Response of G-NUMEN LaBr$_3$(Ce) detectors to high counting rates
Authors:
Elisa Maria Gandolfo,
José Roberto Brandao Oliveira,
Luigi Campajola,
Dimitra Pierroutsakou,
Alfonso Boiano,
Clementina Agodi,
Francesco Cappuzzello,
Diana Carbone,
Manuela Cavallaro,
Irene Ciraldo,
Daniela Calvo,
Franck Delaunay,
Canel Eke,
Fabio Longhitano,
Nilberto Medina,
Mauricio Moralles,
Diego Sartirana,
Vijay R. Sharma,
Alessandro Spatafora,
Dennis Toufen,
Paolo Finocchiaro
Abstract:
The G-NUMEN array is the future gamma spectrometer of the NUMEN experiment (Nuclear Matrix Element for the Neutrinoless double beta decay), to be installed around the object point of the MAGNEX magnetic spectrometer at the INFN-LNS laboratory. This project aims at exploring Double Charge Exchange (DCE) reactions in order to obtain crucial information about the neutrinoless double beta decay (…
▽ More
The G-NUMEN array is the future gamma spectrometer of the NUMEN experiment (Nuclear Matrix Element for the Neutrinoless double beta decay), to be installed around the object point of the MAGNEX magnetic spectrometer at the INFN-LNS laboratory. This project aims at exploring Double Charge Exchange (DCE) reactions in order to obtain crucial information about the neutrinoless double beta decay ($0νββ$). The primary objective of the G-NUMEN array is to detect the gamma rays emitted from the deexcitation of the excited states populated via DCE reactions with good energy resolution and detection efficiency, amidst a background composed of transitions from competing reaction channels with far higher cross sections. To achieve this, the G-NUMEN signals will be processed in coincidence with those generated by the detection of the reaction ejectiles in the MAGNEX Focal Plane Detector(FPD). Under the expected experimental conditions, G-NUMEN detectors will operate at high counting rates, of the order of hundreds of kHz per detector, while maintaining excellent energy and timing resolutions. The complete array will consist of over 100 LaBr$_3$(Ce) scintillators. Initial tests have been conducted on the first detectors of the array, allowing for the determination of their performance at high rates.
△ Less
Submitted 15 July, 2023;
originally announced July 2023.
-
Characterization of a gas detector prototype based on Thick-GEM for the MAGNEX focal plane detector
Authors:
I. Ciraldo,
G. A. Brischetto,
D. Torresi,
M. Cavallaro,
C. Agodi,
A. Boiano,
S. Calabrese,
F. Cappuzzello,
D. Carbone,
M. Cortesi,
F. Delaunay,
M. Fisichella,
L. Neri,
A. Pandalone,
P. Paolucci,
B. Rossi,
O. Sgouros,
V. Soukeras,
A. Spatafora,
A. Vanzanella,
A. Yildirim
Abstract:
A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN project. It has been designed to operate at low gas pressure for detecting medium to heavy ions in the energy range between 15 and 60 AMeV. It is a drift chamber based on Multi-layer Thick-GEM (M-THGEM) as electron multipli…
▽ More
A new gas detector prototype for the upgrade of the focal plane detector of the MAGNEX large-acceptance magnetic spectrometer has been developed and tested in view of the NUMEN project. It has been designed to operate at low gas pressure for detecting medium to heavy ions in the energy range between 15 and 60 AMeV. It is a drift chamber based on Multi-layer Thick-GEM (M-THGEM) as electron multiplication technology. Tests with two different M-THGEM layouts have been performed using both a radioactive $α$-particle source and accelerated heavy-ion beams. The characterization of the detector in terms of measured currents that flow through the electrodes as a function of different parameters, including applied voltages, gas pressure and rate of incident particle, is described. The gain and ion backflow properties have been studied.
△ Less
Submitted 5 April, 2023;
originally announced April 2023.
-
Neutron-$γ$ discrimination with organic scintillators: Intrinsic pulse shape and light yield contributions
Authors:
M. Sénoville,
F. Delaunay,
M. Pârlog,
N. L. Achouri,
N. A. Orr
Abstract:
A comparative study of the neutron-$γ$ Pulse Shape Discrimination (PSD) with seven organic scintillators is performed using an identical setup and digital electronics. The scintillators include plastics (EJ-299-33 and a plastic prototype), single crystals (stilbene and the recent doped $p$-terphenyl) and liquids (BC501A, NE213 and the deuterated liquid BC537). First, the overall PSD performance of…
▽ More
A comparative study of the neutron-$γ$ Pulse Shape Discrimination (PSD) with seven organic scintillators is performed using an identical setup and digital electronics. The scintillators include plastics (EJ-299-33 and a plastic prototype), single crystals (stilbene and the recent doped $p$-terphenyl) and liquids (BC501A, NE213 and the deuterated liquid BC537). First, the overall PSD performance of the different scintillators is compared and threshold neutron energies for a given discrimination quality are determined. Then, using statistical arguments, two intrinsic contributions to the PSD capability of the scintillating materials are disentangled: the light yield and the specific pulse shapes induced by neutrons and $γ$-rays. This separation provides additional insight into the behaviour of organic scintillators and allows a detailed comparison of the discrimination performance of the various materials. On the basis of this analysis, limitations of current organic scintillators and of recently proposed alternative scintillators are discussed.
△ Less
Submitted 12 May, 2020;
originally announced May 2020.
-
The NUMEN project: NUclear Matrix Elements for Neutrinoless double beta decay
Authors:
F. Cappuzzello,
C. Agodi,
M. Cavallaro,
D. Carbone,
S. Tudisco,
D. Lo Presti,
J. R. B. Oliveira,
P. Finocchiaro,
M. Colonna,
D. Rifuggiato,
L. Calabretta,
D. Calvo,
L. Pandola,
L. Acosta,
N. Auerbach,
J. Bellone,
R. Bijker,
D. Bonanno,
D. Bongiovanni,
T. Borello-Lewin,
I. Boztosun,
O. Brunasso,
S. Burrello,
S. Calabrese,
A. Calanna
, et al. (46 additional authors not shown)
Abstract:
The article describes the main achievements of the NUMEN project together with an updated and detailed overview of the related R&D activities and theoretical developments. NUMEN proposes an innovative technique to access the nuclear matrix elements entering the expression of the lifetime of the double beta decay by cross section measurements of heavy-ion induced Double Charge Exchange (DCE) reacti…
▽ More
The article describes the main achievements of the NUMEN project together with an updated and detailed overview of the related R&D activities and theoretical developments. NUMEN proposes an innovative technique to access the nuclear matrix elements entering the expression of the lifetime of the double beta decay by cross section measurements of heavy-ion induced Double Charge Exchange (DCE) reactions. Despite the two processes, namely neutrinoless double beta decay and DCE reactions, are triggered by the weak and strong interaction respectively, important analogies are suggested. The basic point is the coincidence of the initial and final state many-body wave-functions in the two types of processes and the formal similarity of the transition operators. First experimental results obtained at the INFN-LNS laboratory for the 40Ca(18O,18Ne)40Ar reaction at 270 MeV, give encouraging indication on the capability of the proposed technique to access relevant quantitative information. The two major aspects for this project are the K800 Superconducting Cyclotron and MAGNEX spectrometer. The former is used for the acceleration of the required high resolution and low emittance heavy ion beams and the latter is the large acceptance magnetic spectrometer for the detection of the ejectiles. The use of the high-order trajectory reconstruction technique, implemented in MAGNEX, allows to reach the experimental resolution and sensitivity required for the accurate measurement of the DCE cross sections at forward angles. However, the tiny values of such cross sections and the resolution requirements demand beam intensities much larger than manageable with the present facility. The on-going upgrade of the INFN-LNS facilities in this perspective is part of the NUMEN project and will be discussed in the article.
△ Less
Submitted 21 November, 2018;
originally announced November 2018.
-
High Precision Measurement of the $^{19}$Ne Half-life using real-time digital acquisition
Authors:
C. Fontbonne,
P. Ujić,
F. de Oliveira Santos,
X. Fléchard,
F. Rotaru,
N. L. Achouri,
V. Girard Alcindor,
B. Bastin,
F. Boulay,
J. B. Briand,
A. M. Sánchez-Benítez,
H. Bouzomita,
C. Borcea,
R. Borcea,
B. Blank,
B. Carniol,
I. Čeliković,
P. Delahaye,
F. Delaunay,
D. Etasse,
G. Fremont,
G. de France,
J. M. Fontbonne,
G. F. Grinyer,
J. Harang
, et al. (12 additional authors not shown)
Abstract:
The half-life of $^{19}$Ne has been measured using a real-time digital multiparametric acquisition system providing an accurate time-stamp and relevant information on the detectors signals for each decay event. An exhaustive offline analysis of the data gave unique access to experimental effects potentially biasing the measurement. After establishing the influence factors impacting the measurement…
▽ More
The half-life of $^{19}$Ne has been measured using a real-time digital multiparametric acquisition system providing an accurate time-stamp and relevant information on the detectors signals for each decay event. An exhaustive offline analysis of the data gave unique access to experimental effects potentially biasing the measurement. After establishing the influence factors impacting the measurement such as after-pulses, pile-up, gain and base line fluctuations, their effects were accurately estimated and the event selection optimized. The resulting half-life, $17.2569\pm0.0019_{(stat)}\pm0.0009_{(syst)}$~s, is the most precise up to now for $^{19}$Ne. It is found in agreement with two recent precise measurements and not consistent with the most recent one [L.J. Broussard {\it et al.}, Phys. Rev. Lett. {\bf112}, 212301 (2014)] by 3.0 standard deviations. The full potential of the technique for nuclei with half-lives of a few seconds is discussed.
△ Less
Submitted 27 September, 2017;
originally announced September 2017.
-
Tracking rare-isotope beams with microchannel plates
Authors:
A. M. Rogers,
A. Sanetullaev,
W. G. Lynch,
M. B. Tsang,
J. Lee,
D. Bazin,
D. Coupland,
V. Henzl,
D. Henzlova,
M. Kilburn,
M. S. Wallace,
M. Youngs,
F. Delaunay,
M. Famiano,
D. Shapira,
K. L. Jones,
K. T. Schmitt,
Z. Y. Sun
Abstract:
A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current design is an adaptation of an assembly used for low-energy beams ($\sim$1.4 MeV/nucleon). In order to improve resolution in tracking high-energy heavy-ion beams,…
▽ More
A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current design is an adaptation of an assembly used for low-energy beams ($\sim$1.4 MeV/nucleon). In order to improve resolution in tracking high-energy heavy-ion beams, the magnetic field strength between the secondary-electron accelerating foil and the microchannel plate had to be increased substantially. Results from an experiment using a 37-MeV/nucleon ${}^{56}$Ni beam show that the tracking system can achieve sub-nanosecond timing resolution and a position resolution of $\sim$1 mm for beam intensities up to $5\times10^{5}$ pps.
△ Less
Submitted 11 September, 2013;
originally announced September 2013.