First ClearMind gamma detector prototype for TOF-PET imaging
Authors:
A. Galindo-Tellez,
V. Sharyy,
C. -H. Sung,
M. Follin,
L. Cappellugola,
S. Curtoni,
M. Dupont,
C. Morel,
D. Breton,
J. Maalmi,
D. Yvon
Abstract:
The ClearMind project aims to develop a TOF-PET position-sensitive detection module optimized for time and spatial resolutions and detection efficiency. For this, we use a 59 mm $\times$ 59 mm $\times$ 5 mm monolithic PbWO$_4$ (PWO) crystal, which is encapsulated within a commercial Micro-Channel Plate Photomultiplier tube MAPMT253 with a bialkali photocathode directly deposited on the crystal. We…
▽ More
The ClearMind project aims to develop a TOF-PET position-sensitive detection module optimized for time and spatial resolutions and detection efficiency. For this, we use a 59 mm $\times$ 59 mm $\times$ 5 mm monolithic PbWO$_4$ (PWO) crystal, which is encapsulated within a commercial Micro-Channel Plate Photomultiplier tube MAPMT253 with a bialkali photocathode directly deposited on the crystal. We report the proof of concept of the directly deposited of a bialkali photocathode on a PWO crystal and its stability over time. The full calibration of the ClearMind photodetector module in the single-photoelectron regime is described. We measured a time resolution of 70 ps FWHM using a 20 ps pulsed laser. We present the performance of the prototype used in coincidence with a 3 $\times$ 3 $\times$ 3 mm$^3$ LYSO:Ca,Ce crystal readout by a SiPM. We obtained a coincidence time resolution of 350 ps FWHM, a spatial resolution of 4 to 5 mm, and a detection efficiency of 28 %, consistent with Monte Carlo simulations of the ClearMind detector module.
△ Less
Submitted 27 June, 2024; v1 submitted 20 December, 2023;
originally announced December 2023.
-
Detailed simulation for the ClearMind prototype detection module and event reconstruction using artificial intelligence
Authors:
Chi-Hsun Sung,
Laurie Cappellugola,
Megane Follin,
Sébastien Curtoni,
Mathieu Dupont,
Christian Morel,
Aline Galindo-Tellez,
Roman Chyzh,
Dominique Breton,
Jihane Maalmi,
Dominique Yvon,
Viatcheslav Sharyy
Abstract:
The ClearMind project aims to develop the TOF-PET position sensitive detection module optimized for the time resolution, spatial resolution, and detection efficiency. For this, the ClearMind project uses a large (59 $\times$ 59 mm$^2$) monolithic PbWO$_4$ (PWO) scintillating crystal with a bialkali photo-electric layer deposited directly on the crystal. Scintillation and Cherenkov photons result t…
▽ More
The ClearMind project aims to develop the TOF-PET position sensitive detection module optimized for the time resolution, spatial resolution, and detection efficiency. For this, the ClearMind project uses a large (59 $\times$ 59 mm$^2$) monolithic PbWO$_4$ (PWO) scintillating crystal with a bialkali photo-electric layer deposited directly on the crystal. Scintillation and Cherenkov photons result together from the 511 keV gamma-ray interation into the PWO crystal. A micro-channel plate photomultiplier tube (MCP-PMT) encapsulating the PWO crystal amplifies photoelectrons generated at the photocathode, and the corresponding anode signals are collected through the transmission lines read out at both ends and digitized by a SAMPIC module. In this work, we present a realistic Geant4 simulation of the ClearMind prototype detector, including the propagation of the visible photons in the crystal, the modelling of a realistic response of the photocathode and of the PMT, and the propagation of the electrical signals over the transmission lines. The reconstruction of the gamma conversion in the detector volume is performed from the signals registered at both ends of the transmission lines. We compare the reconstruction precision of a statistical algorithm against machine learning algorithms developed using the TMVA package. We expect to reach a spatial resolution down to a few mm$^3$ (FWHM). Finally, we will discuss prospects for the ClearMind detector.
△ Less
Submitted 26 January, 2023; v1 submitted 23 September, 2022;
originally announced September 2022.
-
Performance of CVD diamond detectors for single ion beam-tagging applications in hadrontherapy monitoring
Authors:
Sébastien Curtoni,
Marie-Laure Gallin-Martel,
Sara Marcatili,
Latifa Abbassi,
Alexandre Bes,
Germain Bosson,
Johann Collot,
Thierry Crozes,
Denis Dauvergne,
Wout De Nolf,
Pierre Everaere,
Laurent Gallin-Martel,
Abderrahmane Ghimouz,
Ferid Haddad,
Christophe Hoarau,
Jean-Yves Hostachy,
Charbel Koumeir,
Ana Lacoste,
Vincent Métivier,
John Morse,
Jean-François Motte,
Jean-François Muraz,
Freddy Poirier,
Fatah Ellah Rarbi,
Olivier Rossetto
, et al. (4 additional authors not shown)
Abstract:
In the context of online ion range verification in particle therapy, the CLaRyS collaboration is develo** Prompt-Gamma (PG) detection systems. The originality in the CLaRyS approach is to use a beam-tagging hodoscope in coincidence with the gamma detectors to provide both temporal and spatial information of the incoming ions. The ion range sensitivity of such PG detection systems could be improv…
▽ More
In the context of online ion range verification in particle therapy, the CLaRyS collaboration is develo** Prompt-Gamma (PG) detection systems. The originality in the CLaRyS approach is to use a beam-tagging hodoscope in coincidence with the gamma detectors to provide both temporal and spatial information of the incoming ions. The ion range sensitivity of such PG detection systems could be improved by detecting single ions with a 100 ps ($σ$) time resolution, through a quality assurance procedure at low beam intensity at the beginning of the treatment session. This work presents the investigations led to assess the performance of Chemical Vapor Deposition (CVD) diamond detectors to fulfill these requirements. A $^{90}$Sr beta source, 68 MeV protons, 95 MeV/u carbon ions and a synchrotron X-ray pulsed beam were used to measure the time resolution, single ion detection efficiency and proton counting capability of various CVD diamond samples. An offline technique, based on double-sided readout with fast current preamplifiers and used to improve the signal-to-noise ratio, is also presented. The different tests highlighted Time-Of-Flight resolutions ranging from 13 ps ($σ$) to 250 ps ($σ$), depending on the experimental conditions. The single 68 MeV proton detection efficiency of various large area polycrystalline (pCVD) samples was measured to be $>$96% using coincidence measurements with a single-crystal reference detector. Single-crystal CVD (sCVD) diamond proved to be able to count a discrete number of simultaneous protons while it was not achievable with a polycrystalline sample. Considering the results of the present study, two diamond hodoscope demonstrators are under development: one based on sCVD, and one of larger size based on pCVD. They will be used for the purpose of single ion as well as ion bunches detection, either at reduced or clinical beam intensities.
△ Less
Submitted 23 August, 2021; v1 submitted 11 May, 2021;
originally announced May 2021.
-
RF pulse amplifier for CVD-diamond particle detectors
Authors:
C. Hoarau,
G. Bosson,
J. -L. Bouly,
S. Curtoni,
D. Dauvergne,
P. Everaere,
M. -L. Gallin-Martel,
S. Marcatili,
J. -F. Muraz,
A. Portier,
N. Rosuel
Abstract:
This article introduces a design of a Low Noise Amplifier (LNA), for the field of diamond particle detectors. This amplifier is described from simulation to measurements, which include pulses from α particles detection. In hadron therapy, with high-frequency pulsed particle beams, the diamond detector is a promising candidate for beam monitoring and time-stam**, with prerequisite of fast electro…
▽ More
This article introduces a design of a Low Noise Amplifier (LNA), for the field of diamond particle detectors. This amplifier is described from simulation to measurements, which include pulses from α particles detection. In hadron therapy, with high-frequency pulsed particle beams, the diamond detector is a promising candidate for beam monitoring and time-stam**, with prerequisite of fast electronics. The LNA is designed with surface mounted components and RF layout techniques to control costs and to allow timing performance suitable for sub-nanosecond edges of pulses. Also this amplifier offers the possibility of high voltage biasing, a characteristic essential for driving diamond detectors. Finally the greatest asset of this study is certainly the minimization of the power consumption, which allows us to consider designs with multiple amplifiers, in limited space, for striped diamond detectors.
△ Less
Submitted 22 February, 2021;
originally announced February 2021.
-
Characterization of a beam-tagging hodoscope for hadrontherapy monitoring
Authors:
O. Allegrini,
J. -P. Cachemiche,
C. P. C. Caplan,
B. Carlus,
X. Chen,
S. Curtoni,
D. Dauvergne,
R. Della Negra,
M. -L. Gallin-Martel,
J. Hérault,
J. M. Létang,
C. Morel,
É. Testa,
Y. Zoccarato
Abstract:
A beam tagging hodoscope prototype made of squared 1 mm$^2$ fibers arranged in two perpendicular planes and coupled to multi-anode photomultipliers has been studied using 65 MeV proton as well as 95 MeV/u $^{12}$C beams at various intensities. This hodoscope successfully provided 2D images of proton beams with a detection efficiency larger than 98 % with logical OR condition between the two fiber…
▽ More
A beam tagging hodoscope prototype made of squared 1 mm$^2$ fibers arranged in two perpendicular planes and coupled to multi-anode photomultipliers has been studied using 65 MeV proton as well as 95 MeV/u $^{12}$C beams at various intensities. This hodoscope successfully provided 2D images of proton beams with a detection efficiency larger than 98 % with logical OR condition between the two fiber planes. The detection efficiency with a coincidence between the two planes is close to 75 % for beam intensities up to $\sim1$ MHz. Moreover, the timing resolution is around 1.8 ns FWHM. Overall, the performances show that such a technology is viable for beam monitoring during hadrontherapy.
△ Less
Submitted 6 January, 2021;
originally announced January 2021.
-
A 100 ps TOF Detection System for On-Line Range- Monitoring in Hadrontherapy
Authors:
Sara Marcatili,
Sébastien Curtoni,
Denis Dauvergne,
Ferid Haddad,
Maxime Jacquet,
Charbel Koumeir,
Jean Michel Létang,
Jayde Livingstone,
Vincent Métivier,
Laurent Gallin-Martel,
Marie-Laure Gallin-Martel,
Jean-François Muraz,
Noel Servagent,
Étienne Testa
Abstract:
The accuracy of hadrontherapy treatment is currently limited by ion-range uncertainties. In order to fully exploit the potential of this technique, we propose the development of a novel system for online control of particle therapy, based on TOF-resolved (time-of-flight) Prompt Gamma (PG) imaging with 100 ps time resolution. Our aim is to detect a possible deviation of the proton range with respec…
▽ More
The accuracy of hadrontherapy treatment is currently limited by ion-range uncertainties. In order to fully exploit the potential of this technique, we propose the development of a novel system for online control of particle therapy, based on TOF-resolved (time-of-flight) Prompt Gamma (PG) imaging with 100 ps time resolution. Our aim is to detect a possible deviation of the proton range with respect to treatment planning within the first few irradiation spots at the beginning of the session. The system consists of a diamond-based beam hodoscope for single proton tagging, operated in time coincidence with one or more gamma detectors placed downstream of the patient. The TOF between the proton time of arrival in the hodoscope and the PG detection time provides an indirect measurement of the proton range in the patient with a precision strictly related to the system time resolution. With a single ~38 cm$^{3}$ BaF2 detector placed at 15 cm from a heterogeneous PMMA target, we obtained a coincidence time resolution of 101 ps (rms). This system allowed us to measure the thickness and position of an air cavity within a PMMA target, and the associated proton range shift: a 3 mm shift can be detected at 2$σ$ confidence level within a single large irradiation spot (~10$^{8}$ protons). We are currently conceiving a multi-channel PG timing detector with 3D target coverage. Each pixel will provide the PG detection time and its hit position, that can be used to reconstruct the 3D distribution of PG vertices in the patient. Our approach does not require collimation and allows to dramatically increase the detection efficiency. Since both signal detection and background rejection are based on TOF, the constraints on energy resolution can be relaxed to further improve time resolution.
△ Less
Submitted 20 January, 2020; v1 submitted 13 January, 2020;
originally announced January 2020.
-
Ultra-fast prompt gamma detection in single proton counting regime for range monitoring in particle therapy
Authors:
S. Marcatili,
J. Collot,
S. Curtoni,
D. Dauvergne,
J-Y. Hostachy,
C. Koumeir,
J. M. Létang,
J. Livingstone,
V. Métivier,
L. Gallin-Martel,
M-L. Gallin-Martel,
J. F. Muraz,
N. Servagent,
É. Testa,
M. Yamouni
Abstract:
In order to fully exploit the ballistic potential of particle therapy, we propose an online range monitoring concept based on high-resolution Time-Of-Flight (TOF)-resolved Prompt Gamma (PG) detection in a single proton counting regime. In a proof of principle experiment, different types of monolithic scintillating gamma detectors are read in time coincidence with a diamond-based beam hodoscope, in…
▽ More
In order to fully exploit the ballistic potential of particle therapy, we propose an online range monitoring concept based on high-resolution Time-Of-Flight (TOF)-resolved Prompt Gamma (PG) detection in a single proton counting regime. In a proof of principle experiment, different types of monolithic scintillating gamma detectors are read in time coincidence with a diamond-based beam hodoscope, in order to build TOF spectra of PG generated in a heterogeneous target presenting an air cavity of variable thickness. Since the measurement was carried out at low beam currents ($<$ 1 proton/bunch) it was possible to reach excellent coincidence time resolutions, of the order of 100 ps ($σ$). Our goal is to detect possible deviations of the proton range with respect to treatment planning within a few intense irradiation spots at the beginning of the session and then carry on the treatment at standard beam currents. The measurements were limited to 10 mm proton range shift. A Monte Carlo simulation study reproducing the experiment has shown that a 3 mm shift can be detected at 2$σ$ by a single detector of $\sim 1.4 \times 10^{-3}$ absolute detection efficiency within a single irradiation spot ($\sim$10$^{8}$ protons) and an optimised experimental set-up.
△ Less
Submitted 6 January, 2020;
originally announced January 2020.