Thermal Characterization of Tl$_2$LiYCl$_6$:Ce (TLYC)
Authors:
M. M. Watts,
K. E. Mesick,
K. D. Bartlett,
D. D. S. Coupland
Abstract:
Tl$_2$LiYCl$_6$:Ce (TLYC) is a new dual-detection elpasolite scintillator that can detect and distinguish between gamma rays and neutrons using pulse-shape discrimination (PSD). It has a higher density and Z-number than the more mature and well-known elpasolite Cs$_2$LiYCl$_6$:Ce (CLYC), causing it to have a significantly better gamma-ray stop** power. These properties make TLYC an attractive al…
▽ More
Tl$_2$LiYCl$_6$:Ce (TLYC) is a new dual-detection elpasolite scintillator that can detect and distinguish between gamma rays and neutrons using pulse-shape discrimination (PSD). It has a higher density and Z-number than the more mature and well-known elpasolite Cs$_2$LiYCl$_6$:Ce (CLYC), causing it to have a significantly better gamma-ray stop** power. These properties make TLYC an attractive alternative to CLYC for resource-constrained applications where size and weight are important, such as space or national security applications. Such applications may be subjected to a wide range of temperatures, and therefore TLYC's performance was characterized for the first time over a temperature range of -20$^{\circ}$C to +50$^{\circ}$C in 10$^{\circ}$C increments. TLYC's thermal response effects on light-output linearity with energy, gamma-ray photopeak energy resolution, detected neutron energy, pulse shapes, and figure of merit is analyzed and reported. The light output of TLYC was found to be linear with energy over the tested temperature range and was observed to decrease with increasing temperature. The decay time of the scintillation light output was observed to decrease with decreasing temperature at short times, leading to a decreasing PSD figure of merit. The gamma-ray photopeak energy resolution was also observed to degrade with decreasing temperature, due to an asymmetric broadening of the photopeak at low temperatures.
△ Less
Submitted 24 December, 2019;
originally announced December 2019.
-
Proton Irradiation Damage and Annealing Effects in ON Semiconductor J-Series Silicon Photomultipliers
Authors:
K. D. Bartlett,
D. D. S. Coupland,
D. Beckman,
K. E. Mesick
Abstract:
Silicon photomultipliers (SiPMs) have become popular light conversion devices in recent years due to their low bias voltage and sensitivity to wavelengths emitted from common scintillating materials. These properties make them particularly attractive for resource-constrained missions such as space-based detector applications. However the space radiation environment is known to be particularly hars…
▽ More
Silicon photomultipliers (SiPMs) have become popular light conversion devices in recent years due to their low bias voltage and sensitivity to wavelengths emitted from common scintillating materials. These properties make them particularly attractive for resource-constrained missions such as space-based detector applications. However the space radiation environment is known to be particularly harsh on semiconductor devices, where high particle fluences can degrade performance over time. The radiation hardness of a particular SiPM, manufactured by ON Semiconductor (formally SensL), has yet to be studied with high energy protons, which are native to the space radiation environment. To study these effects we have irradiated groups of two SiPMs to four different fluences of 800 MeV protons delivered by the accelerator at the Los Alamos Neutron Science Center. Fluences of $1.68\times10^{9}$, $1.73\times10^{10}$, $6.91\times10^{10}$, and $1.73\times10^{11}$ protons cm$^{-2}$, and their corresponding estimated doses of $0.15$, $1.55$, $6.19$, and $15.5$ kRad, were chosen based on estimates of the potential exposure a SiPM might receive during an interplanetary space mission lasting 10 years. We report the effects these doses have on dark current and the self-annealing time.
△ Less
Submitted 19 November, 2019;
originally announced November 2019.
-
Effects of Proton-Induced Radiation Damage on CLYC and CLLBC Performance
Authors:
K. E. Mesick,
K. D. Bartlett,
D. D. S. Coupland,
L. C. Stonehill
Abstract:
Cerium-doped Cs$_2$LiYCl$_6$ (CLYC) and Cs$_2$LiLaBr$_x$Cl$_{6-x}$ (CLLBC) are scintillators in the elpasolite family that are attractive options for resource-constrained applications due to their ability to detect both gamma rays and neutrons within a single volume. Space-based detectors are one such application, however, the radiation environment in space can over time damage the crystal structu…
▽ More
Cerium-doped Cs$_2$LiYCl$_6$ (CLYC) and Cs$_2$LiLaBr$_x$Cl$_{6-x}$ (CLLBC) are scintillators in the elpasolite family that are attractive options for resource-constrained applications due to their ability to detect both gamma rays and neutrons within a single volume. Space-based detectors are one such application, however, the radiation environment in space can over time damage the crystal structure of the elpasolites, leading to degraded performance. We have exposed 4 samples each of CLYC and CLLBC to 800 MeV protons at the Los Alamos Neutron Science Center. The samples were irradiated with a total number of protons of 1.3$\times$10$^{9}$, 1.3$\times$10$^{10}$, 5.2$\times$10$^{10}$, and 1.3$\times$10$^{11}$, corresponding to estimated doses of 0.14, 1.46, 5.82, and 14.6 kRad, respectively on the CLYC samples and 0.14, 1.38, 5.52, and 13.8 kRad, respectively on the CLLBC samples. We report the impact these radiation doses have on the light output, activation, gamma-ray energy resolution, pulse shapes, and pulse-shape discrimination figure of merit for CLYC and CLLBC.
△ Less
Submitted 17 July, 2019;
originally announced July 2019.
-
Elpasolite Planetary Ice and Composition Spectrometer (EPICS): A Low-Resource Combined Gamma-Ray and Neutron Spectrometer for Planetary Science
Authors:
K. E. Mesick,
L. C. Stonehill,
D. D. S Coupland,
D. T. Beckman,
S. T. West,
S. F. Nowicki,
N. A. Dallmann,
S. A. Storms,
W. C. Feldman
Abstract:
Neutron and gamma-ray spectroscopy (NGRS) is a well established technique for studying the geochemical composition and volatile abundance relevant to planetary structure and evolution of planetary bodies. Previous NGRS instruments have used separate gamma-ray and neutron spectrometers. The Elpasolite Planetary Ice and Composition Spectrometer (EPICS) instrument is an innovative and fully integrate…
▽ More
Neutron and gamma-ray spectroscopy (NGRS) is a well established technique for studying the geochemical composition and volatile abundance relevant to planetary structure and evolution of planetary bodies. Previous NGRS instruments have used separate gamma-ray and neutron spectrometers. The Elpasolite Planetary Ice and Composition Spectrometer (EPICS) instrument is an innovative and fully integrated NGRS with low resource requirements. EPICS utilizes elpasolite scintillator read out by silicon photomultipliers to combine the gamma-ray and neutron spectrometer into a single instrument, leading to a significant reduction in instrument size, weight, and power. An overview and motivation for the EPICS instrument, current status of the EPICS development, and a discussion of the expected sensitivity and performance are presented.
△ Less
Submitted 9 January, 2019;
originally announced January 2019.
-
The Effects of Radiation Damage on CLYC Performance
Authors:
K. E. Mesick,
D. D. S. Coupland,
S. F. Nowicki,
L. C. Stonehill
Abstract:
Cs$_2$LiYCl$_6$:Ce$^{3+}$ (CLYC) is a new scintillator that is an attractive option for applications requiring the ability to detect both gamma rays and neutrons within a single volume. It is therefore of interest in applications that require low size, weight, or power, such as space applications. The radiation environment in space can over time damage the crystal structure of CLYC, leading to red…
▽ More
Cs$_2$LiYCl$_6$:Ce$^{3+}$ (CLYC) is a new scintillator that is an attractive option for applications requiring the ability to detect both gamma rays and neutrons within a single volume. It is therefore of interest in applications that require low size, weight, or power, such as space applications. The radiation environment in space can over time damage the crystal structure of CLYC, leading to reduced performance. We have exposed 2 CLYC samples to 800 MeV protons at the Los Alamos Neutron Science Center, one to approximately 10 kRad and one to approximately 100 kRad. We measured the pulse shapes and amplitudes, energy resolution, and figure of merit for pulse-shape discrimination before and after irradiation. We have also measured the activation products and monitored for room-temperature annealing of the irradiated samples. The results of these measurements and the impact of radiation damage on CLYC performance is presented.
△ Less
Submitted 15 October, 2018; v1 submitted 29 November, 2017;
originally announced November 2017.
-
Pulse-shape discrimination and energy quenching of alpha particles in Cs$_2$LiLaBr$_6$:Ce$^{3+}$
Authors:
Katherine E. Mesick,
Daniel D. S. Coupland,
Laura C. Stonehill
Abstract:
Cs$_2$LiLaBr$_6$:Ce$^{3+}$ (CLLB) is an elpasolite scintillator that offers excellent linearity and gamma-ray energy resolution and sensitivity to thermal neutrons with the ability to perform pulse-shape discrimination (PSD) to distinguish gammas and neutrons. Our investigation of CLLB has indicated the presence of intrinsic radioactive alpha background that we have determined to be from actinium…
▽ More
Cs$_2$LiLaBr$_6$:Ce$^{3+}$ (CLLB) is an elpasolite scintillator that offers excellent linearity and gamma-ray energy resolution and sensitivity to thermal neutrons with the ability to perform pulse-shape discrimination (PSD) to distinguish gammas and neutrons. Our investigation of CLLB has indicated the presence of intrinsic radioactive alpha background that we have determined to be from actinium contamination of the lanthanum component. We measured the pulse shapes for gamma, thermal neutron, and alpha events and determined that PSD can be performed to separate the alpha background with a moderate figure of merit of 0.98. We also measured the electron-equivalent-energy of the alpha particles in CLLB and simulated the intrinsic alpha background from $^{227}$Ac to determine the quenching factor of the alphas. A linear quenching relationship $L_α = E_α \times q + L_0$ was found at alpha particle energies above 5 MeV, with a quenching factor $q = 0.71$ MeVee/MeV and an offset $L_0 = - 1.19$ MeVee.
△ Less
Submitted 27 September, 2016;
originally announced September 2016.
-
Performance of Several Solid State Photomultipliers with CLYC Scintillator
Authors:
Katherine E. Mesick,
Laura C. Stonehill,
Jonathan T. Morrell,
Daniel D. S. Coupland
Abstract:
$Cs_2LiYCl_6:Ce^{3+}…
▽ More
$Cs_2LiYCl_6:Ce^{3+}$ (CLYC) is an inorganic scintillator that has recently garnered attention for its ability to detect and discriminate between gammas and thermal neutrons. We investigate several important performance parameters of three different solid state photomultipliers (SSPMs) when reading out CLYC crystals: linearity, energy resolution, and pulse shape and discrimination ability. These performance parameters are assessed at a variety of temperatures between -20$^{\circ}$C and +50$^{\circ}$C.
△ Less
Submitted 3 December, 2015;
originally announced December 2015.
-
Tracking rare-isotope beams with microchannel plates
Authors:
A. M. Rogers,
A. Sanetullaev,
W. G. Lynch,
M. B. Tsang,
J. Lee,
D. Bazin,
D. Coupland,
V. Henzl,
D. Henzlova,
M. Kilburn,
M. S. Wallace,
M. Youngs,
F. Delaunay,
M. Famiano,
D. Shapira,
K. L. Jones,
K. T. Schmitt,
Z. Y. Sun
Abstract:
A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current design is an adaptation of an assembly used for low-energy beams ($\sim$1.4 MeV/nucleon). In order to improve resolution in tracking high-energy heavy-ion beams,…
▽ More
A system of two microchannel-plate detectors has been successfully implemented for tracking projectile-fragmentation beams. The detectors provide interaction positions, angles, and arrival times of ions at the reaction target. The current design is an adaptation of an assembly used for low-energy beams ($\sim$1.4 MeV/nucleon). In order to improve resolution in tracking high-energy heavy-ion beams, the magnetic field strength between the secondary-electron accelerating foil and the microchannel plate had to be increased substantially. Results from an experiment using a 37-MeV/nucleon ${}^{56}$Ni beam show that the tracking system can achieve sub-nanosecond timing resolution and a position resolution of $\sim$1 mm for beam intensities up to $5\times10^{5}$ pps.
△ Less
Submitted 11 September, 2013;
originally announced September 2013.