-
Diffusion Prior Regularized Iterative Reconstruction for Low-dose CT
Authors:
Wenjun Xia,
Yongyi Shi,
Chuang Niu,
Wenxiang Cong,
Ge Wang
Abstract:
Computed tomography (CT) involves a patient's exposure to ionizing radiation. To reduce the radiation dose, we can either lower the X-ray photon count or down-sample projection views. However, either of the ways often compromises image quality. To address this challenge, here we introduce an iterative reconstruction algorithm regularized by a diffusion prior. Drawing on the exceptional imaging pro…
▽ More
Computed tomography (CT) involves a patient's exposure to ionizing radiation. To reduce the radiation dose, we can either lower the X-ray photon count or down-sample projection views. However, either of the ways often compromises image quality. To address this challenge, here we introduce an iterative reconstruction algorithm regularized by a diffusion prior. Drawing on the exceptional imaging prowess of the denoising diffusion probabilistic model (DDPM), we merge it with a reconstruction procedure that prioritizes data fidelity. This fusion capitalizes on the merits of both techniques, delivering exceptional reconstruction results in an unsupervised framework. To further enhance the efficiency of the reconstruction process, we incorporate the Nesterov momentum acceleration technique. This enhancement facilitates superior diffusion sampling in fewer steps. As demonstrated in our experiments, our method offers a potential pathway to high-definition CT image reconstruction with minimized radiation.
△ Less
Submitted 10 October, 2023;
originally announced October 2023.
-
Image Reconstruction Using a Mixture Score Function (MSF)
Authors:
Wenxiang Cong,
Wenjun Xia,
Ge Wang
Abstract:
Computed tomography (CT) reconstructs volumetric images using X-ray projection data acquired from multiple angles around an object. For low-dose or sparse-view CT scans, the classic image reconstruction algorithms often produce severe noise and artifacts. To address this issue, we develop a novel iterative image reconstruction method based on maximum a posteriori (MAP) estimation. In the MAP frame…
▽ More
Computed tomography (CT) reconstructs volumetric images using X-ray projection data acquired from multiple angles around an object. For low-dose or sparse-view CT scans, the classic image reconstruction algorithms often produce severe noise and artifacts. To address this issue, we develop a novel iterative image reconstruction method based on maximum a posteriori (MAP) estimation. In the MAP framework, the score function, i.e., the gradient of the logarithmic probability density distribution, plays a crucial role as an image prior in the iterative image reconstruction process. By leveraging the Gaussian mixture model, we derive a novel score matching formula to establish an advanced score function (ADSF) through deep learning. Integrating the new ADSF into the image reconstruction process, a new ADSF iterative reconstruction method is developed to improve image reconstruction quality. The convergence of the ADSF iterative reconstruction algorithm is proven through mathematical analysis. The performance of the ADSF reconstruction method is also evaluated on both public medical image datasets and clinical raw CT datasets. Our results show that the ADSF reconstruction method can achieve better denoising and deblurring effects than the state-of-the-art reconstruction methods, showing excellent generalizability and stability.
△ Less
Submitted 29 February, 2024; v1 submitted 14 June, 2023;
originally announced June 2023.
-
Fluorescence Molecular Tomography for Quantum Yield and Lifetime
Authors:
Wenxiang Cong,
Ge Wang
Abstract:
Fluorescence molecular tomography (FMT) is a promising modality for non-invasive imaging of internal fluorescence agents in biological tissues especially in small animal models, with applications in diagnosis, therapy, and drug design. In this paper, we present a new fluorescent reconstruction algorithm that combines time-resolved fluorescence imaging data with photon-counting micro-CT (PCMCT) ima…
▽ More
Fluorescence molecular tomography (FMT) is a promising modality for non-invasive imaging of internal fluorescence agents in biological tissues especially in small animal models, with applications in diagnosis, therapy, and drug design. In this paper, we present a new fluorescent reconstruction algorithm that combines time-resolved fluorescence imaging data with photon-counting micro-CT (PCMCT) images to estimate the quantum yield and lifetime of fluorescent markers in a mouse model. By incorporating PCMCT images, a permissible region of interest of fluorescence yield and lifetime can be roughly estimated as prior knowledge, reducing the number of unknown variables in the inverse problem and improving image reconstruction stability. Our numerical simulation results demonstrate the accuracy and stability of this method in the presence of data noise, with an average relative error of 18% in fluorescent yield and lifetime reconstruction.
△ Less
Submitted 10 May, 2023;
originally announced May 2023.
-
Parallel Diffusion Model-based Sparse-view Cone-beam Breast CT
Authors:
Wenjun Xia,
Hsin Wu Tseng,
Chuang Niu,
Wenxiang Cong,
Xiaohua Zhang,
Shaohua Liu,
Ruola Ning,
Srinivasan Vedantham,
Ge Wang
Abstract:
Breast cancer is the most prevalent cancer among women worldwide, and early detection is crucial for reducing its mortality rate and improving quality of life. Dedicated breast computed tomography (CT) scanners offer better image quality than mammography and tomosynthesis in general but at higher radiation dose. To enable breast CT for cancer screening, the challenge is to minimize the radiation d…
▽ More
Breast cancer is the most prevalent cancer among women worldwide, and early detection is crucial for reducing its mortality rate and improving quality of life. Dedicated breast computed tomography (CT) scanners offer better image quality than mammography and tomosynthesis in general but at higher radiation dose. To enable breast CT for cancer screening, the challenge is to minimize the radiation dose without compromising image quality, according to the ALARA principle (as low as reasonably achievable). Over the past years, deep learning has shown remarkable successes in various tasks, including low-dose CT especially few-view CT. Currently, the diffusion model presents the state of the art for CT reconstruction. To develop the first diffusion model-based breast CT reconstruction method, here we report innovations to address the large memory requirement for breast cone-beam CT reconstruction and high computational cost of the diffusion model. Specifically, in this study we transform the cutting-edge Denoising Diffusion Probabilistic Model (DDPM) into a parallel framework for sub-volume-based sparse-view breast CT image reconstruction in projection and image domains. This novel approach involves the concurrent training of two distinct DDPM models dedicated to processing projection and image data synergistically in the dual domains. Our experimental findings reveal that this method delivers competitive reconstruction performance at half to one-third of the standard radiation doses. This advancement demonstrates an exciting potential of diffusion-type models for volumetric breast reconstruction at high-resolution with much-reduced radiation dose and as such hopefully redefines breast cancer screening and diagnosis.
△ Less
Submitted 28 January, 2024; v1 submitted 22 March, 2023;
originally announced March 2023.
-
Patch-Based Denoising Diffusion Probabilistic Model for Sparse-View CT Reconstruction
Authors:
Wenjun Xia,
Wenxiang Cong,
Ge Wang
Abstract:
Sparse-view computed tomography (CT) can be used to reduce radiation dose greatly but is suffers from severe image artifacts. Recently, the deep learning based method for sparse-view CT reconstruction has attracted a major attention. However, neural networks often have a limited ability to remove the artifacts when they only work in the image domain. Deep learning-based sinogram processing can ach…
▽ More
Sparse-view computed tomography (CT) can be used to reduce radiation dose greatly but is suffers from severe image artifacts. Recently, the deep learning based method for sparse-view CT reconstruction has attracted a major attention. However, neural networks often have a limited ability to remove the artifacts when they only work in the image domain. Deep learning-based sinogram processing can achieve a better anti-artifact performance, but it inevitably requires feature maps of the whole image in a video memory, which makes handling large-scale or three-dimensional (3D) images rather challenging. In this paper, we propose a patch-based denoising diffusion probabilistic model (DDPM) for sparse-view CT reconstruction. A DDPM network based on patches extracted from fully sampled projection data is trained and then used to inpaint down-sampled projection data. The network does not require paired full-sampled and down-sampled data, enabling unsupervised learning. Since the data processing is patch-based, the deep learning workflow can be distributed in parallel, overcoming the memory problem of large-scale data. Our experiments show that the proposed method can effectively suppress few-view artifacts while faithfully preserving textural details.
△ Less
Submitted 18 November, 2022;
originally announced November 2022.
-
Phase function estimation from a diffuse optical image via deep learning
Authors:
Yuxuan Liang,
Chuang Niu,
Chen Wei,
Shenghan Ren,
Wenxiang Cong,
Ge Wang
Abstract:
The phase function is a key element of a light propagation model for Monte Carlo (MC) simulation, which is usually fitted with an analytic function with associated parameters. In recent years, machine learning methods were reported to estimate the parameters of the phase function of a particular form such as the Henyey-Greenstein phase function but, to our knowledge, no studies have been performed…
▽ More
The phase function is a key element of a light propagation model for Monte Carlo (MC) simulation, which is usually fitted with an analytic function with associated parameters. In recent years, machine learning methods were reported to estimate the parameters of the phase function of a particular form such as the Henyey-Greenstein phase function but, to our knowledge, no studies have been performed to determine the form of the phase function. Here we design a convolutional neural network to estimate the phase function from a diffuse optical image without any explicit assumption on the form of the phase function. Specifically, we use a Gaussian mixture model as an example to represent the phase function generally and learn the model parameters accurately. The Gaussian mixture model is selected because it provides the analytic expression of phase function to facilitate deflection angle sampling in MC simulation, and does not significantly increase the number of free parameters. Our proposed method is validated on MC-simulated reflectance images of typical biological tissues using the Henyey-Greenstein phase function with different anisotropy factors. The effects of field of view (FOV) and spatial resolution on the errors are analyzed to optimize the estimation method. The mean squared error of the phase function is 0.01 and the relative error of the anisotropy factor is 3.28%.
△ Less
Submitted 15 November, 2021;
originally announced November 2021.
-
Clinical Micro-CT Empowered by Interior Tomography, Robotic Scanning, and Deep Learning
Authors:
Mengzhou Li,
Zheng Fang,
Wenxiang Cong,
Chuang Niu,
Weiwen Wu,
Josef Uher,
James Bennett,
Jay T. Rubinstein,
Ge Wang
Abstract:
While micro-CT systems are instrumental in preclinical research, clinical micro-CT imaging has long been desired with cochlear implantation as a primary example. The structural details of the cochlear implant and the temporal bone require a significantly higher image resolution than that (about 0.2 mm) provided by current medical CT scanners. In this paper, we propose a clinical micro-CT (CMCT) sy…
▽ More
While micro-CT systems are instrumental in preclinical research, clinical micro-CT imaging has long been desired with cochlear implantation as a primary example. The structural details of the cochlear implant and the temporal bone require a significantly higher image resolution than that (about 0.2 mm) provided by current medical CT scanners. In this paper, we propose a clinical micro-CT (CMCT) system design integrating conventional spiral cone-beam CT, contemporary interior tomography, deep learning techniques, and technologies of micro-focus X-ray source, photon-counting detector (PCD), and robotic arms for ultrahigh resolution localized tomography of a freely-selected volume of interest (VOI) at a minimized radiation dose level. The whole system consists of a standard CT scanner for a clinical CT exam and VOI specification, and a robotic-arm based micro-CT scanner for a local scan at much higher spatial and spectral resolution as well as much reduced radiation dose. The prior information from global scan is also fully utilized for background compensation to improve interior tomography from local data for accurate and stable VOI reconstruction. Our results and analysis show that the proposed hybrid reconstruction algorithm delivers superior local reconstruction, being insensitive to the misalignment of the isocenter position and initial view angle in the data/image registration while the attenuation error caused by scale mismatch can be effectively addressed with bias correction. These findings demonstrate the feasibility of our system design. We envision that deep learning techniques can be leveraged for optimized imaging performance. With high resolution imaging, high dose efficiency and low system cost synergistically, our proposed CMCT system has great potentials in temporal bone imaging as well as various other clinical applications.
△ Less
Submitted 16 November, 2020;
originally announced November 2020.
-
X-ray Monochromatic Imaging from Single-spectrum CT via Machine Learning
Authors:
Wenxiang Cong,
Bruno De Man,
Ge Wang
Abstract:
In clinical CT system, the x-ray tube emits polychromatic x-rays, and the x-ray detectors operate in the current-integrating mode. This physical process is accurately described by an energy-dependent non-linear integral equation. However, the non-linear model is not invertible with a computationally efficient solution, and is often approximated as a linear integral model in the form of the Radon t…
▽ More
In clinical CT system, the x-ray tube emits polychromatic x-rays, and the x-ray detectors operate in the current-integrating mode. This physical process is accurately described by an energy-dependent non-linear integral equation. However, the non-linear model is not invertible with a computationally efficient solution, and is often approximated as a linear integral model in the form of the Radon transform. Such approximation basically ignores energy-dependent information and would generate beam hardening artifacts. Dual-energy CT (DECT) scans one object using two different x-ray energy spectra for the acquisition of two spectrally distinct projection datasets to improve imaging performance. Thus, DECT can reconstruct energy and material-selective images, realizing monochromatic imaging and material decomposition. Nevertheless, DECT would increase radiation dose, system complexity, and equipment cost relative to single-spectrum CT. In this paper, a machine-learning-based CT reconstruction method is proposed to perform monochromatic image reconstruction using a single-spectrum CT scanner. Specifically, a residual neural network (ResNet) model is adapted to map a CT image to a monochromatic counterpart at a pre-specified energy level. This ResNet is trained on clinical dual-energy data, showing an excellent convergence to a minimal loss. The trained network produces high-quality monochromatic images on testing data, with a relative error of less than 0.2%. This work has great potential in clinical DECT applications such as tissue characterization, beam hardening correction and proton therapy planning.
△ Less
Submitted 21 June, 2020; v1 submitted 10 June, 2020;
originally announced June 2020.
-
Deep-learning-based Breast CT for Radiation Dose Reduction
Authors:
Wenxiang Cong,
Hongming Shan,
Xiaohua Zhang,
Shaohua Liu,
Ruola Ning,
Ge Wang
Abstract:
Cone-beam breast computed tomography (CT) provides true 3D breast images with isotropic resolution and high-contrast information, detecting calcifications as small as a few hundred microns and revealing subtle tissue differences. However, breast is highly sensitive to x-ray radiation. It is critically important for healthcare to reduce radiation dose. Few-view cone-beam CT only uses a fraction of…
▽ More
Cone-beam breast computed tomography (CT) provides true 3D breast images with isotropic resolution and high-contrast information, detecting calcifications as small as a few hundred microns and revealing subtle tissue differences. However, breast is highly sensitive to x-ray radiation. It is critically important for healthcare to reduce radiation dose. Few-view cone-beam CT only uses a fraction of x-ray projection data acquired by standard cone-beam breast CT, enabling significant reduction of the radiation dose. However, insufficient sampling data would cause severe streak artifacts in CT images reconstructed using conventional methods. In this study, we propose a deep-learning-based method to establish a residual neural network model for the image reconstruction, which is applied for few-view breast CT to produce high quality breast CT images. We respectively evaluate the deep-learning-based image reconstruction using one third and one quarter of x-ray projection views of the standard cone-beam breast CT. Based on clinical breast imaging dataset, we perform a supervised learning to train the neural network from few-view CT images to corresponding full-view CT images. Experimental results show that the deep learning-based image reconstruction method allows few-view breast CT to achieve a radiation dose <6 mGy per cone-beam CT scan, which is a threshold set by FDA for mammographic screening.
△ Less
Submitted 25 September, 2019;
originally announced September 2019.
-
Projection Decomposition for Dual-energy Computed Tomography
Authors:
Wenxiang Cong,
Daniel Harrison,
Yan Xi,
Ge Wang
Abstract:
Dual-energy computed tomography (CT) is to reconstruct images of an object from two projection datasets generated from two distinct x-ray source energy spectra. It can provide more accurate attenuation quantification than conventional CT with a single x-ray energy spectrum. In the diagnostic energy range, x-ray energy-dependent attenuation can be approximated as a linear combination of photoelectr…
▽ More
Dual-energy computed tomography (CT) is to reconstruct images of an object from two projection datasets generated from two distinct x-ray source energy spectra. It can provide more accurate attenuation quantification than conventional CT with a single x-ray energy spectrum. In the diagnostic energy range, x-ray energy-dependent attenuation can be approximated as a linear combination of photoelectric absorption and Compton scattering. Hence, two physical components of x-ray attenuation can be determined from two spectral informative projection datasets to achieve monochromatic imaging and material decomposition. In this paper, a projection decomposition method is proposed for the image reconstruction in dual-energy CT. This method combines both an analytical algorithm and a single-variable optimization method to solve the non-linear polychromatic x-ray integral model, allowing accurate quantification of photoelectric absorption and Compton scattering components. Numerical tests are performed to illustrate the merit of the proposed method by comparing with classical projection decomposition methods.
△ Less
Submitted 14 May, 2018;
originally announced May 2018.
-
Monochromatic CT Image Reconstruction from Current-Integrating Data via Deep Learning
Authors:
Wenxiang Cong,
Ge Wang
Abstract:
In clinical CT, the x-ray source emits polychromatic x-rays, which are detected in the current-integrating mode. This physical process is accurately described by an energy-dependent non-linear integral model on the basis of the Beer-Lambert law. However, the non-linear model is too complicated to be directly solved for the image reconstruction, and is often approximated to a linear integral model…
▽ More
In clinical CT, the x-ray source emits polychromatic x-rays, which are detected in the current-integrating mode. This physical process is accurately described by an energy-dependent non-linear integral model on the basis of the Beer-Lambert law. However, the non-linear model is too complicated to be directly solved for the image reconstruction, and is often approximated to a linear integral model in the form of the Radon transform, basically ignoring energy-dependent information. This model approximation would generate inaccurate quantification of attenuation image and significant beam-hardening artifacts. In this paper, we develop a deep-learning-based CT image reconstruction method to address the mismatch of computing model to physical model. Our method learns a nonlinear transformation from big data to correct measured projection data to accurately match the linear integral model, realize monochromatic imaging and overcome beam hardening effectively. The deep-learning network is trained and tested using clinical dual-energy dataset to demonstrate the feasibility of the proposed methodology. Results show that the proposed method can achieve a high accuracy of the projection correction with a relative error of less than 0.2%.
△ Less
Submitted 9 January, 2018; v1 submitted 10 October, 2017;
originally announced October 2017.
-
Development of a focused-X-ray luminescence tomography (FXLT) system
Authors:
Michael C Lun,
Wei Zhang,
Yue Zhao,
Jeffrey Anker,
Wenxiang Cong,
Ge Wang,
Changqing Li
Abstract:
Biophotonics is an active research area in molecular imaging, genetic diagnosis and prognosis, with direct applicability in precision medicine. However, long-standing challenges of biophotonics are well known due to low signal-to-noise ratio and poor image quality, mainly due to strong optical scattering especially in deep tissues. Recently, X-ray luminescence computed tomography (XLCT) has emerge…
▽ More
Biophotonics is an active research area in molecular imaging, genetic diagnosis and prognosis, with direct applicability in precision medicine. However, long-standing challenges of biophotonics are well known due to low signal-to-noise ratio and poor image quality, mainly due to strong optical scattering especially in deep tissues. Recently, X-ray luminescence computed tomography (XLCT) has emerged as a hybrid molecular imaging modality and shown great promises in overcoming the optical scattering in deep tissues. However, its high spatial resolution capacity has not been fully implemented yet. In this paper, with a superfine focused X-ray beam we design a focused-X-ray luminescence tomography (FXLT) system for spatial resolution better than 150 micrometers and molecular sensitivity of 2 micromolar. First, we describe our system design. Then, we demonstrate that the molecular sensitivity of FXLT is about 5 micromolar considering the emitted visible photons from background. Furthermore, we analyze the measurement time per scan from measured photons numbers with a fiber bundle-PMT setup, report numerical and experimental results. Finally, we specify the imaging system performance based on numerical simulations and physical measurements.
△ Less
Submitted 28 September, 2017;
originally announced September 2017.
-
Reconstruction of optical parameters for molecular tomographic imaging
Authors:
Wenxiang Cong,
Xavier Intes,
Ge Wang
Abstract:
Optical molecular tomographic imaging is to reconstruct the concentration distribution of photon-molecular probes in a small animal from measured photon fluence rates. The localization and quantification of molecular probes is related to tissue optical properties. The optical parameters can be reconstructed by the optimization method, in which the objective function is not convex, and there are mu…
▽ More
Optical molecular tomographic imaging is to reconstruct the concentration distribution of photon-molecular probes in a small animal from measured photon fluence rates. The localization and quantification of molecular probes is related to tissue optical properties. The optical parameters can be reconstructed by the optimization method, in which the objective function is not convex, and there are multiple local optimal solutions. The gradient-based optimization algorithm could converge prematurely to an inaccurate solution if the initial guess is not close enough to the true solution. In this paper, we develop a hybrid algorithm combined global optimization and gradient-based optimization methods to reconstruct optical parameters. Differential evolution is an effective global optimizer, and could yield an estimated solution near the global optimal region to eliminate the need of initial guess of the optical parameters. The gradient-based optimization method is further performed with initial values obtained from DE to obtain local optimal solution for more accurate reconstruction of optical parameters. This proposed reconstruction method is evaluated by comprehensive numerical simulation experiments. The results show that the proposed method is stable and accurate for the reconstruction of optical parameters.
△ Less
Submitted 15 July, 2017; v1 submitted 4 July, 2017;
originally announced July 2017.
-
Optical Tomographic Imaging for Breast Cancer Detection
Authors:
Wenxiang Cong,
Xavier Intes,
Ge Wang
Abstract:
Diffuse optical breast imaging utilizes near-infrared (NIR) light propagation through tissues to assess the optical properties of tissue for the identification of abnormal tissue. This optical imaging approach is sensitive, cost-effective, and does not involve any ionizing radiation. However, the image reconstruction of diffuse optical tomography (DOT) is a nonlinear inverse problem and suffers fr…
▽ More
Diffuse optical breast imaging utilizes near-infrared (NIR) light propagation through tissues to assess the optical properties of tissue for the identification of abnormal tissue. This optical imaging approach is sensitive, cost-effective, and does not involve any ionizing radiation. However, the image reconstruction of diffuse optical tomography (DOT) is a nonlinear inverse problem and suffers from severe ill-posedness, especially in the cases of strong noise and incomplete data. In this paper, a novel image reconstruction method is proposed for the detection of breast cancer. This method split the image reconstruction problem into the localization of abnormal tissues and quantification of absorption variations. The localization of abnormal tissues is performed based on a new well-posed optimization model, which can be solved via differential evolution optimization method to achieve a stable image reconstruction. The quantification of abnormal absorption variations is then determined in localized regions of relatively small extents, which are potentially tumors. Consequently, the number of unknown absorption variables can be greatly reduced to overcome the underdetermined nature of diffuse optical tomography (DOT), allowing for accurate and stable reconstruction of the abnormal absorption variations in the breast. Numerical simulation experiments show that the image reconstruction method is stable and accurate for the identification of abnormal tissues, and robust against measurement noise of data.
△ Less
Submitted 16 April, 2017;
originally announced April 2017.
-
CT Image Reconstruction in a Low Dimensional Manifold
Authors:
Wenxiang Cong,
Ge Wang,
Qingsong Yang,
Jiang Hsieh,
Jia Li,
Rongjie Lai
Abstract:
Regularization methods are commonly used in X-ray CT image reconstruction. Different regularization methods reflect the characterization of different prior knowledge of images. In a recent work, a new regularization method called a low-dimensional manifold model (LDMM) is investigated to characterize the low-dimensional patch manifold structure of natural images, where the manifold dimensionality…
▽ More
Regularization methods are commonly used in X-ray CT image reconstruction. Different regularization methods reflect the characterization of different prior knowledge of images. In a recent work, a new regularization method called a low-dimensional manifold model (LDMM) is investigated to characterize the low-dimensional patch manifold structure of natural images, where the manifold dimensionality characterizes structural information of an image. In this paper, we propose a CT image reconstruction method based on the prior knowledge of the low-dimensional manifold of CT image. Using the clinical raw projection data from GE clinic, we conduct comparisons for the CT image reconstruction among the proposed method, the simultaneous algebraic reconstruction technique (SART) with the total variation (TV) regularization, and the filtered back projection (FBP) method. Results show that the proposed method can successfully recover structural details of an imaging object, and achieve higher spatial and contrast resolution of the reconstructed image than counterparts of FBP and SART with TV.
△ Less
Submitted 16 April, 2017;
originally announced April 2017.
-
Theoretical analysis on x-ray cylindrical grating interferometer
Authors:
Wenxiang Cong,
Yan Xi,
Ge Wang
Abstract:
Grating interferometer is a state of art x-ray imaging approach, which can simultaneously acquire information of x-ray attenuation, phase shift, and small angle scattering. This approach is very sensitive to micro-structural variation and offers superior contrast resolution for biological soft tissues. The present grating interferometer often uses flat gratings, with serious limitations in the fie…
▽ More
Grating interferometer is a state of art x-ray imaging approach, which can simultaneously acquire information of x-ray attenuation, phase shift, and small angle scattering. This approach is very sensitive to micro-structural variation and offers superior contrast resolution for biological soft tissues. The present grating interferometer often uses flat gratings, with serious limitations in the field of view and the flux of photons. The use of curved gratings allows perpendicular incidence of x-rays on the gratings, and gives higher visibility over a larger field of view than a conventional interferometer with flat gratings. In the study, we present a rigorous theoretical analysis of the self-imaging of curved transmission gratings based on Rayleigh-Sommerfeld diffraction. Numerical simulations have demonstrated the self-imaging phenomenon of cylindrical grating interferometer. The theoretical results are in agreement with the results of numerical simulations.
△ Less
Submitted 17 September, 2015; v1 submitted 3 February, 2015;
originally announced February 2015.
-
A Pilot Study on Coupling CT and MRI through Use of Semiconductor Nanoparticles
Authors:
Matthew Getzin,
Lars Gjesteby,
Yen-Jun Chuang,
Scott McCallum,
Wenxiang Cong,
Chao Wang,
Zhengwei Pan,
Guohao Dai,
Ge Wang
Abstract:
CT and MRI are the two most widely used imaging modalities in healthcare, each with its own merits and drawbacks. Combining these techniques in one machine could provide unprecedented resolution and sensitivity in a single scan, and serve as an ideal platform to explore physical coupling of x-ray excitation and magnetic resonance. Molecular probes such as functionalized nanophosphors present an op…
▽ More
CT and MRI are the two most widely used imaging modalities in healthcare, each with its own merits and drawbacks. Combining these techniques in one machine could provide unprecedented resolution and sensitivity in a single scan, and serve as an ideal platform to explore physical coupling of x-ray excitation and magnetic resonance. Molecular probes such as functionalized nanophosphors present an opportunity to demonstrate a synergy between these modalities. However, a simultaneous CT-MRI scanner does not exist at this moment. As a pilot study, here we propose a mechanism in which water solutions containing LiGa5O8:Cr3+ nanophosphors can be excited with x-rays to store energy, and these excited particles may subsequently influence the T2 relaxation times of the solutions so that a difference in T2 can be measured by MRI before and after x-ray excitation. The trends seen in our study suggest that a measurable effect may exist from x-ray excitation of the nanophosphors. However, there are several experimental conditions that hinder the clarity of the results to be statistically significant up to a commonly accepted level (p=0.05), including insoluble nanoparticles and inter-scan variability. Nevertheless, the initial results from our experiments seem a consistent and inspiring story that x-rays modify MRI T2 values around nanophosphors. Upon availability of soluble nanophosphors, we will repeat our experiments to confirm these observations.
△ Less
Submitted 23 December, 2014;
originally announced December 2014.
-
Attenuation map reconstruction from TOF PET data
Authors:
Qingsong Yang,
Wenxiang Cong,
Ge Wang
Abstract:
To reconstruct a radioactive tracer distribution with positron emission tomography (PET), the background attenuation correction is needed to eliminate image artifacts. Recent research shows that time-of-flight (TOF) PET data determine the attenuation sinogram up to a constant, and its gradient can be computed using an analytic algorithm. In this paper, we study a direct estimation of the sinogram…
▽ More
To reconstruct a radioactive tracer distribution with positron emission tomography (PET), the background attenuation correction is needed to eliminate image artifacts. Recent research shows that time-of-flight (TOF) PET data determine the attenuation sinogram up to a constant, and its gradient can be computed using an analytic algorithm. In this paper, we study a direct estimation of the sinogram only from TOF PET data. First, the gradient of the attenuation sinogram is estimated using the aforementioned algorithm. Then, a relationship is established to link the differential attenuation sinogram and the underlying attenuation background. Finally, an iterative algorithm is designed to determine the attenuation sinogram accurately and stably. A 2D numerical simulation study is conducted to verify the correctness of our proposed approach.
△ Less
Submitted 27 December, 2013;
originally announced December 2013.
-
Top-level Design and Pilot Analysis of Low-end CT Scanners Based on Linear Scanning for Develo** Countries
Authors:
Fenglin Liu,
Hengyong Yu,
Wenxiang Cong,
Ge Wang
Abstract:
Purpose: The goal is to develop a new architecture for computed tomography (CT) which is at an ultra-low-dose for develo** countries, especially in rural areas. Methods: The proposed scheme is inspired by the recently developed compressive sensing and interior tomography techniques, where the data acquisition system targets a region of interest (ROI) to acquire limited and truncated data. The so…
▽ More
Purpose: The goal is to develop a new architecture for computed tomography (CT) which is at an ultra-low-dose for develo** countries, especially in rural areas. Methods: The proposed scheme is inspired by the recently developed compressive sensing and interior tomography techniques, where the data acquisition system targets a region of interest (ROI) to acquire limited and truncated data. The source and detector are translated in opposite directions for either ROI reconstruction with one or more localized linear scans or global reconstruction by combining multiple ROI reconstructions. In other words, the popular slip ring is replaced by a translation based setup, and the instrumentation cost is reduced by a relaxation of the imaging speed requirement. Results: The various translational scanning modes are theoretically analyzed, and the scanning parameters are optimized. The numerical simulation results from different numbers of linear scans confirm the feasibility of the proposed scheme, and suggest two preferred low-end systems for horizontal and vertical patient positions respectively. Conclusion: Ultra-low-cost x-ray CT is feasible with our proposed combination of linear scanning, compressive sensing, and interior tomography. The proposed architecture can be tailored into permanent, movable, or reconfigurable systems as desirable. Advanced image registration and spectral imaging features can be included as well.
△ Less
Submitted 20 December, 2013;
originally announced December 2013.
-
Micro-modulated luminescence tomography
Authors:
Wenxiang Cong,
Fenglin Liu,
Chao Wang,
Ge Wang
Abstract:
Imaging depth of optical microscopy has been fundamentally limited to millimeter or sub-millimeter due to light scattering. X-ray microscopy can resolve spatial details of few microns deeply inside a sample but the contrast resolution is still inadequate to depict heterogeneous features at cellular or sub-cellular levels. To enhance and enrich biological contrast at large imaging depth, various na…
▽ More
Imaging depth of optical microscopy has been fundamentally limited to millimeter or sub-millimeter due to light scattering. X-ray microscopy can resolve spatial details of few microns deeply inside a sample but the contrast resolution is still inadequate to depict heterogeneous features at cellular or sub-cellular levels. To enhance and enrich biological contrast at large imaging depth, various nanoparticles are introduced and become essential to basic research and molecular medicine. Nanoparticles can be functionalized as imaging probes, similar to fluorescent and bioluminescent proteins. LiGa5O8:Cr3+ nanoparticles were recently synthesized to facilitate luminescence energy storage with x-ray pre-excitation and the subsequently stimulated luminescence emission by visible/near-infrared (NIR) light. In this paper, we suggest a micro-modulated luminescence tomography (MLT) approach to quantify a nanophosphor distribution in a thick biological sample with high resolution. Our numerical simulation studies demonstrate the feasibility of the proposed approach.
△ Less
Submitted 16 November, 2013;
originally announced November 2013.
-
Stored Luminescence Computed Tomography
Authors:
Wenxiang Cong,
Chao Wang,
Ge Wang
Abstract:
The phosphor nanoparticles made of doped semiconductors, pre-excited by well-collimated X-ray radiation, were recently reported for their light emission upon NIR light stimulation. The characteristics of X-ray energy storage and NIR stimulated emission is highly desirable to design targeting probes and improve molecular and cellular imaging. Here we propose stored luminescence computed tomography…
▽ More
The phosphor nanoparticles made of doped semiconductors, pre-excited by well-collimated X-ray radiation, were recently reported for their light emission upon NIR light stimulation. The characteristics of X-ray energy storage and NIR stimulated emission is highly desirable to design targeting probes and improve molecular and cellular imaging. Here we propose stored luminescence computed tomography (SLCT), perform realistic numerical simulation, and demonstrate a much-improved spatial resolution in a preclinical research context. The future opportunities are also discussed along this direction.
△ Less
Submitted 13 September, 2013;
originally announced September 2013.
-
Dynamic Bowtie for Fan-beam CT
Authors:
Fenglin Liu,
Ge Wang,
Wenxiang Cong,
Scott Hsieh,
Norbert Pelc
Abstract:
A bowtie is a filter used to shape an x-ray beam and equalize its flux reaching different detector channels. For development of spectral CT with energy-discriminative photon-counting (EDPC) detectors, here we propose and evaluate a dynamic bowtie for performance optimization based on a patient model or a scout scan. Our dynamic bowtie modifies an x-ray beam intensity profile by mechanical rotation…
▽ More
A bowtie is a filter used to shape an x-ray beam and equalize its flux reaching different detector channels. For development of spectral CT with energy-discriminative photon-counting (EDPC) detectors, here we propose and evaluate a dynamic bowtie for performance optimization based on a patient model or a scout scan. Our dynamic bowtie modifies an x-ray beam intensity profile by mechanical rotation and adaptive adjustment of the x-ray source flux. First, a mathematical model for dynamic bowtie filtering is established for an elliptical section in fan-beam geometry, and the contour of the optimal bowtie is derived. Then, numerical simulation is performed to compare the performance of the dynamic bowtie in the cases of an ideal phantom and a realistic cross-section relative to the counterparts without any bowtie and with a fixed bowtie respectively. Our dynamic bowtie can equalize the expected numbers of photons in the case of an ideal phantom. In practical cases, our dynamic bowtie can effectively reduce the dynamic range of detected signals inside the field of view. Although our design is optimized for an elliptical phantom, the resultant dynamic bowtie can be applied to a real fan-beam scan if the underlying cross-section can be approximated as an ellipse. Furthermore, our design methodology can be applied to specify an optimized dynamic bowtie for any cross-section of a patient, preferably using rapid prototy** technology. This fan-beam dynamic bowtie work could be extended to the cone-beam geometry in a follow-up study.
△ Less
Submitted 29 April, 2013;
originally announced April 2013.
-
Analytic Comparison between X-ray Fluorescence CT and K-edge CT
Authors:
Peng Feng,
Ge Wang,
Wenxiang Cong,
Biao Wei
Abstract:
X-ray fluorescence computed tomography (XFCT) and K-edge computed tomography (CT) are two important modalities to quantify a distribution of gold nanoparticles (GNPs) in a small animal for preclinical studies. It is valuable to determine which modality is more efficient for a given application. In this paper, we report a theoretical analysis in terms of signal-to-noise ratio (SNR) for the two moda…
▽ More
X-ray fluorescence computed tomography (XFCT) and K-edge computed tomography (CT) are two important modalities to quantify a distribution of gold nanoparticles (GNPs) in a small animal for preclinical studies. It is valuable to determine which modality is more efficient for a given application. In this paper, we report a theoretical analysis in terms of signal-to-noise ratio (SNR) for the two modalities, showing that there is a threshold for the GNPs concentration and XFCT has a better SNR than K-edge CT if GNPs concentration is less than this threshold. Numerical simulations are performed and two kinds of phantoms are used to represent multiple concentration levels and feature sizes. Experimental results illustrate that XFCT is superior to K-edge CT when contrast concentration is lower than 0.4% which coincides with the theoretical analysis.
△ Less
Submitted 5 April, 2013;
originally announced April 2013.
-
X-ray Fluorescence Sectioning
Authors:
Wenxiang Cong,
Ge Wang
Abstract:
In this paper, we propose an x-ray fluorescence imaging system for elemental analysis. The key idea is what we call "x-ray fluorescence sectioning". Specifically, a slit collimator in front of an x-ray tube is used to shape x-rays into a fan-beam to illuminate a planar section of an object. Then, relevant elements such as gold nanoparticles on the fan-beam plane are excited to generate x-ray fluor…
▽ More
In this paper, we propose an x-ray fluorescence imaging system for elemental analysis. The key idea is what we call "x-ray fluorescence sectioning". Specifically, a slit collimator in front of an x-ray tube is used to shape x-rays into a fan-beam to illuminate a planar section of an object. Then, relevant elements such as gold nanoparticles on the fan-beam plane are excited to generate x-ray fluorescence signals. One or more 2D spectral detectors are placed to face the fan-beam plane and directly measure x-ray fluorescence data. Detector elements are so collimated that each element only sees a unique area element on the fan-beam plane and records the x-ray fluorescence signal accordingly. The measured 2D x-ray fluorescence data can be refined in reference to the attenuation characteristics of the object and the divergence of the beam for accurate elemental map**. This x-ray fluorescence sectioning system promises fast fluorescence tomographic imaging without a complex inverse procedure. The design can be adapted in various ways, such as with the use of a larger detector size to improve the signal to noise ratio. In this case, the detector(s) can be shifted multiple times for image deblurring.
△ Less
Submitted 26 October, 2012;
originally announced October 2012.
-
Differential Phase-contrast Interior Tomography
Authors:
Wenxiang Cong,
Ge Wang
Abstract:
Differential phase contrast interior tomography allows for reconstruction of a refractive index distribution over a region of interest (ROI) for visualization and analysis of internal structures inside a large biological specimen. In this imaging mode, x-ray beams target the ROI with a narrow beam aperture, offering more imaging flexibility at less ionizing radiation. Inspired by recently develope…
▽ More
Differential phase contrast interior tomography allows for reconstruction of a refractive index distribution over a region of interest (ROI) for visualization and analysis of internal structures inside a large biological specimen. In this imaging mode, x-ray beams target the ROI with a narrow beam aperture, offering more imaging flexibility at less ionizing radiation. Inspired by recently developed compressive sensing theory, in numerical analysis framework, we prove that exact interior reconstruction can be achieved on an ROI via the total variation minimization from truncated differential projection data through the ROI, assuming a piecewise constant distribution of the refractive index in the ROI. Then, we develop an iterative algorithm for the interior reconstruction and perform numerical simulation experiments to demonstrate the feasibility of our proposed approach.
△ Less
Submitted 5 August, 2011;
originally announced August 2011.
-
Fourier transform based iterative method for x-ray differential phase-contrast computed tomography
Authors:
Wenxiang Cong,
Atsushi Momose,
Ge Wang
Abstract:
Biological soft tissues encountered in clinical and pre-clinical imaging mainly consist of light element atoms, and their composition is nearly uniform with little density variation. Thus, x-ray attenuation imaging suffers from low image contrast resolution. By contrast, x-ray phase shift of soft tissues is about a thousand times greater than x-ray absorption over the diagnostic energy range, ther…
▽ More
Biological soft tissues encountered in clinical and pre-clinical imaging mainly consist of light element atoms, and their composition is nearly uniform with little density variation. Thus, x-ray attenuation imaging suffers from low image contrast resolution. By contrast, x-ray phase shift of soft tissues is about a thousand times greater than x-ray absorption over the diagnostic energy range, thereby a significantly higher sensitivity can be achieved in terms of phase shift. In this paper, we propose a novel Fourier transform based iterative method to perform x-ray tomographic imaging of the refractive index directly from differential phase shift data. This approach offers distinct advantages in cases of incomplete and noisy data than analytic reconstruction, and especially suitable for phase-contrast interior tomography by incorporating prior knowledge in a region of interest (ROI). Biological experiments demonstrate the merits of the proposed approach.
△ Less
Submitted 24 June, 2011;
originally announced June 2011.
-
Omni-tomography/Multi-tomography -- Integrating Multiple Modalities for Simultaneous Imaging
Authors:
Ge Wang,
Jie Zhang,
Hao Gao,
Victor Weir,
Hengyong Yu,
Wenxiang Cong,
Xiaochen Xu,
Haiou Shen,
James Bennett,
Yue Wang,
Michael Vannier
Abstract:
Current tomographic imaging systems need major improvements, especially when multi-dimensional, multi-scale, multi-temporal and multi-parametric phenomena are under investigation. Both preclinical and clinical imaging now depend on in vivo tomography, often requiring separate evaluations by different imaging modalities to define morphologic details, delineate interval changes due to disease or int…
▽ More
Current tomographic imaging systems need major improvements, especially when multi-dimensional, multi-scale, multi-temporal and multi-parametric phenomena are under investigation. Both preclinical and clinical imaging now depend on in vivo tomography, often requiring separate evaluations by different imaging modalities to define morphologic details, delineate interval changes due to disease or interventions, and study physiological functions that have interconnected aspects. Over the past decade, fusion of multimodality images has emerged with two different approaches: post-hoc image registration and combined acquisition on PET-CT, PET-MRI and other hybrid scanners. There are intrinsic limitations for both the post-hoc image analysis and dual/triple modality approaches defined by registration errors and physical constraints in the acquisition chain. We envision that tomography will evolve beyond current modality fusion and towards grand fusion, a large scale fusion of all or many imaging modalities, which may be referred to as omni-tomography or multi-tomography. Unlike modality fusion, grand fusion is here proposed for truly simultaneous but often localized reconstruction in terms of all or many relevant imaging mechanisms such as CT, MRI, PET, SPECT, US, optical, and possibly more. In this paper, the technical basis for omni-tomography is introduced and illustrated with a top-level design of a next generation scanner, interior tomographic reconstructions of representative modalities, and anticipated applications of omni-tomography.
△ Less
Submitted 10 June, 2011;
originally announced June 2011.
-
Higher-order Reconstruction Method of Differential Phase Shift
Authors:
Wenxiang Cong,
Ge Wang
Abstract:
In this paper, we develop a novel phase retrieval approach to reconstruct x-ray differential phase shift induced by an object. A primary advantage of our approach is a higher-order accuracy over that with the conventional linear approximation models, relaxing the current restriction of weak absorption and slow phase variation scenario. The optimal utilization of the diffraction images at different…
▽ More
In this paper, we develop a novel phase retrieval approach to reconstruct x-ray differential phase shift induced by an object. A primary advantage of our approach is a higher-order accuracy over that with the conventional linear approximation models, relaxing the current restriction of weak absorption and slow phase variation scenario. The optimal utilization of the diffraction images at different distance in Fresnel diffraction region eliminates the nonlinear terms in phase and attenuation, and simplifies the reconstruction to a linear inverse problem. Numerical studies are also described to demonstrate the accuracy and stability of our approach.
△ Less
Submitted 16 March, 2010;
originally announced March 2010.
-
Dark-field Tomography: Modeling and Reconstruction
Authors:
W. Cong,
F. Pfeiffer,
M. Bech,
O. Bunk,
C. David,
G. Wang
Abstract:
Dark-field images are formed by small-angle scattering of x-ray photons. The small-angle scattering signal is particularly sensitive to structural variations and density fluctuation on a length scale of several ten to hundred nanometers, offering a new contrast mechanism to reveal subtle structural variation of object. In this paper, we derive a novel physical model to describe x-ray absorption an…
▽ More
Dark-field images are formed by small-angle scattering of x-ray photons. The small-angle scattering signal is particularly sensitive to structural variations and density fluctuation on a length scale of several ten to hundred nanometers, offering a new contrast mechanism to reveal subtle structural variation of object. In this paper, we derive a novel physical model to describe x-ray absorption and small-angle scattering, and use the proposed model to reconstruct the volumetric small-angle scattering images. The numerical experiments and test experiments demonstrate that the reconstructed scattering images reveal unique features with a high contrast resolution. The proposed approach has great potential in biomedical imaging, nondestructive detections, and other applications.
△ Less
Submitted 10 March, 2010;
originally announced March 2010.