-
Results of the 2022 ECFA Early-Career Researchers Panel survey on career prospects and diversity
Authors:
Julia Allen,
Kamil Augsten,
Giovanni Benato,
Neven Blaskovic Kraljevic,
Francesco Brizioli,
Eleonora Diociaiuti,
Viktoria Hinger,
Armin Ilg,
Kateřina Jarkovská,
Katarína Křížková Gajdošová,
Magdalena Kuich,
Aleksandra Lelek,
Louis Moureaux,
Holly Pacey,
Guillaume Pietrzyk,
Géraldine Räuber,
Giulia Ripellino,
Steven Schramm,
Mariana Shopova,
Pawel Sznajder,
Abby Waldron
Abstract:
This document presents the outcomes of a comprehensive survey conducted among early career researchers (ECRs) in academic particle physics. Running from September 24, 2022, to March 3, 2023, the survey gathered responses from 759 ECRs employed in 39 countries. The study aimed to gain insights into the career prospects and experiences of ECRs while also delving into diversity and sociological aspec…
▽ More
This document presents the outcomes of a comprehensive survey conducted among early career researchers (ECRs) in academic particle physics. Running from September 24, 2022, to March 3, 2023, the survey gathered responses from 759 ECRs employed in 39 countries. The study aimed to gain insights into the career prospects and experiences of ECRs while also delving into diversity and sociological aspects within particle physics research. The survey results are presented in a manner consistent with the survey choices. The document offers insights for the particle physics community, and provides a set of recommendations for enhancing career prospects, fostering diversity, and addressing sociological dimensions within this field.
△ Less
Submitted 2 April, 2024;
originally announced April 2024.
-
Performance of a modular ton-scale pixel-readout liquid argon time projection chamber
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
T. Alves,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade
, et al. (1340 additional authors not shown)
Abstract:
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmi…
▽ More
The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements, and provide comparisons to detector simulations.
△ Less
Submitted 5 March, 2024;
originally announced March 2024.
-
Do** Liquid Argon with Xenon in ProtoDUNE Single-Phase: Effects on Scintillation Light
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar Es-sghir,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1300 additional authors not shown)
Abstract:
Do** of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first do** test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUN…
▽ More
Do** of liquid argon TPCs (LArTPCs) with a small concentration of xenon is a technique for light-shifting and facilitates the detection of the liquid argon scintillation light. In this paper, we present the results of the first do** test ever performed in a kiloton-scale LArTPC. From February to May 2020, we carried out this special run in the single-phase DUNE Far Detector prototype (ProtoDUNE-SP) at CERN, featuring 770 t of total liquid argon mass with 410 t of fiducial mass. The goal of the run was to measure the light and charge response of the detector to the addition of xenon, up to a concentration of 18.8 ppm. The main purpose was to test the possibility for reduction of non-uniformities in light collection, caused by deployment of photon detectors only within the anode planes. Light collection was analysed as a function of the xenon concentration, by using the pre-existing photon detection system (PDS) of ProtoDUNE-SP and an additional smaller set-up installed specifically for this run. In this paper we first summarize our current understanding of the argon-xenon energy transfer process and the impact of the presence of nitrogen in argon with and without xenon dopant. We then describe the key elements of ProtoDUNE-SP and the injection method deployed. Two dedicated photon detectors were able to collect the light produced by xenon and the total light. The ratio of these components was measured to be about 0.65 as 18.8 ppm of xenon were injected. We performed studies of the collection efficiency as a function of the distance between tracks and light detectors, demonstrating enhanced uniformity of response for the anode-mounted PDS. We also show that xenon do** can substantially recover light losses due to contamination of the liquid argon by nitrogen.
△ Less
Submitted 9 February, 2024; v1 submitted 2 February, 2024;
originally announced February 2024.
-
The Mu2e crystal and SiPM calorimeter: construction status
Authors:
Nikolay Atanov,
Vladimir Baranov,
Leo Borrel,
Caterina Bloise,
Julian Budagov,
Sergio Ceravol,
Franco Cervelli,
Francesco Colao,
Marco Cordelli,
Giovanni Corradi,
Yuri Davydov,
Stefano Di Falco,
Eleonora Diociaiuti,
Simone Donati,
Bertrand Echenard,
Carlo Ferrari,
Ruben Gargiulo,
Antonio Gioiosa,
Simona Giovannella,
Valerio Giusti,
Vladimir Glagolev,
Francesco Grancagnolo,
Dariush Hampai,
Fabio Happacher,
David Hitlin
, et al. (15 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab searches for the neutrino-less conversion of a negative muon into an electron, with a distinctive signature of a mono-energetic electron with energy of 104.967 MeV. The calorimeter is made of two disks of pure CsI crystals, each read out by two custom large area UV-extended SiPMs. It plays a fundamental role in providing excellent particle identification capabilitie…
▽ More
The Mu2e experiment at Fermilab searches for the neutrino-less conversion of a negative muon into an electron, with a distinctive signature of a mono-energetic electron with energy of 104.967 MeV. The calorimeter is made of two disks of pure CsI crystals, each read out by two custom large area UV-extended SiPMs. It plays a fundamental role in providing excellent particle identification capabilities and an online trigger filter while improving the track reconstruction, requiring better than 10% energy and 500 ps timing resolutions for 100 MeV electrons. In this paper, we present the status of construction and the Quality Control (QC) performed on the produced crystals and photosensors, the development of the rad-hard electronics, and the most important results of the irradiation tests. Construction of the mechanics is also reported. Status and plans for the calorimeter assembly and its first commissioning are described.
△ Less
Submitted 28 January, 2024;
originally announced January 2024.
-
The DUNE Far Detector Vertical Drift Technology, Technical Design Report
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
A. Alton,
R. Alvarez,
H. Amar,
P. Amedo,
J. Anderson,
D. A. Andrade,
C. Andreopoulos
, et al. (1304 additional authors not shown)
Abstract:
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precisi…
▽ More
DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on a near and a far detector as it aims to determine the neutrino mass hierarchy and to make high-precision measurements of the PMNS matrix parameters, including the CP-violating phase. It will also stand ready to observe supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model.
The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines the many tens-of-kiloton fiducial mass necessary for rare event searches with the sub-centimeter spatial resolution required to image those events with high precision. The addition of a photon detection system enhances physics capabilities for all DUNE physics drivers and opens prospects for further physics explorations. Given its size, the far detector will be implemented as a set of modules, with LArTPC designs that differ from one another as newer technologies arise.
In the vertical drift LArTPC design, a horizontal cathode bisects the detector, creating two stacked drift volumes in which ionization charges drift towards anodes at either the top or bottom. The anodes are composed of perforated PCB layers with conductive strips, enabling reconstruction in 3D. Light-trap-style photon detection modules are placed both on the cryostat's side walls and on the central cathode where they are optically powered.
This Technical Design Report describes in detail the technical implementations of each subsystem of this LArTPC that, together with the other far detector modules and the near detector, will enable DUNE to achieve its physics goals.
△ Less
Submitted 5 December, 2023;
originally announced December 2023.
-
Workshop on a future muon program at FNAL
Authors:
S. Corrodi,
Y. Oksuzian,
A. Edmonds,
J. Miller,
H. N. Tran,
R. Bonventre,
D. N. Brown,
F. Meot,
V. Singh,
Y. Kolomensky,
S. Tripathy,
L. Borrel,
M. Bub,
B. Echenard,
D. G. Hitlin,
H. Jafree,
S. Middleton,
R. Plestid,
F. C. Porter,
R. Y. Zhu,
L. Bottura,
E. Pinsard,
A. M. Teixeira,
C. Carelli,
D. Ambrose
, et al. (68 additional authors not shown)
Abstract:
The Snowmass report on rare processes and precision measurements recommended Mu2e-II and a next generation muon facility at Fermilab (Advanced Muon Facility) as priorities for the frontier. The Workshop on a future muon program at FNAL was held in March 2023 to discuss design studies for Mu2e-II, organizing efforts for the next generation muon facility, and identify synergies with other efforts (e…
▽ More
The Snowmass report on rare processes and precision measurements recommended Mu2e-II and a next generation muon facility at Fermilab (Advanced Muon Facility) as priorities for the frontier. The Workshop on a future muon program at FNAL was held in March 2023 to discuss design studies for Mu2e-II, organizing efforts for the next generation muon facility, and identify synergies with other efforts (e.g., muon collider). Topics included high-power targetry, status of R&D for Mu2e-II, development of compressor rings, FFA and concepts for muon experiments (conversion, decays, muonium and other opportunities) at AMF. This document summarizes the workshop discussions with a focus on future R&D tasks needed to realize these concepts.
△ Less
Submitted 11 September, 2023;
originally announced September 2023.
-
Beam test, simulation, and performance evaluation of PbF$_2$ and PWO-UF crystals with SiPM readout for a semi-homogeneous calorimeter prototype with longitudinal segmentation
Authors:
C. Cantone,
S. Carsi,
S. Ceravolo,
E. Di Meco,
E. Diociaiuti,
I. Frank,
S. Kholodenko,
S. Martellotti,
M. Mirra,
P. Monti-Guarnieri,
M. Moulson,
D. Paesani,
M. Prest,
M. Romagnoni,
I. Sarra,
F. Sgarbossa,
M. Soldani,
E. Vallazza
Abstract:
Crilin (Crystal Calorimeter with Longitudinal Information) is a semi-homogeneous, longitudinally segmented electromagnetic calorimeter based on high-$Z$, ultra-fast crystals with UV-extended SiPM readout. The Crilin design has been proposed as a candidate solution for both a future Muon Collider barrel ECAL and for the Small Angle Calorimeter of the HIKE experiment. As a part of the Crilin develop…
▽ More
Crilin (Crystal Calorimeter with Longitudinal Information) is a semi-homogeneous, longitudinally segmented electromagnetic calorimeter based on high-$Z$, ultra-fast crystals with UV-extended SiPM readout. The Crilin design has been proposed as a candidate solution for both a future Muon Collider barrel ECAL and for the Small Angle Calorimeter of the HIKE experiment. As a part of the Crilin development program, we have carried out beam tests of small ($10\times10\times40$~mm$^3$) lead fluoride (PbF$_2$) and ultra-fast lead tungstate (PbWO$_4$, PWO) crystals with 120~GeV electrons at the CERN SPS to study the light yield, timing response, and systematics of light collection with a proposed readout scheme. For a single crystal of PbF$_2$, corresponding to a single Crilin cell, a time resolution of better than 25~ps is obtained for $>$3 GeV of deposited energy. For a single cell of \pwo, a time resolution of better than 45~ps is obtained for the same range of deposited energy. This timing performance fully satisfies the design requirements for the Muon Collider and HIKE experiments. Further optimizations of the readout scheme and crystal surface preparation are expected to bring further improvements.
△ Less
Submitted 2 August, 2023;
originally announced August 2023.
-
Towards a Muon Collider
Authors:
Carlotta Accettura,
Dean Adams,
Rohit Agarwal,
Claudia Ahdida,
Chiara Aimè,
Nicola Amapane,
David Amorim,
Paolo Andreetto,
Fabio Anulli,
Robert Appleby,
Artur Apresyan,
Aram Apyan,
Sergey Arsenyev,
Pouya Asadi,
Mohammed Attia Mahmoud,
Aleksandr Azatov,
John Back,
Lorenzo Balconi,
Laura Bandiera,
Roger Barlow,
Nazar Bartosik,
Emanuela Barzi,
Fabian Batsch,
Matteo Bauce,
J. Scott Berg
, et al. (272 additional authors not shown)
Abstract:
A muon collider would enable the big jump ahead in energy reach that is needed for a fruitful exploration of fundamental interactions. The challenges of producing muon collisions at high luminosity and 10 TeV centre of mass energy are being investigated by the recently-formed International Muon Collider Collaboration. This Review summarises the status and the recent advances on muon colliders desi…
▽ More
A muon collider would enable the big jump ahead in energy reach that is needed for a fruitful exploration of fundamental interactions. The challenges of producing muon collisions at high luminosity and 10 TeV centre of mass energy are being investigated by the recently-formed International Muon Collider Collaboration. This Review summarises the status and the recent advances on muon colliders design, physics and detector studies. The aim is to provide a global perspective of the field and to outline directions for future work.
△ Less
Submitted 27 November, 2023; v1 submitted 15 March, 2023;
originally announced March 2023.
-
The ECFA Early Career Researcher's Panel: composition, structure, and activities, 2021 -- 2022
Authors:
ECFA Early-Career Researcher Panel,
:,
Andrei Alexandru Geanta,
Chiara Amendola,
Liliana Apolinario,
Jan-Hendrik Arling,
Adi Ashkenazi,
Kamil Augsten,
Emanuele Bagnaschi,
Evelin Bakos,
Liron Barak,
Diogo Bastos,
Giovanni Benato,
Bugra Bilin,
Neven Blaskovic Kraljevic,
Lydia Brenner,
Francesco Brizioli,
Antoine Camper,
Alessandra Camplani,
Xabier Cid Vidal,
Hüseyin Dag,
Flavia de Almeida Dias,
Jordy Degens,
Eleonora Diociaiuti,
Laurent Dufour
, et al. (52 additional authors not shown)
Abstract:
The European Committee for Future Accelerators (ECFA) Early Career Researcher's (ECR) panel, which represents the interests of the ECR community to ECFA, officially began its activities in January 2021. In the first two years, the panel has defined its own internal structure, responded to ECFA requests for feedback, and launched its own initiatives to better understand and support the diverse inte…
▽ More
The European Committee for Future Accelerators (ECFA) Early Career Researcher's (ECR) panel, which represents the interests of the ECR community to ECFA, officially began its activities in January 2021. In the first two years, the panel has defined its own internal structure, responded to ECFA requests for feedback, and launched its own initiatives to better understand and support the diverse interests of early career researchers. This report summarises the panel composition and structure, as well as the different activities the panel has been involved with during the first two years of its existence.
△ Less
Submitted 20 December, 2022;
originally announced December 2022.
-
Highly-parallelized simulation of a pixelated LArTPC on a GPU
Authors:
DUNE Collaboration,
A. Abed Abud,
B. Abi,
R. Acciarri,
M. A. Acero,
M. R. Adames,
G. Adamov,
M. Adamowski,
D. Adams,
M. Adinolfi,
C. Adriano,
A. Aduszkiewicz,
J. Aguilar,
Z. Ahmad,
J. Ahmed,
B. Aimard,
F. Akbar,
K. Allison,
S. Alonso Monsalve,
M. Alrashed,
C. Alt,
A. Alton,
R. Alvarez,
P. Amedo,
J. Anderson
, et al. (1282 additional authors not shown)
Abstract:
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we pr…
▽ More
The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we present the first implementation of a full microphysical simulator of a liquid argon time projection chamber (LArTPC) equipped with light readout and pixelated charge readout, developed for the DUNE Near Detector. The software is implemented with an end-to-end set of GPU-optimized algorithms. The algorithms have been written in Python and translated into CUDA kernels using Numba, a just-in-time compiler for a subset of Python and NumPy instructions. The GPU implementation achieves a speed up of four orders of magnitude compared with the equivalent CPU version. The simulation of the current induced on $10^3$ pixels takes around 1 ms on the GPU, compared with approximately 10 s on the CPU. The results of the simulation are compared against data from a pixel-readout LArTPC prototype.
△ Less
Submitted 28 February, 2023; v1 submitted 19 December, 2022;
originally announced December 2022.
-
An automated QC Station for the Calibration of the Mu2e Calorimeter Readout Units
Authors:
E. Sanzani,
C. Bloise,
S. Ceravolo,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
S. Di Falco,
E. Diociaiuti,
S. Donati,
C. Ferrari,
R. Gargiulo,
A. Gioiosa,
S. Giovannella,
V. Giusti,
D. Hampai,
F. Happacher,
M. Martini,
S. Miscetti,
L. Morescalchi,
D. Paesani,
D. Pasciuto,
E. Pedreschi,
F. Raffaelli,
I. Sarra
, et al. (3 additional authors not shown)
Abstract:
The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in operation an automated Quality Control (QC) station. Gain, collected charge and photon detection efficiency are evaluated for each unit. In this paper, the QC Station is presented, in its hardware and softwa…
▽ More
The Mu2e calorimeter will employ Readout Units, each made of two Silicon Photomultipliers arrays and two Front End Electronics boards. To calibrate them, we have designed, assembled and put in operation an automated Quality Control (QC) station. Gain, collected charge and photon detection efficiency are evaluated for each unit. In this paper, the QC Station is presented, in its hardware and software aspects, summarizing also the tests performed on the ROUs and the first measurement results.
△ Less
Submitted 26 September, 2022;
originally announced September 2022.
-
Crilin: A CRystal calorImeter with Longitudinal InformatioN for a future Muon Collider
Authors:
S. Ceravolo,
F. Colao,
C. Curatolo,
E. Di Meco,
E. Diociaiuti,
D. Lucchesi,
D. Paesani,
N. Pastrone,
A. Saputi,
I. Sarra,
L. Sestini,
D. Tagnani
Abstract:
The measurement of physics processes at new energy frontier experiments requires excellent spatial, time, and energy resolutions to resolve the structure of collimated high-energy jets. In a future Muon Collider, the beam-induced backgrounds (BIB) represent the main challenge in the design of the detectors and of the event reconstruction algorithms. The technology and the design of the calorimeter…
▽ More
The measurement of physics processes at new energy frontier experiments requires excellent spatial, time, and energy resolutions to resolve the structure of collimated high-energy jets. In a future Muon Collider, the beam-induced backgrounds (BIB) represent the main challenge in the design of the detectors and of the event reconstruction algorithms. The technology and the design of the calorimeters should be chosen to reduce the effect of the BIB, while kee** good physics performance. Several requirements can be inferred: i) high granularity to reduce the overlap of BIB particles in the same calorimeter cell; ii) excellent timing (of the order of 100 ps) to reduce the out-of-time component of the BIB; iii) longitudinal segmentation to distinguish the signal showers from the fake showers produced by the BIB; iv) good energy resolution (less than 10%/sqrt(E)) to obtain good physics performance, as has been already demonstrated for conceptual particle flow calorimeters. Our proposal consists of a semi-homogeneous electromagnetic calorimeter based on Lead Fluoride Crystals (PbF2) readout by surface-mount UV-extended Silicon Photomultipliers (SiPMs): the Crilin calorimeter. In this paper, the performances of the Crilin calorimeter in the Muon Collider framework for hadron jets reconstruction have been analyzed. We report the single components characterizations together with the development of a small-scale prototype, consisting of 2 layers of 3x3 crystals each.
△ Less
Submitted 7 September, 2022; v1 submitted 12 June, 2022;
originally announced June 2022.
-
A Measurement of Proton, Deuteron, Triton and Alpha Particle Emission after Nuclear Muon Capture on Al, Si and Ti with the AlCap Experiment
Authors:
AlCap Collaboration,
Andrew Edmonds,
John Quirk,
Ming-Liang Wong,
Damien Alexander,
Robert H. Bernstein,
Aji Daniel,
Eleonora Diociaiuti,
Raffaella Donghia,
Ewen L. Gillies,
Ed V. Hungerford,
Peter Kammel,
Benjamin E. Krikler,
Yoshitaka Kuno,
Mark Lancaster,
R. Phillip Litchfield,
James P. Miller,
Anthony Palladino,
Jose Repond,
Akira Sato,
Ivano Sarra,
Stefano Roberto Soleti,
Vladimir Tishchenko,
Nam H. Tran,
Yoshi Uchida
, et al. (2 additional authors not shown)
Abstract:
Heavy charged particles after nuclear muon capture are an important nuclear physics background to the muon-to-electron conversion experiments Mu2e and COMET, which will search for charged lepton flavor violation at an unprecedented level of sensitivity. The AlCap experiment measured the yield and energy spectra of protons, deuterons, tritons, and alpha particles emitted after the nuclear capture o…
▽ More
Heavy charged particles after nuclear muon capture are an important nuclear physics background to the muon-to-electron conversion experiments Mu2e and COMET, which will search for charged lepton flavor violation at an unprecedented level of sensitivity. The AlCap experiment measured the yield and energy spectra of protons, deuterons, tritons, and alpha particles emitted after the nuclear capture of muons stopped in Al, Si, and Ti in the low energy range relevant for the muon-to-electron conversion experiments. Individual charged particle types were identified in layered silicon detector packages and their initial energy distributions were unfolded from the observed energy spectra. Detailed information on yields and energy spectra for all observed nuclei are presented in the paper.
△ Less
Submitted 1 April, 2022; v1 submitted 19 October, 2021;
originally announced October 2021.
-
Radiation study of Lead Fluoride crystals
Authors:
A. Cemmi,
A. Colangeli,
B. D'orsi,
I. Di Sarcina,
E. Diociaiuti,
S. Fiore,
D. Paesani,
M. Pillon,
A. Saputi,
I. Sarra,
D. Tagnani
Abstract:
Lead fluoride (PbF$_2$) crystals represent an excellent and relatively innovative choice for high resolution electromagnetic calorimeters with high granularity and fast timing for high intensity environments. For this reason two PbF$_2$ crystals, sized $5\times 5 \times 40 $ mm$^3$, were irradiated with $^{60}$Co photons up to $\sim 4$ Mrad and with 14 MeV neutrons up to a $10^{13}$ n/cm$^2$ total…
▽ More
Lead fluoride (PbF$_2$) crystals represent an excellent and relatively innovative choice for high resolution electromagnetic calorimeters with high granularity and fast timing for high intensity environments. For this reason two PbF$_2$ crystals, sized $5\times 5 \times 40 $ mm$^3$, were irradiated with $^{60}$Co photons up to $\sim 4$ Mrad and with 14 MeV neutrons up to a $10^{13}$ n/cm$^2$ total fluence. Their loss in transmittance was evaluated at different steps of the photon and neutron irradiation campaign, resulting in a total of 30% loss above 350 nm. With crystals always kept in dark conditions, natural and thermal annealing, as well as optical bleaching with 400 nm light, were performed on the irradiated specimens, resulting in a partial recovery of their original optical characteristics.
△ Less
Submitted 14 April, 2022; v1 submitted 26 July, 2021;
originally announced July 2021.
-
Results of the 2021 ECFA Early-Career Researcher Survey on Training in Instrumentation
Authors:
ECFA Early-Career Researcher Panel,
:,
Anamika Aggarwal,
Chiara Amendola,
Liliana Apolinario,
Jan-Hendrik Arling,
Adi Ashkenazi,
Kamil Augsten,
Julien Baglio,
Evelin Bakos,
Liron Barak,
Diogo Bastos,
Bugra Bilin,
Silvia Biondi,
Neven Blaskovic Kraljevic,
Lydia Brenner,
Francesco Brizioli,
Antoine Camper,
Alessandra Camplani,
Xabier Cid Vidal,
Hüseyin Dag,
Flavia de Almeida Dias,
Eleonora Diociaiuti,
Lennart van Doremalen,
Katherine Dunne
, et al. (52 additional authors not shown)
Abstract:
The European Committee for Future Accelerators (ECFA) Early-Career Researchers (ECR) Panel was invited by the ECFA Detector R&D Roadmap conveners to collect feedback from the European ECR community. A working group within the ECFA ECR panel held a Townhall Meeting to get first input, and then designed and broadly circulated a detailed survey to gather feedback from the larger ECR community. A tota…
▽ More
The European Committee for Future Accelerators (ECFA) Early-Career Researchers (ECR) Panel was invited by the ECFA Detector R&D Roadmap conveners to collect feedback from the European ECR community. A working group within the ECFA ECR panel held a Townhall Meeting to get first input, and then designed and broadly circulated a detailed survey to gather feedback from the larger ECR community. A total of 473 responses to this survey were received, providing a useful overview of the experiences of ECRs in instrumentation training and related topics. This report summarises the feedback received, and is intended to serve as an input to the ECFA Detector R&D Roadmap process.
△ Less
Submitted 1 July, 2021;
originally announced July 2021.
-
Mu2e calorimeter readout system
Authors:
N. Atanov,
V. Baranov,
L. Baldini,
J. Budagov,
D. Caiulo,
F. Cei,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
Yu. I. Davydov,
F. D'Errico,
S. Di Falco,
E. Diociaiuti,
S. Donati,
R. Donghia,
B. Echenard,
S. Faetti,
S. Giovannella,
S. Giudici,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
L. Lazzeri
, et al. (21 additional authors not shown)
Abstract:
The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: 1) the front-end module hosts the sha** amplifier and the high voltage linear regulator; since one front-end module is interfaced to o…
▽ More
The Mu2e electromagnetic calorimeter is made of two disks of un-doped parallelepiped CsI crystals readout by SiPM. There are 674 crystals in one disk and each crystal is readout by an array of two SiPM. The readout electronics is composed of two types of modules: 1) the front-end module hosts the sha** amplifier and the high voltage linear regulator; since one front-end module is interfaced to one SiPM, a total of 2696 modules are needed for the entire calorimeter; 2) a waveform digitizer provides a further level of amplification and digitizes the SiPM signal at the sampling frequency of $200\ \text{M}\text{Hz}$ with 12-bits ADC resolution; since one board digitizes the data received from 20 SiPMs, a total of 136 boards are needed. The readout system operational conditions are hostile: ionization dose of $20\ \text{krads}$, neutron flux of $10^{12}\ \mathrm{n}(1\ \text{MeVeq})/\text{cm}^2$, magnetic field of $1\ \text{T}$ and in vacuum level of $10^{-4}\ \text{Torr}$. A description of the readout system and qualification tests is reported.
△ Less
Submitted 9 July, 2019;
originally announced July 2019.
-
The Mu2e calorimeter: quality assurance of production crystals and SiPMs
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
D. Caiulo,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
Yu. I. Davydov,
S. Di Falco,
E. Diociaiuti,
S. Donati,
R. Donghia,
B. Echenard,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat,
E. Pedreschi
, et al. (12 additional authors not shown)
Abstract:
The Mu2e calorimeter is composed of two disks each containing 1348 pure CsI crystals, each crystal read out by two arrays of 6x6 mm2 monolithic SiPMs. The experimental requirements have been translated in a series of technical specifications for both crystals and SiPMs. Quality assurance tests, on first crystal and then SiPM production batches, confirm the performances of preproduction samples pre…
▽ More
The Mu2e calorimeter is composed of two disks each containing 1348 pure CsI crystals, each crystal read out by two arrays of 6x6 mm2 monolithic SiPMs. The experimental requirements have been translated in a series of technical specifications for both crystals and SiPMs. Quality assurance tests, on first crystal and then SiPM production batches, confirm the performances of preproduction samples previously assembled in a calorimeter prototype and tested with an electron beam. The production yield is sufficient to allow the construction of a calorimeter of the required quality in the expected times.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.
-
An induced annealing technique for SiPMs neutron radiation damage
Authors:
M. Cordelli,
E. Diociaiuti,
A. Ferrari,
S. Miscetti,
S. Muller,
G. Pezzullo,
I. Sarra
Abstract:
The use of Silicon Photo-Multipliers(SiPMs)has become popular in the design of High Energy Physics experimental apparatus with a growing interest for their application in detector area where a significant amount of non-ionising dose is delivered. For these devices, the main effect caused by the neutron fluence is a linear increase of the leakage current. In this paper, we present a technique that…
▽ More
The use of Silicon Photo-Multipliers(SiPMs)has become popular in the design of High Energy Physics experimental apparatus with a growing interest for their application in detector area where a significant amount of non-ionising dose is delivered. For these devices, the main effect caused by the neutron fluence is a linear increase of the leakage current. In this paper, we present a technique that provides a partial recovery of the neutron damage on SiPMs by means of an Electrical Induced Annealing. Tests were performed, at the temperature of 20C, on a sample of three SiPM arrays (2x3) of 6 mm^2 cells with 50 um pixel sizes: two from Hamamatsu and one from SensL. These SiPMs have been exposed to neutrons generated by the Elbe Positron Source facility (Dresden), up to a total fluence of 8x10^11 n1MeV-eq/cm^2. Our techniques allowed to reduced the leakage current of a factor ranging between 15-20 depending on the overbias used and the SiPM vendor. Because, during the process the SiPM current can reach O(100 mA), the sensors need to be operated in a condition that provides thermal dissipation. Indeed, caution must be used when applying this kind of procedures on the SiPMs, because it may damage permanently the device itself.
△ Less
Submitted 6 December, 2021; v1 submitted 25 April, 2018;
originally announced April 2018.
-
Quality Assurance on Un-Doped CsI Crystals for the Mu2e Experiment
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
Yu. I. Davydov,
V. Glagolev,
V. Tereshchenko,
Z. Usubov,
F. Cervelli,
S. Di Falco,
S. Donati,
L. Morescalchi,
E. Pedreschi,
G. Pezzullo,
F. Raffaelli,
F. Spinella,
F. Colao,
M. Cordelli,
G. Corradi,
E. Diociaiuti,
R. Donghia,
S. Giovannella,
F. Happacher,
M. Martini,
S. Miscetti,
M. Ricci
, et al. (12 additional authors not shown)
Abstract:
The Mu2e experiment is constructing a calorimeter consisting of 1,348 undoped CsI crystals in two disks. Each crystal has a dimension of 34 x 34 x 200 mm, and is readout by a large area silicon PMT array. A series of technical specifications was defined according to physics requirements. Preproduction CsI crystals were procured from three firms: Amcrys, Saint-Gobain and Shanghai Institute of Ceram…
▽ More
The Mu2e experiment is constructing a calorimeter consisting of 1,348 undoped CsI crystals in two disks. Each crystal has a dimension of 34 x 34 x 200 mm, and is readout by a large area silicon PMT array. A series of technical specifications was defined according to physics requirements. Preproduction CsI crystals were procured from three firms: Amcrys, Saint-Gobain and Shanghai Institute of Ceramics. We report the quality assurance on crystal's scintillation properties and their radiation hardness against ionization dose and neutrons. With a fast decay time of 30 ns and a light output of more than 100 p.e./MeV measured with a bi-alkali PMT, undoped CsI crystals provide a cost-effective solution for the Mu2e experiment.
△ Less
Submitted 21 February, 2018;
originally announced February 2018.
-
Results of the first user program on the Homogenous Thermal Neutron Source HOTNES (ENEA / INFN)
Authors:
A. Sperduti,
M. Angelone,
R. Bedogni,
G. Claps,
E. Diociaiuti,
C. Domingo,
R. Donghia,
S. Giovannella,
J. M. Gomez-Ros,
L. Irazola-Rosales,
S. Loreti,
V. Monti,
S. Miscetti,
F. Murtas,
G. Pagano,
M. Pillon,
R. Pilotti,
A. Pola,
M. Romero-Expósito,
F. Sánchez-Doblado,
O. Sans-Planell,
A. Scherillo,
E. Soldani,
M. Treccani,
A. Pietropaolo
Abstract:
The HOmogeneous Thermal NEutron Source (HOTNES) is a new type of thermal neutron irradiation assembly developed by the ENEA-INFN collaboration. The facility is fully characterized in terms of neutron field and dosimetric quantities, by either computational and experimental methods. This paper reports the results of the first "HOTNES users program", carried out in 2016, and covering a variety of th…
▽ More
The HOmogeneous Thermal NEutron Source (HOTNES) is a new type of thermal neutron irradiation assembly developed by the ENEA-INFN collaboration. The facility is fully characterized in terms of neutron field and dosimetric quantities, by either computational and experimental methods. This paper reports the results of the first "HOTNES users program", carried out in 2016, and covering a variety of thermal neutron active detectors such as scintillators, solid-state, single crystal diamond and gaseous detectors.
△ Less
Submitted 22 February, 2018;
originally announced February 2018.
-
Design and status of the Mu2e crystal calorimeter
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
Yu. I. Davydov,
V. Glagolev,
V. Tereshchenko,
Z. Usubov,
F. Cervelli,
S. Di Falco,
S. Donati,
L. Morescalchi,
E. Pedreschi,
G. Pezzullo,
F. Raffaelli,
F. Spinella,
F. Colao,
M. Cordelli,
G. Corradi,
E. Diociaiuti,
R. Donghia,
S. Giovannella,
F. Happacher,
M. Martini,
S. Miscetti,
M. Ricci
, et al. (10 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab searches for the charged-lepton flavour violating (CLFV) conversion of a negative muon into an electron in the field of an aluminum nucleus, with a distinctive signature of a mono-energetic electron of energy slightly below the muon rest mass (104.967 MeV). The Mu2e goal is to improve by four orders of magnitude the search sensitivity with respect to the previous ex…
▽ More
The Mu2e experiment at Fermilab searches for the charged-lepton flavour violating (CLFV) conversion of a negative muon into an electron in the field of an aluminum nucleus, with a distinctive signature of a mono-energetic electron of energy slightly below the muon rest mass (104.967 MeV). The Mu2e goal is to improve by four orders of magnitude the search sensitivity with respect to the previous experiments. Any observation of a CLFV signal will be a clear indication of new physics. The Mu2e detector is composed of a tracker, an electro- magnetic calorimeter and an external veto for cosmic rays surrounding the solenoid. The calorimeter plays an important role in providing particle identification capabilities, a fast online trigger filter, a seed for track reconstruction while working in vacuum, in the presence of 1 T axial magnetic field and in an harsh radiation environment. The calorimeter requirements are to provide a large acceptance for 100 MeV electrons and reach at these energies: (a) a time resolution better than 0.5 ns; (b) an energy resolution < 10% and (c) a position resolution of 1 cm. The calorimeter design consists of two disks, each one made of 674 undoped CsI crystals read by two large area arrays of UV-extended SiPMs. We report here the construction and test of the Module-0 prototype. The Module-0 has been exposed to an electron beam in the energy range around 100 MeV at the Beam Test Facility in Frascati. Preliminary results of timing and energy resolution at normal incidence are shown. A discussion of the technical aspects of the calorimeter engineering is also reported in this paper.
△ Less
Submitted 18 February, 2018;
originally announced February 2018.
-
The Mu2e Calorimeter Final Technical Design Report
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
S. Ceravolo,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
E. Dane,
Y. Davydov,
S. Di Falco,
S. Donati,
E. Diociaiuti,
R. Donghia,
B. Echenard,
K. Flood,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi
, et al. (15 additional authors not shown)
Abstract:
Since the first version of the Mu2e TDR released at the beginning of 2015, the Mu2e Calorimeter system has undergone a long list of changes to arrive to its final design. These changes were primarily caused by two reasons: (i) the technology choice between the TDR proposed solution of BaF2 crystals readout with solar blind Avalanche Photodiodes (APDs) and the backup option of CsI crystals readout…
▽ More
Since the first version of the Mu2e TDR released at the beginning of 2015, the Mu2e Calorimeter system has undergone a long list of changes to arrive to its final design. These changes were primarily caused by two reasons: (i) the technology choice between the TDR proposed solution of BaF2 crystals readout with solar blind Avalanche Photodiodes (APDs) and the backup option of CsI crystals readout with Silicon Photomultipliers (SiPM) has been completed and (ii) the channels numbering, the mechanical system and the readout electronics were substantially modified while proceeding with engineering towards the final project. This document updates the description of the calorimeter system adding the most recent engineering drawings and tecnical progresses.
△ Less
Submitted 18 February, 2018;
originally announced February 2018.
-
Expression of Interest for Evolution of the Mu2e Experiment
Authors:
F. Abusalma,
D. Ambrose,
A. Artikov,
R. Bernstein,
G. C. Blazey,
C. Bloise,
S. Boi,
T. Bolton,
J. Bono,
R. Bonventre,
D. Bowring,
D. Brown,
D. Brown,
K. Byrum,
M. Campbell,
J. -F. Caron,
F. Cervelli,
D. Chokheli,
K. Ciampa,
R. Ciolini,
R. Coleman,
D. Cronin-Hennessy,
R. Culbertson,
M. A. Cummings,
A. Daniel
, et al. (103 additional authors not shown)
Abstract:
We propose an evolution of the Mu2e experiment, called Mu2e-II, that would leverage advances in detector technology and utilize the increased proton intensity provided by the Fermilab PIP-II upgrade to improve the sensitivity for neutrinoless muon-to-electron conversion by one order of magnitude beyond the Mu2e experiment, providing the deepest probe of charged lepton flavor violation in the fores…
▽ More
We propose an evolution of the Mu2e experiment, called Mu2e-II, that would leverage advances in detector technology and utilize the increased proton intensity provided by the Fermilab PIP-II upgrade to improve the sensitivity for neutrinoless muon-to-electron conversion by one order of magnitude beyond the Mu2e experiment, providing the deepest probe of charged lepton flavor violation in the foreseeable future. Mu2e-II will use as much of the Mu2e infrastructure as possible, providing, where required, improvements to the Mu2e apparatus to accommodate the increased beam intensity and cope with the accompanying increase in backgrounds.
△ Less
Submitted 7 February, 2018;
originally announced February 2018.
-
The Mu2e crystal calorimeter
Authors:
N. Atanov,
J. Budagov,
F. Cervelli,
F. Colao,
Y Davidov,
S. Di Falco,
E. Diociaiuti,
S. Donati,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat,
E. Pedreschi,
G. Pezzullo,
F. Porter,
A. Saputi,
I. Sarra,
F. Spinella,
G. Tassielli
Abstract:
The Mu2e Experiment at Fermilab will search for coherent, neutrino-less conversion of negative muons into electrons in the field of an Aluminum nucleus, $μ^- + Al \to e^- +Al$. Data collection start is planned for the end of 2021.
The dynamics of such charged lepton flavour violating (CLFV) process is well modelled by a two-body decay, resulting in a mono-energetic electron with an energy slight…
▽ More
The Mu2e Experiment at Fermilab will search for coherent, neutrino-less conversion of negative muons into electrons in the field of an Aluminum nucleus, $μ^- + Al \to e^- +Al$. Data collection start is planned for the end of 2021.
The dynamics of such charged lepton flavour violating (CLFV) process is well modelled by a two-body decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass. If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between the conversion and the capture rates
%\convrate of $\leq 6\ \times\ 10^{-17}$ (@ 90$\%$ C.L.). R$_{μe} = \frac{μ^- + A(Z,N) \to e^- +A(Z,N)}{μ^- + A(Z,N) \to ν_μ ^- +A(Z-1,N)} $ of $\leq 6\ \times\ 10^{-17}$ (@ 90$\%$ C.L.).
This will improve the current limit of four order of magnitudes with respect to the previous best experiment.
Mu2e complements and extends the current search for $μ\to e γ$ decay at MEG as well as the direct searches for new physics at the LHC. The observation of such CLFV process could be clear evidence for New Physics beyond the Standard Model. Given its sensitivity, Mu2e will be able to probe New Physics at a scale inaccessible to direct searches at either present or planned high energy colliders. To search for the muon conversion process, a very intense pulsed beam of negative muons ($\sim 10^{10} μ/$ sec) is stopped on an Aluminum target inside a very long solenoid where the detector is also located. The Mu2e detector is composed of a straw tube tracker and a CsI crystals electromagnetic calorimeter. An overview of the physics motivations for Mu2e, the current status of the experiment and the required performances and design details of the calorimeter are presented.
△ Less
Submitted 30 January, 2018;
originally announced January 2018.
-
Design, status and perspective of the Mu2e crystal calorimeter
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
F. Cervelli,
F. Colao,
E. Diociaiuti,
M. Cordelli,
G. Corradi,
E. Danè,
Yu. Davydov,
S. Donati,
R. Donghia,
S. Di Falco,
B. Echenard,
L. Morescalchi,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat
, et al. (11 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-less $μ\to e$ coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about $2.5\cdot 10^{-17}$ that corresponds to four orders of magnitude improvements with respect to the current best limit. The detector system consists of a straw tube tracker an…
▽ More
The Mu2e experiment at Fermilab will search for the charged lepton flavor violating process of neutrino-less $μ\to e$ coherent conversion in the field of an aluminum nucleus. Mu2e will reach a single event sensitivity of about $2.5\cdot 10^{-17}$ that corresponds to four orders of magnitude improvements with respect to the current best limit. The detector system consists of a straw tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon Photomultipliers. The calorimeter was designed to be operable in a harsh environment where about 10 krad/year will be delivered in the hottest region and work in presence of 1 T magnetic field. The calorimeter role is to perform $μ$/e separation to suppress cosmic muons mimiking the signal, while providing a high level trigger and a seeding the track search in the tracker. In this paper we present the calorimeter design and the latest R$\&$D results.
△ Less
Submitted 18 April, 2018; v1 submitted 9 January, 2018;
originally announced January 2018.
-
The Mu2e undoped CsI crystal calorimeter
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
Yu. I. Davydov,
S. Di Falco,
E. Diociaiuti,
S. Donati,
R. Donghia,
B. Echenard,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat,
E. Pedreschi,
G. Pezzullo
, et al. (10 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigg…
▽ More
The Mu2e experiment at Fermilab will search for Charged Lepton Flavor Violating conversion of a muon to an electron in an atomic field. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external system, surrounding the solenoid, to veto cosmic rays. The calorimeter plays an important role to provide: a) excellent particle identification capabilities; b) a fast trigger filter; c) an easier tracker track reconstruction. Two disks, located downstream of the tracker, contain 674 pure CsI crystals each. Each crystal is read out by two arrays of UV-extended SiPMs. The choice of the crystals and SiPMs has been finalized after a thorough test campaign. A first small scale prototype consisting of 51 crystals and 102 SiPM arrays has been exposed to an electron beam at the BTF (Beam Test Facility) in Frascati. Although the readout electronics were not the final, results show that the current design is able to meet the timing and energy resolution required by the Mu2e experiment.
△ Less
Submitted 22 February, 2018; v1 submitted 7 January, 2018;
originally announced January 2018.
-
Pre-Production and Quality Assurance of the Mu2e Calorimeter Silicon Photomultipliers
Authors:
M. Cordelli,
F. Cervelli,
E. Diociaiuti,
S. Donati,
R. Donghia,
S. Di Falco,
A. Ferrari,
S. Giovannella,
F. Happacher,
M. Martini,
L. Morescalchi,
S. Miscetti,
S. Muller,
E. Pedreschi,
G. Pezzullo,
I. Sarra,
F. Spinella
Abstract:
The Mu2e electromagnetic calorimeter has to provide precise information on energy, time and position for $\sim$100 MeV electrons. It is composed of 1348 un-doped CsI crystals, each coupled to two large area Silicon Photomultipliers (SiPMs). A modular and custom SiPM layout consisting of a 3$\times$2 array of 6$\times$6 mm$^2$ UV-extended monolithic SiPMs has been developed to fulfill the Mu2e calo…
▽ More
The Mu2e electromagnetic calorimeter has to provide precise information on energy, time and position for $\sim$100 MeV electrons. It is composed of 1348 un-doped CsI crystals, each coupled to two large area Silicon Photomultipliers (SiPMs). A modular and custom SiPM layout consisting of a 3$\times$2 array of 6$\times$6 mm$^2$ UV-extended monolithic SiPMs has been developed to fulfill the Mu2e calorimeter requirements and a pre-production of 150 prototypes has been procured by three international firms (Hamamatsu, SensL and Advansid). A detailed quality assurance process has been carried out on this first batch of photosensors: the breakdown voltage, the gain, the quenching time, the dark current and the Photon Detection Efficiency (PDE) have been determined for each monolithic cell of each SiPMs array. One sample for each vendor has been exposed to a neutron fluency up to $\sim$8.5~$\times$~10$^{11}$ 1 MeV (Si) eq. n/cm$^{2}$ and a linear increase of the dark current up to tens of mA has been observed. Others 5 samples for each vendor have undergone an accelerated aging in order to verify a Mean Time To Failure (MTTF) higher than $\sim$10$^{6}$ hours.
△ Less
Submitted 13 December, 2017;
originally announced December 2017.
-
Quality Assurance on a custom SiPMs array for the Mu2e experiment
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
Yu. I. Davydov,
V. Glagolev,
V. Tereshchenko,
Z. Usubov,
F. Cervelli,
S. Di Falco,
S. Donati,
L. Morescalchi,
E. Pedreschi,
G. Pezzullo,
F. Raffaelli,
F. Spinella,
F. Colao,
M. Cordelli,
G. Corradi,
E. Diociaiuti,
R. Donghia,
S. Giovannella,
F. Happacher,
M. Martini,
S. Miscetti,
M. Ricci
, et al. (10 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab will search for the coherent $μ\to e$ conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain…
▽ More
The Mu2e experiment at Fermilab will search for the coherent $μ\to e$ conversion on aluminum atoms. The detector system consists of a straw tube tracker and a crystal calorimeter. A pre-production of 150 Silicon Photomultiplier arrays for the Mu2e calorimeter has been procured. A detailed quality assur- ance has been carried out on each SiPM for the determination of its own operation voltage, gain, dark current and PDE. The measurement of the mean-time-to-failure for a small random sample of the pro-production group has been also completed as well as the determination of the dark current increase as a function of the ioninizing and non-ioninizing dose.
△ Less
Submitted 20 November, 2017;
originally announced November 2017.
-
Neutron irradiation test of Hamamatsu, SensL and AdvanSiD UV-extended SiPMs
Authors:
M. Cordelli,
E. Diociaiuti,
R. Donghia,
A. Ferrari,
S. Miscetti,
S. Muller,
I. Sarra
Abstract:
In this paper, we report the measurement of the neutron radiation hardness of custom Silicon Photomultipliers arrays (SiPMs) manufactured by three companies: Hamamatsu (Japan), AdvanSiD (Italy) and SensL (Ireland). These custom SiPMs consist of a 2 x 3 array of 6 x 6 mm^2 monolithic cells with pixel sizes of respectively 50 um (Hamamatsu and SensL) and 30 um (AdvanSid).
A sample from each vendor…
▽ More
In this paper, we report the measurement of the neutron radiation hardness of custom Silicon Photomultipliers arrays (SiPMs) manufactured by three companies: Hamamatsu (Japan), AdvanSiD (Italy) and SensL (Ireland). These custom SiPMs consist of a 2 x 3 array of 6 x 6 mm^2 monolithic cells with pixel sizes of respectively 50 um (Hamamatsu and SensL) and 30 um (AdvanSid).
A sample from each vendor has been exposed to neutrons generated by the Elbe Positron Source facility (Dresden), up to a total fluence of ~ 8.5 x 10^11 n_(1 MeV)/cm^2. Test results show that the dark current increases almost linearly with the neutron fluence.
The room temperature annealing was quantified by measuring the dark current two months after the irradiation test. The dependence of the dark current on the device temperature and on the applied bias have been also evaluated.
△ Less
Submitted 15 March, 2018; v1 submitted 17 October, 2017;
originally announced October 2017.
-
The calorimeter of the Mu2e experiment at Fermilab
Authors:
N. Atanov,
V. Baranov,
J. Budagov,
F. Cervelli,
F. Colao,
M. Cordelli,
G. Corradi,
E. Dané,
Yu. I. Davydov,
S. Di Falco,
E. Diociaiuti,
S. Donati,
R. Donghia,
B. Echenard,
K. Flood,
S. Giovannella,
V. Glagolev,
F. Grancagnolo,
F. Happacher,
D. G. Hitlin,
M. Martini,
S. Miscetti,
T. Miyashita,
L. Morescalchi,
P. Murat
, et al. (12 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be explained in the framework of the current Standard Model of particle interactions and therefore would be a clear indication of new physics. In 3 years of data tak…
▽ More
The Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be explained in the framework of the current Standard Model of particle interactions and therefore would be a clear indication of new physics. In 3 years of data taking, Mu2e is expected to observe less than one background event mimicking the electron coming from muon conversion. Achieving such a level of background suppression requires a deep knowledge of the experimental apparatus: a straw tube tracker, measuring the electron momentum and time, a cosmic ray veto system rejecting most of cosmic ray background and a pure CsI crystal calorimeter, that will measure time of flight, energy and impact position of the converted electron. The calorimeter has to operate in a harsh radiation environment, in a 10-4 Torr vacuum and inside a 1 T magnetic field. The results of the first qualification tests of the calorimeter components are reported together with the energy and time performances expected from the simulation and measured in beam tests of a small scale prototype.
△ Less
Submitted 27 January, 2017;
originally announced January 2017.
-
Irradiation study of UV Silicon Photomultipliers for the Mu2e Calorimeter
Authors:
S. Baccaro,
A. Cemmi,
M. Cordelli,
E. Diociaiuti,
R. Donghia,
A. Ferrari,
S. Giovannella,
S. Miscetti,
S. Müller,
M. Pillon,
I. Sarra
Abstract:
The Mu2e calorimeter is composed of 1400 un-doped CsI crystals, coupled to large area UV extended Silicon Photomultipliers (SiPMs), arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and position resolutions. It should also be fast enough to handle the high rate background and it must operate and survive in the high radiation environment. Simulatio…
▽ More
The Mu2e calorimeter is composed of 1400 un-doped CsI crystals, coupled to large area UV extended Silicon Photomultipliers (SiPMs), arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and position resolutions. It should also be fast enough to handle the high rate background and it must operate and survive in the high radiation environment. Simulation studies estimated that, in the highest irradiated regions, each photo-sensor will absorb a dose of 20 krad and will be exposed to a neutron fluency of 5.5x10^11 n_(1MeV)/cm^2 in three years of running, with a safety factor of 3 included. At the end of 2015, we have concluded an irradiation campaign at the Frascati Neutron Generator (FNG, Frascati, Italy) measuring the response of two different 16 array models from Hamamatsu, which differ for the protection windows and a SiPM from FBK. In 2016, we have carried out two additional irradiation campaigns with neutrons and photons at the Helmholtz-Zentrum Dresden-Rossendorf (HZDR, Dresden, Germany) and at the Calliope gamma irradiation facility at ENEA-Casaccia, respectively. A negligible increment of the leakage current and no gain change have been observed with the dose irradiation. On the other hand, at the end of the neutron irradiation, the gain does not show large changes whilst the leakage current increases by around a factor of 2000. In these conditions, the too high leakage current makes problematic to bias the SiPMs, thus requiring to cool them down to a running temperature of ~0 °C.
△ Less
Submitted 23 January, 2017;
originally announced January 2017.
-
Radiation hardness test of un-doped CsI crystals and Silicon Photomultipliers for the Mu2e calorimeter
Authors:
Stefania Baccaro,
Alessia Cemmi,
Marco Cordelli,
Eleonora Diociaiuti,
Raffaella Donghia,
Simona Giovannella,
Stefano Loreti,
Stefano Miscetti,
Mario Pillon,
Ivano Sarra
Abstract:
The Mu2e calorimeter is composed by 1400 un-doped CsI crystals coupled to large area UV extended Silicon Photomultipliers arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and position. It should also be fast enough to handle the high rate background and it must operate and survive in a high radiation environment. Simulation studies estimated that…
▽ More
The Mu2e calorimeter is composed by 1400 un-doped CsI crystals coupled to large area UV extended Silicon Photomultipliers arranged in two annular disks. This calorimeter has to provide precise information on energy, timing and position. It should also be fast enough to handle the high rate background and it must operate and survive in a high radiation environment. Simulation studies estimated that, in the hottest regions, each crystal will absorb a dose of 300 Gy and will be exposed to a neutron fluency of 6 x 10^{11} n/cm^2 in 3 years of running.
Test of un-doped CsI crystals irradiated up to 900 Gy and to a neutron fluency up to 9 x 10^{11} n/cm^2 have been performed at CALLIOPE and FNG ENEA facilities in Italy. We present our study on the variation of light yield (LY) and longitudinal response uniformity (LRU) of these crystals after irradiation. The ionization dose does not modify LRU while a 20% reduction in LY is observed at 900 Gy. Similarly, the neutron flux causes an acceptable LY deterioration (<15%). A neutron irradiation test on different types of SIPMs (two different array models from Hamamatsu and one from FBK) have also been carried out by measuring the variation of the leakage current and the charge response to an ultraviolet led. We concluded that, in the experiment, we will need to cool down the SIPMs to 0 C reduce the leakage current to an acceptable level.
△ Less
Submitted 23 June, 2016;
originally announced June 2016.