 6:P02001,2011