-
Robust Parahydrogen-Induced Polarization at High Concentrations
Authors:
Laurynas Dagys,
Martin C. Korzeczek,
Anna J. Parker,
James Eills,
John W. Blanchard,
Christian Bengs,
Malcolm H. Levitt,
Stephan Knecht,
Ilai Schwartz,
M. B. Plenio
Abstract:
Parahydrogen-Induced Polarization (PHIP) is a potent technique for generating target molecules with high nuclear spin polarization. The PHIP process involves a chemical reaction between parahydrogen and a target molecule, followed by the transformation of nuclear singlet spin order into magnetization of a designated nucleus through magnetic field manipulations. Although the singlet-to-magnetizatio…
▽ More
Parahydrogen-Induced Polarization (PHIP) is a potent technique for generating target molecules with high nuclear spin polarization. The PHIP process involves a chemical reaction between parahydrogen and a target molecule, followed by the transformation of nuclear singlet spin order into magnetization of a designated nucleus through magnetic field manipulations. Although the singlet-to-magnetization polarization transfer process works effectively at moderate concentrations, it is observed to become much less efficient at high molar polarization, defined as the product of polarization and concentration. This strong dependence on the molar polarization is attributed to interference from the field produced by the sample's magnetization during polarization transfer, which leads to complex dynamics and can severely impact the scalability of the technique. We address this challenge with a pulse sequence that negates the influence of the distant dipolar field, while simultaneously achieving singlet-to-magnetization polarization transfer to the desired target spins, free from restrictions on the molar polarization.
△ Less
Submitted 14 January, 2024;
originally announced January 2024.
-
Hyperpolarization read-out through rapidly rotating fields in the zero- and low-field regime
Authors:
Laurynas Dagys,
Christian Bengs
Abstract:
An integral part of para-hydrogen induced polarization (PHIP) methods is the conversion of nuclear singlet order into observable magnetization. In this study polarisation transfer to a heteronucleus is achieved through a selective rotation of the proton singlet-triplet states driven by a combination of a rotating magnetic field and a weak bias field. Surprisingly we find that efficient polarisatio…
▽ More
An integral part of para-hydrogen induced polarization (PHIP) methods is the conversion of nuclear singlet order into observable magnetization. In this study polarisation transfer to a heteronucleus is achieved through a selective rotation of the proton singlet-triplet states driven by a combination of a rotating magnetic field and a weak bias field. Surprisingly we find that efficient polarisation transfer driven by a STORM (Singlet-Triplet Oscillations through Rotating Magnetic fields) pulse in the presence of $μ$T bias fields requires rotation frequencies on the order of several kHz. The rotation frequencies therefore greatly exceed any of the internal frequencies of typical zero- to ultralow field experiments. We further show that the rotational direction of the rotating field is not arbitrary and greatly influences the final transfer efficiency. Some of these aspects are demonstrated experimentally by considering hyperpolarised (1-$^{13}$C)fumarate. In addition, we provide numerical simulations highlighting the resilience of the STORM pulse against disruptive quadrupolar coupling partners. In contrast to most of the existing methods, the STORM procedure therefore represents a promising candidate for quadrupolar decoupled polarisation transfer in PHIP experiments.
△ Less
Submitted 9 February, 2022;
originally announced February 2022.
-
Direct Production of A Hyperpolarized Metabolite on a Microfluidic Chip
Authors:
Sylwia J Barker,
Laurynas Dagys,
William Hale,
Barbara Ripka,
James Eills,
Manvendra Sharma,
Malcolm H Levitt,
Marcel Utz
Abstract:
Microfluidic systems hold great potential for the study of live microscopic cultures of cells, tissue samples, and small organisms. Integration of hyperpolarisation would enable quantitative studies of metabolism in such volume limited systems by high-resolution NMR spectroscopy. We demonstrate, for the first time, the integrated generation and detection of a hyperpolarised metabolite on a microfl…
▽ More
Microfluidic systems hold great potential for the study of live microscopic cultures of cells, tissue samples, and small organisms. Integration of hyperpolarisation would enable quantitative studies of metabolism in such volume limited systems by high-resolution NMR spectroscopy. We demonstrate, for the first time, the integrated generation and detection of a hyperpolarised metabolite on a microfluidic chip. The metabolite 1-$^{13}$C-fumarate is produced in a nuclear hyperpolarised form by (i) introducing para-enriched hydrogen into the solution by diffusion through a polymer membrane, (ii) reaction with a substrate in the presence of a ruthenium-based catalyst, and (iii) conversion of the singlet-polarised reaction product into a magnetised form by the application of a radiofrequency pulse sequence, all on the same microfluidic chip. The microfluidic device delivers a continuous flow of hyperpolarised material at the 2.5 $μ\text{L}/\text{min}$ scale, with a polarisation level of 4%. We demonstrate two methods for mitigating singlet-triplet mixing effects which otherwise reduce the achieved polarisation level.
△ Less
Submitted 25 January, 2022; v1 submitted 12 November, 2021;
originally announced November 2021.