Correcting Aberrations of a Transverse-Field Neutron Resonance Spin Echo Instrument
Authors:
Stephen J. Kuhn,
Sam McKay,
Fankang Li,
Robert M. Dalgliesh,
Eric Dees,
Kaleb Burrage,
Jiazhou Shen,
Roger Pynn
Abstract:
The neutron resonance spin echo (NRSE) technique has the potential to increase the Fourier time and energy resolution in neutron scattering by using radio-frequency (rf) neutron spin-flippers. However, aberrations arising from variations in the neutron path length between the rf flippers reduce the polarization. Here, we develop and test a transverse static-field magnet, a series of which are plac…
▽ More
The neutron resonance spin echo (NRSE) technique has the potential to increase the Fourier time and energy resolution in neutron scattering by using radio-frequency (rf) neutron spin-flippers. However, aberrations arising from variations in the neutron path length between the rf flippers reduce the polarization. Here, we develop and test a transverse static-field magnet, a series of which are placed between the rf flippers, to correct for these aberrations. The prototype correction magnet was both simulated in an NRSE beamline using McStas, a Monte Carlo neutron ray-tracing software package, and measured using neutrons. The results from the prototype demonstrate that this static-field design corrects for transverse-field NRSE aberrations.
△ Less
Submitted 23 September, 2022;
originally announced September 2022.
-
Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment
Authors:
B. Plaster,
E. Adamek,
B. Allgeier,
J. Anaya,
H. O. Back,
Y. Bagdasarova,
D. B. Berguno,
M. Blatnik,
J. G. Boissevain,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
D. J. Clark,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
S. Du,
B. W. Filippone,
A. Garcia,
P. Geltenbort,
S. Hasan,
A. Hawari
, et al. (69 additional authors not shown)
Abstract:
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the…
▽ More
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.
△ Less
Submitted 10 April, 2019;
originally announced April 2019.
-
Monte Carlo Simulations of Trapped Ultracold Neutrons in the UCNτ Experiment
Authors:
Nathan Callahan,
Chen-Yu Liu,
Francisco Gonzalez,
Evan Adamek,
James David Bowman,
Leah Broussard,
S. M. Clayton,
S. Currie,
C. Cude-Woods,
E. B. Dees,
X. Ding,
E. M. Egnel,
D. Fellers,
W. Fox,
P. Geltenbort,
K. P. Hickerson,
M. A. Hoffbauer,
A. T. Holley,
A. Komives,
S. W. T. MacDonald,
M. Makela,
C. L. Morris,
J. D. Ortiz,
R. W. Pattie Jr,
J. Ramsey
, et al. (15 additional authors not shown)
Abstract:
In the UCNτ experiment, ultracold neutrons (UCN) are confined by magnetic fields and the Earth's gravitational field. Field-trap** mitigates the problem of UCN loss on material surfaces, which caused the largest correction in prior neutron experiments using material bottles. However, the neutron dynamics in field traps differ qualitatively from those in material bottles. In the latter case, neut…
▽ More
In the UCNτ experiment, ultracold neutrons (UCN) are confined by magnetic fields and the Earth's gravitational field. Field-trap** mitigates the problem of UCN loss on material surfaces, which caused the largest correction in prior neutron experiments using material bottles. However, the neutron dynamics in field traps differ qualitatively from those in material bottles. In the latter case, neutrons bounce off material surfaces with significant diffusivity and the population quickly reaches a static spatial distribution with a density gradient induced by the gravitational potential. In contrast, the field-confined UCN -- whose dynamics can be described by Hamiltonian mechanics -- do not exhibit the stochastic behaviors typical of an ideal gas model as observed in material bottles. In this report, we will describe our efforts to simulate UCN trap** in the UCNτ magneto-gravitational trap. We compare the simulation output to the experimental results to determine the parameters of the neutron detector and the input neutron distribution. The tuned model is then used to understand the phase space evolution of neutrons observed in the UCNτ experiment. We will discuss the implications of chaotic dynamics on controlling the systematic effects, such as spectral cleaning and microphonic heating, for a successful UCN lifetime experiment to reach a 0.01% level of precision.
△ Less
Submitted 16 October, 2018;
originally announced October 2018.
-
Search for dark matter decay of the free neutron from the UCNA experiment: n $\rightarrow χ+ e^+e^-$
Authors:
X. Sun,
E. Adamek,
B. Allgeier,
M. Blatnik,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
B. W. Filippone,
A. García,
P. Geltenbort,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
R. Hong,
G. E. Hogan,
A. T. Holley,
T. M. Ito,
A. Knecht,
C. -Y. Liu
, et al. (35 additional authors not shown)
Abstract:
It has been proposed recently that a previously unobserved neutron decay branch to a dark matter particle ($χ$) could account for the discrepancy in the neutron lifetime observed in experiments that use two different measurement techniques. One of the possible final states discussed includes a single $χ$ along with an $e^{+}e^{-}$ pair. We use data from the UCNA (Ultracold Neutron Asymmetry) exper…
▽ More
It has been proposed recently that a previously unobserved neutron decay branch to a dark matter particle ($χ$) could account for the discrepancy in the neutron lifetime observed in experiments that use two different measurement techniques. One of the possible final states discussed includes a single $χ$ along with an $e^{+}e^{-}$ pair. We use data from the UCNA (Ultracold Neutron Asymmetry) experiment to set limits on this decay channel. Coincident electron-like events are detected with $\sim 4π$ acceptance using a pair of detectors that observe a volume of stored Ultracold Neutrons (UCNs). The summed kinetic energy ($E_{e^{+}e^{-}}$) from such events is used to set limits, as a function of the $χ$ mass, on the branching fraction for this decay channel. For $χ$ masses consistent with resolving the neutron lifetime discrepancy, we exclude this as the dominant dark matter decay channel at $\gg~5σ$ level for $100~\text{keV} < E_{e^{+}e^{-}} < 644~\text{keV}$. If the $χ+e^{+}e^{-}$ final state is not the only one, we set limits on its branching fraction of $< 10^{-4}$ for the above $E_{e^{+}e^{-}}$ range at $> 90\%$ confidence level.
△ Less
Submitted 28 March, 2018;
originally announced March 2018.
-
Detection System for Neutron $β$ Decay Correlations in the UCNB and Nab experiments
Authors:
L. J. Broussard,
B. A. Zeck,
E. R. Adamek,
S. Baeßler,
N. Birge,
M. Blatnik,
J. D. Bowman,
A. E. Brandt,
M. Brown,
J. Burkhart,
N. B. Callahan,
S. M. Clayton,
C. Crawford,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
N. Fomin,
E. Frlez,
J. Fry,
F. E. Gray,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
A. T. Holley
, et al. (29 additional authors not shown)
Abstract:
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise…
▽ More
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise time of $\sim$50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of $β$ particles and recoil protons from neutron $β$ decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments, to determine the neutron $β$ decay parameters $B$, $a$, and $b$.
△ Less
Submitted 7 January, 2017; v1 submitted 9 July, 2016;
originally announced July 2016.
-
Position-sensitive detection of ultracold neutrons with an imaging camera and its implications to spectroscopy
Authors:
Wanchun Wei,
L. J. Broussard,
M. A. Hoffbauer,
M. Makela,
C. L. Morris,
Z. Tang,
E. R. Adamek,
N. B. Callahan,
S. M. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
P. Geltenbort,
K. P. Hickerson,
A. T. Holley,
T. M. Ito,
K. K. Leung,
C. -Y. Liu,
D. J. Morley,
Jose D. Ortiz,
R. W. Pattie, Jr.,
J. C. Ramsey,
A. Saunders,
S. J. Seestrom
, et al. (7 additional authors not shown)
Abstract:
Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15 $μ$m has been achieved, which is equivalent to an UCN energy resolution below 2 pico-electron-volts through the relation $δE = m_0g δx$. Here, the symbols $δE$, $δx$, $m_0$ and $g$ are the energy resolution, the spatial resolution, the neu…
▽ More
Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15 $μ$m has been achieved, which is equivalent to an UCN energy resolution below 2 pico-electron-volts through the relation $δE = m_0g δx$. Here, the symbols $δE$, $δx$, $m_0$ and $g$ are the energy resolution, the spatial resolution, the neutron rest mass and the gravitational acceleration, respectively. A multilayer surface convertor described previously is used to capture UCNs and then emits visible light for CCD imaging. Particle identification and noise rejection are discussed through the use of light intensity profile analysis. This method allows different types of UCN spectroscopy and other applications.
△ Less
Submitted 12 May, 2016; v1 submitted 27 April, 2016;
originally announced April 2016.
-
A multilayer surface detector for ultracold neutrons
Authors:
Zhehui Wang,
M. A. Hoffbauer,
C. L. Morris,
N. B. Callahan,
E. R. Adamek,
J. D. Bacon,
M. Blatnik,
A. E. Brandt,
L. J. Broussard,
S. M. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
J. Gao,
F. E. Gray,
K. P. Hickerson,
A. T. Holley,
T. M. Ito,
C. -Y. Liu,
M. Makela,
J. C. Ramsey,
R. W. Pattie, Jr.,
D. J. Salvat,
A. Saunders
, et al. (11 additional authors not shown)
Abstract:
A multilayer surface detector for ultracold neutrons (UCNs) is described. The top $^{10}$B layer is exposed to the vacuum chamber and directly captures UCNs. The ZnS:Ag layer beneath the $^{10}$B layer is a few microns thick, which is sufficient to detect the charged particles from the $^{10}$B(n,$α$)$^7$Li neutron-capture reaction, while thin enough so that ample light due to $α$ and $^7$Li escap…
▽ More
A multilayer surface detector for ultracold neutrons (UCNs) is described. The top $^{10}$B layer is exposed to the vacuum chamber and directly captures UCNs. The ZnS:Ag layer beneath the $^{10}$B layer is a few microns thick, which is sufficient to detect the charged particles from the $^{10}$B(n,$α$)$^7$Li neutron-capture reaction, while thin enough so that ample light due to $α$ and $^7$Li escapes for detection by photomultiplier tubes. One-hundred-nm thick $^{10}$B layer gives high UCN detection efficiency, as determined by the mean UCN kinetic energy, detector materials and others. Low background, including negligible sensitivity to ambient neutrons, has also been verified through pulse-shape analysis and comparisons with other existing $^3$He and $^{10}$B detectors. This type of detector has been configured in different ways for UCN flux monitoring, development of UCN guides and neutron lifetime research.
△ Less
Submitted 24 April, 2015; v1 submitted 11 March, 2015;
originally announced March 2015.
-
Neutron-Antineutron Oscillations: Theoretical Status and Experimental Prospects
Authors:
D. G. Phillips II,
W. M. Snow,
K. Babu,
S. Banerjee,
D. V. Baxter,
Z. Berezhiani,
M. Bergevin,
S. Bhattacharya,
G. Brooijmans,
L. Castellanos,
M-C. Chen,
C. E. Coppola,
R. Cowsik,
J. A. Crabtree,
P. Das,
E. B. Dees,
A. Dolgov,
P. D. Ferguson,
M. Frost,
T. Gabriel,
A. Gal,
F. Gallmeier,
K. Ganezer,
E. Golubeva,
G. Greene
, et al. (38 additional authors not shown)
Abstract:
This paper summarizes the relevant theoretical developments, outlines some ideas to improve experimental searches for free neutron-antineutron oscillations, and suggests avenues for future improvement in the experimental sensitivity.
This paper summarizes the relevant theoretical developments, outlines some ideas to improve experimental searches for free neutron-antineutron oscillations, and suggests avenues for future improvement in the experimental sensitivity.
△ Less
Submitted 18 October, 2015; v1 submitted 4 October, 2014;
originally announced October 2014.
-
Neutron-Antineutron Oscillations: A Snowmass 2013 White Paper
Authors:
K. Babu,
S. Banerjee,
D. V. Baxter,
Z. Berezhiani,
M. Bergevin,
S. Bhattacharya,
S. Brice,
T. W. Burgess,
L. Castellanos,
S. Chattopadhyay,
M-C. Chen,
C. E. Coppola,
R. Cowsik,
J. A. Crabtree,
P. Das,
E. B. Dees,
A. Dolgov,
G. Dvali,
P. Ferguson,
M. Frost,
T. Gabriel,
A. Gal,
F. Gallmeier,
K. Ganezer,
E. Golubeva
, et al. (47 additional authors not shown)
Abstract:
This paper summarizes discussions of the theoretical developments and the studies performed by the NNbarX collaboration for the 2013 Snowmass Community Summer Study.
This paper summarizes discussions of the theoretical developments and the studies performed by the NNbarX collaboration for the 2013 Snowmass Community Summer Study.
△ Less
Submitted 31 October, 2013;
originally announced October 2013.
-
Storage of ultracold neutrons in the UCN$τ$ magneto-gravitational trap
Authors:
D. J. Salvat,
E. R. Adamek,
D. Barlow,
L. J. Broussard,
J. D. Bowman,
N. B. Callahan,
S. M. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
W. Fox,
P. Geltenbort,
K. P. Hickerson,
A. T. Holley,
C. -Y. Liu,
M. Makela,
J. Medina,
D. J. Morley,
C. L. Morris,
S. I. Penttila,
J. Ramsey,
A. Saunders,
S. J. Seestrom,
S. K. L. Sjue,
B. A. Slaughter
, et al. (7 additional authors not shown)
Abstract:
The UCN$τ$ experiment is designed to measure the lifetime $τ_{n}$ of the free neutron by trap** ultracold neutrons (UCN) in a magneto-gravitational trap. An asymmetric bowl-shaped NdFeB magnet Halbach array confines low-field-seeking UCN within the apparatus, and a set of electromagnetic coils in a toroidal geometry provide a background "holding" field to eliminate depolarization-induced UCN los…
▽ More
The UCN$τ$ experiment is designed to measure the lifetime $τ_{n}$ of the free neutron by trap** ultracold neutrons (UCN) in a magneto-gravitational trap. An asymmetric bowl-shaped NdFeB magnet Halbach array confines low-field-seeking UCN within the apparatus, and a set of electromagnetic coils in a toroidal geometry provide a background "holding" field to eliminate depolarization-induced UCN loss caused by magnetic field nodes. We present a measurement of the storage time $τ_{store}$ of the trap by storing UCN for various times, and counting the survivors. The data are consistent with a single exponential decay, and we find $τ_{store}=860\pm19$ s: within $1 σ$ of current global averages for $τ_{n}$. The storage time with the holding field deactiveated is found to be $τ_{store}=470 \pm 160$ s; this decreased storage time is due to the loss of UCN which undergo Majorana spin-flips while being stored. We discuss plans to increase the statistical sensitivity of the measurement and investigate potential systematic effects.
△ Less
Submitted 31 October, 2013; v1 submitted 21 October, 2013;
originally announced October 2013.