Using graph neural networks to reconstruct charged pion showers in the CMS High Granularity Calorimeter
Authors:
M. Aamir,
B. Acar,
G. Adamov,
T. Adams,
C. Adloff,
S. Afanasiev,
C. Agrawal,
C. Agrawal,
A. Ahmad,
H. A. Ahmed,
S. Akbar,
N. Akchurin,
B. Akgul,
B. Akgun,
R. O. Akpinar,
E. Aktas,
A. AlKadhim,
V. Alexakhin,
J. Alimena,
J. Alison,
A. Alpana,
W. Alshehri,
P. Alvarez Dominguez,
M. Alyari,
C. Amendola
, et al. (550 additional authors not shown)
Abstract:
A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadr…
▽ More
A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadronic section. The shower reconstruction method is based on graph neural networks and it makes use of a dynamic reduction network architecture. It is shown that the algorithm is able to capture and mitigate the main effects that normally hinder the reconstruction of hadronic showers using classical reconstruction methods, by compensating for fluctuations in the multiplicity, energy, and spatial distributions of the shower's constituents. The performance of the algorithm is evaluated using test beam data collected in 2018 prototype of the CMS HGCAL accompanied by a section of the CALICE AHCAL prototype. The capability of the method to mitigate the impact of energy leakage from the calorimeter is also demonstrated.
△ Less
Submitted 30 June, 2024; v1 submitted 17 June, 2024;
originally announced June 2024.
-
Performances of an upgraded front-end-board for the NectarCAM camera
Authors:
Federica Bradascio,
F. Brun,
F. Cangemi,
S. Caroff,
E. Delagnes,
D. Gascon,
J. -F. Glicenstein,
C. Juramy-Gilles,
J. -P. Lenain,
J. -L. Meunier,
A. Sanuy,
P. Sizun,
F. Toussenel,
B. Vallage,
V. Voisin
Abstract:
The Front-End Board (FEB) is a key component of the NectarCAM camera, which has been developed for the Medium-Sized-Telescopes (MST) of the Cherenkov Telescope Array Observatory (CTAO). The FEB is responsible for reading and converting the signals from the camera's photo-multiplier tubes (PMTs) into digital data, as well as generating module level trigger signals. This contribution provides an ove…
▽ More
The Front-End Board (FEB) is a key component of the NectarCAM camera, which has been developed for the Medium-Sized-Telescopes (MST) of the Cherenkov Telescope Array Observatory (CTAO). The FEB is responsible for reading and converting the signals from the camera's photo-multiplier tubes (PMTs) into digital data, as well as generating module level trigger signals. This contribution provides an overview of the design and performances of a new version of the FEB that utilizes an improved version of the NECTAr chip. The NECTAr chip includes a switched capacitor array for sampling signals at 1 GHz, and a 12-bit analog-to-digital converter (ADC) for digitizing each sample when the trigger signal is received. The integration of this advanced NECTAr chip significantly reduces the deadtime of NectarCAM by an order of magnitude as compared to the previous version. This contribution also presents the results of laboratory testing of the new FEB, including measurements of timing performance, linearity, dynamic range, and deadtime.
△ Less
Submitted 3 October, 2023;
originally announced October 2023.
-
Performance of the CMS High Granularity Calorimeter prototype to charged pion beams of 20$-$300 GeV/c
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
J. P. Figueiredo de sa Sousa de Almeida,
P. G. Dias de Almeida,
A. Alpana,
M. Alyari,
I. Andreev,
U. Aras,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Banerjee,
P. DeBarbaro,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (435 additional authors not shown)
Abstract:
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing med…
▽ More
The upgrade of the CMS experiment for the high luminosity operation of the LHC comprises the replacement of the current endcap calorimeter by a high granularity sampling calorimeter (HGCAL). The electromagnetic section of the HGCAL is based on silicon sensors interspersed between lead and copper (or copper tungsten) absorbers. The hadronic section uses layers of stainless steel as an absorbing medium and silicon sensors as an active medium in the regions of high radiation exposure, and scintillator tiles directly readout by silicon photomultipliers in the remaining regions. As part of the development of the detector and its readout electronic components, a section of a silicon-based HGCAL prototype detector along with a section of the CALICE AHCAL prototype was exposed to muons, electrons and charged pions in beam test experiments at the H2 beamline at the CERN SPS in October 2018. The AHCAL uses the same technology as foreseen for the HGCAL but with much finer longitudinal segmentation. The performance of the calorimeters in terms of energy response and resolution, longitudinal and transverse shower profiles is studied using negatively charged pions, and is compared to GEANT4 predictions. This is the first report summarizing results of hadronic showers measured by the HGCAL prototype using beam test data.
△ Less
Submitted 27 May, 2023; v1 submitted 9 November, 2022;
originally announced November 2022.
-
Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20-300 GeV positrons
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
F. Alam Khan,
M. Alhusseini,
J. Alison,
A. Alpana,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
P. Aspell,
I. O. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
S. Bannerjee,
P. Bargassa,
D. Barney,
F. Beaudette
, et al. (364 additional authors not shown)
Abstract:
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glu…
▽ More
The Compact Muon Solenoid Collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1 cm$^2$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.
△ Less
Submitted 31 March, 2022; v1 submitted 12 November, 2021;
originally announced November 2021.
-
High resolution MCP-PMT Readout Using Transmission Lines
Authors:
M. Follin,
R. Chyzh,
C. -H. Sung,
D. Breton,
J. Maalmi,
T. Chaminade,
E. Delagnes,
K. Schäfers,
C. Weinheimer,
D. Yvon,
V. Sharyy
Abstract:
We study the potential of the MCP-PMT read-out to detect single photo-electron using transmission lines. Such a solution limits the number of read-out channels, has a uniform time resolution across the PMT surface and provides quasi-continuous measurement of the spatial coordinates. The proposed solution is designed to be used in the BOLD-PET project aiming to develop an innovative detection modul…
▽ More
We study the potential of the MCP-PMT read-out to detect single photo-electron using transmission lines. Such a solution limits the number of read-out channels, has a uniform time resolution across the PMT surface and provides quasi-continuous measurement of the spatial coordinates. The proposed solution is designed to be used in the BOLD-PET project aiming to develop an innovative detection module for the positron emission tomography using the liquid detection media, the tri-methyl bismuth. In this study we use the commercial MCP-PMT Planacon from Photonis, with 32x32 anode structure. The PCB gathers signals from anode pads in 32 transmission lines which are read-out from both ends. Amplifier boards and SAMPIC modules, developed in our labs, allow us to realize the cost-effective, multi-channel digitization of signals with excellent precision. For a single photo-electron, we measured a time resolution of 70~ps (FWHM) simultaneously with a spatial accuracy of 1.6~mm and 0.9~mm (FWHM) along and across transmission lines correspondingly.
△ Less
Submitted 25 November, 2021; v1 submitted 7 August, 2021;
originally announced August 2021.
-
IDeF-X HD: a CMOS ASIC for the readout of Cd(Zn)Te Detectors for space-borne applications
Authors:
Olivier Gevin,
Francis Lugiez,
Alicja Michalowska,
Aline Meuris,
Olivier Limousin,
Eric Delagnes,
Olivier Lemaire,
Frédéric Pinsard
Abstract:
IDeF-X HD is a 32-channel analog front-end with self-triggering capability optimized for the readout of 16 x 16 pixels CdTe or CdZnTe pixelated detectors to build low power micro gamma camera. IDeF-X HD has been designed in the standard AMS CMOS 0.35 microns process technology. Its power consumption is 800 micro watt per channel. The dynamic range of the ASIC can be extended to 1.1 MeV thanks to t…
▽ More
IDeF-X HD is a 32-channel analog front-end with self-triggering capability optimized for the readout of 16 x 16 pixels CdTe or CdZnTe pixelated detectors to build low power micro gamma camera. IDeF-X HD has been designed in the standard AMS CMOS 0.35 microns process technology. Its power consumption is 800 micro watt per channel. The dynamic range of the ASIC can be extended to 1.1 MeV thanks to the in-channel adjustable gain stage. When no detector is connected to the chip and without input current, a 33 electrons rms ENC level is achieved after sha** with 10.7 micro seconds peak time. Spectroscopy measurements have been performed with CdTe Schottky detectors. We measured an energy resolution of 4.2 keV FWHM at 667 keV (137-Cs) on a mono-pixel configuration. Meanwhile, we also measured 562 eV and 666 eV FWHM at 14 keV and 60 keV respectively (241-Am) with a 256 small pixel array and a low detection threshold of 1.2 keV. Since IDeF-X HD is intended for space-borne applications in astrophysics, we evaluated its radiation tolerance and its sensitivity to single event effects. We demonstrated that the ASIC remained fully functional without significant degradation of its performances after 200 krad and that no single event latch-up was detected putting the Linear Energy Transfer threshold above 110 MeV/(mg/cm2). Good noise performance and radiation tolerance make the chip well suited for X-rays energy discrimination and high-energy resolution. The chip is space qualified and flies on board the Solar Orbiter ESA mission launched in 2020.
△ Less
Submitted 3 February, 2021;
originally announced February 2021.
-
Construction and commissioning of CMS CE prototype silicon modules
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
M. Andrews,
P. Aspell,
I. A. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
P. Bargassa,
D. Barney,
E. Becheva,
P. Behera,
A. Belloni
, et al. (307 additional authors not shown)
Abstract:
As part of its HL-LHC upgrade program, the CMS Collaboration is develo** a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modul…
▽ More
As part of its HL-LHC upgrade program, the CMS Collaboration is develo** a High Granularity Calorimeter (CE) to replace the existing endcap calorimeters. The CE is a sampling calorimeter with unprecedented transverse and longitudinal readout for both electromagnetic (CE-E) and hadronic (CE-H) compartments. The calorimeter will be built with $\sim$30,000 hexagonal silicon modules. Prototype modules have been constructed with 6-inch hexagonal silicon sensors with cell areas of 1.1~$cm^2$, and the SKIROC2-CMS readout ASIC. Beam tests of different sampling configurations were conducted with the prototype modules at DESY and CERN in 2017 and 2018. This paper describes the construction and commissioning of the CE calorimeter prototype, the silicon modules used in the construction, their basic performance, and the methods used for their calibration.
△ Less
Submitted 10 December, 2020;
originally announced December 2020.
-
The DAQ system of the 12,000 Channel CMS High Granularity Calorimeter Prototype
Authors:
B. Acar,
G. Adamov,
C. Adloff,
S. Afanasiev,
N. Akchurin,
B. Akgün,
M. Alhusseini,
J. Alison,
G. Altopp,
M. Alyari,
S. An,
S. Anagul,
I. Andreev,
M. Andrews,
P. Aspell,
I. A. Atakisi,
O. Bach,
A. Baden,
G. Bakas,
A. Bakshi,
P. Bargassa,
D. Barney,
E. Becheva,
P. Behera,
A. Belloni
, et al. (307 additional authors not shown)
Abstract:
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endca…
▽ More
The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ${\approx}12,000\rm{~channels}$ of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry PI computers.
△ Less
Submitted 8 December, 2020; v1 submitted 7 December, 2020;
originally announced December 2020.
-
Design study of a scintronic crystal targeting tens of picoseconds time resolution for gamma ray imaging: the ClearMind detector
Authors:
D. Yvon,
V. Sharyy,
M. Follin,
J-P Bard,
D. Breton,
J. Maalmi,
C. Morel,
E. Delagnes
Abstract:
We describe the concept of a new gamma ray scintronic detector targeting a time resolution of the order of 25 ps FWHM, with millimetric volume reconstruction and high detection efficiency. Its design consists of a monolithic large PbWO4 scintillating crystal with an efficient photocathode directly deposited on it. With an index of refraction higher for the photocathode than for the crystal, this d…
▽ More
We describe the concept of a new gamma ray scintronic detector targeting a time resolution of the order of 25 ps FWHM, with millimetric volume reconstruction and high detection efficiency. Its design consists of a monolithic large PbWO4 scintillating crystal with an efficient photocathode directly deposited on it. With an index of refraction higher for the photocathode than for the crystal, this design negates the total reflection effect of optical photons at the crystal/photo-detector optical interface, and thus largely improves optical coupling between the crystal and the photodetector. This allows to detect efficiently the Cherenkov light produced by 511 keV photoelectric conversions in PbWO4, and to optimize the detector time resolution. Furthermore, the low-yield, fast scintillation light produced additionally by PbWO4 increases the detected photon statistics by a factor 10, thus fostering accurate (3 dimensional) localization of the gamma ray interaction within the crystal and providing a fair measurement of the deposited energy. This paper lists the technological challenges that have to be overcome in order to build this scintronic detector. We show that all the key technologies have now been demonstrated and present results of a preliminary Monte Carlo simulation, which include an innovative event reconstruction algorithm to support the claimed performances of the detector.
△ Less
Submitted 26 June, 2020;
originally announced June 2020.
-
Fast and Efficient Detection of 511 keV Photons using Cherenkov Light in PbF$_2$ Crystal coupled to a MCP-PMT and SAMPIC Digitization Module
Authors:
C. Canot,
M. Alokhina,
P. Abbon,
J. P. Bard,
D. Breton,
E. Delagnes,
J. Maalmi,
G. Tauzin,
D. Yvon,
V. Sharyy
Abstract:
We study the possibility to use the Cherenkov light for the efficient detection of 511 keV photons with the goal to use it in TOF-PET. We designed and tested two detection modules consisting of PbF$_2$ crystals attached to Planacon MCP-PMT XP85012. Amplified PMT signals are digitized by the SAMPIC module with high readout rate, up to $10^5$ events/s, and a negligible contribution to the time resol…
▽ More
We study the possibility to use the Cherenkov light for the efficient detection of 511 keV photons with the goal to use it in TOF-PET. We designed and tested two detection modules consisting of PbF$_2$ crystals attached to Planacon MCP-PMT XP85012. Amplified PMT signals are digitized by the SAMPIC module with high readout rate, up to $10^5$ events/s, and a negligible contribution to the time resolution, below 20 ps (FWHM). We developed a fast 2D scanning system to calibrate the PMT time response and studied in details the timing characteristics of the Planacon PMT. Using a radioactive $^{22}$Na source we measured a detection efficiency of 24% for 511 keV photons in a 10 mm thick crystal and a coincidence resolving time of 280 ps. We analyzed the main factors limiting the time resolution of the large-surface detection module and proposed solutions to improve it, which will be tested in our future project.
△ Less
Submitted 14 November, 2019; v1 submitted 13 September, 2019;
originally announced September 2019.
-
What is the theoretical time precision achievable using a dCFD algorithm ?
Authors:
Eric Delagnes
Abstract:
The time precision achievable using standard analog methods is well known. Several expressions for timing methods using digitized signals have been recently proposed in workshops, conferences or training courses. Most of them are only partially exact. This paper presents a comprehensive calculation of the timing precision for algorithms using digital treatment of digitized signal to mimic analog d…
▽ More
The time precision achievable using standard analog methods is well known. Several expressions for timing methods using digitized signals have been recently proposed in workshops, conferences or training courses. Most of them are only partially exact. This paper presents a comprehensive calculation of the timing precision for algorithms using digital treatment of digitized signal to mimic analog discriminator-based methods. The results of these calculations are discussed for various cases of correlation between samples.
△ Less
Submitted 16 June, 2016;
originally announced June 2016.
-
Measurements of timing resolution of ultra-fast silicon detectors with the SAMPIC waveform digitizer
Authors:
Dominique Breton,
Victor De Cacqueray,
Éric Delagnes,
Hervé Grabas,
Jihane Maalmi,
Nicola Minafra,
Christophe Royon,
Matthias Saimpert
Abstract:
The SAMpler for PICosecond time (SAMPIC) chip has been designed by a collaboration including CEA/IRFU/SEDI, Saclay and CNRS/LAL/SERDI, Orsay. It benefits from both the quick response of a time to digital converter and the versatility of a waveform digitizer to perform accurate timing measurements. Thanks to the sampled signals, smart algorithms making best use of the pulse shape can be used to imp…
▽ More
The SAMpler for PICosecond time (SAMPIC) chip has been designed by a collaboration including CEA/IRFU/SEDI, Saclay and CNRS/LAL/SERDI, Orsay. It benefits from both the quick response of a time to digital converter and the versatility of a waveform digitizer to perform accurate timing measurements. Thanks to the sampled signals, smart algorithms making best use of the pulse shape can be used to improve time resolution. A software framework has been developed to analyse the SAMPIC output data and extract timing information by using either a constant fraction discriminator or a fast cross-correlation algorithm. SAMPIC timing capabilities together with the software framework have been tested using pulses generated by a signal generator or by a silicon detector illuminated by a pulsed infrared laser. Under these ideal experimental conditions, the SAMPIC chip has proven to be capable of timing resolutions down to 4 ps with synthesized signals and 40 ps with silicon detector signals.
△ Less
Submitted 11 August, 2016; v1 submitted 8 April, 2016;
originally announced April 2016.
-
Analogue Sum ASIC for L1 Trigger Decision in Cherenkov Telescope Cameras
Authors:
Joan Abel Barrio,
Oscar Blanch,
Joan Boix,
Eric Delagnes,
Carlos Delgado,
Lluis Freixas Coromina,
David Gascon,
Fabrice Guilloux,
Ruben Lopez Coto,
Gustavo Martinez,
Andreu Sanuy,
Luis Angel Tejedor
Abstract:
The Cherenkov Telescope Array (CTA) project aims to build the largest ground-based gamma-ray observatory based on an array of Imaging Atmospheric Cherenkov Telescopes (IACTs). The CTA will implement a multi-level trigger system to distinguish between gamma ray-like induced showers and background images induced by night sky background (NSB) light. The trigger system is based on coincident detection…
▽ More
The Cherenkov Telescope Array (CTA) project aims to build the largest ground-based gamma-ray observatory based on an array of Imaging Atmospheric Cherenkov Telescopes (IACTs). The CTA will implement a multi-level trigger system to distinguish between gamma ray-like induced showers and background images induced by night sky background (NSB) light. The trigger system is based on coincident detections among pixels (level 0 trigger), clusters of pixels (level 1) or telescopes. In this article, the first version of the application specific integrated circuit (ASIC) for Level 1 trigger system is presented, capable of working with different Level 0 strategies and different trigger region sizes. In addition, it complies with all the requirements specified by the CTA project, specially the most critical ones as regards noise, bandwidth, dynamic range and power consumption. All these features make the presented system very suitable for use in the CTA cameras and improve the features of discrete components prototypes of the L1 trigger circuit in terms of compactness, noise, performance and power consumption.
△ Less
Submitted 30 October, 2014;
originally announced October 2014.
-
The camera of the fifth H.E.S.S. telescope. Part I: System description
Authors:
J. Bolmont,
P. Corona,
P. Gauron,
P. Ghislain,
C. Goffin,
L. Guevara Riveros,
J. -F. Huppert,
O. Martineau-Huynh,
P. Nayman,
J. -M. Parraud,
J. -P. Tavernet,
F. Toussenel,
D. Vincent,
P. Vincent,
W. Bertoli,
P. Espigat,
M. Punch,
D. Besin,
E. Delagnes,
J. -F. Glicenstein,
Y. Moudden,
P. Venault,
H. Zaghia,
L. Brunetti,
P. -Y. David
, et al. (32 additional authors not shown)
Abstract:
In July 2012, as the four ground-based gamma-ray telescopes of the H.E.S.S. (High Energy Stereoscopic System) array reached their tenth year of operation in Khomas Highlands, Namibia, a fifth telescope took its first data as part of the system. This new Cherenkov detector, comprising a 614.5 m^2 reflector with a highly pixelized camera in its focal plane, improves the sensitivity of the current ar…
▽ More
In July 2012, as the four ground-based gamma-ray telescopes of the H.E.S.S. (High Energy Stereoscopic System) array reached their tenth year of operation in Khomas Highlands, Namibia, a fifth telescope took its first data as part of the system. This new Cherenkov detector, comprising a 614.5 m^2 reflector with a highly pixelized camera in its focal plane, improves the sensitivity of the current array by a factor two and extends its energy domain down to a few tens of GeV.
The present part I of the paper gives a detailed description of the fifth H.E.S.S. telescope's camera, presenting the details of both the hardware and the software, emphasizing the main improvements as compared to previous H.E.S.S. camera technology.
△ Less
Submitted 26 May, 2014; v1 submitted 22 October, 2013;
originally announced October 2013.
-
Infrastructure for Detector Research and Development towards the International Linear Collider
Authors:
J. Aguilar,
P. Ambalathankandy,
T. Fiutowski,
M. Idzik,
Sz. Kulis,
D. Przyborowski,
K. Swientek,
A. Bamberger,
M. Köhli,
M. Lupberger,
U. Renz,
M. Schumacher,
Andreas Zwerger,
A. Calderone,
D. G. Cussans,
H. F. Heath,
S. Mandry,
R. F. Page,
J. J. Velthuis,
D. Attié,
D. Calvet,
P. Colas,
X. Coppolani,
Y. Degerli,
E. Delagnes
, et al. (252 additional authors not shown)
Abstract:
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infras…
▽ More
The EUDET-project was launched to create an infrastructure for develo** and testing new and advanced detector technologies to be used at a future linear collider. The aim was to make possible experimentation and analysis of data for institutes, which otherwise could not be realized due to lack of resources. The infrastructure comprised an analysis and software network, and instrumentation infrastructures for tracking detectors as well as for calorimetry.
△ Less
Submitted 23 January, 2012;
originally announced January 2012.
-
The T2K Experiment
Authors:
T2K Collaboration,
K. Abe,
N. Abgrall,
H. Aihara,
Y. Ajima,
J. B. Albert,
D. Allan,
P. -A. Amaudruz,
C. Andreopoulos,
B. Andrieu,
M. D. Anerella,
C. Angelsen,
S. Aoki,
O. Araoka,
J. Argyriades,
A. Ariga,
T. Ariga,
S. Assylbekov,
J. P. A. M. de André,
D. Autiero,
A. Badertscher,
O. Ballester,
M. Barbi,
G. J. Barker,
P. Baron
, et al. (499 additional authors not shown)
Abstract:
The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross…
▽ More
The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross section measurements and sterile neutrino searches. The experiment uses an intense proton beam generated by the J-PARC accelerator in Tokai, Japan, and is composed of a neutrino beamline, a near detector complex (ND280), and a far detector (Super-Kamiokande) located 295 km away from J-PARC. This paper provides a comprehensive review of the instrumentation aspect of the T2K experiment and a summary of the vital information for each subsystem.
△ Less
Submitted 8 June, 2011; v1 submitted 6 June, 2011;
originally announced June 2011.
-
Pattern recognition and PID for COMPASS RICH-1
Authors:
P. Abbon,
M. Alexeev,
H. Angerer,
R. Birsa,
P. Bordalo,
F. Bradamante,
A. Bressan,
M. Chiosso,
P. Ciliberti,
M. L. Colantoni,
T. Dafni,
S. Dalla Torre,
E. Delagnes,
O. Denisov,
H. Deschamps,
V. Diaz,
N. Dibiase,
V. Duic,
W. Eyrich,
A. Ferrero,
M. Finger,
M. Finger Jr,
H. Fischer,
S. Gerassimov,
M. Giorgi
, et al. (44 additional authors not shown)
Abstract:
A package for pattern recognition and PID by COMPASS RICH-1 has been developed and used for the analysis of COMPASS data collected in the years 2002 to 2004, and 2006-2007 with the upgraded RICH-1 photon detectors. It has allowed the full characterization of the detector in the starting version and in the upgraded one, as well as the PID for physics results. We report about the package structure…
▽ More
A package for pattern recognition and PID by COMPASS RICH-1 has been developed and used for the analysis of COMPASS data collected in the years 2002 to 2004, and 2006-2007 with the upgraded RICH-1 photon detectors. It has allowed the full characterization of the detector in the starting version and in the upgraded one, as well as the PID for physics results. We report about the package structure and algorithms, and the detector characterization and PID results.
△ Less
Submitted 3 February, 2009;
originally announced February 2009.
-
The Micromegas detector of the CAST experiment
Authors:
P. Abbon,
S. Andriamonje,
S. Aune,
T. Dafni,
M. Davenport,
E. Delagnes,
R. de Oliveira,
G. Fanourakis,
E. Ferrer Ribas,
J. Franz,
T. Geralis,
M. Gros,
Y. Giomataris,
I. G. Irastorza,
K. Kousouris,
J. Morales,
T. Papaevangelou,
J. Ruz,
K. Zachariadou,
K. Zioutas
Abstract:
A low background Micromegas detector has been operating in the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector, made out of low radioactivity materials, operated efficiently and achieved a very low level of background rejection (5 x 10^-5 counts/keV/cm^2/s) without shielding.
A low background Micromegas detector has been operating in the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector, made out of low radioactivity materials, operated efficiently and achieved a very low level of background rejection (5 x 10^-5 counts/keV/cm^2/s) without shielding.
△ Less
Submitted 22 February, 2007;
originally announced February 2007.
-
IDeF-X ASIC for Cd(Zn)Te spectro-imaging systems
Authors:
O. Limousin,
O. Gevin,
F. Lugiez,
R. Chipaux,
E. Delagnes,
B. Dirks,
B. Horeau
Abstract:
Joint progresses in Cd(Zn)Te detectors, microelectronics and interconnection technologies open the way for a new generation of instruments for physics and astrophysics applications in the energy range from 1 to 1000 keV. Even working between -20 and 20 degrees Celsius, these instruments will offer high spatial resolution (pixel size ranging from 300 x 300 square micrometers to few square millime…
▽ More
Joint progresses in Cd(Zn)Te detectors, microelectronics and interconnection technologies open the way for a new generation of instruments for physics and astrophysics applications in the energy range from 1 to 1000 keV. Even working between -20 and 20 degrees Celsius, these instruments will offer high spatial resolution (pixel size ranging from 300 x 300 square micrometers to few square millimeters), high spectral response and high detection efficiency. To reach these goals, reliable, highly integrated, low noise and low power consumption electronics is mandatory. Our group is currently develo** a new ASIC detector front-end named IDeF-X, for modular spectro-imaging system based on the use of Cd(Zn)Te detectors. We present here the first version of IDeF-X which consists in a set of ten low noise charge sensitive preamplifiers (CSA). It has been processed with the standard AMS 0.35 micrometer CMOS technology. The CSA are designed to be DC coupled to detectors having a low dark current at room temperature. The various preamps implemented are optimized for detector capacitances ranging from 0.5 up to 30 pF.
△ Less
Submitted 24 November, 2004; v1 submitted 19 November, 2004;
originally announced November 2004.