-
Tunable Isolated Attosecond X-ray Pulses with Gigawatt Peak Power from a Free-Electron Laser
Authors:
Joseph Duris,
Siqi Li,
Taran Driver,
Elio G. Champenois,
James P. MacArthur,
Alberto A. Lutman,
Zhen Zhang,
Philipp Rosenberger,
Jeff W. Aldrich,
Ryan Coffee,
Giacomo Coslovich,
Franz-Josef Decker,
James M. Glownia,
Gregor Hartmann,
Wolfram Helml,
Andrei Kamalov,
Jonas Knurr,
Jacek Krzywinski,
Ming-Fu Lin,
Megan Nantel,
Adi Natan,
Jordan O'Neal,
Niranjan Shivaram,
Peter Walter,
Anna Wang
, et al. (9 additional authors not shown)
Abstract:
The quantum mechanical motion of electrons in molecules and solids occurs on the sub-femtosecond timescale. Consequently, the study of ultrafast electronic phenomena requires the generation of laser pulses shorter than 1 fs and of sufficient intensity to interact with their target with high probability. Probing these dynamics with atomic-site specificity requires the extension of sub-femtosecond p…
▽ More
The quantum mechanical motion of electrons in molecules and solids occurs on the sub-femtosecond timescale. Consequently, the study of ultrafast electronic phenomena requires the generation of laser pulses shorter than 1 fs and of sufficient intensity to interact with their target with high probability. Probing these dynamics with atomic-site specificity requires the extension of sub-femtosecond pulses to the soft X-ray spectral region. Here we report the generation of isolated GW-scale soft X-ray attosecond pulses with an X-ray free-electron laser. Our source has a pulse energy that is six orders of magnitude larger than any other source of isolated attosecond pulses in the soft X-ray spectral region, with a peak power in the tens of gigawatts. This unique combination of high intensity, high photon energy and short pulse duration enables the investigation of electron dynamics with X-ray non-linear spectroscopy and single-particle imaging.
△ Less
Submitted 25 June, 2019;
originally announced June 2019.
-
Very high brightness and power LCLS-II hard X-ray pulses
Authors:
Aliaksei Halavanau,
Franz-Josef Decker,
Claudio Emma,
Jackson Sheppard,
Claudio Pellegrini
Abstract:
We show the feasibility of generating X-ray pulses in the 4 to 8 keV fundamental photon energy range with 0.65 TW peak power, 15 fs pulse duration, $9\times10^{-5}$ bandwidth, using the LCLS-II copper linac and hard X-ray (HXR) undulator. Third harmonic pulses with 8-12 GW peak power and narrow bandwidth are also generated. High power and small bandwidth X-rays are obtained using two electron bunc…
▽ More
We show the feasibility of generating X-ray pulses in the 4 to 8 keV fundamental photon energy range with 0.65 TW peak power, 15 fs pulse duration, $9\times10^{-5}$ bandwidth, using the LCLS-II copper linac and hard X-ray (HXR) undulator. Third harmonic pulses with 8-12 GW peak power and narrow bandwidth are also generated. High power and small bandwidth X-rays are obtained using two electron bunches separated by about 1 ns, one to generate a high power seed signal, the other to amplify it by tapering the magnetic field of the HXR undulator. The bunch delay is compensated by delaying the seed pulse with a four crystals monochromator. The high power seed leads to higher output power and better spectral properties, with $>$94\% of the X-ray power being within the near transform limited bandwidth. We discuss some of the experiments made possible by X-ray pulses with these characteristics, like single particle imaging and high field physics.
△ Less
Submitted 19 February, 2019; v1 submitted 11 December, 2018;
originally announced December 2018.
-
Direct Experimental Observation of the Gas Filamentation Effect using a Two-bunch X-ray FEL Beam
Authors:
Y. Feng,
D. W. Schafer,
S. Song,
Y. Sun,
D. Zhu,
J. Krzywinski,
A. Robert,
J. Wu,
F. -J. Decker
Abstract:
We report the experimental observation of the filamentation effect in gas devices designed for X-ray Free-electron Lasers. The measurements were carried out at the Linac Coherent Light Source on the X-ray Correlation Spectroscopy (XCS) instrument using a Two-bunch FEL beam at 6.5 keV with 122.5 ns separation passing through an Argon gas cell. The relative intensities of the two pulses of the Two-b…
▽ More
We report the experimental observation of the filamentation effect in gas devices designed for X-ray Free-electron Lasers. The measurements were carried out at the Linac Coherent Light Source on the X-ray Correlation Spectroscopy (XCS) instrument using a Two-bunch FEL beam at 6.5 keV with 122.5 ns separation passing through an Argon gas cell. The relative intensities of the two pulses of the Two-bunch beam were measured, after and before the gas cell, from the X-ray scattering off thin targets by using fast diodes with sufficient temporal resolution. It was found that the after-to-before ratio of the intensities of the second pulse was consistently higher than that of the first pulse, revealing lower effective attenuation of the gas cell due to the heating and subsequent gas density reduction in the beam path by the first pulse. This measurement is important in guiding the design and/or mitigating the adverse effect in gas devices for high repetition-rate FELs such as the LCLS-II and the European XFEL or other future high repetition-rate upgrade to existing FEL facilities
△ Less
Submitted 27 May, 2017;
originally announced June 2017.
-
Undulator-Based Production of Polarized Positrons
Authors:
Gideon Alexander,
John Barley,
Yuri Batygin,
Steven Berridge,
Vinod Bharadwaj,
Gary Bower,
William Bugg,
Franz-Josef Decker,
Ralph Dollan,
Yuri Efremenko,
Klaus Floettmann,
Vahagn Gharibyan,
Carsten Hast,
Richard Iverson,
Hermann Kolanoski,
Jan W. Kovermann,
Karim Laihem,
Thomas Lohse,
Kirk T. McDonald,
Alexander A. Mikhailichenko,
Gudrid Moortgat-Pick,
Philipp Pahl,
Rainer Pitthan,
Roman Poeschl,
Erez Reinherz-Aronis
, et al. (10 additional authors not shown)
Abstract:
Full exploitation of the physics potential of a future International Linear Collider will require the use of polarized electron and positron beams. Experiment E166 at the Stanford Linear Accelerator Center (SLAC) has demonstrated a scheme in which an electron beam passes through a helical undulator to generate photons (whose first-harmonic spectrum extended to 7.9MeV) with circular polarization,…
▽ More
Full exploitation of the physics potential of a future International Linear Collider will require the use of polarized electron and positron beams. Experiment E166 at the Stanford Linear Accelerator Center (SLAC) has demonstrated a scheme in which an electron beam passes through a helical undulator to generate photons (whose first-harmonic spectrum extended to 7.9MeV) with circular polarization, which are then converted in a thin target to generate longitudinally polarized positrons and electrons. The experiment was carried out with a one-meter-long, 400-period, pulsed helical undulator in the Final Focus Test Beam (FFTB) operated at 46.6GeV. Measurements of the positron polarization have been performed at five positron energies from 4.5 to 7.5MeV. In addition, the electron polarization has been determined at 6.7MeV, and the effect of operating the undulator with a ferrofluid was also investigated. To compare the measurements with expectations, detailed simulations were made with an upgraded version of Geant4 that includes the dominant polarization-dependent interactions of electrons, positrons, and photons with matter. The measurements agree with calculations, corresponding to 80% polarization for positrons near 6MeV and 90% for electrons near 7MeV.
△ Less
Submitted 19 May, 2009;
originally announced May 2009.
-
Transverse emittance measurements on an S-band photoinjector rf electron gun
Authors:
J. F. Schmerge,
P. R. Bolton,
J. E. Clendenin,
F. -J. Decker,
D. H. Dowell,
S. M. Gierman,
C. G. Limborg,
B. F. Murphy
Abstract:
Proposed fourth generation light sources using SASE FELs to generate short pulse, coherent, X-rays require demonstration of high brightness electron sources. The Gun Test Facility (GTF) at SLAC was built to test high brightness sources for the proposed Linac Coherent Light Source at SLAC. The transverse emittance measurements are made at nearly 30 MeV by measuring the spot size on a YAG screen u…
▽ More
Proposed fourth generation light sources using SASE FELs to generate short pulse, coherent, X-rays require demonstration of high brightness electron sources. The Gun Test Facility (GTF) at SLAC was built to test high brightness sources for the proposed Linac Coherent Light Source at SLAC. The transverse emittance measurements are made at nearly 30 MeV by measuring the spot size on a YAG screen using the quadrupole scan technique. The emittance was measured to vary from 1 to 3.5 mm-mrad as the charge is increased from 50 to 350 pC using a laser pulse width of 2 ps FWHM. The measurements are in good agreement with simulation results using the LANL version of PARMELA.
△ Less
Submitted 3 November, 2001;
originally announced November 2001.
-
Observation of Plasma Focusing of a 28.5 GeV Positron Beam
Authors:
J. S. T. Ng,
P. Chen,
H. Baldis,
P. Bolton,
D. Cline,
W. Craddock,
C. Crawford,
F. J. Decker,
C. Field,
Y. Fukui,
V. Kumar,
R. Iverson,
F. King,
R. E. Kirby,
K. Nakajima,
R. Noble,
A. Ogata,
P. Raimondi,
D. Walz,
A. W. Weidemann
Abstract:
The observation of plasma focusing of a 28.5 GeV positron beam is reported. The plasma was formed by ionizing a nitrogen jet only 3 mm thick. Simultaneous focusing in both transverse dimensions was observed with effective focusing strengths of order Tesla per micron. The minimum area of the beam spot was reduced by a factor of 2.0 +/- 0.3 by the plasma. The longitudinal beam envelope was measure…
▽ More
The observation of plasma focusing of a 28.5 GeV positron beam is reported. The plasma was formed by ionizing a nitrogen jet only 3 mm thick. Simultaneous focusing in both transverse dimensions was observed with effective focusing strengths of order Tesla per micron. The minimum area of the beam spot was reduced by a factor of 2.0 +/- 0.3 by the plasma. The longitudinal beam envelope was measured and compared with numerical calculations.
△ Less
Submitted 4 October, 2001;
originally announced October 2001.
-
Results on Plasma Focusing of High Energy Density Electron and Positron Beams
Authors:
J. S. T. Ng,
P. Chen,
W. Craddock,
F. J. Decker,
R. C. Field,
M. J. Hogan,
R. Iverson,
F. King,
R. E. Kirby,
T. Kotseroglou,
P. Raimondi,
D. Walz,
H. A. Baldis,
P. Bolton,
D. Cline,
Y. Fukui,
V. Kumar,
C. Crawford,
R. Noble,
K. Nakajima,
A. Ogata,
A. W. Weidemann
Abstract:
We present results from the SLAC E-150 experiment on plasma focusing of high energy density electron and, for the first time, positron beams. We also discuss measurements on plasma lens-induced synchrotron radiation, longitudinal dynamics of plasma focusing, and laser- and beam-plasma interactions.
We present results from the SLAC E-150 experiment on plasma focusing of high energy density electron and, for the first time, positron beams. We also discuss measurements on plasma lens-induced synchrotron radiation, longitudinal dynamics of plasma focusing, and laser- and beam-plasma interactions.
△ Less
Submitted 18 August, 2000;
originally announced August 2000.
-
Upgrade of the PEP-II Low Beta Optics
Authors:
Y. Nosochkov,
M. Biagini,
Y. Cai,
F. -J. Decker,
M. H. R. Donald,
S. Ecklund,
A. Fisher,
W. Kozanecki,
P. Krejcik,
A. Kulikov,
M. Minty,
I. Reichel,
J. Seeman,
M. Sullivan,
U. Wienands,
Y. Yan
Abstract:
The successful commissioning and operation of the PEP-II asymmetric e+e- collider motivated further studies to increase luminosity. In this paper, we discuss a modification of the PEP-II lattice to reduce the vertical beta function at the Interaction Point (IP) from the design value of 1.5cm to 1.0cm. This could potentially reduce the colliding beam size, increase particle density at the IP and…
▽ More
The successful commissioning and operation of the PEP-II asymmetric e+e- collider motivated further studies to increase luminosity. In this paper, we discuss a modification of the PEP-II lattice to reduce the vertical beta function at the Interaction Point (IP) from the design value of 1.5cm to 1.0cm. This could potentially reduce the colliding beam size, increase particle density at the IP and the probability of beam-beam interactions. In this paper, we outline the optics modifications, discuss tracking simulations, and overview machine implementation.
△ Less
Submitted 29 June, 2000;
originally announced June 2000.