Skip to main content

Showing 1–26 of 26 results for author: Di Stefano, P C F

Searching in archive physics. Search in all archives.
.
  1. Investigation of the cryogenic scintillation of pure and doped sodium-iodine

    Authors: M. Clark, F. Froborg, P. C. F. Di Stefano, F. Calaprice

    Abstract: We have studied the scintillation of pure and doped sodium iodide crystals handled in low humidity conditions under external $α$ and $γ$ excitation from room temperature down to 4K. The light yield of pure sodium iodide was seen to increase at low temperatures by a factor 30 compared to room temperature, up to a maximum of 40 photons/keV under $γ$ excitation at 60K, stabilizing to 30 photons/keV a… ▽ More

    Submitted 22 December, 2021; originally announced December 2021.

    Comments: 16 pages, 8 figures

  2. Ultraviolet-induced fluorescence of poly(methyl methacrylate) compared to 1,1,4,4-tetraphenyl-1,3-butadiene down to 4 K

    Authors: E. Ellingwood, H. Benmansour, Q. Hars, J. Hucker, V. Pereimak, J. M. Corning, P. Perrin, G. R. Araujo, P. C. F. Di Stefano, M. Kuźniak, T. R. Pollmann, M. Hamel, M. G. Boulay, B. Cai, D. Gallacher, A. Kemp, J. Mason, P. Skensved, M. Stringer

    Abstract: Several particle-physics experiments use poly(methyl methacrylate) (a.k.a. PMMA or acrylic) vessels to contain liquid scintillators. Superluminal charged particles emitted from radioactive impurities in or near the acrylic can emit Cherenkov radiation in the ultraviolet (UV) spectra range. If acrylic fluoresces in the visible range due to this UV light, it could be a source of background in experi… ▽ More

    Submitted 21 December, 2021; originally announced December 2021.

    Comments: 15 pages, 12 figures

  3. Fluorescence of pyrene-doped polystyrene films from room temperature down to 4 K for wavelength-shifting applications

    Authors: H. Benmansour, E. Ellingwood, Q. Hars, P. C. F. Di Stefano, D. Gallacher, M. Kuźniak, V. Pereimak, J. Anstey, M. G. Boulay, B. Cai, S. Garg, A. Kemp, J. Mason, P. Skensved, V. Strickland, M. Stringer

    Abstract: In liquid argon-based particle detectors, slow wavelength shifters (WLSs) could be used alongside the common, nanosecond scale, WLS tetraphenyl butadiene (TPB) for background mitigation purposes. At room temperature, pyrene has a moderate fluorescence light yield (LY) and a time constant of the order of hundreds of nanoseconds. In this work, four pyrene-doped polystyrene films with various puritie… ▽ More

    Submitted 15 October, 2021; originally announced October 2021.

    Comments: 22 pages, 14 figures

    Journal ref: JINST 16, P12029 (2021)

  4. Development and characterization of a slow wavelength shifting coating for background rejection in liquid argon detectors

    Authors: D. Gallacher, A. Leonhardt, H. Benmansour, E. Ellingwood, Q. Hars, M. Kuźniak, J. Anstey, B. Bondzior, M. G. Boulay, B. Cai, P. J. Dereń, P. C. F. Di Stefano, S. Garg, J. Mason, T. R. Pollmann, P. Skensved, V. Strickland, M. Stringer

    Abstract: We describe a technique, applicable to liquid-argon-based dark matter detectors, allowing for discrimination of alpha-decays in detector regions with incomplete light collection from nuclear-recoil-like events. Nuclear recoils and alpha events preferentially excite the liquid argon (LAr) singlet state, which has a decay time of ~6 ns. The wavelength-shifter TPB, which is typically applied to the… ▽ More

    Submitted 24 December, 2021; v1 submitted 14 September, 2021; originally announced September 2021.

    Comments: 18 pages,10 figures, Submitted to NIMA

  5. arXiv:2012.15232  [pdf, other

    physics.ins-det nucl-ex

    A novel experimental system for the KDK measurement of the $^{40}$K decay scheme relevant for rare event searches

    Authors: M. Stukel, B. C. Rasco, N. T. Brewer, P. C. F. Di Stefano, K. P. Rykaczewski, H. Davis, E. D. Lukosi, L. Hariasz, M. Constable, P. Davis, K. Dering, A. Fijałkowska, Z. Gai, K. C. Goetz, R. K. Grzywacz, J. Kostensalo, J. Ninkovic, P. Lechner, Y. Liu, M. Mancuso, C. L. Melcher, F. Petricca, C. Rouleau, P. Squillari, L. Stand , et al. (4 additional authors not shown)

    Abstract: Potassium-40 ($^{40}$K) is a long-lived, naturally occurring radioactive isotope. The decay products are prominent backgrounds for many rare event searches, including those involving NaI-based scintillators. $^{40}$K also plays a role in geochronological dating techniques. The branching ratio of the electron capture directly to the ground state of argon-40 has never been measured, which can cause… ▽ More

    Submitted 27 July, 2021; v1 submitted 30 December, 2020; originally announced December 2020.

    Comments: 20 pages, 24 figures, Submitted to NIM A

  6. Temperature-dependent fluorescence emission spectra of acrylic (PMMA) and tetraphenyl butadiene (TPB) excited with UV light

    Authors: J. M. Corning, G. R. Araujo, P. C. F. Di Stefano, V. Pereymak, T. Pollmann, P. Skensved

    Abstract: Acrylic (poly(methyl methacrylate) or PMMA) is commonly used as a vessel to hold scintillating liquids in rare-event searches. Certain types of PMMA can fluoresce with a low efficiency at room temperature. We have investigated the fluorescence spectra under 280nm ultraviolet (UV) excitation of the PMMA used in the DEAP dark matter search at various low temperatures. Fluorescence of this PMMA is ob… ▽ More

    Submitted 4 December, 2019; originally announced December 2019.

    Comments: LIDINE 2019, 5 pages, 3 figures

  7. arXiv:1804.10697  [pdf, other

    hep-ex astro-ph.CO physics.ins-det

    First Dark Matter Constraints from a SuperCDMS Single-Charge Sensitive Detector

    Authors: SuperCDMS Collaboration, R. Agnese, T. Aralis, T. Aramaki, I. J. Arnquist, E. Azadbakht, W. Baker, S. Banik, D. Barker, D. A. Bauer, T. Binder, M. A. Bowles, P. L. Brink, R. Bunker, B. Cabrera, R. Calkins, C. Cartaro, D. G. Cerdeno, Y. -Y. Chang, J. Cooley, B. Cornell, P. Cushman, P. C. F. Di Stefano, T. Doughty, E. Fascione , et al. (77 additional authors not shown)

    Abstract: We present the first limits on inelastic electron-scattering dark matter and dark photon absorption using a prototype SuperCDMS detector having a charge resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device). These electron-recoil limits significantly improve experimental constraints on dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We demonstrate a sensit… ▽ More

    Submitted 22 December, 2020; v1 submitted 27 April, 2018; originally announced April 2018.

    Comments: 6 pages + title and references, 6 figures, includes erratum submitted to PRL and data release

    Journal ref: Phys. Rev. Lett. 121, 051301 (2018)

  8. arXiv:1803.02903  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors

    Authors: R. Agnese, A. J. Anderson, T. Aramaki, W. Baker, D. Balakishiyeva, S. Banik, D. Barker, R. Basu Thakur, D. A. Bauer, T. Binder, A. Borgland, M. A. Bowles, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, R. Calkins, C. Cartaro, D. G. Cerdeno, H. Chagani, Y. -Y. Chang, Y. Chen, J. Cooley, B. Cornell, P. Cushman , et al. (84 additional authors not shown)

    Abstract: The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absol… ▽ More

    Submitted 27 July, 2018; v1 submitted 7 March, 2018; originally announced March 2018.

    Comments: 22 pages, 17 figures, 1 table, 1 appendix

  9. arXiv:1711.04004  [pdf, other

    nucl-ex physics.ins-det

    The KDK (potassium decay) experiment

    Authors: P. C. F. Di Stefano, N. Brewer, A. Fijałkowska, Z. Gai, K. C. Goetz, R. Grzywacz, D. Hamm, P. Lechner, Y. Liu, E. Lukosi, M. Mancuso, C. Melcher, J. Ninkovic, F. Petricca, B. C. Rasco, C. Rouleau, K. P. Rykaczewski, P. Squillari, L. Stand, D. Stracener, M. Stukel, M. Wolińska-Cichocka, I. Yavin

    Abstract: Potassium-40 (${}^{40}$K) is a background in many rare-event searches and may well play a role in interpreting results from the DAMA dark-matter search. The electron-capture decay of ${}^{40}$K to the ground state of ${}^{40}$Ar has never been measured and contributes an unknown amount of background. The KDK (potassium decay) collaboration will measure this branching ratio using a ${}^{40}$K sourc… ▽ More

    Submitted 10 November, 2017; originally announced November 2017.

    Comments: TAUP 2017 - XV International Conference on Topics in Astroparticle and Underground Physics

  10. arXiv:1707.01632  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    Low-Mass Dark Matter Search with CDMSlite

    Authors: SuperCDMS Collaboration, R. Agnese, A. J. Anderson, T. Aralis, T. Aramaki, I. J. Arnquist, W. Baker, D. Balakishiyeva, D. Barker, R. Basu Thakur, D. A. Bauer, T. Binder, M. A. Bowles, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, R. Calkins, C. Cartaro, D. G. Cerdeno, Y. Chang, H. Chagani, Y. Chen, J. Cooley, B. Cornell , et al. (83 additional authors not shown)

    Abstract: The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is… ▽ More

    Submitted 18 January, 2018; v1 submitted 6 July, 2017; originally announced July 2017.

    Comments: 30 Pages, 33 Figures v3 to match published version in PRD. v2 contains public release (and documentation) of the CDMSlite Run 2 data as ancillary files

    Journal ref: Phys. Rev. D 97, 022002 (2018)

  11. arXiv:1610.00006  [pdf, other

    physics.ins-det astro-ph.CO hep-ex

    Projected Sensitivity of the SuperCDMS SNOLAB experiment

    Authors: R. Agnese, A. J. Anderson, T. Aramaki, I. Arnquist, W. Baker, D. Barker, R. Basu Thakur, D. A. Bauer, A. Borgland, M. A. Bowles, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, R. Calkins, C. Cartaro, D. G. Cerdeño, H. Chagani, Y. Chen, J. Cooley, B. Cornell, P. Cushman, M. Daal, P. C. F. Di Stefano, T. Doughty , et al. (71 additional authors not shown)

    Abstract: SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle… ▽ More

    Submitted 30 September, 2016; originally announced October 2016.

    Comments: SuperCDMS SNOLAB Projected sensitivity reach

    Journal ref: Phys. Rev. D 95, 082002 (2017)

  12. A Multi-Channel Setup to Study Fractures in Scintillators

    Authors: A. Tantot, C. Bouard, R. Briche, G. Lefèvre, B. Manier, N. Zaïm, S. Deschanel, L. Vanel, P. C. F. Di Stefano

    Abstract: To investigate fractoluminescence in scintillating crystals used for particle detection, we have developed a multi-channel setup built around samples of double-cleavage drilled compression (DCDC) geometry in a controllable atmosphere. The setup allows the continuous digitization over hours of various parameters, including the applied load, and the compressive strain of the sample, as well as the a… ▽ More

    Submitted 4 August, 2016; originally announced August 2016.

  13. arXiv:1511.08424  [pdf, other

    astro-ph.IM physics.ins-det

    Temperature dependence of alpha-induced scintillation in the 1,1,4,4-tetraphenyl-1,3-butadiene wavelength shifter

    Authors: L. M. Veloce, M. Kuźniak, P. C. F. Di Stefano, A. J. Noble, M. G. Boulay, P. Nadeau, T. Pollmann, M. Clark, M. Piquemal, K. Schreiner

    Abstract: Liquid noble based particle detectors often use the organic wavelength shifter 1,1,4,4- tetraphenyl-1,3-butadiene (TPB) which shifts UV scintillation light to the visible regime, facilitating its detection, but which also can scintillate on its own. Dark matter searches based on this type of detector commonly rely on pulse-shape discrimination (PSD) for background mitigation. Alpha-induced scintil… ▽ More

    Submitted 7 June, 2016; v1 submitted 26 November, 2015; originally announced November 2015.

    Journal ref: 2016 JINST 11 P06003

  14. arXiv:1510.05787  [pdf, other

    physics.ins-det astro-ph.IM

    Low-Temperature Scintillation Properties of CaWO4 Crystals for Rare-Event Searches

    Authors: M. v. Sivers, M. Clark, P. C. F. Di Stefano, A. Erb, A. Gütlein, J. -C. Lanfranchi, A. Münster, P. Nadeau, M. Piquemal, W. Potzel, S. Roth, K. Schreiner, R. Strauss, S. Wawoczny, M. Willers, A. Zöller

    Abstract: In prospect of its application in cryogenic rare-event searches, we have investigated the low-temperature scintillation properties of CaWO4 crystals down to 3.4 K under α and γ excitation. Concerning the scintillation decay times, we observe a long component in the ms range which significantly contributes to the light yield below 40K. For the first time we have measured the temperature dependence… ▽ More

    Submitted 20 October, 2015; originally announced October 2015.

    Comments: The following article has been accepted by Journal of Applied Physics. After it is published, it will be found at http://scitation.aip.org/content/aip/journal/jap

  15. arXiv:1509.02448  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    WIMP-Search Results from the Second CDMSlite Run

    Authors: SuperCDMS Collaboration, R. Agnese, A. J. Anderson, T. Aramaki, M. Asai, W. Baker, D. Balakishiyeva, D. Barker, R. Basu Thakur, D. A. Bauer, J. Billard, A. Borgland, M. A. Bowles, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, R. Calkins, D. G. Cerdeno, H. Chagani, Y. Chen, J. Cooley, B. Cornell, P. Cushman, M. Daal , et al. (65 additional authors not shown)

    Abstract: The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization… ▽ More

    Submitted 9 March, 2016; v1 submitted 8 September, 2015; originally announced September 2015.

    Comments: 6 pages, 4 figures. v2 Matches the accepted version in PRL

    Report number: IPPP/15/56, DCTP/15/112

    Journal ref: Phys. Rev. Lett. 116, 071301 (2016)

  16. arXiv:1410.1573  [pdf, other

    physics.ins-det astro-ph.CO hep-ex

    Sensitivity of alkali halide scintillating calorimeters with particle identification to investigate the DAMA dark matter detection claim

    Authors: Patrick Nadeau, Michael Clark, P. C. F. Di Stefano, J. -C. Lanfranchi, S. Roth, M. von Sivers, Itay Yavin

    Abstract: Scintillating calorimeters are cryogenic detectors combining a measurement of scintillation with one of phonons to provide particle identification. In view of develo** alkali halide devices of this type able to check the DAMA/LIBRA claim for the observation of dark matter, we have simulated detector performances to determine their sensitivity by two methods with little model-dependence. We concl… ▽ More

    Submitted 7 April, 2015; v1 submitted 6 October, 2014; originally announced October 2014.

    Comments: 22 pages, 6 figures

    Journal ref: Astroparticle Physics 67, 62-69 (2015)

  17. arXiv:1410.1003  [pdf, other

    astro-ph.CO astro-ph.IM physics.ins-det

    Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data

    Authors: SuperCDMS Collaboration, R. Agnese, A. J. Anderson, D. Balakishiyeva, R. Basu Thakur, D. A. Bauer, J. Billard, A. Borgland, M. A. Bowles, D. Brandt, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, D. G. Cerdeno, H. Chagani, Y. Chen, J. Cooley, B. Cornell, C. H. Crewdson, P. Cushman, M. Daal, P. C. F. Di Stefano, T. Doughty, L. Esteban , et al. (62 additional authors not shown)

    Abstract: We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background… ▽ More

    Submitted 3 October, 2014; originally announced October 2014.

    Comments: 12 pages, 12 figures, submitted to PRD

    Journal ref: Phys. Rev. D 91, 052021 (2015)

  18. arXiv:1409.3270  [pdf, other

    hep-ex astro-ph.CO astro-ph.HE physics.ins-det

    First direct limits on Lightly Ionizing Particles with electric charge less than $e/6$

    Authors: R. Agnese, A. J. Anderson, D. Balakishiyeva, R. Basu Thakur, D. A. Bauer, J. Billard, A. Borgland, M. A. Bowles, D. Brandt, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, D. G. Cerdeno, H. Chagani, Y. Chen, J. Cooley, B. Cornell, C. H. Crewdson, P. Cushman, M. Daal, P. C. F. Di Stefano, T. Doughty, L. Esteban, S. Fallows , et al. (60 additional authors not shown)

    Abstract: While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six… ▽ More

    Submitted 3 February, 2015; v1 submitted 10 September, 2014; originally announced September 2014.

    Comments: 5 pages, 6 figures, submitted to PRL

    Journal ref: Phys. Rev. Lett. 114, 111302 (2015)

  19. arXiv:1402.7137  [pdf, other

    hep-ex astro-ph.CO physics.ins-det

    Search for Low-Mass WIMPs with SuperCDMS

    Authors: R. Agnese, A. J. Anderson, M. Asai, D. Balakishiyeva, R. Basu Thakur, D. A. Bauer, J. Beaty, J. Billard, A. Borgland, M. A. Bowles, D. Brandt, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, D. G. Cerdeno, H. Chagani, Y. Chen, M. Cherry, J. Cooley, B. Cornell, C. H. Crewdson, P. Cushman, M. Daal, D. DeVaney , et al. (70 additional authors not shown)

    Abstract: We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is i… ▽ More

    Submitted 12 March, 2014; v1 submitted 28 February, 2014; originally announced February 2014.

    Comments: 6 pages, 4 figures; figure 1 updated, submitted to Phys. Rev. Lett

    Journal ref: Phys. Rev. Lett. 112, 241302 (2014)

  20. arXiv:1309.3259  [pdf, ps, other

    physics.ins-det astro-ph.CO astro-ph.IM hep-ex

    CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted Calorimetric Ionization Detection in the SuperCDMS Experiment

    Authors: R. Agnese, A. J. Anderson, M. Asai, D. Balakishiyeva, R. Basu Thakur, D. A. Bauer, J. Billard, A. Borgland, M. A. Bowles, D. Brandt, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, D. G. Cerdeno, H. Chagani, J. Cooley, B. Cornell, C. H. Crewdson, P. Cushman, M. Daal, P. C. F. Di Stefano, T. Doughty, L. Esteban, S. Fallows , et al. (55 additional authors not shown)

    Abstract: SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were coll… ▽ More

    Submitted 20 December, 2013; v1 submitted 12 September, 2013; originally announced September 2013.

    Comments: 7 pages, 4 figures

    Journal ref: Phys. Rev. Lett. 112, 041302 (2014)

  21. arXiv:1305.3644  [pdf, ps, other

    cond-mat.mtrl-sci physics.ins-det

    Sound and light from fractures in scintillators

    Authors: A. Tantot, S. Santucci, O. Ramos, S. Deschanel, M. -A. Verdier, E. Mony, Y. Wei, S. Ciliberto, L. Vanel, P. C. F. Di Stefano

    Abstract: Prompted by intriguing events observed in certain particle-physics searches for rare events, we study light and acoustic emission simultaneously in some inorganic scintillators subject to mechanical stress. We observe mechanoluminescence in ${Bi}_4{Ge}_{3}{O}_{12}$, ${CdWO}_{4}$ and ${ZnWO}_{4}$, in various mechanical configurations at room temperature and ambient pressure. We analyze how the ligh… ▽ More

    Submitted 17 October, 2013; v1 submitted 15 May, 2013; originally announced May 2013.

    Journal ref: Phys. Rev. Lett. 111, 154301 (2013)

  22. arXiv:1305.2405  [pdf, other

    physics.ins-det astro-ph.GA hep-ex

    Demonstration of Surface Electron Rejection with Interleaved Germanium Detectors for Dark Matter Searches

    Authors: R. Agnese, A. J. Anderson, D. Balakishiyeva, R. Basu Thakur, D. A. Bauer, A. Borgland, D. Brandt, P. L. Brink, R. Bunker, B. Cabrera, D. O. Caldwell, D. G. Cerdeno, H. Chagani, M. Cherry, J. Cooley, B. Cornell, C. H. Crewdson, P. Cushman, M. Daal, P. C. F. Di Stefano, E. Do Couto E Silva, T. Doughty, L. Esteban, S. Fallows, E. Figueroa-Feliciano , et al. (66 additional authors not shown)

    Abstract: The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were teste… ▽ More

    Submitted 4 October, 2013; v1 submitted 10 May, 2013; originally announced May 2013.

    Comments: 5 pages, 4 figures, submitted to journal

  23. Counting photons at low temperature with a streaming time-to-digital converter

    Authors: P. C. F. Di Stefano, P. Nadeau, C. J. G. Onderwater, C. Trudeau, M. -A. Verdier

    Abstract: We present some aspects of photon counting to study scintillators at low temperatures. A time-to-digital converter (TDC) had been configured to acquire several-minute-long streams of data, simplifying the multiple photon counting coincidence technique. Results in terms of light yield and time structure of a ZnWO4 scintillator are comparable to those obtained with a fast digitizer. Streaming data a… ▽ More

    Submitted 10 July, 2012; originally announced July 2012.

    Comments: Fig 6 low res

    Journal ref: Nucl. Instr. Meth. Phys. Res. A, vol 700, pp 40-52, Feb 2013

  24. arXiv:physics/0612081  [pdf, ps, other

    physics.geo-ph cond-mat.mtrl-sci physics.gen-ph

    Comment on "Universal Distribution of Interearthquake Times"

    Authors: J. Astrom, P. C. F. Di Stefano, F. Probst, L. Stodolsky, J. Timonen

    Abstract: We note the striking similarity between earthquake and CRESST microfracture data for waiting times.

    Submitted 8 December, 2006; originally announced December 2006.

    Comments: One page one figure

  25. arXiv:physics/0504151  [pdf, ps, other

    physics.ins-det astro-ph hep-ex

    Fracture Processes Observed with A Cryogenic Detector

    Authors: J. Astrom, P. C. F. Di Stefano, F. Proebst, L. Stodolsky, J. Timonen, C. Bucci, S. Cooper, C. Cozzini, F. v. Feilitzsch, H. Kraus, J. Marchese, O. Meier, U. Nagel, Y. Ramachers, W. Seidel, M. Sisti, S. Uchaikin, L. Zerle

    Abstract: In the early stages of running of the CRESST dark matter search using sapphire detectors at very low temperature, an unexpectedly high rate of signal pulses appeared. Their origin was finally traced to fracture events in the sapphire due to the very tight clam** of the detectors. During extensive runs the energy and time of each event was recorded, providing large data sets for such phenomena.… ▽ More

    Submitted 21 March, 2006; v1 submitted 21 April, 2005; originally announced April 2005.

    Comments: Fig 4 and surrounding discussion changed. References added, langauge clarified, with greater stress on sensitivity and total energy detection. Error in metadata fixed

    Journal ref: Phys.Lett. A356 (2006) 262-266

  26. arXiv:physics/0307042  [pdf, ps, other

    physics.ins-det

    A Textured Silicon Calorimetric Light Detector

    Authors: P. C. F. Di Stefano, T. Frank, G. Angloher, M. Bruckmayer, C. Cozzini, D. Hauff, F. Proebst, S. Rutzinger, W. Seidel, L. Stodolsky, J. Schmidt

    Abstract: We apply the standard photovoltaic technique of texturing to reduce the reflectivity of silicon cryogenic calorimetric light detectors. In the case of photons with random incidence angles, absorption is compatible with the increase in surface area. For the geometrically thin detectors studied, energy resolution from athermal phonons, dominated by position dependence, is proportional to the surfa… ▽ More

    Submitted 7 July, 2003; originally announced July 2003.

    Comments: Submitted to Journal of Applied Physics

    Journal ref: Journal of Applied Physics, Vol. 94, No. 10, 6887, 15 November 2003