Modeling the microscopic electrical properties of thrombin binding aptamer (TBA) for label-free biosensors
Authors:
Eleonora Alfinito,
Lino Reggiani,
Rosella Cataldo,
Giorgio De Nunzio,
Livia Giotta,
Maria Rachele Guascito
Abstract:
Aptamers are chemically produced oligonucleotides, able to bind a variety of targets such as drugs, proteins and pathogens with high sensitivity and selectivity. Therefore, aptamers are largely employed for producing label-free biosensors, with significant applications in diagnostics and drug delivery. In particular, the anti-thrombin aptamers are biomolecules of high interest for clinical use, be…
▽ More
Aptamers are chemically produced oligonucleotides, able to bind a variety of targets such as drugs, proteins and pathogens with high sensitivity and selectivity. Therefore, aptamers are largely employed for producing label-free biosensors, with significant applications in diagnostics and drug delivery. In particular, the anti-thrombin aptamers are biomolecules of high interest for clinical use, because of their ability to recognize and bind the thrombin enzyme. Among them, the DNA 15-mer thrombin-binding aptamer (TBA), has been widely explored concerning both its structure, which was resolved with different techniques, and its function, especially about the possibility of using it as the active part of biosensors. This paper proposes a microscopic model of the electrical properties of TBA and the aptamer-thrombin complex, combining information from both structure and function. The novelty consists in describing both the aptamer alone and the complex as an impedance network, thus going deeper inside the issues addressed in an emerging electronics branch known as proteotronics. The theoretical results are compared and validated with Electrochemical Impedance Spectroscopy measurements reported in the literature. Finally, the model suggests resistance measurements as a novel tool for testing aptamer-target affinity.
△ Less
Submitted 12 July, 2016;
originally announced August 2016.
-
Automated detection of lung nodules in low-dose computed tomography
Authors:
D. Cascio,
S. C. Cheran,
A. Chincarini,
G. De Nunzio,
P. Delogu,
M. E. Fantacci,
G. Gargano,
I. Gori,
G. L. Masala,
A. Preite Martinez,
A. Retico,
M. Santoro,
C. Spinelli,
T. Tarantino
Abstract:
A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector computed-tomography (CT) images has been developed in the framework of the MAGIC-5 Italian project. One of the main goals of this project is to build a distributed database of lung CT scans in order to enable automated image analysis through a data and cpu GRID infrastructure. The basic…
▽ More
A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector computed-tomography (CT) images has been developed in the framework of the MAGIC-5 Italian project. One of the main goals of this project is to build a distributed database of lung CT scans in order to enable automated image analysis through a data and cpu GRID infrastructure. The basic modules of our lung-CAD system, consisting in a 3D dot-enhancement filter for nodule detection and a neural classifier for false-positive finding reduction, are described. The system was designed and tested for both internal and sub-pleural nodules. The database used in this study consists of 17 low-dose CT scans reconstructed with thin slice thickness (~300 slices/scan). The preliminary results are shown in terms of the FROC analysis reporting a good sensitivity (85% range) for both internal and sub-pleural nodules at an acceptable level of false positive findings (1-9 FP/scan); the sensitivity value remains very high (75% range) even at 1-6 FP/scan
△ Less
Submitted 18 July, 2007;
originally announced July 2007.
-
Lung Nodule Detection in Screening Computed Tomography
Authors:
I. Gori,
R. Bellotti,
P. Cerello,
S. C. Cheran,
G. De Nunzio,
M. E. Fantacci,
P. Kasae,
G. L. Masala,
A. Preite Martinez,
A. Retico
Abstract:
A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector helical Computed Tomography (CT) images with 1.25 mm slice thickness is presented. The basic modules of our lung-CAD system, a dot-enhancement filter for nodule candidate selection and a neural classifier for false-positive finding reduction, are described. The results obtained on the c…
▽ More
A computer-aided detection (CAD) system for the identification of pulmonary nodules in low-dose multi-detector helical Computed Tomography (CT) images with 1.25 mm slice thickness is presented. The basic modules of our lung-CAD system, a dot-enhancement filter for nodule candidate selection and a neural classifier for false-positive finding reduction, are described. The results obtained on the collected database of lung CT scans are discussed.
△ Less
Submitted 15 January, 2007;
originally announced January 2007.
-
Pre-processing methods for nodule detection in lung CT
Authors:
S. C. Cheran,
P. Delogu,
I. De Mitri,
G. De Nunzio,
M. E. Fantacci,
F. Fauci,
G. Gargano,
E. Lopez Torres,
R. Massafra,
P. Oliva,
A. Preite Martinez,
G. Raso,
A. Retico,
S. Stumbo,
A. Tata
Abstract:
The use of automatic systems in the analysis of medical images has proven to be very useful to radiologists, especially in the framework of screening programs, in which radiologists make their first diagnosis on the basis of images only, most of those corresponding to healthy patients, and have to distinguish pathological findings from non-pathological ones at an early stage. In particular, we a…
▽ More
The use of automatic systems in the analysis of medical images has proven to be very useful to radiologists, especially in the framework of screening programs, in which radiologists make their first diagnosis on the basis of images only, most of those corresponding to healthy patients, and have to distinguish pathological findings from non-pathological ones at an early stage. In particular, we are develo** preprocessing methods to be applied for pulmonary nodule Computer Aided Detection in low-dose lung Multi Slice CT (Computed Tomography) images.
△ Less
Submitted 20 July, 2005;
originally announced July 2005.