-
Development of an integrated device based on the gain/phase detector and Arduino platform for measuring magnetoelastic resonance
Authors:
Wenderson R. F. Silva,
Rafael O. R. R. Cunha,
Joaquim B. S. Mendes
Abstract:
This study presents the development of an integrated device for measuring magnetoelastic resonance, utilizing a gain/phase detector and the Arduino platform. The device stands out for its simplicity, low cost, and efficiency. It employs the Arduino's ATmega328P microcontroller, coupled with the AD8302, and an intuitive graphical interface developed in Python, which facilitates the measurement of m…
▽ More
This study presents the development of an integrated device for measuring magnetoelastic resonance, utilizing a gain/phase detector and the Arduino platform. The device stands out for its simplicity, low cost, and efficiency. It employs the Arduino's ATmega328P microcontroller, coupled with the AD8302, and an intuitive graphical interface developed in Python, which facilitates the measurement of magnetoelastic signals in sensors. The device's validation is carried out through measurements of mass deposits on magnetoelastic sensors, confirming its accuracy and functionality. This advancement offers a practical and portable solution for detecting magnetoelastic resonances, promoting the use of these technologies in field environments and in diverse scientific applications. The integration of components into a compact, robust, and low-cost electronic circuit, along with an easy-to-operate graphical interface, significantly simplifies the complexity of the components, making the equipment complete and readily operational.
△ Less
Submitted 27 June, 2024;
originally announced June 2024.
-
A biosensor based on magnetoelastic waves for detection of antibodies in human plasma for COVID-19 serodiagnosis
Authors:
Wenderson R. F. Silva,
Larissa C. P. Monteiro,
Renato L. Senra,
Eduardo N. D. de Araujo,
Rafael O. R. R. Cunha,
Tiago A. O. Mendes,
Joaquim B. S. Mendes
Abstract:
The study proposes a new efficient wireless biosensor based on magnetoelastic waves for the detection of antibodies in human plasma, aiming at the serological diagnosis of COVID-19. The biosensor was functionalized with the N antigen - nucleocapsid phosphoprotein of the SARS-CoV-2 virus. Validation analyses, by sodium dodecyl-sulfate polyacrylamide gel electrophoresis (SDS-PAGE), Western blotting,…
▽ More
The study proposes a new efficient wireless biosensor based on magnetoelastic waves for the detection of antibodies in human plasma, aiming at the serological diagnosis of COVID-19. The biosensor was functionalized with the N antigen - nucleocapsid phosphoprotein of the SARS-CoV-2 virus. Validation analyses, by sodium dodecyl-sulfate polyacrylamide gel electrophoresis (SDS-PAGE), Western blotting, atomic force microscopy (AFM), scanning electron microscopy (SEM), micro-Raman spectroscopy, confirmed the selectivity and effective surface functionalization of the biosensor. The research successfully obtained, expressed and purified the recombinant antigen, while plasma samples from COVID-19 positive and negative patients were used to test the performance of the biosensor. A comparison of performance with the ELISA method revealed equivalent diagnostic power. These results indicate the robustness of the biosensor in reliably differentiating between positive and negative samples, highlighting its potential as an efficient and low-cost tool for the serological diagnosis of COVID-19. In addition to being fast to execute and having the potential for automation in large-scale diagnostic studies, the biosensor fills a significant gap in existing SARS-CoV-2 detection approaches.
△ Less
Submitted 9 June, 2024; v1 submitted 17 March, 2024;
originally announced March 2024.
-
Outdoor Systems Performace and Upgrade
Authors:
L. Lopes,
S. Andringa,
P. Assis,
A. Blanco,
N. Carolino,
M. A. Cerda,
F. Clemêncio,
R. Conceição,
O. Cunha,
C. Dobrigkeit,
M. Ferreira,
C. Loureiro,
L. Mendes,
J. C. Nogueira,
A. Pereira,
M. Pimenta,
J. Saraiva,
R. Sarmento,
P. Teixeira,
B. Tomé
Abstract:
Over the last two decades, the possibility of using RPCs in outdoors systems has increased considerably. Our group has participated in this effort having installed several systems and continues to work on their optimization, while simultaneously studying and develo** new approaches that can to use of RPCs in outdoor applications.
In particular, some detectors were deployed in the field at the…
▽ More
Over the last two decades, the possibility of using RPCs in outdoors systems has increased considerably. Our group has participated in this effort having installed several systems and continues to work on their optimization, while simultaneously studying and develo** new approaches that can to use of RPCs in outdoor applications.
In particular, some detectors were deployed in the field at the Pierre Auger Observatory in 2019 remained inactive, awaiting the commissioning of support systems. During the pandemic the detectors were left without gas flow for more than two years, but were recently reactivated with no major problems.
The LouMu project combines particle physics and geophysics in order to map large geologic structures, using Muon Tomography. The development of the RPC system used and the data from the last two years will be presented.
Finally, recent advances in a large area (1 m2) double gap-sealed RPC will be presented.
△ Less
Submitted 9 December, 2022;
originally announced December 2022.
-
An RPC-PET brain scanner demonstrator: first results
Authors:
Paulo Fonte,
Luís Lopes,
Rui Alves,
Nuno Carolino,
Paulo Crespo,
Miguel Couceiro,
Orlando Cunha,
Nuno Dias,
Nuno C. Ferreira,
Susete Fetal,
Ana L. Lopes,
Jan Michel,
Jorge Moreira,
Américo Pereira,
João Saraiva,
Carlos Silva,
Magda Silva,
Michael Traxler,
Antero Abrunhosa,
Alberto Blanco,
Miguel Castelo-Branco,
Mário Pimenta
Abstract:
We present first results from a Positron Emission Tomography (PET) scanner demonstrator based on Resistive Plate Chambers and specialized for brain imaging. The device features a 30 cm wide cubic field-of-view and each detector comprises 40 gas gaps with 3D location of the interaction point of the photon. Besides other imagery, we show that the reconstructed image resolution, as evaluated by a hot…
▽ More
We present first results from a Positron Emission Tomography (PET) scanner demonstrator based on Resistive Plate Chambers and specialized for brain imaging. The device features a 30 cm wide cubic field-of-view and each detector comprises 40 gas gaps with 3D location of the interaction point of the photon. Besides other imagery, we show that the reconstructed image resolution, as evaluated by a hot-rod phantom, is sub-millimetric, which is beyond the state-of-the-art of the standard PET technology for this application.
△ Less
Submitted 10 November, 2022;
originally announced November 2022.
-
Prototype of an affordable pressure-controlled emergency mechanical ventilator for COVID-19
Authors:
Américo Pereira,
Luís Lopes,
Paulo Fonte,
Pedro Póvoa,
Telmo G. Santos,
Alberto Martinho,
Ângela Neves,
António Bugalho,
António Gabriel-Santos,
Gonçalo Gaspar Bentes Pimenta,
João Goês,
João Martins,
João Pedro Oliveira,
José Paulo Santos,
Luís C. Gil,
Miguel Onofre Domingues,
Orlando Cunha,
Pedro Pinheiro de Sousa,
Tiago A. Rodrigues,
Valdemar R. Duarte,
Antero Abrunhosa,
António Grilo,
João Agostinho do Nascimento,
Mário Pimenta
Abstract:
We present a viable prototype of a simple mechanical ventilator intended as a last resort to ventilate COVID-19 patients. The prototype implements the pressure-controlled continuous mandatory ventilation mode (PC-CMV) with settable breathing rates, inspiration/expiration time ratios and FiO2 modulation. Although safe, the design aims to minimize the use of technical components and those used are c…
▽ More
We present a viable prototype of a simple mechanical ventilator intended as a last resort to ventilate COVID-19 patients. The prototype implements the pressure-controlled continuous mandatory ventilation mode (PC-CMV) with settable breathing rates, inspiration/expiration time ratios and FiO2 modulation. Although safe, the design aims to minimize the use of technical components and those used are common in industry, so its construction may be possible in times of logistical shortage or disruption or in areas with reduced access to technical materials and at a moderate cost, affordable to lower income countries. Most of the device can be manufactured by modest technical means and construction plans are provided.
△ Less
Submitted 21 July, 2020; v1 submitted 1 April, 2020;
originally announced April 2020.
-
MARTA: A high-energy cosmic-ray detector concept with high-accuracy muon measurement
Authors:
P. Abreu,
S. Andringa,
P. Assis,
A. Blanco,
V. Barbosa Martins,
P. Brogueira,
N. Carolino,
L. Cazon,
M. Cerda,
G. Cernicchiaro,
R. Colalillo,
R. Conceição,
O. Cunha,
R. M. de Almeida,
V. de Souza,
F. Diogo,
C. Dobrigkeit,
J. Espadanal,
C. Espirito-Santo,
M. Ferreira,
P. Ferreira,
P. Fonte,
U. Giaccari,
P. Gonçalves,
F. Guarino
, et al. (20 additional authors not shown)
Abstract:
A new concept for the direct measurement of muons in air showers is presented. The concept is based on resistive plate chambers (RPCs), which can directly measure muons with very good space and time resolution. The muon detector is shielded by placing it under another detector able to absorb and measure the electromagnetic component of the showers such as a water-Cherenkov detector, commonly used…
▽ More
A new concept for the direct measurement of muons in air showers is presented. The concept is based on resistive plate chambers (RPCs), which can directly measure muons with very good space and time resolution. The muon detector is shielded by placing it under another detector able to absorb and measure the electromagnetic component of the showers such as a water-Cherenkov detector, commonly used in air shower arrays. The combination of the two detectors in a single, compact detector unit provides a unique measurement that opens rich possibilities in the study of air showers.
△ Less
Submitted 20 April, 2018; v1 submitted 20 December, 2017;
originally announced December 2017.
-
Autonomous RPCs for a Cosmic Ray ground array
Authors:
Pedro Assis,
Alberto Blanco,
Nuno Carolino,
Ruben Conceição,
Orlando Cunha,
Carola Dobrigkeit,
Miguel Ferreira,
Paulo Fonte,
Luis Lopes,
Ricardo Luz,
Victor Barbosa Martins,
Luis Mendes,
Américo Pereira,
Mário Pimenta,
Raul Sarmento,
Ronald Shellard,
Vitor de Souza,
Bernardo Tomé
Abstract:
We report on the behaviour of Resistive Plate Chambers (RPC) developed for muon detection in ultra-high energy cosmic ray (UHECR) experiments. The RPCs were developed for the MARTA project and were tested on field conditions. These RPCs cover an area of $1.5 \times 1.2\,{m^2}$ and are instrumented with 64 pickup electrodes providing a segmentation better than $20\,$cm. By shielding the detector un…
▽ More
We report on the behaviour of Resistive Plate Chambers (RPC) developed for muon detection in ultra-high energy cosmic ray (UHECR) experiments. The RPCs were developed for the MARTA project and were tested on field conditions. These RPCs cover an area of $1.5 \times 1.2\,{m^2}$ and are instrumented with 64 pickup electrodes providing a segmentation better than $20\,$cm. By shielding the detector units with enough slant mass to absorb the electromagnetic component in the air showers, a clean measurement of the muon content is allowed, a concept to be implemented in a next generation of UHECR experiments. The operation of a ground array detector poses challenging demands, as the RPC must operate remotely under extreme environmental conditions, with limited budgets for power and minimal maintenance. The RPC, DAQ, High Voltage and monitoring systems are enclosed in an aluminium-sealed case, providing a compact and robust unit suited for outdoor environments, which can be easily deployed and connected. The RPCs developed at LIP-Coimbra are able to operate using a very low gas flux, which allows running them for few years with a small gas reservoir. Several prototypes have already been built and tested both in the laboratory and outdoors. We report on the most recent tests done in the field that show that the developed RPCs have operated in a stable way for more than 2 years in field conditions.
△ Less
Submitted 27 September, 2017;
originally announced September 2017.
-
Outdoor Field Experience with Autonomous RPC Based Stations
Authors:
L. Lopes,
P. Assis,
A. Blanco,
N. Carolino,
M. A. Cerda,
R. Conceição,
O. Cunha,
M. Ferreira,
P. Fonte,
R. Luz,
L. Mendes,
A. Pereira,
M. Pimenta,
R. Sarmento,
B. Tomé
Abstract:
In the last two decades Resistive Plate Chambers were employed in the Cosmic Ray Experiments COVER-PLASTEX and ARGO/YBJ. In both experiments the detectors were housed indoors, likely owing to gas distribution requirements and the need to control environment variables that directly affect RPCs operational stability. But in experiments where Extended Air Shower (EAS) sampling is necessary, large are…
▽ More
In the last two decades Resistive Plate Chambers were employed in the Cosmic Ray Experiments COVER-PLASTEX and ARGO/YBJ. In both experiments the detectors were housed indoors, likely owing to gas distribution requirements and the need to control environment variables that directly affect RPCs operational stability. But in experiments where Extended Air Shower (EAS) sampling is necessary, large area arrays composed by dispersed stations are deployed, rendering this kind of approach impossible. In this situation, it would be mandatory to have detectors that could be deployed in small standalone stations, with very rare opportunities for maintenance, and with good resilience to environmental conditions. Aiming to meet these requirements, we started some years ago the development of RPCs for Autonomous Stations. The results from indoor tests and measurements were very promising, both concerning performance and stability under very low gas flow rate, which is the main requirement for Autonomous Stations. In this work we update the indoor results and show the first ones concerning outdoor stable operation. In particular, a dynamic adjustment of the high voltage is applied to keep gas gain constant.
△ Less
Submitted 30 August, 2016; v1 submitted 10 June, 2016;
originally announced June 2016.