-
Injected power fluctuations for a non-equilibrium electronic disspative system in space
Authors:
José A. Ogalde,
Claudio B. Falcón,
Marcos A. Díaz
Abstract:
In this article we present an experimental study of the statistical properties for the injected power fluctuations of a dissipative system as a function of external environmental conditions. A Brownian motion analog is implemented using a series resistor and capacitor circuit with an Orstein-Ulhenbeck forcing. This system is tested in a controlled thermal bath at the laboratory, setting the bath t…
▽ More
In this article we present an experimental study of the statistical properties for the injected power fluctuations of a dissipative system as a function of external environmental conditions. A Brownian motion analog is implemented using a series resistor and capacitor circuit with an Orstein-Ulhenbeck forcing. This system is tested in a controlled thermal bath at the laboratory, setting the bath temperature and different bath atmospheric pressures. The non-equilibrium system shows a higher correlation factor between the external forcing and the system response with increasing bath atmospheric pressure at constant temperature. These results were put to test in an uncontrolled bath such as space, by using a satellite orbiting at 505 km of altitude. A reduced version of the previous experiment was built to fit the satellite capabilities and was successfully integrated in the inner side of the satellite and then run in several locations of its orbit.
△ Less
Submitted 14 September, 2021;
originally announced September 2021.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
JUNO Conceptual Design Report
Authors:
T. Adam,
F. An,
G. An,
Q. An,
N. Anfimov,
V. Antonelli,
G. Baccolo,
M. Baldoncini,
E. Baussan,
M. Bellato,
L. Bezrukov,
D. Bick,
S. Blyth,
S. Boarin,
A. Brigatti,
T. Brugière,
R. Brugnera,
M. Buizza Avanzini,
J. Busto,
A. Cabrera,
H. Cai,
X. Cai,
A. Cammi,
D. Cao,
G. Cao
, et al. (372 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory (JUNO) is proposed to determine the neutrino mass hierarchy using an underground liquid scintillator detector. It is located 53 km away from both Yangjiang and Taishan Nuclear Power Plants in Guangdong, China. The experimental hall, spanning more than 50 meters, is under a granite mountain of over 700 m overburden. Within six years of running, the dete…
▽ More
The Jiangmen Underground Neutrino Observatory (JUNO) is proposed to determine the neutrino mass hierarchy using an underground liquid scintillator detector. It is located 53 km away from both Yangjiang and Taishan Nuclear Power Plants in Guangdong, China. The experimental hall, spanning more than 50 meters, is under a granite mountain of over 700 m overburden. Within six years of running, the detection of reactor antineutrinos can resolve the neutrino mass hierarchy at a confidence level of 3-4$σ$, and determine neutrino oscillation parameters $\sin^2θ_{12}$, $Δm^2_{21}$, and $|Δm^2_{ee}|$ to an accuracy of better than 1%. The JUNO detector can be also used to study terrestrial and extra-terrestrial neutrinos and new physics beyond the Standard Model. The central detector contains 20,000 tons liquid scintillator with an acrylic sphere of 35 m in diameter. $\sim$17,000 508-mm diameter PMTs with high quantum efficiency provide $\sim$75% optical coverage. The current choice of the liquid scintillator is: linear alkyl benzene (LAB) as the solvent, plus PPO as the scintillation fluor and a wavelength-shifter (Bis-MSB). The number of detected photoelectrons per MeV is larger than 1,100 and the energy resolution is expected to be 3% at 1 MeV. The calibration system is designed to deploy multiple sources to cover the entire energy range of reactor antineutrinos, and to achieve a full-volume position coverage inside the detector. The veto system is used for muon detection, muon induced background study and reduction. It consists of a Water Cherenkov detector and a Top Tracker system. The readout system, the detector control system and the offline system insure efficient and stable data acquisition and processing.
△ Less
Submitted 28 September, 2015; v1 submitted 28 August, 2015;
originally announced August 2015.
-
Position resolution and efficiency measurements with large scale Thin Gap Chambers for the super LHC
Authors:
Nir Amram,
Gideon Bella,
Yan Benhammou,
Marco A. Diaz,
Ehud Duchovni,
Erez Etzion,
Alon Hershenhorn,
Amit Klier,
Nachman Lupu,
Giora Mikenberg,
Dmitry Milstein,
Yonathan Munwes,
Osamu Sasaki,
Meir Shoa,
Vladimir Smakhtin,
Ulrich Volkmann
Abstract:
New developments in Thin Gap Chambers (TGC) detectors to provide fast trigger and high precision muon tracking under sLHC conditions are presented. The modified detectors are shown to stand a high total irradiation dose equivalent to 6 Coulomb/cm of wire, without showing any deterioration in their performance. Two large (1.2 x 0.8 m^2) prototypes containing four gaps, each gap providing pad, strip…
▽ More
New developments in Thin Gap Chambers (TGC) detectors to provide fast trigger and high precision muon tracking under sLHC conditions are presented. The modified detectors are shown to stand a high total irradiation dose equivalent to 6 Coulomb/cm of wire, without showing any deterioration in their performance. Two large (1.2 x 0.8 m^2) prototypes containing four gaps, each gap providing pad, strips and wires readout, with a total thickness of 50 mm, have been constructed. Their local spatial resolution has been measured in a 100 GeV/c muon test beam at CERN. At perpendicular incidence angle, single gap position resolution better than 60 microns has been obtained. For incidence angle of 20 degrees resolution of less than 100 micron was achieved. TGC prototypes were also tested under a flux of 10^5 Hz/cm^2 of 5.5-6.5 MeV neutrons, showing a high efficiency for cosmic muons detection.
△ Less
Submitted 2 June, 2010; v1 submitted 1 June, 2010;
originally announced June 2010.