Correcting directional dark-field x-ray imaging artefacts using position-dependent image deblurring and attenuation removal
Authors:
Michelle K Croughan,
David M Paganin,
Samantha J Alloo,
Jannis N Ahlers,
Ying Ying How,
Stephanie A Harker,
Kaye S. Morgan
Abstract:
In recent years, a novel x-ray imaging modality has emerged that reveals unresolved sample microstructure via a "dark-field image", which provides complementary information to conventional "bright-field" images, such as attenuation and phase-contrast modalities. This x-ray dark-field signal is produced by unresolved microstructures scattering the x-ray beam resulting in localised image blur. Dark-…
▽ More
In recent years, a novel x-ray imaging modality has emerged that reveals unresolved sample microstructure via a "dark-field image", which provides complementary information to conventional "bright-field" images, such as attenuation and phase-contrast modalities. This x-ray dark-field signal is produced by unresolved microstructures scattering the x-ray beam resulting in localised image blur. Dark-field retrieval techniques extract this blur to reconstruct a dark-field image. Unfortunately, the presence of non-dark-field blur such as source-size blur or the detector point-spread-function can affect the dark-field retrieval as they also blur the experimental image. In addition, dark-field images can be degraded by the artefacts induced by large intensity gradients from attenuation and propagation-based phase contrast, particularly around sample edges. By measuring any non-dark-field blurring across the image plane and removing it from experimental images, as well as removing attenuation and propagation-based phase contrast, we show that a directional dark-field image can be retrieved with fewer artefacts and more consistent quantitative measures. We present the details of these corrections and provide "before and after" directional dark-field images of samples imaged at a synchrotron source. This paper utilises single-grid directional dark-field imaging, but these corrections have the potential to be broadly applied to other x-ray imaging techniques.
△ Less
Submitted 6 May, 2024; v1 submitted 26 April, 2024;
originally announced April 2024.
-
Directional dark-field retrieval with single-grid x-ray imaging
Authors:
Michelle K Croughan,
Ying Ying How,
Allan Pennings,
Kaye S Morgan
Abstract:
Directional dark-field imaging is an emerging x-ray modality that is sensitive to unresolved anisotropic scattering from sub-pixel sample microstructures. A single-grid imaging set-up can be used to capture dark-field images by looking at changes in a grid pattern projected upon the sample. By creating analytical models for the experiment, we have developed a single-grid directional dark field ret…
▽ More
Directional dark-field imaging is an emerging x-ray modality that is sensitive to unresolved anisotropic scattering from sub-pixel sample microstructures. A single-grid imaging set-up can be used to capture dark-field images by looking at changes in a grid pattern projected upon the sample. By creating analytical models for the experiment, we have developed a single-grid directional dark field retrieval algorithm that can extract dark-field parameters such as the dominant scattering direction, and the semi-major and -minor scattering angles. We show that this method is effective even in the presence of high image noise, allowing for low dose and time sequence imaging.
△ Less
Submitted 6 April, 2023; v1 submitted 20 November, 2022;
originally announced November 2022.
-
Fast implicit diffusive dark-field retrieval for single-exposure, single-mask x-ray imaging
Authors:
Mario A. Beltran,
David M. Paganin,
Michelle K. Croughan,
Kaye S. Morgan
Abstract:
Complementary to conventional and phase X-ray radiography, dark-field imaging has become central in visualizing diffusive scattering signal due to the spatially-unresolved texture within an object. To date most diffusive-dark-field retrieval methods require either the acquisition of multiple images at the cost of higher radiation dose or significant amounts of computational memory and time. In thi…
▽ More
Complementary to conventional and phase X-ray radiography, dark-field imaging has become central in visualizing diffusive scattering signal due to the spatially-unresolved texture within an object. To date most diffusive-dark-field retrieval methods require either the acquisition of multiple images at the cost of higher radiation dose or significant amounts of computational memory and time. In this work, a simple method of X-ray diffusive dark-field retrieval is presented, applicable to any single-mask imaging setup, with only one exposure of the sample. The approach, which is based on a model of geometric and diffusive reverse-flow conservation, is implicit and non-iterative. This numerically fast methodology is applied to experimental X-ray images acquired using both a random mask and a grid mask, giving high quality reconstructions that are very stable in the presence of noise. The method should be useful for high-speed imaging and/or imaging with low-flux sources.
△ Less
Submitted 17 March, 2023; v1 submitted 11 November, 2022;
originally announced November 2022.
-
Accurate measures of regional lung air volumes from chest X-rays of small animals
Authors:
D. W. O'Connell,
K. S. Morgan,
G. Ruben,
L. C. P. Croton,
J. A. Pollock,
M. K. Croughan,
E. V. McGillick,
M. J. Wallace,
K. J. Crossley,
E. J. Pryor,
R. A. Lewis,
S. B. Hooper,
M. J. Kitchen
Abstract:
We present a robust technique for calculating regional volume changes within the lung from X-ray radiograph sequences captured during ventilation, without the use of computed tomography (CT). This technique is based on the change in transmitted X-ray intensity that occurs for each lung region as air displaces the attenuating lung tissue. Lung air volumes calculated from X-ray intensity changes sho…
▽ More
We present a robust technique for calculating regional volume changes within the lung from X-ray radiograph sequences captured during ventilation, without the use of computed tomography (CT). This technique is based on the change in transmitted X-ray intensity that occurs for each lung region as air displaces the attenuating lung tissue. Lung air volumes calculated from X-ray intensity changes showed a strong correlation ($R^2$=0.98) against the true volumes, measured from high-resolution CT. This correlation enables us to accurately convert projected intensity data into relative changes in lung air volume. We have applied this technique to measure changes in regional lung volumes from X-ray image sequences of mechanically ventilated, recently-deceased newborn rabbits, without the use of CT. This method is suitable for biomedical research studies and shows potential for clinical application.
△ Less
Submitted 7 April, 2022; v1 submitted 16 February, 2022;
originally announced February 2022.
-
Precise phase retrieval for propagation-based images using discrete mathematics
Authors:
J. A. Pollock,
K. S. Morgan,
L. C. P. Croton,
M. K. Croughan,
G. Ruben,
N. Yagi,
H. Sekiguchi,
M. J. Kitchen
Abstract:
The ill-posed problem of phase retrieval in optics, using one or more intensity measurements, has a multitude of applications using electromagnetic or matter waves. Many phase retrieval algorithms are computed on pixel arrays using discrete Fourier transforms due to their high computational efficiency. However, the mathematics underpinning these algorithms is typically formulated using continuous…
▽ More
The ill-posed problem of phase retrieval in optics, using one or more intensity measurements, has a multitude of applications using electromagnetic or matter waves. Many phase retrieval algorithms are computed on pixel arrays using discrete Fourier transforms due to their high computational efficiency. However, the mathematics underpinning these algorithms is typically formulated using continuous mathematics, which can result in a loss in spatial resolution in the reconstructed images. Herein we investigate how phase retrieval algorithms for propagation-based phase-contrast X-ray imaging can be rederived using discrete mathematics and result in more precise retrieval for single- and multi-material objects and for spectral image decomposition. We validate this theory through experimental measurements of spatial resolution using computed tomography (CT) reconstructions of plastic phantoms and biological tissue, using detectors with a range of imaging system point spread functions (PSFs). We demonstrate that if the PSF substantially suppresses high spatial frequencies, the potential improvement from utilising the discrete derivation is limited. However, with detectors characterised by a single pixel PSF (e.g. direct, photon-counting X-ray detectors), a significant improvement in spatial resolution can be obtained, demonstrated here at up to 17%.
△ Less
Submitted 20 September, 2022; v1 submitted 14 June, 2021;
originally announced June 2021.