Skip to main content

Showing 1–49 of 49 results for author: Cussonneau, J

Searching in archive physics. Search in all archives.
.
  1. arXiv:2402.10446  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    The XENONnT Dark Matter Experiment

    Authors: XENON Collaboration, E. Aprile, J. Aalbers, K. Abe, S. Ahmed Maouloud, L. Althueser, B. Andrieu, E. Angelino, J. R. Angevaare, V. C. Antochi, D. Antón Martin, F. Arneodo, M. Balata, L. Baudis, A. L. Baxter, M. Bazyk, L. Bellagamba, R. Biondi, A. Bismark, E. J. Brookes, A. Brown, S. Bruenner, G. Bruno, R. Budnik, T. K. Bui , et al. (170 additional authors not shown)

    Abstract: The multi-staged XENON program at INFN Laboratori Nazionali del Gran Sasso aims to detect dark matter with two-phase liquid xenon time projection chambers of increasing size and sensitivity. The XENONnT experiment is the latest detector in the program, planned to be an upgrade of its predecessor XENON1T. It features an active target of 5.9 tonnes of cryogenic liquid xenon (8.5 tonnes total mass in… ▽ More

    Submitted 15 February, 2024; originally announced February 2024.

    Comments: 32 pages, 19 figures

  2. arXiv:2309.11996  [pdf, other

    hep-ex physics.ins-det

    Design and performance of the field cage for the XENONnT experiment

    Authors: E. Aprile, K. Abe, S. Ahmed Maouloud, L. Althueser, B. Andrieu, E. Angelino, J. R. Angevaare, V. C. Antochi, D. Antón Martin, F. Arneodo, L. Baudis, A. L. Baxter, M. Bazyk, L. Bellagamba, R. Biondi, A. Bismark, E. J. Brookes, A. Brown, S. Bruenner, G. Bruno, R. Budnik, T. K. Bui, C. Cai, J. M. R. Cardoso, D. Cichon , et al. (139 additional authors not shown)

    Abstract: The precision in reconstructing events detected in a dual-phase time projection chamber depends on an homogeneous and well understood electric field within the liquid target. In the XENONnT TPC the field homogeneity is achieved through a double-array field cage, consisting of two nested arrays of field sha** rings connected by an easily accessible resistor chain. Rather than being connected to t… ▽ More

    Submitted 21 September, 2023; originally announced September 2023.

    Journal ref: Eur. Phys. J. C 84, 138 (2024)

  3. arXiv:2304.10931  [pdf, other

    hep-ex physics.ins-det

    Searching for Heavy Dark Matter near the Planck Mass with XENON1T

    Authors: E. Aprile, K. Abe, S. Ahmed Maouloud, L. Althueser, B. Andrieu, E. Angelino, J. R. Angevaare, V. C. Antochi, D. Antón Martin, F. Arneodo, L. Baudis, A. L. Baxter, M. Bazyk, L. Bellagamba, R. Biondi, A. Bismark, E. J. Brookes, A. Brown, S. Bruenner, G. Bruno, R. Budnik, T. K. Bui, C. Cai, J. M. R. Cardoso, D. Cichon , et al. (142 additional authors not shown)

    Abstract: Multiple viable theoretical models predict heavy dark matter particles with a mass close to the Planck mass, a range relatively unexplored by current experimental measurements. We use 219.4 days of data collected with the XENON1T experiment to conduct a blind search for signals from Multiply-Interacting Massive Particles (MIMPs). Their unique track signature allows a targeted analysis with only 0.… ▽ More

    Submitted 21 April, 2023; originally announced April 2023.

    Comments: 7 pages, 6 figures

    Journal ref: Phys. Rev. Lett. 130, 261002 (2023)

  4. arXiv:2303.14729  [pdf, other

    hep-ex astro-ph.CO astro-ph.IM hep-ph physics.ins-det

    First Dark Matter Search with Nuclear Recoils from the XENONnT Experiment

    Authors: XENON Collaboration, E. Aprile, K. Abe, F. Agostini, S. Ahmed Maouloud, L. Althueser, B. Andrieu, E. Angelino, J. R. Angevaare, V. C. Antochi, D. Antón Martin, F. Arneodo, L. Baudis, A. L. Baxter, M. Bazyk, L. Bellagamba, R. Biondi, A. Bismark, E. J. Brookes, A. Brown, S. Bruenner, G. Bruno, R. Budnik, T. K. Bui, C. Cai , et al. (141 additional authors not shown)

    Abstract: We report on the first search for nuclear recoils from dark matter in the form of weakly interacting massive particles (WIMPs) with the XENONnT experiment which is based on a two-phase time projection chamber with a sensitive liquid xenon mass of $5.9$ t. During the approximately 1.1 tonne-year exposure used for this search, the intrinsic $^{85}$Kr and $^{222}$Rn concentrations in the liquid targe… ▽ More

    Submitted 5 August, 2023; v1 submitted 26 March, 2023; originally announced March 2023.

    Comments: Limit points are included in the submission file

    Journal ref: Phys. Rev. Lett. 131, 041003 (2023)

  5. arXiv:2212.11032  [pdf, other

    physics.ins-det hep-ex

    The Triggerless Data Acquisition System of the XENONnT Experiment

    Authors: E. Aprile, J. Aalbers, K. Abe, F. Agostini, S. Ahmed Maouloud, L. Althueser, B. Andrieu, E. Angelino, J. R. Angevaare, V. C. Antochi, D. Antón Martin, F. Arneodo, L. Baudis, A. L. Baxter, L. Bellagamba, R. Biondi, A. Bismark, E. J. Brookes, A. Brown, S. Bruenner, G. Bruno, R. Budnik, T. K. Bui, C. Cai, J. M. R. Cardoso , et al. (140 additional authors not shown)

    Abstract: The XENONnT detector uses the latest and largest liquid xenon-based time projection chamber (TPC) operated by the XENON Collaboration, aimed at detecting Weakly Interacting Massive Particles and conducting other rare event searches. The XENONnT data acquisition (DAQ) system constitutes an upgraded and expanded version of the XENON1T DAQ system. For its operation, it relies predominantly on commerc… ▽ More

    Submitted 21 December, 2022; originally announced December 2022.

  6. arXiv:2211.14191  [pdf, other

    physics.ins-det hep-ex

    Low-energy Calibration of XENON1T with an Internal $^{37}$Ar Source

    Authors: E. Aprile, K. Abe, F. Agostini, S. Ahmed Maouloud, M. Alfonsi, L. Althueser, B. Andrieu, E. Angelino, J. R. Angevaare, V. C. Antochi, D. Antón Martin, F. Arneodo, L. Baudis, A. L. Baxter, L. Bellagamba, R. Biondi, A. Bismark, A. Brown, S. Bruenner, G. Bruno, R. Budnik, T. K. Bui, C. Cai, C. Capelli, J. M. R. Cardoso , et al. (139 additional authors not shown)

    Abstract: A low-energy electronic recoil calibration of XENON1T, a dual-phase xenon time projection chamber, with an internal $^{37}$Ar source was performed. This calibration source features a 35-day half-life and provides two mono-energetic lines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keV are measured to be (32.3$\pm$0.3) photons/keV and (40.6$\pm$0.5) electrons/keV, respecti… ▽ More

    Submitted 21 March, 2023; v1 submitted 25 November, 2022; originally announced November 2022.

  7. arXiv:2210.07231  [pdf, other

    hep-ex physics.ins-det

    An approximate likelihood for nuclear recoil searches with XENON1T data

    Authors: E. Aprile, K. Abe, F. Agostini, S. Ahmed Maouloud, M. Alfonsi, L. Althueser, B. Andrieu, E. Angelino, J. R. Angevaare, V. C. Antochi, D. Antón Martin, F. Arneodo, L. Baudis, A. L. Baxter, L. Bellagamba, R. Biondi, A. Bismark, A. Brown, S. Bruenner, G. Bruno, R. Budnik, C. Capelli, J. M. R. Cardoso, D. Cichon, B. Cimmino , et al. (129 additional authors not shown)

    Abstract: The XENON collaboration has published stringent limits on specific dark matter -nucleon recoil spectra from dark matter recoiling on the liquid xenon detector target. In this paper, we present an approximate likelihood for the XENON1T 1 tonne-year nuclear recoil search applicable to any nuclear recoil spectrum. Alongside this paper, we publish data and code to compute upper limits using the method… ▽ More

    Submitted 13 October, 2022; originally announced October 2022.

    Comments: Accepted by European Physical Journal C

  8. arXiv:2203.02309  [pdf, other

    physics.ins-det astro-ph.CO hep-ex nucl-ex

    A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics

    Authors: J. Aalbers, K. Abe, V. Aerne, F. Agostini, S. Ahmed Maouloud, D. S. Akerib, D. Yu. Akimov, J. Akshat, A. K. Al Musalhi, F. Alder, S. K. Alsum, L. Althueser, C. S. Amarasinghe, F. D. Amaro, A. Ames, T. J. Anderson, B. Andrieu, N. Angelides, E. Angelino, J. Angevaare, V. C. Antochi, D. Antón Martin, B. Antunovic, E. Aprile, H. M. Araújo , et al. (572 additional authors not shown)

    Abstract: The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neut… ▽ More

    Submitted 4 March, 2022; originally announced March 2022.

    Comments: 77 pages, 40 figures, 1262 references

    Report number: INT-PUB-22-003

    Journal ref: J. Phys. G: Nucl. Part. Phys. 50 (2023) 013001

  9. arXiv:2112.12231  [pdf, other

    physics.ins-det hep-ex

    Application and modeling of an online distillation method to reduce krypton and argon in XENON1T

    Authors: E. Aprile, K. Abe, F. Agostini, S. Ahmed Maouloud, M. Alfonsi, L. Althueser, E. Angelino, J. R. Angevaare, V. C. Antochi, D. Antón Martin, F. Arneodo, L. Baudis, A. L. Baxter, L. Bellagamba, A. Bernard, R. Biondi, A. Bismark, A. Brown, S. Bruenner, G. Bruno, R. Budnik, C. Capelli, J. M. R. Cardoso, D. Cichon, B. Cimmino , et al. (129 additional authors not shown)

    Abstract: A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based on a continuous purification of the gaseous volume of the detector system using the XENON1T cryogenic distillation column. A krypton-in-xenon concentration of… ▽ More

    Submitted 14 June, 2022; v1 submitted 22 December, 2021; originally announced December 2021.

    Journal ref: Prog Theor Exp Phys (2022)

  10. arXiv:2112.12116  [pdf, other

    hep-ex physics.ins-det

    Emission of Single and Few Electrons in XENON1T and Limits on Light Dark Matter

    Authors: E. Aprile, K. Abe, F. Agostini, S. Ahmed Maouloud, M. Alfonsi, L. Althueser, E. Angelino, J. R. Angevaare, V. C. Antochi, D. Antón Martin, F. Arneodo, L. Baudis, A. L. Baxter, L. Bellagamba, A. Bernard, R. Biondi, A. Bismark, A. Brown, S. Bruenner, G. Bruno, R. Budnik, C. Capelli, J. M. R. Cardoso, D. Cichon, B. Cimmino , et al. (130 additional authors not shown)

    Abstract: Delayed single- and few-electron emissions plague dual-phase time projection chambers, limiting their potential to search for light-mass dark matter. This paper examines the origins of these events in the XENON1T experiment. Characterization of the intensity of delayed electron backgrounds shows that the resulting emissions are correlated, in time and position, with high-energy events and can effe… ▽ More

    Submitted 28 June, 2022; v1 submitted 22 December, 2021; originally announced December 2021.

    Comments: 20 pages, 17 figures

    Journal ref: Phys. Rev. D 106, 022001 (2022)

  11. arXiv:2112.05629  [pdf, other

    physics.ins-det astro-ph.IM

    Material radiopurity control in the XENONnT experiment

    Authors: E. Aprile, K. Abe, F. Agostini, S. Ahmed Maouloud, M. Alfonsi, L. Althueser, E. Angelino, J. R. Angevaare, V. C. Antochi, D. Antón Martin, F. Arneodo, L. Baudis, A. L. Baxter, L. Bellagamba, R. Biondi, A. Bismark, A. Brown, S. Bruenner, G. Bruno, R. Budnik, C. Capelli, J. M. R. Cardoso, D. Cichon, B. Cimmino, M. Clark , et al. (128 additional authors not shown)

    Abstract: The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and $^{222}$Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove… ▽ More

    Submitted 26 January, 2023; v1 submitted 10 December, 2021; originally announced December 2021.

  12. arXiv:2009.13981  [pdf, other

    physics.ins-det hep-ex

    $^{222}$Rn emanation measurements for the XENON1T experiment

    Authors: E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, L. Althueser, F. D. Amaro, V. C. Antochi, E. Angelino, J. R. Angevaare, F. Arneodo, D. Barge, L. Baudis, B. Bauermeister, L. Bellagamba, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, C. Capelli, J. M. R. Cardoso, D. Cichon , et al. (118 additional authors not shown)

    Abstract: The selection of low-radioactive construction materials is of utmost importance for the success of low-energy rare event search experiments. Besides radioactive contaminants in the bulk, the emanation of radioactive radon atoms from material surfaces attains increasing relevance in the effort to further reduce the background of such experiments. In this work, we present the $^{222}$Rn emanation me… ▽ More

    Submitted 25 November, 2020; v1 submitted 29 September, 2020; originally announced September 2020.

    Comments: 14 pages, 3 figures

    Journal ref: Eur. Phys. J. C 81, 337 (2021)

  13. arXiv:2007.08796  [pdf, other

    physics.ins-det astro-ph.CO hep-ex

    Projected WIMP Sensitivity of the XENONnT Dark Matter Experiment

    Authors: The XENON collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, L. Althueser, F. D. Amaro, V. C. Antochi, E. Angelino, J. R. Angevaare, F. Arneodo, D. Barge, L. Baudis, B. Bauermeister, L. Bellagamba, M. L. Benabderrahmane, T. Berger, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, C. Capelli, J. M. R. Cardoso, D. Cichon , et al. (115 additional authors not shown)

    Abstract: XENONnT is a dark matter direct detection experiment, utilizing 5.9 t of instrumented liquid xenon, located at the INFN Laboratori Nazionali del Gran Sasso. In this work, we predict the experimental background and project the sensitivity of XENONnT to the detection of weakly interacting massive particles (WIMPs). The expected average differential background rate in the energy region of interest, c… ▽ More

    Submitted 17 November, 2020; v1 submitted 17 July, 2020; originally announced July 2020.

    Journal ref: JCAP11(2020)031

  14. arXiv:2006.03114  [pdf, other

    physics.ins-det astro-ph.SR hep-ex hep-ph

    Solar Neutrino Detection Sensitivity in DARWIN via Electron Scattering

    Authors: J. Aalbers, F. Agostini, S. E. M. Ahmed Maouloud, M. Alfonsi, L. Althueser, F. Amaro, J. Angevaare, V. C. Antochi, B. Antunovic, E. Aprile, L. Arazi, F. Arneodo, M. Balzer, L. Baudis, D. Baur, M. L. Benabderrahmane, Y. Biondi, A. Bismark, C. Bourgeois, A. Breskin, P. A. Breur, A. Brown, E. Brown, S. Brünner, G. Bruno , et al. (141 additional authors not shown)

    Abstract: We detail the sensitivity of the liquid xenon (LXe) DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five solar neutrino components: $pp$, $^7$Be, $^{13}$N, $^{15}$O and $pep$. The precision of the $^{13}$N, $^{15}$O and $pep$ components is hindered by the double-beta decay of $^{136}$Xe and, thus, would ben… ▽ More

    Submitted 20 December, 2020; v1 submitted 4 June, 2020; originally announced June 2020.

    Comments: 9 pages, 4 figures; for associated data files, see https://github.com/Physik-Institut-UZH/DARWIN-Sensitivity-Studies/tree/master/solar_neutrinos_electron_scattering

  15. arXiv:2003.13407  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Sensitivity of the DARWIN observatory to the neutrinoless double beta decay of $^{136}$Xe

    Authors: F. Agostini, S. E. M. Ahmed Maouloud, L. Althueser, F. Amaro, B. Antunovic, E. Aprile, L. Baudis, D. Baur, Y. Biondi, A. Bismark, P. A. Breur, A. Brown, G. Bruno, R. Budnik, C. Capelli, J. Cardoso, D. Cichon, M. Clark, A. P. Colijn, J. J. Cuenca-García, J. P. Cussonneau, M. P. Decowski, A. Depoian, J. Dierle, P. Di Gangi , et al. (70 additional authors not shown)

    Abstract: The DARWIN observatory is a proposed next-generation experiment to search for particle dark matter and for the neutrinoless double beta decay of $^{136}$Xe. Out of its 50$\,$t total natural xenon inventory, 40$\,$t will be the active target of a time projection chamber which thus contains about 3.6 t of $^{136}$Xe. Here, we show that its projected half-life sensitivity is $2.4\times10^{27}\,$yr, u… ▽ More

    Submitted 7 September, 2020; v1 submitted 25 March, 2020; originally announced March 2020.

    Comments: 12 pages, 9 figures

    Journal ref: Eur. Phys. J. C 80, 808 (2020)

  16. arXiv:2003.03825  [pdf, other

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    Energy resolution and linearity of XENON1T in the MeV energy range

    Authors: E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, L. Althueser, F. D. Amaro, V. C. Antochi, E. Angelino, J. Angevaare, F. Arneodo, D. Barge, L. Baudis, B. Bauermeister, L. Bellagamba, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, C. Capelli, J. M. R. Cardoso, D. Cichon , et al. (113 additional authors not shown)

    Abstract: Xenon dual-phase time projection chambers designed to search for Weakly Interacting Massive Particles have so far shown a relative energy resolution which degrades with energy above $\sim$200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of $^{136}$Xe at its $Q$-value, $Q_{ββ}\simeq$ 2.46 MeV. For the XEN… ▽ More

    Submitted 9 September, 2020; v1 submitted 8 March, 2020; originally announced March 2020.

    Comments: 9 pages, 7 figures

    Journal ref: Eur. Phys. J. C 80, 785 (2020)

  17. arXiv:1907.12771  [pdf, other

    hep-ex astro-ph.CO physics.ins-det

    Search for Light Dark Matter Interactions Enhanced by the Migdal effect or Bremsstrahlung in XENON1T

    Authors: E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, L. Althueser, F. D. Amaro, V. C. Antochi, E. Angelino, F. Arneodo, D. Barge, L. Baudis, B. Bauermeister, L. Bellagamba, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, C. Capelli, J. M. R. Cardoso, D. Cichon, D. Coderre , et al. (109 additional authors not shown)

    Abstract: Direct dark matter detection experiments based on a liquid xenon target are leading the search for dark matter particles with masses above $\sim$ 5 GeV/c$^2$, but have limited sensitivity to lighter masses because of the small momentum transfer in dark matter-nucleus elastic scattering. However, there is an irreducible contribution from inelastic processes accompanying the elastic scattering, whic… ▽ More

    Submitted 18 August, 2020; v1 submitted 30 July, 2019; originally announced July 2019.

    Journal ref: Phys. Rev. Lett. 123, 241803 (2019)

  18. arXiv:1906.04717  [pdf, other

    physics.ins-det hep-ex

    XENON1T Dark Matter Data Analysis: Signal Reconstruction, Calibration and Event Selection

    Authors: E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, L. Althueser, F. D. Amaro, V. C. Antochi, F. Arneodo, L. Baudis, B. Bauermeister, L. Bellagamba, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, C. Capelli, J. M. R. Cardoso, D. Cichon, D. Coderre, A. P. Colijn, J. Conrad , et al. (103 additional authors not shown)

    Abstract: The XENON1T experiment at the Laboratori Nazionali del Gran Sasso is the most sensitive direct detection experiment for dark matter in the form of weakly interacting particles (WIMPs) with masses above $6\,$GeV/$c^2$ scattering off nuclei. The detector employs a dual-phase time projection chamber with 2.0 metric tons of liquid xenon in the target. A one metric $\mathrm{ton}\times\mathrm{year}$ exp… ▽ More

    Submitted 4 November, 2019; v1 submitted 11 June, 2019; originally announced June 2019.

    Journal ref: Phys. Rev. D 100, 052014 (2019)

  19. The XENON1T Data Acquisition System

    Authors: E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, L. Althueser, F. D. Amaro, V. C. Antochi, F. Arneodo, D. Barge, L. Baudis, B. Bauermeister, L. Bellagamba, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Bütikofer, C. Capelli, J. M. R. Cardoso, D. Cichon, D. Coderre , et al. (108 additional authors not shown)

    Abstract: The XENON1T liquid xenon time projection chamber is the most sensitive detector built to date for the measurement of direct interactions of weakly interacting massive particles with normal matter. The data acquisition system (DAQ) is constructed from commercial, open source, and custom components to digitize signals from the detector and store them for later analysis. The system achieves an extrem… ▽ More

    Submitted 7 August, 2019; v1 submitted 3 June, 2019; originally announced June 2019.

    Comments: 14 pages, 6 figures, submitted to JINST; Version 2 with minor updates to text

    Journal ref: JINST 14 (2019) no.07, P07016

  20. arXiv:1902.11297  [pdf, other

    physics.ins-det hep-ex

    XENON1T Dark Matter Data Analysis: Signal & Background Models, and Statistical Inference

    Authors: E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, L. Althueser, F. D. Amaro, V. C. Antochi, F. Arneodo, L. Baudis, B. Bauermeister, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, C. Capelli, J. M. R. Cardoso, D. Cichon, D. Coderre, A. P. Colijn, J. Conrad, J. P. Cussonneau , et al. (101 additional authors not shown)

    Abstract: The XENON1T experiment searches for dark matter particles through their scattering off xenon atoms in a 2 tonne liquid xenon target. The detector is a dual-phase time projection chamber, which measures simultaneously the scintillation and ionization signals produced by interactions in target volume, to reconstruct energy and position, as well as the type of the interaction. The background rate in… ▽ More

    Submitted 28 February, 2019; v1 submitted 28 February, 2019; originally announced February 2019.

    Journal ref: Phys. Rev. D 99, 112009 (2019)

  21. arXiv:1805.12562  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex hep-ph physics.ins-det

    Dark Matter Search Results from a One Tonne$\times$Year Exposure of XENON1T

    Authors: E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, L. Althueser, F. D. Amaro, M. Anthony, F. Arneodo, L. Baudis, B. Bauermeister, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, C. Capelli, J. M. R. Cardoso, D. Cichon, D. Coderre, A. P. Colijn, J. Conrad , et al. (95 additional authors not shown)

    Abstract: We report on a search for Weakly Interacting Massive Particles (WIMPs) using 278.8 days of data collected with the XENON1T experiment at LNGS. XENON1T utilizes a liquid xenon time projection chamber with a fiducial mass of $(1.30 \pm 0.01)$ t, resulting in a 1.0 t$\times$yr exposure. The energy region of interest, [1.4, 10.6] $\mathrm{keV_{ee}}$ ([4.9, 40.9] $\mathrm{keV_{nr}}$), exhibits an ultra… ▽ More

    Submitted 13 September, 2018; v1 submitted 31 May, 2018; originally announced May 2018.

    Comments: 8 pages, 5 figures, v2 limit points as csv

    Journal ref: Phys. Rev. Lett. 121, 111302 (2018)

  22. arXiv:1709.10149  [pdf, other

    astro-ph.IM physics.ins-det

    Signal Yields of keV Electronic Recoils and Their Discrimination from Nuclear Recoils in Liquid Xenon

    Authors: E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, F. Arneodo, P. Barrow, L. Baudis, B. Bauermeister, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Bütikofer, J. Calvén, J. M. R. Cardoso, M. Cervantes, D. Cichon, D. Coderre, A. P. Colijn , et al. (94 additional authors not shown)

    Abstract: We report on the response of liquid xenon to low energy electronic recoils below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method based on Markov Chain Monte Carlo is used to extract the photon yields and recombination fluctuations from the experimental data. The photon yields measured at the two l… ▽ More

    Submitted 1 February, 2018; v1 submitted 28 September, 2017; originally announced September 2017.

    Journal ref: Phys. Rev. D 97, 092007 (2018)

  23. arXiv:1708.07051  [pdf, other

    astro-ph.IM astro-ph.CO hep-ex physics.ins-det

    The XENON1T Dark Matter Experiment

    Authors: XENON Collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, B. Antunes, F. Arneodo, M. Balata, P. Barrow, L. Baudis, B. Bauermeister, M. L. Benabderrahmane, T. Berger, A. Breskin, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Bütikofer, J. Calvén, J. M. R. Cardoso , et al. (120 additional authors not shown)

    Abstract: The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is the first WIMP dark matter detector operating with a liquid xenon target mass above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute the active target of the dual-phase time projection chamber. The scintillation and ionization signals from particle interactions are detected with low-background photomu… ▽ More

    Submitted 23 August, 2017; originally announced August 2017.

    Comments: 22 pages, 25 figures

  24. arXiv:1708.03617  [pdf, other

    astro-ph.IM physics.ins-det

    Intrinsic backgrounds from Rn and Kr in the XENON100 experiment

    Authors: XENON Collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, F. Arneodo, P. Barrow, L. Baudis, B. Bauermeister, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Bütikofer, J. Calvén, J. M. R. Cardoso, M. Cervantes, D. Cichon, D. Coderre , et al. (93 additional authors not shown)

    Abstract: In this paper, we describe the XENON100 data analyses used to assess the target-intrinsic background sources radon ($^{222}$Rn), thoron ($^{220}$Rn) and krypton ($^{85}$Kr). We detail the event selections of high-energy alpha particles and decay-specific delayed coincidences. We derive distributions of the individual radionuclides inside the detector and quantify their abundances during the main t… ▽ More

    Submitted 3 March, 2018; v1 submitted 11 August, 2017; originally announced August 2017.

    Comments: v1: 11 pages, 5 figures, 4 tables; v2: 12 pages, 5 figures, 4 tables, article updated after referee process

    Journal ref: Eur. Phys. J. C (2018) 78:132

  25. arXiv:1705.05830  [pdf, other

    hep-ex astro-ph.CO physics.ins-det

    Search for WIMP Inelastic Scattering off Xenon Nuclei with XENON100

    Authors: E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, F. Arneodo, P. Barrow, L. Baudis, B. Bauermeister, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Bütikofer, J. Calvén, J. M. R. Cardoso, M. Cervantes, D. Cichon, D. Coderre, A. P. Colijn , et al. (91 additional authors not shown)

    Abstract: We present the first constraints on the spin-dependent, inelastic scattering cross section of Weakly Interacting Massive Particles (WIMPs) on nucleons from XENON100 data with an exposure of 7.64$\times$10$^3$\,kg\,day. XENON100 is a dual-phase xenon time projection chamber with 62\,kg of active mass, operated at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy and designed to search for nuc… ▽ More

    Submitted 1 May, 2017; originally announced May 2017.

    Journal ref: Phys. Rev. D 96, 022008 (2017)

  26. Material radioassay and selection for the XENON1T dark matter experiment

    Authors: XENON Collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, F. Arneodo, P. Barrow, L. Baudis, B. Bauermeister, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Bütikofer, J. Calven, J. M. R. Cardoso, M. Cervantes, D. Cichon, D. Coderre , et al. (96 additional authors not shown)

    Abstract: The XENON1T dark matter experiment aims to detect Weakly Interacting Massive Particles (WIMPs) through low-energy interactions with xenon atoms. To detect such a rare event necessitates the use of radiopure materials to minimize the number of background events within the expected WIMP signal region. In this paper we report the results of an extensive material radioassay campaign for the XENON1T ex… ▽ More

    Submitted 4 May, 2017; originally announced May 2017.

  27. arXiv:1704.05804  [pdf, other

    astro-ph.CO physics.ins-det

    Search for magnetic inelastic dark matter with XENON100

    Authors: XENON collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, F. Arneodo, P. Barrow, L. Baudis, B. Bauermeister, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Bütikofer, J. Calvén, J. M. R. Cardoso, M. Cervantes, D. Cichon, D. Coderre , et al. (90 additional authors not shown)

    Abstract: We present the first search for dark matter-induced delayed coincidence signals in a dual-phase xenon time projection chamber, using the 224.6 live days of the XENON100 science run II. This very distinct signature is predicted in the framework of magnetic inelastic dark matter which has been proposed to reconcile the modulation signal reported by the DAMA/LIBRA collaboration with the null results… ▽ More

    Submitted 31 October, 2017; v1 submitted 19 April, 2017; originally announced April 2017.

    Comments: 10 pages, 6 figures

    Journal ref: JCAP10(2017)039

  28. Online $^{222}$Rn removal by cryogenic distillation in the XENON100 experiment

    Authors: XENON Collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, F. Arneodo, P. Barrow, L. Baudis, B. Bauermeister, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Bütikofer, J. Calvén, J. M. R. Cardoso, M. Cervantes, D. Cichon, D. Coderre , et al. (97 additional authors not shown)

    Abstract: We describe the purification of xenon from traces of the radioactive noble gas radon using a cryogenic distillation column. The distillation column is integrated into the gas purification loop of the XENON100 detector for online radon removal. This enabled us to significantly reduce the constant $^{222}$Rn background originating from radon emanation. After inserting an auxiliary $^{222}$Rn emanati… ▽ More

    Submitted 2 June, 2017; v1 submitted 22 February, 2017; originally announced February 2017.

    Journal ref: Eur. Phys. J. C (2017) 77: 358

  29. arXiv:1701.00769  [pdf, other

    astro-ph.CO astro-ph.IM hep-ex physics.ins-det

    Search for Electronic Recoil Event Rate Modulation with 4 Years of XENON100 Data

    Authors: The XENON collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, F. Arneodo, P. Barrow, L. Baudis, B. Bauermeister, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Butikofer, J. Calven, J. M. R. Cardoso, M. Cervantes, D. Cichon, D. Coderre , et al. (89 additional authors not shown)

    Abstract: We report on a search for electronic recoil event rate modulation signatures in the XENON100 data accumulated over a period of 4 years, from January 2010 to January 2014. A profile likelihood method, which incorporates the stability of the XENON100 detector and the known electronic recoil background model, is used to quantify the significance of periodicity in the time distribution of events. Ther… ▽ More

    Submitted 3 January, 2017; originally announced January 2017.

    Comments: 6 pages, 5 figures

    Journal ref: Phys. Rev. Lett. 118, 101101 (2017)

  30. Removing krypton from xenon by cryogenic distillation to the ppq level

    Authors: XENON Collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, F. Arneodo, P. Barrow, L. Baudis, B. Bauermeister, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Bütikofer, J. Calvén, J. M. R. Cardoso, M. Cervantes, D. Cichon, D. Coderre , et al. (97 additional authors not shown)

    Abstract: The XENON1T experiment aims for the direct detection of dark matter in a cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired sensitivity, the background induced by radioactive decays inside the detector has to be sufficiently low. One major contributor is the $β$-emitter $^{85}$Kr which is an intrinsic contamination of the xenon. For the XENON1T experiment a concentratio… ▽ More

    Submitted 8 May, 2017; v1 submitted 13 December, 2016; originally announced December 2016.

    Journal ref: Eur. Phys. J. C (2017) 77: 275

  31. Results from a Calibration of XENON100 Using a Source of Dissolved Radon-220

    Authors: The XENON Collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, F. Arneodo, P. Barrow, L. Baudis, B. Bauermeister, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Butikofer, J. Calven, J. M. R. Cardoso, M. Cervantes, D. Cichon, D. Coderre , et al. (96 additional authors not shown)

    Abstract: A Rn-220 source is deployed on the XENON100 dark matter detector in order to address the challenges in calibration of tonne-scale liquid noble element detectors. We show that the Pb-212 beta emission can be used for low-energy electronic recoil calibration in searches for dark matter. The isotope spreads throughout the entire active region of the detector, and its activity naturally decays below b… ▽ More

    Submitted 25 April, 2017; v1 submitted 10 November, 2016; originally announced November 2016.

    Journal ref: Phys. Rev. D 95, 072008 (2017)

  32. arXiv:1609.06154  [pdf, other

    astro-ph.CO physics.ins-det

    XENON100 Dark Matter Results from a Combination of 477 Live Days

    Authors: XENON100 Collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, F. Arneodo, P. Barrow, L. Baudis, B. Bauermeister, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Bütikofer, J. Calvén, J. M. R. Cardoso, M. Cervantes, D. Cichon, D. Coderre , et al. (92 additional authors not shown)

    Abstract: We report on WIMP search results of the XENON100 experiment, combining three runs summing up to 477 live days from January 2010 to January 2014. Data from the first two runs were already published. A blind analysis was applied to the last run recorded between April 2013 and January 2014 prior to combining the results. The ultra-low electromagnetic background of the experiment, ~$5 \times 10^{-3}$… ▽ More

    Submitted 12 January, 2017; v1 submitted 20 September, 2016; originally announced September 2016.

    Comments: 12 pages, 13 figures, 2 tables, Limit data points in TeX

    Journal ref: Phys. Rev. D 94, 122001 (2016)

  33. arXiv:1609.03354  [pdf, other

    nucl-ex physics.ins-det

    Search for Two-Neutrino Double Electron Capture of $^{124}$Xe with XENON100

    Authors: The XENON Collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, F. Arneodo, P. Barrow, L. Baudis, B. Bauermeister, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Bütikofer, J. Calvén, J. M. R. Cardoso, M. Cervantes, D. Cichon, D. Coderre , et al. (92 additional authors not shown)

    Abstract: Two-neutrino double electron capture is a rare nuclear decay where two electrons are simultaneously captured from the atomic shell. For $^{124}$Xe this process has not yet been observed and its detection would provide a new reference for nuclear matrix element calculations. We have conducted a search for two-neutrino double electron capture from the K-shell of $^{124}$Xe using 7636 kg$\cdot$d of d… ▽ More

    Submitted 16 February, 2017; v1 submitted 12 September, 2016; originally announced September 2016.

    Comments: 6 pages, 4 figures

    Journal ref: Phys. Rev. C 95, 024605, Published 13 February 2017

  34. arXiv:1606.07001  [pdf, other

    astro-ph.IM hep-ex physics.ins-det

    DARWIN: towards the ultimate dark matter detector

    Authors: J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, C. Amsler, E. Aprile, L. Arazi, F. Arneodo, P. Barrow, L. Baudis, M. L. Benabderrahmane, T. Berger, B. Beskers, A. Breskin, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Buetikofer, J. Calven, J. M. R. Cardoso, D. Cichon, D. Coderre , et al. (94 additional authors not shown)

    Abstract: DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary goal will be to explore the experimentally accessible parameter space for Weakly Interacting Massive Particles (WIMPs) in a wide mass-range, until neutrino interactions with the target become an irreducible… ▽ More

    Submitted 22 June, 2016; originally announced June 2016.

    Comments: 36 pages, 11 figures

    Journal ref: JCAP 1611 (2016) no.11, 017

  35. arXiv:1605.06262  [pdf, other

    astro-ph.CO hep-ex hep-ph physics.ins-det

    A low-mass dark matter search using ionization signals in XENON100

    Authors: XENON100 Collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, F. Arneodo, P. Barrow, L. Baudis, B. Bauermeister, M. L. Benabderrahmane, T. Berger, P. A. Breur, A. Brown, E. Brown S. Bruenner, G. Bruno, R. Budnik, A. Buss, L. Bütikofer, J. M. R. Cardoso, M. Cervantes, D. Cichon, D. Coderre, A. P. Colijn , et al. (86 additional authors not shown)

    Abstract: We perform a low-mass dark matter search using an exposure of 30\,kg$\times$yr with the XENON100 detector. By drop** the requirement of a scintillation signal and using only the ionization signal to determine the interaction energy, we lowered the energy threshold for detection to 0.7\,keV for nuclear recoils. No dark matter detection can be claimed because a complete background model cannot be… ▽ More

    Submitted 19 December, 2016; v1 submitted 20 May, 2016; originally announced May 2016.

    Comments: 6 pages; 7 figures; PRD. Additional file in source material, s2stot, contains the full list of events passing all selection cuts. Limit data points in TeX; Corrected LUX points used for comparison and respective reference in figure 5

    Journal ref: Phys. Rev. D 94, 092001 (2016)

  36. arXiv:1512.07501  [pdf, other

    physics.ins-det astro-ph.CO

    Physics reach of the XENON1T dark matter experiment

    Authors: The XENON collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, F. D. Amaro, M. Anthony, L. Arazi, F. Arneodo, C. Balan, P. Barrow, L. Baudis, B. Bauermeister, T. Berger, P. Breur, A. Breskin, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Bütikofer, J. M. R. Cardoso, M. Cervantes, D. Cichon , et al. (91 additional authors not shown)

    Abstract: The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds. The total electronic recoil background in $1$ tonne fiducial volume and (… ▽ More

    Submitted 15 April, 2016; v1 submitted 23 December, 2015; originally announced December 2015.

    Comments: 36 pages, 18 figures, published by JCAP

    Journal ref: JCAP04(2016)027

  37. arXiv:1507.07748  [pdf, other

    astro-ph.CO hep-ex physics.ins-det

    Search for Event Rate Modulation in XENON100 Electronic Recoil Data

    Authors: The XENON Collaboration, E. Aprile, J. Aalbers, F. Agostini, M. Alfonsi, M. Anthony, L. Arazi, K. Arisaka, F. Arneodo, C. Balan, P. Barrow, L. Baudis, B. Bauermeister, P. A. Breur, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Buetikofer, J. M. R. Cardoso, M. Cervantes, D. Coderre, A. P. Colijn, H. Contreras , et al. (77 additional authors not shown)

    Abstract: We have searched for periodic variations of the electronic recoil event rate in the (2-6) keV energy range recorded between February 2011 and March 2012 with the XENON100 detector, adding up to 224.6 live days in total. Following a detailed study to establish the stability of the detector and its background contributions during this run, we performed an un-binned profile likelihood analysis to ide… ▽ More

    Submitted 28 July, 2015; originally announced July 2015.

    Comments: 6 pages, 4 figures

    Journal ref: Phys. Rev. Lett. 115, 091302 (2015)

  38. arXiv:1503.07698  [pdf, other

    astro-ph.IM physics.ins-det

    Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment

    Authors: E. Aprile, F. Agostini, M. Alfonsi, L. Arazi, K. Arisaka, F. Arneodo, M. Auger, C. Balan, P. Barrow, L. Baudis, B. Bauermeister, A. Behrens, P. Beltrame, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, L. Buetikofer, J. M. R. Cardoso, D. Coderre, A. P. Colijn, H. Contreras, J. P. Cussonneau, M. P. Decowksi , et al. (73 additional authors not shown)

    Abstract: The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experime… ▽ More

    Submitted 26 March, 2015; originally announced March 2015.

    Comments: 10 pages, 5 figures

  39. arXiv:1406.2374  [pdf, other

    astro-ph.IM physics.ins-det

    Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment

    Authors: E. Aprile, F. Agostini, M. Alfonsi, K. Arisaka, F. Arneodo, M. Auger, C. Balan, P. Barrow, L. Baudis, B. Bauermeister, A. Behrens, P. Beltrame, K. Bokeloh, A. Breskin, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, J. M. R. Cardoso, A. P. Colijn, H. Contreras, J. P. Cussonneau, M. P. Decowski, E. Duchovni , et al. (66 additional authors not shown)

    Abstract: XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~ \mathrm{cm}^{\mathrm{2}}$ for W… ▽ More

    Submitted 25 February, 2015; v1 submitted 9 June, 2014; originally announced June 2014.

    Journal ref: JINST 9, P11006 (2014)

  40. arXiv:1311.1088  [pdf, ps, other

    physics.ins-det astro-ph.IM hep-ex

    Observation and applications of single-electron charge signals in the XENON100 experiment

    Authors: E. Aprile, M. Alfonsi, K. Arisaka, F. Arneodo, C. Balan, L. Baudis, B. Bauermeister, A. Behrens, P. Beltrame, K. Bokeloh, A. Brown, E. Brown, S. Bruenner, G. Bruno, R. Budnik, J. M. R. Cardoso, W. -T. Chen, B. Choi, A. P. Colijn, H. Contreras, J. P. Cussonneau, M. P. Decowski, E. Duchovni, S. Fattori, A. D. Ferella , et al. (55 additional authors not shown)

    Abstract: The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector… ▽ More

    Submitted 28 January, 2014; v1 submitted 5 November, 2013; originally announced November 2013.

    Comments: 16 pages, 8 figures. Accepted for publication in Journal of Physics G: Nuclear and Particle Physics

    Journal ref: E Aprile et al. [XENON100 Collaboration], J. Phys. G: Nucl. Part. Phys. 41 (2014) 035201

  41. arXiv:1306.2303  [pdf, other

    astro-ph.IM physics.ins-det

    The neutron background of the XENON100 dark matter experiment

    Authors: E. Aprile, M. Alfonsi, K. Arisaka, F. Arneodo, C. Balan, L. Baudis, B. Bauermeister, A. Behrens, P. Beltrame, K. Bokeloh, A. Brown, E. Brown, G. Bruno, R. Budnik, J. M. R. Cardoso, W. -T. Chen, B. Choi, A. P. Colijn, H. Contreras, J. P. Cussonneau, M. P. Decowski, E. Duchovni, S. Fattori, A. D. Ferella, W. Fulgione , et al. (52 additional authors not shown)

    Abstract: The XENON100 experiment, installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. This paper presents a study on the nuclear recoil background of the experiment, taking into account neutron backgrounds from ($α$,n) and spontaneous fission re… ▽ More

    Submitted 2 September, 2013; v1 submitted 10 June, 2013; originally announced June 2013.

  42. arXiv:1211.0836  [pdf, other

    astro-ph.IM physics.ins-det

    The distributed Slow Control System of the XENON100 Experiment

    Authors: E. Aprile, M. Alfonsi, K. Arisaka, F. Arneodo, C. Balan, L. Baudis, A. Behrens, P. Beltrame, K. Bokeloh, E. Brown, G. M. Bruno, R. Budnik, M. Le Calloch, J. M. Cardoso, W. -T. Chen, B. Choi, H. Contreras, J. -P. Cussonneau, M. P. Decowski, E. Duchovni, S. Fattori, A. D. Ferella, W. Fulgione, F. Gao, M. Garbini , et al. (50 additional authors not shown)

    Abstract: The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, was designed to search for evidence of dark matter interactions inside a volume of liquid xenon using a dual-phase time projection chamber. This paper describes the Slow Control System (SCS) of the experiment with emphasis on the distributed architecture as well as on its modular and expandable nature… ▽ More

    Submitted 5 November, 2012; originally announced November 2012.

    Comments: 12 pages, 4 figures

  43. arXiv:1207.5988  [pdf, other

    astro-ph.CO hep-ex hep-ph physics.ins-det

    Dark Matter Results from 225 Live Days of XENON100 Data

    Authors: XENON100 Collaboration, E. Aprile, M. Alfonsi, K. Arisaka, F. Arneodo, C. Balan, L. Baudis, B. Bauermeister, A. Behrens, P. Beltrame, K. Bokeloh, E. Brown, G. Bruno, R. Budnik, J. M. R. Cardoso, W. -T. Chen, B. Choi, D. Cline, A. P. Colijn, H. Contreras, J. P. Cussonneau, M. P. Decowski, E. Duchovni, S. Fattori, A. D. Ferella , et al. (53 additional authors not shown)

    Abstract: We report on a search for particle dark matter with the XENON100 experiment, operated at the Laboratori Nazionali del Gran Sasso (LNGS) for 13 months during 2011 and 2012. XENON100 features an ultra-low electromagnetic background of (5.3 \pm 0.6) \times 10^-3 events (kg day keVee)^-1 in the energy region of interest. A blind analysis of 224.6 live days \times 34 kg exposure has yielded no evidence… ▽ More

    Submitted 20 March, 2013; v1 submitted 25 July, 2012; originally announced July 2012.

    Comments: 6 pages, 5 figures. Matches version accepted by PRL. Includes limits up to 10 TeV/c^2, published as supplementary material: http://prl.aps.org/supplemental/PRL/v109/i18/e181301 Please cite high mass limits as "Phys. Rev. Lett. 109, 181301 (2012), online supplementary material."

    Journal ref: Phys. Rev. Lett. 109, 181301 (2012)

  44. arXiv:1207.3458  [pdf, other

    astro-ph.IM physics.ins-det

    Analysis of the XENON100 Dark Matter Search Data

    Authors: The XENON100 Collaboration, E. Aprile, M. Alfonsi, K. Arisaka, F. Arneodo, C. Balan, L. Baudis, A. Behrens, P. Beltrame, K. Bokeloh, E. Brown, G. Bruno, R. Budnik, J. M. R. Cardoso, W. -T. Chen, B. Choi, D. B. Cline, H. Contreras, J. P. Cussonneau, M. P. Decowski, E. Duchovni, S. Fattori, A. D. Ferella, W. Fulgione, F. Gao , et al. (49 additional authors not shown)

    Abstract: The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso, aims at the direct detection of dark matter in the form of weakly interacting massive particles (WIMPs), based on their interactions with xenon nuclei in an ultra low background dual-phase time projection chamber. This paper describes the general methods developed for the analysis of the XENON100 data. These methods have… ▽ More

    Submitted 14 October, 2013; v1 submitted 14 July, 2012; originally announced July 2012.

    Comments: 18 pages, 17 figures, information for the 224.6 live days run included

    Journal ref: Astropart. Phys. 54 (2014) 11-24

  45. arXiv:1205.3874  [pdf

    astro-ph.IM physics.ins-det

    Improvement of xenon purification system using a combination of a pulse tube refrigerator and a coaxial heat exchanger

    Authors: Wan-Ting Chen, D. Chbib, J. -P. Cussonneau, J. Donnard, S. Duval, O. Lemaire, M. Le Calloch, P. Le Ray, A. -F. Mohamad-Hadi, E. Morteau, T. Oger, L. Scotto-Lavina, J. -S. Stutzmann, D. Thers, P. Briend, T. Haruyama, S. Mihara, T. Tauchi

    Abstract: We have developed a compact cryogenic system with a pulse tube refrigerator and a coaxial heat exchanger. This liquefaction-purification system not only saves the cooling power used to reach high gaseous recirculation rate, but also reduces the impurity level with high speed. The heat exchanger operates with an efficiency of 99%, which indicates the possibility for fast xenon gas recirculation in… ▽ More

    Submitted 17 May, 2012; originally announced May 2012.

    Journal ref: Proceeding of ICEC24-ICMC2012

  46. arXiv:1110.6053  [pdf

    physics.ins-det nucl-ex

    Hybrid Multi Micropattern Gaseous Photomultiplier for detection of liquid-xenon scintillation

    Authors: Samuel Duval, Lior Arazi, Amos Breskin, Ranny Budnik, Wan-Ting Chen, Hervé Carduner, A. E. C. Coimbra, Marco Cortesi, Roy Kaner, Jean-Pierre Cussonneau, Jérôme Donnard, Jacob Lamblin, Olivier Lemaire, Patrick Le Ray, J. A. M. Lopes, Abdul-Fattah Mohamad Hadi, Eric Morteau, Tugdual Oger, J. M. F. dos Santos, Luca Scotto Lavina, Jean-Sébastien Stutzmann, Dominique Thers

    Abstract: Gaseous PhotoMultipliers (GPM) are a very promising alternative of vacuum PMTs especially for large-size noble-liquid detectors in the field of Functional Nuclear Medical Imaging and Direct Dark Matter Detection. We present recent characterization results of a Hybrid-GPM made of three Micropattern Gaseous Structures; a Thick Gaseous Electron Multiplier (THGEM), a Parallel Ionization Multiplier (PI… ▽ More

    Submitted 27 October, 2011; originally announced October 2011.

    Comments: 7 pages, 6 figures, Proceeding of the NDIP Conference 2011 to be published in NIM A

  47. A liquid xenon TPC for a medical imaging Compton telescope

    Authors: T. Oger, W-T. Chen, J-P. Cussonneau, J. Donnard, S. Duval, J. Lamblin, O. Lemaire, A. F. Mohamad Hadi, P. Le Ray, E. Morteau, L. Scotto Lavina, J-S. Stutzmann, D. Thers

    Abstract: A new technique for medical imaging, "3γ imaging", is studied by our group at SUBATECH for few years. A small liquid xenon time projection chamber prototype has been built in order to demonstrate the feasibility of this technique. With an ultra-low-noise front-end electronics, the energy deposit and resolution of 511 keV γ-ray as a function of drift electric field (E) is measured with high precisi… ▽ More

    Submitted 5 December, 2011; v1 submitted 16 September, 2011; originally announced September 2011.

    Comments: 8 pages, 8 figures, Proceeding of 6th international conference on New Developments In Photodetection, Lyon, 4-8 July 2011

  48. arXiv:1109.3300  [pdf

    physics.ins-det

    Measurement of the transverse diffusion coefficient of charge in liquid xenon

    Authors: W. -T. Chen, H. Carduner, J. -P. Cussonneau, J. Donnard, S. Duval, A. -F. Mohamad-Hadi, J. Lamblin, O. Lemaire, P. Le Ray, E. Morteau, T. Oger, L. Scotto-Lavina, J. -S. Stutzmann, D. Thers

    Abstract: Liquid xenon (LXe) is a very attractive material as a detection medium for ionization detectors due to its high density, high atomic number, and low energy required to produce electron-ion pairs. Therefore it has been used in several applications, like γ detection or direct detection of dark matter. Now Subatech is working on the R & D of LXe Compton telescope for 3γ medical imaging, which can mak… ▽ More

    Submitted 15 September, 2011; originally announced September 2011.

    Comments: 6 pages, 6 figures, proceeding of DSL-2011

  49. On the operation of a Micropattern Gaseous UV-Photomultiplier in Liquid-Xenon

    Authors: S. Duval, A. Breskin, R. Budnik, W. T. Chen, H. Carduner, M. Cortesi, J. P. Cussonneau, J. Donnard, J. Lamblin, P. Le Ray, E. Morteau, T. Oger, J. S. Stutzmann, D. Thers

    Abstract: Operation results are presented of a UV-sensitive gaseous photomultiplier (GPM) coupled through a MgF2 window to a liquid-xenon scintillator. It consisted of a reflective CsI photocathode deposited on top of a THick Gaseous Electron Multiplier (THGEM); further multiplication stages were either a second THGEM or a Parallel Ionization Multiplier (PIM) followed by a MICROMEsh GAseous Structure (MICRO… ▽ More

    Submitted 20 January, 2011; v1 submitted 19 January, 2011; originally announced January 2011.

    Comments: 12 pages, 9 figures, submitted to JINST

    Journal ref: JINST 6:P04007,2011