-
Imaging nanomechanical vibrations and manipulating parametric mode coupling via scanning microwave microscopy
Authors:
Hao Xu,
Srisaran Venkatachalam,
Toky-Harrison Rabenimanana,
Christophe Boyaval,
Sophie Eliet,
Flavie Braud,
Eddy Collin,
Didier Theron,
Xin Zhou
Abstract:
In this study, we present a novel platform based on scanning microwave microscopy for manipulating and detecting tiny vibrations of nanoelectromechanical resonators using a single metallic tip. The tip is placed on the top of a grounded silicon nitride membrane, acting as a movable top gate of the coupled resonator. We demonstrate its ability to map mechanical modes and investigate mechanical damp…
▽ More
In this study, we present a novel platform based on scanning microwave microscopy for manipulating and detecting tiny vibrations of nanoelectromechanical resonators using a single metallic tip. The tip is placed on the top of a grounded silicon nitride membrane, acting as a movable top gate of the coupled resonator. We demonstrate its ability to map mechanical modes and investigate mechanical dam** effects in a capacitive coupling scheme, based on its spatial resolution. We also manipulate the energy transfer coherently between the mode of the scanning tip and the underlying silicon nitride membrane, via parametric coupling. Typical features of optomechanics, such as anti-dam** and electromechanically induced transparency, have been observed. Since the microwave optomechanical technology is fully compatible with quantum electronics and very low temperature conditions, it should provide a powerful tool for studying phonon tunnelling between two spatially separated vibrating elements, which could potentially be applied to quantum sensing.
△ Less
Submitted 28 June, 2024;
originally announced July 2024.
-
Aluminum nuclear demagnetization refrigerator for powerful continuous cooling
Authors:
Matthias Raba,
Sébastien Triqueneaux,
James Butterworth,
David Schmoranzer,
Emilio Barria,
Jérôme Debray,
Guillaume Donnier-Valentin,
Thibaut Gandit,
Anne Gerardin,
Johannes Goupy,
Olivier Tissot,
Eddy Collin,
Andrew Fefferman
Abstract:
Many laboratories routinely cool samples to 10 mK, but relatively few can cool condensed matter below 1 mK. Easy access to the microkelvin range would propel fields such as quantum sensors and quantum materials. Such temperatures are achieved with adiabatic nuclear demagnetization. Existing nuclear demagnetization refrigerators (NDR) are "single-shot", and the recycling time is incompatible with p…
▽ More
Many laboratories routinely cool samples to 10 mK, but relatively few can cool condensed matter below 1 mK. Easy access to the microkelvin range would propel fields such as quantum sensors and quantum materials. Such temperatures are achieved with adiabatic nuclear demagnetization. Existing nuclear demagnetization refrigerators (NDR) are "single-shot", and the recycling time is incompatible with proposed sub-mK experiments. Furthermore, a high cooling power is required to overcome the excess heat load of order nW on NDR pre-cooled by cryogen-free dilution refrigerators. We report the performance of an aluminum NDR designed for powerful cooling when part of a dual stage continuous NDR (CNDR). Its thermal resistance is minimized to maximize the cycling rate of the CNDR and consequently its cooling power. At the same time, its susceptibility to eddy current heating is minimized. A CNDR based on two of the aluminum NDR presented here would have a cooling power of approximately 40 nW at 560 $μ$K.
△ Less
Submitted 30 April, 2024;
originally announced April 2024.
-
Superconducting aluminum heat switch with 3 n$Ω$ equivalent resistance
Authors:
James Butterworth,
Sébastien Triqueneaux,
Šimon Midlik,
Ilya Golokolenov,
Anne Gerardin,
Thibaut Gandit,
Guillaume Donnier-Valentin,
Johannes Goupy,
M. Keith Phuthi,
David Schmoranzer,
Eddy Collin,
Andrew Fefferman
Abstract:
Superconducting heat switches with extremely low normal state resistances are needed for constructing continuous nuclear demagnetization refrigerators with high cooling power. Aluminum is a suitable superconductor for the heat switch because of its high Debye temperature and its commercial availability in high purity. We have constructed a high quality Al heat switch whose design is significantly…
▽ More
Superconducting heat switches with extremely low normal state resistances are needed for constructing continuous nuclear demagnetization refrigerators with high cooling power. Aluminum is a suitable superconductor for the heat switch because of its high Debye temperature and its commercial availability in high purity. We have constructed a high quality Al heat switch whose design is significantly different than that of previous heat switches. In order to join the Al to Cu with low contact resistance, we plasma etched the Al to remove its oxide layer then immediately deposited Au without breaking the vacuum of the e-beam evaporator. In the normal state of the heat switch, we measured a thermal conductance of $8 T$ W/K$^2$ which is equivalent to an electrical resistance of 3 n$Ω$ according to the Wiedemann-Franz law. In the superconducting state we measured a thermal conductance that is $2\times10^6$ times lower than that of the normal state at 50 mK.
△ Less
Submitted 23 April, 2022; v1 submitted 23 November, 2021;
originally announced November 2021.
-
Develo** compact tuning fork thermometers for sub-mK temperatures and high magnetic fields
Authors:
Andrew J. Woods,
Alexander. M. Donald,
Rasul Gazizulin,
Eddy Collin,
Lucia Steinke
Abstract:
There is a growing demand for experiments on calorimetric and thermal transport measurements at ultra-low temperatures below 1 mK and high magnetic fields up to 16 T. Particularly, milligram-sized solid samples are of great interest. We present the development of scalable thermometers based on quartz tuning fork resonators immersed in liquid 3He and adapt hydrodynamic models to provide an improved…
▽ More
There is a growing demand for experiments on calorimetric and thermal transport measurements at ultra-low temperatures below 1 mK and high magnetic fields up to 16 T. Particularly, milligram-sized solid samples are of great interest. We present the development of scalable thermometers based on quartz tuning fork resonators immersed in liquid 3He and adapt hydrodynamic models to provide an improved description of temperature dependence in the high viscosity regime between 1 and 10 mK. We demonstrate successful thermometer operation and discuss the feasibility of fast and compact thermal probes suitable for small samples.
△ Less
Submitted 13 October, 2022; v1 submitted 6 July, 2021;
originally announced July 2021.
-
High-Q silicon nitride drum resonators strongly coupled to gates
Authors:
Xin Zhou,
Srisaran Venkatachalam,
Ronghua Zhou,
Hao Xu,
Alok Pokharel,
Andrew Fefferman,
Mohammed Zaknoune,
Eddy Collin
Abstract:
Silicon nitride (SiN) mechanical resonators with high quality mechanical properties are attractive for fundamental research and applications. However, it is challenging to maintain these mechanical properties while achieving strong coupling to an electrical circuit for efficient on-chip integration. Here, we present a SiN drum resonator covered with an aluminum thin film, enabling large capacitive…
▽ More
Silicon nitride (SiN) mechanical resonators with high quality mechanical properties are attractive for fundamental research and applications. However, it is challenging to maintain these mechanical properties while achieving strong coupling to an electrical circuit for efficient on-chip integration. Here, we present a SiN drum resonator covered with an aluminum thin film, enabling large capacitive coupling to a suspended top-gate. Implementing the full electrical measurement scheme, we demonstrate a high quality factor ~ 1E4 (comparable to that of bare drums at room temperature) and present our ability to detect ? 10 mechanical modes at low temperature. The drum resonator is also coupled to a microwave cavity, so that we can perform optomechanical sideband pum** with a fairly good coupling strength G and demonstrate mechanical parametric amplification. This SiN drum resonator design provides efficient electrical integration and exhibits promising features for exploring mode coupling and signal processing.
△ Less
Submitted 16 June, 2021; v1 submitted 14 April, 2021;
originally announced April 2021.
-
Very low resistance Al/Cu joints for use at cryogenic temperatures
Authors:
Sébastien Triqueneaux,
James Butterworth,
Johannes Goupy,
Clément Ribas,
David Schmoranzer,
Eddy Collin,
Andrew Fefferman
Abstract:
We present two different techniques for achieving low resistance ($<$20 n$\rm Ω$) contacts between copper and aluminium at cryogenic temperatures. The best method is based on gold plating of the surfaces in an e-beam evaporator immediately after Ar plasma etching in the same apparatus, yielding resistances as low as 3 n$\rm Ω$ that are stable over time. The second approach involves inserting indiu…
▽ More
We present two different techniques for achieving low resistance ($<$20 n$\rm Ω$) contacts between copper and aluminium at cryogenic temperatures. The best method is based on gold plating of the surfaces in an e-beam evaporator immediately after Ar plasma etching in the same apparatus, yielding resistances as low as 3 n$\rm Ω$ that are stable over time. The second approach involves inserting indium in the Al/Cu joint. For both methods, we believe key elements are surface polishing, total removal of the aluminum oxide surface layer, and temporary application of large (typ. 11 kN) compression forces. We believe the values for gold plated contacts are the lowest ever reported for a Cu/Al joint of a few $\rm cm^{2}$. This technology could simplify the construction of thermal links for advanced cryogenics applications, in particular that of extremely low resistance heat switches for nuclear demagnetization refrigerators.
△ Less
Submitted 31 March, 2021; v1 submitted 4 September, 2020;
originally announced September 2020.
-
Electric circuit model of microwave optomechanics
Authors:
Xin Zhou,
Dylan Cattiaux,
Didier Theron,
Eddy Collin
Abstract:
We report on the generic classical electric circuit modeling that describes standard single-tone microwave optomechanics. Based on a parallel RLC circuit in which a mechanical oscillator acts as a movable capacitor, derivations of analytical expressions are presented, including key features such as the back-action force, the input-output expressions, and the spectral densities associated, all in t…
▽ More
We report on the generic classical electric circuit modeling that describes standard single-tone microwave optomechanics. Based on a parallel RLC circuit in which a mechanical oscillator acts as a movable capacitor, derivations of analytical expressions are presented, including key features such as the back-action force, the input-output expressions, and the spectral densities associated, all in the classical regime. These expressions coincide with the standard quantum treatment performed in optomechanics when the occupation number of both cavity and mechanical oscillator are large. Besides, the derived analytics transposes optical elements and properties into electronics terms, which is mandatory for quantitative measurement and design purposes. Finally, the direct comparison between the standard quantum treatment and the classical model addresses the bounds between quantum and classical regimes, highlighting the features which are truly quantum, and those which are not.
△ Less
Submitted 27 October, 2020; v1 submitted 28 July, 2020;
originally announced July 2020.
-
Design Evaluation of Serial and Parallel sub-mK Continuous Nuclear Demagnetization Refrigerators
Authors:
D. Schmoranzer,
J. Butterworth,
S. Triqueneaux,
E. Collin,
A. Fefferman
Abstract:
We present the evaluation of two different design configurations of a two-stage PrNi$_5$ continuous nuclear demagnetization refrigerator. Serial and parallel configurations of the two stages are considered, with emphasis on the attainable cooling power at sub-mK temperatures and the impact of the design choices on the operation of the refrigerator. Numerical simulations of heat transfer in the set…
▽ More
We present the evaluation of two different design configurations of a two-stage PrNi$_5$ continuous nuclear demagnetization refrigerator. Serial and parallel configurations of the two stages are considered, with emphasis on the attainable cooling power at sub-mK temperatures and the impact of the design choices on the operation of the refrigerator. Numerical simulations of heat transfer in the setup are used to evaluate the performance of the refrigerator as well as the technological requirements for the essential thermal links. In accord with similar findings for adiabatic demagnetization refrigerators [Shirron, \emph{Cryogenics} \textbf{62}, 2014], our simulations show that the performance of both configurations improves as the thermal links improve, and that the parallel configuration yields a higher cooling power than the series design for a given thermal link resistance and sample temperature.
△ Less
Submitted 22 July, 2020; v1 submitted 3 December, 2019;
originally announced December 2019.
-
A 10 mK hermetic cell for eliminating parasitic heating in cryogen-free dilution refrigerators
Authors:
David Schmoranzer,
Sumit Kumar,
Sébastien Triqueneaux,
Xiao Liu,
Thomas Metcalf,
Glenn Jernigan,
Eddy Collin,
Andrew Fefferman
Abstract:
Cryogen-free dilution refrigerators generally simplify low temperature research but some types of samples, including superconducting qubits and other nanoelectronic devices, are affected by environmental heat sources such as stray photons or residual helium. We present the design and performance of a hermetic cell installed on the mixing chamber plate of a cryogen-free dilution refrigerator. The p…
▽ More
Cryogen-free dilution refrigerators generally simplify low temperature research but some types of samples, including superconducting qubits and other nanoelectronic devices, are affected by environmental heat sources such as stray photons or residual helium. We present the design and performance of a hermetic cell installed on the mixing chamber plate of a cryogen-free dilution refrigerator. The performance was quantified by measuring the dependence of the resonance frequency of a mechanical oscillator installed inside the cell on the mixing chamber temperature down to 10 mK. We found the expected logarithmic temperature dependence of the resonance frequency down to the lowest temperatures, demonstrating that the efficiency of the hermetic shield is significantly better than that of a simpler shield with no visible gaps.
△ Less
Submitted 8 November, 2019;
originally announced November 2019.
-
Niobium nitride thin films for very low temperature resistive thermometry
Authors:
Tuyen Nguyen,
Adib Tavakoli,
Sebastien Triqueneaux,
Rahul Swami,
Aki Ruhtinas,
Jeremy Gradel,
Pablo Garcia-Campos,
Klaus Hasselbach,
Aviad Frydman,
Benjamin Piot,
Mathieu Gibert,
Eddy Collin,
Olivier Bourgeois
Abstract:
We investigate thin film resistive thermometry based on metal-to-insulator-transition (niobium nitride) materials down to very low temperature. The variation of the NbN thermometer resistance have been calibrated versus temperature and magnetic field. High sensitivity in tempertaure variation detection is demonstrated through efficient temperature coefficient of resistance. The nitrogen content of…
▽ More
We investigate thin film resistive thermometry based on metal-to-insulator-transition (niobium nitride) materials down to very low temperature. The variation of the NbN thermometer resistance have been calibrated versus temperature and magnetic field. High sensitivity in tempertaure variation detection is demonstrated through efficient temperature coefficient of resistance. The nitrogen content of the niobium nitride thin films can be tuned to adjust the optimal working temperature range. In the present experiment, we show the versatility of the NbN thin film technology through applications in very different low temperature use-cases. We demonstrate that thin film resistive thermometry can be extended to temperatures below 30 mK with low electrical impedance.
△ Less
Submitted 19 July, 2019;
originally announced July 2019.
-
Cryogenic broadband vibration measurement on a cryogen-free dilution refrigerator
Authors:
D. Schmoranzer,
A. Luck,
E. Collin,
A. Fefferman
Abstract:
This manuscript reports a set of acceleration measurements in the frequency range from 0 to 50 kHz performed at the mixing chamber plate (2 axes) and the top flange (3 axes) of a cryogen-free dilution refrigerator. Various configurations of the support frame and coupling to the pulse tube compressor and motor have been tested, and the dominant contribution in the spectrum of vibrations is located,…
▽ More
This manuscript reports a set of acceleration measurements in the frequency range from 0 to 50 kHz performed at the mixing chamber plate (2 axes) and the top flange (3 axes) of a cryogen-free dilution refrigerator. Various configurations of the support frame and coupling to the pulse tube compressor and motor have been tested, and the dominant contribution in the spectrum of vibrations is located, surprisingly, near 20 kHz. Finally, the efficiency of various precautions in suppressing the observed vibration levels is illustrated.
△ Less
Submitted 16 November, 2018;
originally announced November 2018.
-
Development of a sub-mK Continuous Nuclear Demagnetization Refrigerator
Authors:
David Schmoranzer,
Rasul Gazizulin,
Sébastien Triqueneaux,
Eddy Collin,
Andrew Fefferman
Abstract:
We present the development of a two-stage PrNi$_5$ continuous demagnetization refrigerator at the Institut Néel/CNRS and numerical simulations of its performance. The thermal model used in the simulations is discussed in detail including the likely sources of heating. We demonstrate the effects of the critical thermal links including superconducting heat switches as well as the heat conductivity o…
▽ More
We present the development of a two-stage PrNi$_5$ continuous demagnetization refrigerator at the Institut Néel/CNRS and numerical simulations of its performance. The thermal model used in the simulations is discussed in detail including the likely sources of heating. We demonstrate the effects of the critical thermal links including superconducting heat switches as well as the heat conductivity of the PrNi$_5$, accounting for the dependence of cooling power on the PrNi$_5$ rod diameter. Our simulations show that if extreme care is taken to minimize the thermal resistance between the nuclear stages, a sample temperature of 1~mK can be maintained under a 20~nW heat load.
△ Less
Submitted 3 June, 2020; v1 submitted 20 September, 2018;
originally announced September 2018.
-
Thermal coupling of silicon oscillators in cryogen-free dilution refrigerators
Authors:
David Schmoranzer,
Sumit Kumar,
Annina Luck,
Eddy Collin,
Andrew Fefferman,
Xiao Liu,
Thomas Metcalf,
Glenn Jernigan
Abstract:
Silicon double paddle osillators (DPO) have been successfully used for measuring the elastic properties of amorphous films down to 10 mK (see for example \cite{Fefferman16,Liu14}). Until now, our group has used a wet dilution refrigerator for the lowest temperature measurements. We present measurements carried out on a Bluefors cryogen-free dilution refrigerator that demonstrate an extreme sensiti…
▽ More
Silicon double paddle osillators (DPO) have been successfully used for measuring the elastic properties of amorphous films down to 10 mK (see for example \cite{Fefferman16,Liu14}). Until now, our group has used a wet dilution refrigerator for the lowest temperature measurements. We present measurements carried out on a Bluefors cryogen-free dilution refrigerator that demonstrate an extreme sensitivity of the thermal coupling of the DPO to its environment. These measurements show that it is necessary to enclose the DPO in a shield at the mixing chamber (MXC) temperature. Any gaps in the shield limit its effectiveness, even if there is no line-of-sight path to the DPO. In the absence of a cryogenic hermetic shield surrounding the DPO, turning off the pulse tube while maintaining the MXC and still temperatures leads to heating of the DPO. This demonstrates that any heating of the sample due to pulse tube vibrations is a less important effect.
△ Less
Submitted 19 September, 2018;
originally announced September 2018.
-
Electron - nuclear recoil discrimination by pulse shape analysis
Authors:
J. Elbs,
Yu. M. Bunkov,
E. Collin,
H. Godfrin,
O. Suvorova
Abstract:
In the framework of the ``ULTIMA'' project, we use ultra cold superfluid 3He bolometers for the direct detection of single particle events, aimed for a future use as a dark matter detector. One parameter of the pulse shape observed after such an event is the thermalization time constant. Until now it was believed that this parameter only depends on geometrical factors and superfluid 3He properti…
▽ More
In the framework of the ``ULTIMA'' project, we use ultra cold superfluid 3He bolometers for the direct detection of single particle events, aimed for a future use as a dark matter detector. One parameter of the pulse shape observed after such an event is the thermalization time constant. Until now it was believed that this parameter only depends on geometrical factors and superfluid 3He properties, and that it is independent of the nature of the incident particles. In this report we show new results which demonstrate that a difference for muon- and neutron events, as well as events simulated by heater pulses exist. The possibility to use this difference for event discrimination in a future dark matter detector will be discussed.
△ Less
Submitted 18 October, 2007;
originally announced October 2007.
-
Bolometric calibration of a superfluid $^3$He detector for Dark Matter search: direct measurement of the scintillated energy fraction for neutron, electron and muon events
Authors:
C. B. Winkelmann,
J. Elbs,
Yu. M. Bunkov,
E. Collin,
H. Godfrin,
M. Krusius
Abstract:
We report on the calibration of a superfluid $^3$He bolometer developed for the search of non-baryonic Dark Matter. Precise thermometry is achieved by the direct measurement of thermal excitations using Vibrating Wire Resonators (VWRs). The heating pulses for calibration were produced by the direct quantum process of quasiparticle generation by other VWRs present. The bolometric calibration fact…
▽ More
We report on the calibration of a superfluid $^3$He bolometer developed for the search of non-baryonic Dark Matter. Precise thermometry is achieved by the direct measurement of thermal excitations using Vibrating Wire Resonators (VWRs). The heating pulses for calibration were produced by the direct quantum process of quasiparticle generation by other VWRs present. The bolometric calibration factor is analyzed as a function of temperature and excitation level of the sensing VWR. The calibration is compared to bolometric measurements of the nuclear neutron capture reaction and heat depositions by cosmic muons and low energy electrons. The comparison allows a quantitative estimation of the ultra-violet scintillation rate of irradiated helium, demonstrating the possibility of efficient electron recoil event rejection.
△ Less
Submitted 28 November, 2006;
originally announced November 2006.