Microwave Technologies in Experiments for Detection of Dark Matter Axions
Authors:
Jose R. Navarro-Madrid,
Jose María García-Barceló,
Alejandro Díaz-Morcillo
Abstract:
This article reviews different microwave technologies used in dark matter axion detection experiments with resonant cavities. The general concepts of the experiment are presented and ways to optimize the design parameters of microwave resonators are discussed. Additionally, different frequency tuning systems are described. Finally, research lines where microwave engineering can contribute to this…
▽ More
This article reviews different microwave technologies used in dark matter axion detection experiments with resonant cavities. The general concepts of the experiment are presented and ways to optimize the design parameters of microwave resonators are discussed. Additionally, different frequency tuning systems are described. Finally, research lines where microwave engineering can contribute to this kind of axion detection are presented.
△ Less
Submitted 30 April, 2024; v1 submitted 24 April, 2024;
originally announced April 2024.
-
RADES axion search results with a High-Temperature Superconducting cavity in an 11.7 T magnet
Authors:
S. Ahyoune,
A. Álvarez Melcón,
S. Arguedas Cuendis,
S. Calatroni,
C. Cogollos,
A. Díaz-Morcillo,
B. Döbrich,
J. D. Gallego,
J. M. García-Barceló,
B. Gimeno,
J. Golm,
X. Granados,
J. Gutierrez,
L. Herwig,
I. G. Irastorza,
N. Lamas,
A. Lozano-Guerrero,
W. L. Millar,
C. Malbrunot,
J. Miralda-Escudé,
P. Navarro,
J. R. Navarro-Madrid,
T. Puig,
M. Siodlaczek,
G. T. Telles
, et al. (1 additional authors not shown)
Abstract:
We describe the results of a haloscope axion search performed with an 11.7 T dipole magnet at CERN. The search used a custom-made radio-frequency cavity coated with high-temperature superconducting tape. A set of 27 h of data at a resonant frequency of around 8.84 GHz was analysed. In the range of axion mass 36.5676 $μ$eV to 36.5699 $μ$eV, corresponding to a width of 554 kHz, no signal excess hint…
▽ More
We describe the results of a haloscope axion search performed with an 11.7 T dipole magnet at CERN. The search used a custom-made radio-frequency cavity coated with high-temperature superconducting tape. A set of 27 h of data at a resonant frequency of around 8.84 GHz was analysed. In the range of axion mass 36.5676 $μ$eV to 36.5699 $μ$eV, corresponding to a width of 554 kHz, no signal excess hinting at an axion-like particle was found. Correspondingly, in this mass range, a limit on the axion to photon coupling-strength was set in the range between g$_{aγ}\gtrsim$ 6.2e-13 GeV$^{-1}$ and g$_{aγ}\gtrsim$ 1.54e-13 GeV$^{-1}$ with a 95% confidence level.
△ Less
Submitted 12 March, 2024;
originally announced March 2024.
-
Study of a cubic cavity resonator for gravitational waves detection in the microwave frequency range
Authors:
Pablo Navarro,
Benito Gimeno,
Juan Monzó-Cabrera,
Alejandro Díaz-Morcillo,
Diego Blas
Abstract:
The direct detection of gravitational waves (GWs) of frequencies above MHz has recently received considerable attention. In this work we present a precise study of the reach of a cubic cavity resonator to GWs in the microwave range, using for the first time tools allowing to perform realistic simulations. Concretely, the BI-RME 3D method, which allows us to obtain not only the detected power but a…
▽ More
The direct detection of gravitational waves (GWs) of frequencies above MHz has recently received considerable attention. In this work we present a precise study of the reach of a cubic cavity resonator to GWs in the microwave range, using for the first time tools allowing to perform realistic simulations. Concretely, the BI-RME 3D method, which allows us to obtain not only the detected power but also the detected voltage (magnitude and phase), is used here. After analyzing three cubic cavities for different frequencies and working simultaneously with three different degenerate modes at each cavity, we conclude that the sensitivity of the experiment is strongly dependent on the polarization and incidence angle of the GW. The presented experiment can reach sensitivities up to $ 1 \cdot 10^{-19}$ at 100\, MHz, $ 2 \cdot 10^{-20}$ at 1\, GHz, and $ 6 \cdot 10^{-19}$ at 10\, GHz for optimal angles and polarizations, and where in all cases we assumed an integration time of $Δt = 1$ ms. These results provide a strong case for further develo** the use of cavities to detect GWs. Moreover, the possibility of analyzing the detected voltage (magnitude and phase) opens a new interferometric detection scheme based on the combination of the detected signals from multiple cavities.
△ Less
Submitted 17 June, 2024; v1 submitted 4 December, 2023;
originally announced December 2023.
-
Enhancing resonant circular-section haloscopes for dark matter axion detection: approaches and limitations in volume expansion
Authors:
J. M. García-Barceló,
A. Díaz-Morcillo,
B. Gimeno
Abstract:
Haloscopes, microwave resonant cavities utilized in detecting dark matter axions within powerful static magnetic fields, are pivotal in modern astrophysical research. This paper delves into the realm of cylindrical geometries, investigating techniques to augment volume and enhance compatibility with dipole or solenoid magnets. The study explores volume constraints in two categories of haloscope de…
▽ More
Haloscopes, microwave resonant cavities utilized in detecting dark matter axions within powerful static magnetic fields, are pivotal in modern astrophysical research. This paper delves into the realm of cylindrical geometries, investigating techniques to augment volume and enhance compatibility with dipole or solenoid magnets. The study explores volume constraints in two categories of haloscope designs: those reliant on single cavities and those employing multicavities. In both categories, strategies to increase the expanse of elongated structures are elucidated. For multicavities, the optimization of space within magnets is explored through 1D configurations. Three subcavity stacking approaches are investigated, while the foray into 2D and 3D geometries lays the groundwork for future topological developments. The results underscore the efficacy of these methods, revealing substantial room for progress in cylindrical haloscope design. Notably, an elongated single cavity design attains a three-order magnitude increase in volume compared to a WC-109 standard waveguide-based single cavity. Diverse prototypes featuring single cavities, 1D, 2D, and 3D multicavities highlight the feasibility of leveraging these geometries to magnify the volume of tangible haloscope implementations.
△ Less
Submitted 25 October, 2023; v1 submitted 22 September, 2023;
originally announced September 2023.
-
A proposal for a low-frequency axion search in the 1-2 $μ$eV range and below with the BabyIAXO magnet
Authors:
S. Ahyoune,
A. Álvarez Melcón,
S. Arguedas Cuendis,
S. Calatroni,
C. Cogollos,
J. Devlin,
A. Díaz-Morcillo,
D. Díez-Ibáñez,
B. Döbrich,
J. Galindo,
J. D. Gallego,
J. M. García-Barceló,
B. Gimeno,
J. Golm,
Y. Gu,
L. Herwig,
I. G. Irastorza,
A. J. Lozano-Guerrero,
C. Malbrunot,
J. Miralda-Escudé,
J. Monzó-Cabrera,
P. Navarro,
J. R. Navarro-Madrid,
J. Redondo,
J. Reina-Valero
, et al. (5 additional authors not shown)
Abstract:
In the near future BabyIAXO will be the most powerful axion helioscope, relying on a custom-made magnet of two bores of 70 cm diameter and 10 m long, with a total available magnetic volume of more than 7 m$^3$. In this document, we propose and describe the implementation of low-frequency axion haloscope setups suitable for operation inside the BabyIAXO magnet. The RADES proposal has a potential se…
▽ More
In the near future BabyIAXO will be the most powerful axion helioscope, relying on a custom-made magnet of two bores of 70 cm diameter and 10 m long, with a total available magnetic volume of more than 7 m$^3$. In this document, we propose and describe the implementation of low-frequency axion haloscope setups suitable for operation inside the BabyIAXO magnet. The RADES proposal has a potential sensitivity to the axion-photon coupling $g_{aγ}$ down to values corresponding to the KSVZ model, in the (currently unexplored) mass range between 1 and 2$~μ$eV, after a total effective exposure of 440 days. This mass range is covered by the use of four differently dimensioned 5-meter-long cavities, equipped with a tuning mechanism based on inner turning plates. A setup like the one proposed would also allow an exploration of the same mass range for hidden photons coupled to photons. An additional complementary apparatus is proposed using LC circuits and exploring the low energy range ($\sim10^{-4}-10^{-1}~μ$eV). The setup includes a cryostat and cooling system to cool down the BabyIAXO bore down to about 5 K, as well as appropriate low-noise signal amplification and detection chain.
△ Less
Submitted 22 November, 2023; v1 submitted 29 June, 2023;
originally announced June 2023.
-
Methods and restrictions to increase the volume of resonant rectangular-section haloscopes for detecting dark matter axions
Authors:
J. M. García-Barceló,
A. Álvarez Melcón,
A. Díaz-Morcillo,
B. Gimeno,
A. J. Lozano-Guerrero,
J. Monzo-Cabrera,
J. R. Navarro-Madrid,
P. Navarro
Abstract:
Haloscopes are resonant cavities that serve as detectors of dark matter axions when they are immersed in a strong static magnetic field. In order to increase the volume and improve its introduction within dipole or solenoid magnets for axion searches, various haloscope design techniques for rectangular geometries are discussed in this study. The volume limits of two types of haloscopes are explore…
▽ More
Haloscopes are resonant cavities that serve as detectors of dark matter axions when they are immersed in a strong static magnetic field. In order to increase the volume and improve its introduction within dipole or solenoid magnets for axion searches, various haloscope design techniques for rectangular geometries are discussed in this study. The volume limits of two types of haloscopes are explored: based on single cavities and based on multicavities. For both cases, possibilities for increasing the volume in long and/or tall structures are presented. For multicavities, 1D geometries are explored to optimize the space in the magnets. Also, 2D and 3D geometries are introduced as a first step for laying the foundations for the development of these kind of topologies. The results prove the usefulness of the developed methods, evidencing the ample room of improvement in rectangular haloscope designs nowadays. A factor of three orders of magnitude improvement in volume compared with a single cavity based on WR-90 standard waveguide is obtained with the design of a long and tall single cavity. Similar procedures have been applied for long and tall multicavities. Experimental measurements are shown for prototypes based on tall multicavities and 2D structures, demonstrating the feasibility of using these types of geometries to increase the volume in real haloscopes.
△ Less
Submitted 24 February, 2023; v1 submitted 21 February, 2023;
originally announced February 2023.
-
The Canfranc Axion Detection Experiment (CADEx): Search for axions at 90 GHz with Kinetic Inductance Detectors
Authors:
Beatriz Aja,
Sergio Arguedas Cuendis,
Ivan Arregui,
Eduardo Artal,
R. Belén Barreiro,
Francisco J. Casas,
Maria C. de Ory,
Alejandro Díaz-Morcillo,
Luisa de la Fuente,
Juan Daniel Gallego,
José María García-Barceló,
Benito Gimeno,
Alicia Gomez,
Daniel Granados,
Bradley J. Kavanagh,
Miguel A. G. Laso,
Txema Lopetegi,
Antonio José Lozano-Guerrero,
Maria T. Magaz,
Jesús Martín-Pintado,
Enrique Martínez-González,
Jordi Miralda-Escudé,
Juan Monzó-Cabrera,
Jose R. Navarro-Madrid,
Ana B. Nuñez Chico
, et al. (11 additional authors not shown)
Abstract:
We propose a novel experiment, the Canfranc Axion Detection Experiment (CADEx), to probe dark matter axions with masses in the range 330-460 $μ$eV, within the W-band (80-110 GHz), an unexplored parameter space in the well-motivated dark matter window of Quantum ChromoDynamics (QCD) axions. The experimental design consists of a microwave resonant cavity haloscope in a high static magnetic field cou…
▽ More
We propose a novel experiment, the Canfranc Axion Detection Experiment (CADEx), to probe dark matter axions with masses in the range 330-460 $μ$eV, within the W-band (80-110 GHz), an unexplored parameter space in the well-motivated dark matter window of Quantum ChromoDynamics (QCD) axions. The experimental design consists of a microwave resonant cavity haloscope in a high static magnetic field coupled to a highly sensitive detecting system based on Kinetic Inductance Detectors via optimized quasi-optics (horns and mirrors). The experiment is in preparation and will be installed in the dilution refrigerator of the Canfranc Underground Laboratory. Sensitivity forecasts for axion detection with CADEx, together with the potential of the experiment to search for dark photons, are presented.
△ Less
Submitted 6 June, 2022;
originally announced June 2022.
-
On the use of ferroelectric material in the detection of dark matter axions
Authors:
J. M. García Barceló,
A. Álvarez Melcón,
S. Arguedas Cuendis,
A. Díaz-Morcillo,
B. Gimeno,
A. Kanareykin,
A. J. Lozano-Guerrero,
P. Navarro,
W. Wuensch
Abstract:
Tuning is an essential requirement for the search of dark matter axions employing haloscopes since its mass is not known yet to the scientific community. At the present day, most haloscope tuning systems are based on mechanical devices which can lead to failures due to the complexity of the environment in which they are used. However, the electronic tuning making use of ferroelectric materials can…
▽ More
Tuning is an essential requirement for the search of dark matter axions employing haloscopes since its mass is not known yet to the scientific community. At the present day, most haloscope tuning systems are based on mechanical devices which can lead to failures due to the complexity of the environment in which they are used. However, the electronic tuning making use of ferroelectric materials can provide a path that is less vulnerable to mechanical failures and thus complements and expands current tuning systems. In this work, we present and design a novel concept for using the ferroelectric Potassium Tantalate ($KTaO_3$ or KTO) material as a tuning element in haloscopes based on coupled microwave cavities. In this line, the structures used in the Relic Axion Detector Exploratory Setup (RADES) group are based on several cavities that are connected by metallic irises, which act as interresonator coupling elements. In this article, we also show how to use these $KTaO_3$ films as interresonator couplings between cavities, instead of inductive or capacitive metallic windows used in the past. These two concepts represent a crucial upgrade over the current systems employed in the dark matter axions community, achieving a tuning range of $2.23 \, \%$ which represents a major improvement as compared to previous works ($<0.1 \, \%$) for the same class of tuning systems. The theoretical and simulated results shown in this work demonstrate the interest of the novel concepts proposed for the incorporation of this kind of ferroelectric media in multicavity resonant haloscopes in the search for dark matter axions.
△ Less
Submitted 7 December, 2022; v1 submitted 25 April, 2022;
originally announced April 2022.
-
Axion Dark Matter
Authors:
C. B. Adams,
N. Aggarwal,
A. Agrawal,
R. Balafendiev,
C. Bartram,
M. Baryakhtar,
H. Bekker,
P. Belov,
K. K. Berggren,
A. Berlin,
C. Boutan,
D. Bowring,
D. Budker,
A. Caldwell,
P. Carenza,
G. Carosi,
R. Cervantes,
S. S. Chakrabarty,
S. Chaudhuri,
T. Y. Chen,
S. Cheong,
A. Chou,
R. T. Co,
J. Conrad,
D. Croon
, et al. (130 additional authors not shown)
Abstract:
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synerg…
▽ More
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.
△ Less
Submitted 29 March, 2023; v1 submitted 28 March, 2022;
originally announced March 2022.
-
New Horizons: Scalar and Vector Ultralight Dark Matter
Authors:
D. Antypas,
A. Banerjee,
C. Bartram,
M. Baryakhtar,
J. Betz,
J. J. Bollinger,
C. Boutan,
D. Bowring,
D. Budker,
D. Carney,
G. Carosi,
S. Chaudhuri,
S. Cheong,
A. Chou,
M. D. Chowdhury,
R. T. Co,
J. R. Crespo López-Urrutia,
M. Demarteau,
N. DePorzio,
A. V. Derbin,
T. Deshpande,
M. D. Chowdhury,
L. Di Luzio,
A. Diaz-Morcillo,
J. M. Doyle
, et al. (104 additional authors not shown)
Abstract:
The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical,…
▽ More
The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical, largely coherent field. This white paper focuses on searches for wavelike scalar and vector dark matter candidates.
△ Less
Submitted 28 March, 2022;
originally announced March 2022.
-
Design of new resonant haloscopes in the search for the darkmatter axion: a review of the first steps in the RADES collaboration
Authors:
A. Díaz-Morcillo,
J. M. García Barceló,
A. J. Lozano-Guerrero,
P. Navarro,
B. Gimeno,
S. Arguedas Cuendis,
A. Álvarez Melcón,
C. Cogollos,
S. Calatroni,
B. Döbrich,
J. D. Gallego,
J. Golm,
I. G. Irastorza,
C. Malbrunot,
Jordi Miralda-Escudé,
C. Peña Garay,
J. Redondo,
W. Wuensch
Abstract:
Within the increasing interest in the dark matter axion detection through haloscopes, in which different international groups are currently involved, the RADES group was established in 2016 with the goal of develo** very sensitive detection systems to be operated in dipole magnets. This review deals with the work developed by this collaboration during its first five years, from the first designs…
▽ More
Within the increasing interest in the dark matter axion detection through haloscopes, in which different international groups are currently involved, the RADES group was established in 2016 with the goal of develo** very sensitive detection systems to be operated in dipole magnets. This review deals with the work developed by this collaboration during its first five years, from the first designs, based on the multi-cavity concept, aiming to increase the haloscope volume and, so, to improve its sensitivity, their evolution, the data acquisition design, and, finally, the first experimental run. Moreover, the envisaged work within RADES, for both dipole and solenoid magnets, in the short and medium term is also presented.
△ Less
Submitted 22 January, 2022; v1 submitted 29 November, 2021;
originally announced November 2021.
-
The 3 cavity prototypes of RADES, an axion detector using microwave filters at CAST
Authors:
S. Arguedas Cuendis,
A. Álvarez Melcón,
C. Cogollos,
A. Díaz-Morcillo,
B. Döbrich,
J. D. Gallego,
B. Gimeno,
I. G. Irastorza,
A. J. Lozano-Guerrero,
C. Malbrunot,
P. Navarro,
C. Peña Garay,
J. Redondo,
T. Vafeiadis,
W. Wuensch
Abstract:
The Relic Axion Detector Experimental Setup (RADES) is an axion search project that uses a microwave filter as resonator for Dark Matter conversion. The main focus of this publication is the description of the 3 different cavity prototypes of RADES. The result of the first tests of one of the prototypes is also presented. The filters consist of 5 or 6 stainless steel sub-cavities joined by rectang…
▽ More
The Relic Axion Detector Experimental Setup (RADES) is an axion search project that uses a microwave filter as resonator for Dark Matter conversion. The main focus of this publication is the description of the 3 different cavity prototypes of RADES. The result of the first tests of one of the prototypes is also presented. The filters consist of 5 or 6 stainless steel sub-cavities joined by rectangular irises. The size of the sub-cavities determines the working frequency, the amount of sub-cavities determine the working volume. The first cavity prototype was built in 2017 to work at a frequency of $\sim$ 8.4 GHz and it was placed at the 9 T CAST dipole magnet at CERN. Two more prototypes were designed and built in 2018. The aim of the new designs is to find and test the best cavity geometry in order to scale up in volume and to introduce an effective tuning mechanism. Our results demonstrate the promising potential of this type of filter to reach QCD axion sensitivity at X-Band frequencies.
△ Less
Submitted 11 March, 2019;
originally announced March 2019.