Skip to main content

Showing 1–3 of 3 results for author: Dolenec, R

Searching in archive physics. Search in all archives.
.
  1. arXiv:2210.15331  [pdf, ps, other

    physics.ins-det hep-ex

    LAPPD operation using ToFPETv2 PETSYS ASIC

    Authors: A. Seljak, M. Bračko, R. Dolenec, P. Križan, A. Lozar, R. Pestotnik, S. Korpar

    Abstract: Single photon sensitive detectors used in high energy physics are, in some applications, required to cover areas the size of several m2, and more specifically in very strong demand with15 an ever finer imaging and timing capability for Cherenkov Ring Imaging Detector (RICH) configurations. We are evaluating the Large Area Picosecond Photo-detector (LAPPD) produced by INCOM company, as a possible c… ▽ More

    Submitted 10 January, 2023; v1 submitted 27 October, 2022; originally announced October 2022.

    Comments: Twepp 2022 workshop proceedings

  2. arXiv:1011.0352  [pdf

    physics.ins-det hep-ex

    Belle II Technical Design Report

    Authors: T. Abe, I. Adachi, K. Adamczyk, S. Ahn, H. Aihara, K. Akai, M. Aloi, L. Andricek, K. Aoki, Y. Arai, A. Arefiev, K. Arinstein, Y. Arita, D. M. Asner, V. Aulchenko, T. Aushev, T. Aziz, A. M. Bakich, V. Balagura, Y. Ban, E. Barberio, T. Barvich, K. Belous, T. Bergauer, V. Bhardwaj , et al. (387 additional authors not shown)

    Abstract: The Belle detector at the KEKB electron-positron collider has collected almost 1 billion Y(4S) events in its decade of operation. Super-KEKB, an upgrade of KEKB is under construction, to increase the luminosity by two orders of magnitude during a three-year shutdown, with an ultimate goal of 8E35 /cm^2 /s luminosity. To exploit the increased luminosity, an upgrade of the Belle detector has been pr… ▽ More

    Submitted 1 November, 2010; originally announced November 2010.

    Comments: Edited by: Z. Doležal and S. Uno

    Report number: KEK Report 2010-1

  3. Measurements of Cherenkov Photons with Silicon Photomultipliers

    Authors: S. Korpar, I. Adachi, H. Chagani, R. Dolenec, K. Hara, T. Iijima, P. Krizan, S. Nishida, R. Pestotnik, A. Stanovnik

    Abstract: A novel photon detector, the Silicon Photomultiplier (SiPM), has been tested in proximity focusing Ring Imaging Cherenkov (RICH) counters that were exposed to cosmic-ray particles in Ljubljana, and a 2 GeV electron beam at the KEK research facility. This type of RICH detector is a candidate for the particle identification detector upgrade of the BELLE detector at the KEK B-factory, for which the… ▽ More

    Submitted 2 December, 2008; originally announced December 2008.

    Comments: to appear in Proc. 11th Topical Seminar on Innovative Particle and Radiation Detectors, 1-4 October 2008, Siena, Italy; Nucl. Phys. B Proc. Suppl., in press; 5 pages, 6 figures

    Journal ref: Nucl.Phys.Proc.Suppl.197:283-287,2009