-
Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation
Authors:
Gabriele Giacomini,
Wei Chen,
Gabriele D'Amen,
Enrico Rossi,
Alessandro Tricoli
Abstract:
Low-Gain Avalanche Diodes are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the Low-Gain Avalanche Diode paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance…
▽ More
Low-Gain Avalanche Diodes are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the Low-Gain Avalanche Diode paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While Low-Gain Avalanche Diodes are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of Low-Gain Avalanche Diodes: two devices with different geometries and do** profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process.
Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to breakdown voltage. The signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.
△ Less
Submitted 6 February, 2024;
originally announced February 2024.
-
Signal formation and sharing in AC-LGADs using the ALTIROC 0 front-end chip
Authors:
G. D'Amen,
W. Chen,
C. De La Taille,
G. Giacomini,
D. Marchand,
M. Morenas,
C. Munoz Camacho,
E. Rossi,
N. Seguin-Moreau,
L. Serin,
A. Tricoli,
P. -K. Wang
Abstract:
The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. However, finding a technology capable of fulfilling such aspiration proved to be an arduous task. Among other silicon-based candidates,…
▽ More
The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. However, finding a technology capable of fulfilling such aspiration proved to be an arduous task. Among other silicon-based candidates, the Low-Gain Avalanche Diode (LGAD) has already shown excellent timing performances but proved to be unsuitable for fine pixelization. Therefore, the AC-coupled LGAD (AC-LGAD) approach was introduced to provide high resolution in both time and space, making it a promising candidate for future 4D detectors. However, appropriate readout electronics must be developed to match the sensor's fast-time and fine-pitch capabilities. This is currently a major technological challenge. In this paper, we test AC-LGAD prototypes read out by the fast-time ASIC ALTIROC 0, originally developed for the readout of DC-coupled LGADs for the ATLAS experiment at the HL-LHC. Signal generated by either betas from a $^{90}$Sr source or a focused infra-red laser were analyzed. This paper details the first successful readout of an AC-LGAD sensor using a readout chip. This result will pave the way for the design and construction of a new generation of AC-LGAD-based 4D detectors.
△ Less
Submitted 15 September, 2022;
originally announced September 2022.
-
Solid State Detectors and Tracking for Snowmass
Authors:
A. Affolder,
A. Apresyan,
S. Worm,
M. Albrow,
D. Ally,
D. Ambrose,
E. Anderssen,
N. Apadula,
P. Asenov,
W. Armstrong,
M. Artuso,
A. Barbier,
P. Barletta,
L. Bauerdick,
D. Berry,
M. Bomben,
M. Boscardin,
J. Brau,
W. Brooks,
M. Breidenbach,
J. Buckley,
V. Cairo,
R. Caputo,
L. Carpenter,
M. Centis-Vignali
, et al. (110 additional authors not shown)
Abstract:
Tracking detectors are of vital importance for collider-based high energy physics (HEP) experiments. The primary purpose of tracking detectors is the precise reconstruction of charged particle trajectories and the reconstruction of secondary vertices. The performance requirements from the community posed by the future collider experiments require an evolution of tracking systems, necessitating the…
▽ More
Tracking detectors are of vital importance for collider-based high energy physics (HEP) experiments. The primary purpose of tracking detectors is the precise reconstruction of charged particle trajectories and the reconstruction of secondary vertices. The performance requirements from the community posed by the future collider experiments require an evolution of tracking systems, necessitating the development of new techniques, materials and technologies in order to fully exploit their physics potential. In this article we summarize the discussions and conclusions of the 2022 Snowmass Instrumentation Frontier subgroup on Solid State and Tracking Detectors (Snowmass IF03).
△ Less
Submitted 19 October, 2022; v1 submitted 8 September, 2022;
originally announced September 2022.
-
Characterization of BNL and HPK AC-LGAD sensors with a 120 GeV proton beam
Authors:
Ryan Heller,
Christopher Madrid,
Artur Apresyan,
William K. Brooks,
Wei Chen,
Gabriele D'Amen,
Gabriele Giacomini,
Ikumi Goya,
Kazuhiko Hara,
Sayuka Kita,
Sergey Los,
Adam Molnar,
Koji Nakamura,
Cristián Peña,
Claudio San Martín,
Alessandro Tricoli,
Tatsuki Ueda,
Si Xie
Abstract:
We present measurements of AC-LGADs performed at the Fermilab's test beam facility using 120 GeV protons. We studied the performance of various strip and pad AC-LGAD sensors that were produced by BNL and HPK. The measurements are performed with our upgraded test beam setup that utilizes a high precision telescope tracker, and a simultaneous readout of up to 7 channels per sensor, which allows deta…
▽ More
We present measurements of AC-LGADs performed at the Fermilab's test beam facility using 120 GeV protons. We studied the performance of various strip and pad AC-LGAD sensors that were produced by BNL and HPK. The measurements are performed with our upgraded test beam setup that utilizes a high precision telescope tracker, and a simultaneous readout of up to 7 channels per sensor, which allows detailed studies of signal sharing characteristics. These measurements allow us to assess the differences in designs between different manufacturers, and optimize them based on experimental performance. We then study several reconstruction algorithms to optimize position and time resolutions that utilize the signal sharing properties of each sensor. We present a world's first demonstration of silicon sensors in a test beam that simultaneously achieve better than 6-10 micron position and 30 ps time resolution. This represents a substantial improvement to the spatial resolution than would be obtained with binary readout of sensors with similar pitch.
△ Less
Submitted 29 March, 2022; v1 submitted 19 January, 2022;
originally announced January 2022.
-
Novel imaging technique for $α$-particles using a fast optical camera
Authors:
Gabriele D'Amen,
Michael Keach,
Andrei Nomerotski,
Peter Svihra,
Alessandro Tricoli
Abstract:
A new imaging technique for $α$-particles using a fast optical camera focused on a thin scintillator is presented. As $α$-particles interact in a thin layer of LYSO fast scintillator, they produce a localized flash of light. The light is collected with a lens to an intensified optical camera, Tpx3Cam, with single photon sensitivity and excellent spatial & temporal resolutions. The interactions of…
▽ More
A new imaging technique for $α$-particles using a fast optical camera focused on a thin scintillator is presented. As $α$-particles interact in a thin layer of LYSO fast scintillator, they produce a localized flash of light. The light is collected with a lens to an intensified optical camera, Tpx3Cam, with single photon sensitivity and excellent spatial & temporal resolutions. The interactions of photons with the camera is reconstructed by means of a custom algorithm, capable of discriminating single photons using time and spatial information.
△ Less
Submitted 28 October, 2020;
originally announced October 2020.
-
Measurements of an AC-LGAD strip sensor with a 120 GeV proton beam
Authors:
Artur Apresyan,
Wei Chen,
Gabriele D'Amen,
Karri Folan Di Petrillo,
Gabriele Giacomini,
Ryan Heller,
Hakseong Lee,
Sergey Los,
Chang-Seong Moon,
Alessandro Tricoli
Abstract:
The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for several applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. In addition to high time resolution and thanks to the AC-coupling of the electrodes, LGAD silicon sensors can provide high reso…
▽ More
The development of detectors that provide high resolution in four dimensions has attracted wide-spread interest in the scientific community for several applications in high-energy physics, nuclear physics, medical imaging, mass spectroscopy as well as quantum information. In addition to high time resolution and thanks to the AC-coupling of the electrodes, LGAD silicon sensors can provide high resolution in the measurement of spatial coordinates of an incident minimum ionizing particle. Such AC-coupled LGADs, also known as AC-LGADs, are therefore considered as candidates for future detectors to provide 4-dimensional measurements in a single sensing device with 100$\%$ fill factor. This article presents the first characterization of an AC-LGAD sensor with a proton beam of 120 GeV momentum at Fermilab. The sensor consists of strips with 80 $μ$m width, fabricated at Brookhaven National Laboratory. The signal properties, efficiency, spatial, and time resolution are presented. The experimental results show that the time resolution of such an AC-LGAD is compatible to standard LGADs with similar gain, and that AC-LGADs can be segmented with fine pitches as standard strip or pixel detectors.
△ Less
Submitted 6 November, 2020; v1 submitted 2 June, 2020;
originally announced June 2020.
-
Beam test results of IHEP-NDL Low Gain Avalanche Detectors(LGAD)
Authors:
S. Xiao,
S. Alderweireldt,
S. Ali,
C. Allaire,
C. Agapopoulou,
N. Atanov,
M. K. Ayoub,
G. Barone,
D. Benchekroun,
A. Buzatu,
D. Caforio,
L. Castillo García,
Y. Chan,
H. Chen,
V. Cindro,
L. Ciucu,
J. Barreiro Guimarães da Costa,
H. Cui,
F. Davó Miralles,
Y. Davydov,
G. d'Amen,
C. de la Taille,
R. Kiuchi,
Y. Fan,
A. Falou
, et al. (75 additional authors not shown)
Abstract:
To meet the timing resolution requirement of up-coming High Luminosity LHC (HL-LHC), a new detector based on the Low-Gain Avalanche Detector(LGAD), High-Granularity Timing Detector (HGTD), is under intensive research in ATLAS. Two types of IHEP-NDL LGADs(BV60 and BV170) for this update is being developed by Institute of High Energy Physics (IHEP) of Chinese Academic of Sciences (CAS) cooperated wi…
▽ More
To meet the timing resolution requirement of up-coming High Luminosity LHC (HL-LHC), a new detector based on the Low-Gain Avalanche Detector(LGAD), High-Granularity Timing Detector (HGTD), is under intensive research in ATLAS. Two types of IHEP-NDL LGADs(BV60 and BV170) for this update is being developed by Institute of High Energy Physics (IHEP) of Chinese Academic of Sciences (CAS) cooperated with Novel Device Laboratory (NDL) of Bei**g Normal University and they are now under detailed study. These detectors are tested with $5GeV$ electron beam at DESY. A SiPM detector is chosen as a reference detector to get the timing resolution of LGADs. The fluctuation of time difference between LGAD and SiPM is extracted by fitting with a Gaussian function. Constant fraction discriminator (CFD) method is used to mitigate the effect of time walk. The timing resolution of $41 \pm 1 ps$ and $63 \pm 1 ps$ are obtained for BV60 and BV170 respectively.
△ Less
Submitted 14 May, 2020;
originally announced May 2020.
-
Radiation Campaign of HPK Prototype LGAD sensors for the High-Granularity Timing Detector (HGTD)
Authors:
X. Shi,
M. K. Ayoub,
J. Barreiro Guimarães da Costa,
H. Cui,
R. Kiuchi,
Y. Fan,
S. Han,
Y. Huang,
M. **g,
Z. Liang,
B. Liu,
J. Liu,
F. Lyu,
B. Qi,
K. Ran,
L. Shan,
L. Shi,
Y. Tan,
K. Wu,
S. Xiao,
T. Yang,
Y. Yang,
C. Yu,
M. Zhao,
X. Zhuang
, et al. (52 additional authors not shown)
Abstract:
We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~$μ$m were irradiated in steps of roughly 2$\times$ up to a fluence of $3\times10^{15}~\mathrm{n_{eq}cm^{-2}}$. As a function of the fluence, the co…
▽ More
We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~$μ$m were irradiated in steps of roughly 2$\times$ up to a fluence of $3\times10^{15}~\mathrm{n_{eq}cm^{-2}}$. As a function of the fluence, the collected charge and time resolution of the irradiated sensors will be reported for operation at $-30^{\circ}$.
△ Less
Submitted 28 April, 2020;
originally announced April 2020.
-
Layout and Performance of HPK Prototype LGAD Sensors for the High-Granularity Timing Detector
Authors:
X. Yang,
S. Alderweireldt,
N. Atanov,
M. K. Ayoub,
J. Barreiro Guimaraes da Costa,
L. Castillo Garcia,
H. Chen,
S. Christie,
V. Cindro,
H. Cui,
G. D'Amen,
Y. Davydov,
Y. Y. Fan,
Z. Galloway,
J. J. Ge,
C. Gee,
G. Giacomini,
E. L. Gkougkousis,
C. Grieco,
S. Grinstein,
J. Grosse-Knetter,
S. Guindon,
S. Han,
A. Howard,
Y. P. Huang
, et al. (54 additional authors not shown)
Abstract:
The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|η|<4.0$ with two end caps on each side and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising…
▽ More
The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|η|<4.0$ with two end caps on each side and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising edge, which improve significantly the signal-to-noise ratio. The required average timing resolution per track for a minimum-ionising particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1 MeV-neutron equivalent fluence up to $2.5 \times 10^{15} cm^{-2}$ before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-up at the HL-LHC. The layout and performance of the various versions of LGAD prototypes produced by Hamamatsu (HPK) have been studied by the ATLAS Collaboration. The breakdown voltages, depletion voltages, inter-pad gaps, collected charge as well as the time resolution have been measured and the production yield of large size sensors has been evaluated.
△ Less
Submitted 31 March, 2020;
originally announced March 2020.
-
Fabrication and performance of AC-coupled LGADs
Authors:
Gabriele Giacomini,
Wei Chen,
Gabriele D'Amen,
Alessandro Tricoli
Abstract:
Detectors that can simultaneously provide fine time and spatial resolution have attracted wide-spread interest for applications in several fields such as high-energy and nuclear physics as well as in low-energy electron detection, photon science, photonics and imaging. Low-Gain Avalanche Diodes (LGADs), being fabricated on thin silicon substrates and featuring a charge gain of up to 100, exhibit e…
▽ More
Detectors that can simultaneously provide fine time and spatial resolution have attracted wide-spread interest for applications in several fields such as high-energy and nuclear physics as well as in low-energy electron detection, photon science, photonics and imaging. Low-Gain Avalanche Diodes (LGADs), being fabricated on thin silicon substrates and featuring a charge gain of up to 100, exhibit excellent timing performance. Since pads much larger than the substrate thickness are necessary to achieve a spatially uniform multiplication, a fine pad pixelation is difficult. To overcome this limitation, the AC-coupled LGAD approach was introduced. In this type of device, metal electrodes are placed over an insulator at a fine pitch, and signals are capacitively induced on these electrodes. At Brookhaven National Laboratory, we have designed and fabricated prototypes of AC-coupled LGAD sensors. The performance of small test structures with different particle beams from radioactive sources are shown.
△ Less
Submitted 3 September, 2019; v1 submitted 27 June, 2019;
originally announced June 2019.
-
General purpose readout board π LUP: overview and results
Authors:
Nico Giangiacomi,
Giuseppe Gebbia,
Fabrizio Alfonsi,
Gabriele d'Amen,
Gabriele Balbi,
Davide Falchieri,
Alessandro Gabrielli,
Giuliano Pellegrini,
Riccardo Travaglini
Abstract:
This work gives an overview of the PCI-Express board $π$LUP, focusing on the motivation that led to its development, the technological choices adopted and its performance. The $π$LUP card was designed by INFN and University of Bologna as a readout interface candidate to be used after the Phase-II upgrade of the Pixel Detector of the ATLAS and CMS experiments at LHC. The same team in Bologna is als…
▽ More
This work gives an overview of the PCI-Express board $π$LUP, focusing on the motivation that led to its development, the technological choices adopted and its performance. The $π$LUP card was designed by INFN and University of Bologna as a readout interface candidate to be used after the Phase-II upgrade of the Pixel Detector of the ATLAS and CMS experiments at LHC. The same team in Bologna is also responsible for the design and commissioning of the ReadOut Driver (ROD) board - currently implemented in all the four layers of the ATLAS Pixel Detector (Insertable B-Layer, B-Layer, Layer-1 and Layer-2) - and acquired in the past years expertise on the ATLAS readout chain and the problematics arising in such experiments. Although the $π$LUP was designed to fulfill a specific task, it is highly versatile and might fit a wide variety of applications, some of which will be discussed in this work. Two 7$^{th}$-generation Xilinx FPGAs are mounted on the board: a Zynq-7 with an embedded dual core ARM Processor and a Kintex-7. The latter features sixteen 12.5$\,$Gbps transceivers, allowing the board to interface easily to any other electronic board, either electrically and/or optically, at the current bandwidth of the experiments for LHC. Many data-transmission protocols have been tested at different speeds, results will be discussed later in this work. Two batches of $π$LUP boards have been fabricated and tested, two boards in the first batch (version 1.0) and four boards in the second batch (version 1.1), encapsulating all the patches and improvements required by the first version.
△ Less
Submitted 22 June, 2018;
originally announced June 2018.
-
Production and Integration of the ATLAS Insertable B-Layer
Authors:
B. Abbott,
J. Albert,
F. Alberti,
M. Alex,
G. Alimonti,
S. Alkire,
P. Allport,
S. Altenheiner,
L. Ancu,
E. Anderssen,
A. Andreani,
A. Andreazza,
B. Axen,
J. Arguin,
M. Backhaus,
G. Balbi,
J. Ballansat,
M. Barbero,
G. Barbier,
A. Bassalat,
R. Bates,
P. Baudin,
M. Battaglia,
T. Beau,
R. Beccherle
, et al. (352 additional authors not shown)
Abstract:
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and i…
▽ More
During the shutdown of the CERN Large Hadron Collider in 2013-2014, an additional pixel layer was installed between the existing Pixel detector of the ATLAS experiment and a new, smaller radius beam pipe. The motivation for this new pixel layer, the Insertable B-Layer (IBL), was to maintain or improve the robustness and performance of the ATLAS tracking system, given the higher instantaneous and integrated luminosities realised following the shutdown. Because of the extreme radiation and collision rate environment, several new radiation-tolerant sensor and electronic technologies were utilised for this layer. This paper reports on the IBL construction and integration prior to its operation in the ATLAS detector.
△ Less
Submitted 6 June, 2018; v1 submitted 2 March, 2018;
originally announced March 2018.