SLAC Microresonator RF (SMuRF) Electronics: A tone-tracking readout system for superconducting microwave resonator arrays
Authors:
Cyndia Yu,
Zeeshan Ahmed,
Josef C. Frisch,
Shawn W. Henderson,
Max Silva-Feaver,
Kam Arnold,
David Brown,
Jake Connors,
Ari J. Cukierman,
J. Mitch D'Ewart,
Bradley J. Dober,
John E. Dusatko,
Gunther Haller,
Ryan Herbst,
Gene C. Hilton,
Johannes Hubmayr,
Kent D. Irwin,
Chao-Lin Kuo,
John A. B. Mates,
Larry Ruckman,
Joel Ullom,
Leila Vale,
Daniel D. Van Winkle,
Jesus Vasquez,
Edward Young
Abstract:
We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems such as microwave SQUID multiplexers ($μ$mux) or microwave kinetic inductance detectors (MKIDs). Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arr…
▽ More
We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems such as microwave SQUID multiplexers ($μ$mux) or microwave kinetic inductance detectors (MKIDs). Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4-8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here we present a description of the hardware, firmware, and software systems of the SMuRF electronics, comparing achieved performance with science-driven design requirements. We focus in particular on the case of large channel count, low bandwidth applications, but the system has been easily reconfigured for high bandwidth applications. The system described here has been successfully deployed in lab settings and field sites around the world and is baselined for use on upcoming large-scale observatories.
△ Less
Submitted 22 August, 2022;
originally announced August 2022.
-
A simulation suite for readout with SMuRF tone-tracking electronics
Authors:
Cyndia Yu,
Zeeshan Ahmed,
J. Mitch D'Ewart,
Josef C. Frisch,
Shawn W. Henderson,
Max Silva-Feaver
Abstract:
We present the details of a simulation suite for modeling the effects of readout with SLAC Microresonator RF (SMuRF) electronics. The SMuRF electronics are a warm readout and control system for use with superconducting microwave resonator-based detector systems. The system has been used with the BICEP/Keck program and will be used on the upcoming Simons Observatory and BICEP Array experiments. Thi…
▽ More
We present the details of a simulation suite for modeling the effects of readout with SLAC Microresonator RF (SMuRF) electronics. The SMuRF electronics are a warm readout and control system for use with superconducting microwave resonator-based detector systems. The system has been used with the BICEP/Keck program and will be used on the upcoming Simons Observatory and BICEP Array experiments. This simulation suite is a software implementation of the main SMuRF algorithms for offline analysis, modeling, and study. The firmware-implemented algorithms for calibration, resonator frequency estimation, and tone tracking present sources of potential bias or errors if not modeled properly. The simulator takes as input true detector signal, realistic resonator properties, and SMuRF-related user-controlled readout settings. It returns the final flux ramp-demodulated output of a detector timestream as would be passed to the experiment data acquisition system, enabling the analysis of the impact of readout-related parameters on the final science data. It is publicly available in Python with accompanying Jupyter notebooks for user tutorials.
△ Less
Submitted 3 August, 2022;
originally announced August 2022.
-
Bandwidth and Aliasing in the Microwave SQUID Multiplexer
Authors:
Cyndia Yu,
Zeeshan Ahmed,
Jake A. Connors,
J. Mitch D'Ewart,
Bradley Dober,
Josef C. Frisch,
Shawn W. Henderson,
Gene C. Hilton,
Johannes Hubmayr,
Stephen E. Kuenstner,
J. A. Ben Mates,
Maximiliano Silva-Feaver,
Joel N. Ullom,
Leila R. Vale,
Dan Van Winkle,
Edward Young
Abstract:
The microwave SQUID multiplexer (umux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial availability of microwave components and warm electronics readout systems make it an attractive candidate for systems requiring large cryogenic detector counts.…
▽ More
The microwave SQUID multiplexer (umux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial availability of microwave components and warm electronics readout systems make it an attractive candidate for systems requiring large cryogenic detector counts. Since the multiplexer is considered for both bolometric and calorimetric applications across several orders of magnitude of signal frequencies, understanding the bandwidth of the device and its interaction with readout electronics is key to appropriately designing and engineering systems. Here we discuss several important factors contributing to the bandwidth properties of umux systems, including the intrinsic device bandwidth, interactions with warm electronics readout systems, and aliasing. We present simulations and measurements of umux devices coupled with SLAC Microresonator RF (SMuRF) tone-tracking electronics and discuss several implications for future experimental design.
△ Less
Submitted 17 June, 2022;
originally announced June 2022.