The Future Of The Arecibo Observatory: The Next Generation Arecibo Telescope
Authors:
D. Anish Roshi,
N. Aponte,
E. Araya,
H. Arce,
L. A. Baker,
W. Baan,
T. M. Becker,
J. K. Breakall,
R. G. Brown,
C. G. M. Brum,
M. Busch,
D. B. Campbell,
T. Cohen,
F. Cordova,
J. S. Deneva,
M. Devogele,
T. Dolch,
F. O. Fernandez-Rodriguez,
T. Ghosh,
P. F. Goldsmith,
L. I. Gurvits,
M. Haynes,
C. Heiles,
J. W. T. Hessel,
D. Hickson
, et al. (49 additional authors not shown)
Abstract:
The Arecibo Observatory (AO) is a multidisciplinary research and education facility that is recognized worldwide as a leading facility in astronomy, planetary, and atmospheric and space sciences. AO's cornerstone research instrument was the 305-m William E. Gordon telescope. On December 1, 2020, the 305-m telescope collapsed and was irreparably damaged. In the three weeks following the collapse, A…
▽ More
The Arecibo Observatory (AO) is a multidisciplinary research and education facility that is recognized worldwide as a leading facility in astronomy, planetary, and atmospheric and space sciences. AO's cornerstone research instrument was the 305-m William E. Gordon telescope. On December 1, 2020, the 305-m telescope collapsed and was irreparably damaged. In the three weeks following the collapse, AO's scientific and engineering staff and the AO users community initiated extensive discussions on the future of the observatory. The community is in overwhelming agreement that there is a need to build an enhanced, next-generation radar-radio telescope at the AO site. From these discussions, we established the set of science requirements the new facility should enable. These requirements can be summarized briefly as: 5 MW of continuous wave transmitter power at 2 - 6 GHz, 10 MW of peak transmitter power at 430 MHz (also at 220MHz under consideration), zenith angle coverage 0 to 48 deg, frequency coverage 0.2 to 30 GHz and increased Field-of-View. These requirements determine the unique specifications of the proposed new instrument. The telescope design concept we suggest consists of a compact array of fixed dishes on a tiltable, plate-like structure with a collecting area equivalent to a 300m dish. This concept, referred to as the Next Generation Arecibo Telescope (NGAT), meets all of the desired specifications and provides significant new science capabilities to all three research groups at AO. This whitepaper presents a sample of the wide variety of the science that can be achieved with the NGAT, the details of the telescope design concept and the need for the new telescope to be located at the AO site. We also discuss other AO science activities that interlock with the NGAT in the white paper.
△ Less
Submitted 1 April, 2021; v1 submitted 1 March, 2021;
originally announced March 2021.
Conduction mechanism and switchable photovoltaic effect in (111) oriented BiFe$_{0.95}$Mn$_{0.05}$O$_{3}$ thin film
Authors:
Jamal Belhadi,
J. Ruvalcaba,
S. Yousfi,
M. El-Marssi,
T. Fraga Córdova,
S. Matzen,
P. Lecoeur,
H. Bouyanfif
Abstract:
Epitaxial 200nm BiFe$_{0.95}$Mn$_{0.05}$O$_{3}$ (BFO) film was grown by pulsed laser deposition on (111) oriented SrTiO3 substrate buffered with a 50nm thick SrRuO$_{3}$ electrode. The BFO thin film shows a rhombohedral structure and a large remnant polarization of Pr = 104 $μ$C/cm$^{2}$. By comparing I(V) characteristics with different conduction models we reveal the presence of both bulk limited…
▽ More
Epitaxial 200nm BiFe$_{0.95}$Mn$_{0.05}$O$_{3}$ (BFO) film was grown by pulsed laser deposition on (111) oriented SrTiO3 substrate buffered with a 50nm thick SrRuO$_{3}$ electrode. The BFO thin film shows a rhombohedral structure and a large remnant polarization of Pr = 104 $μ$C/cm$^{2}$. By comparing I(V) characteristics with different conduction models we reveal the presence of both bulk limited Poole-Frenkel and Schottky interface mechanisms and each one dominates in a specific range of temperature. At room temperature and under 10mW laser illumination, the as grown BFO film presents short-circuit current density (Jsc) and open circuit voltage (Voc) of 2.25mA/cm$^{2}$ and -0.55V respectively. This PV effect can be switched by applying positive voltage pulses higher than the coercive field. For low temperatures a large Voc value of about -4.5V (-225kV/cm) is observed which suggests a bulk non-centrosymmetric origin of the PV response.
△ Less
Submitted 4 May, 2019;
originally announced May 2019.