Modulations of the Cosmic Muon Signal in Ten Years of Borexino Data
Authors:
The Borexino Collaboration,
M. Agostini,
K. Altenmüller,
S. Appel,
V. Atroshchenko,
Z. Bagdasarian,
D. Basilico,
G. Bellini,
J. Benziger,
D. Bick,
I. Bolognino,
G. Bonfini,
D. Bravo,
B. Caccianiga,
F. Calaprice,
A. Caminata,
S. Caprioli,
M. Carlini,
P. Cavalcante,
F. Cavanna,
A. Chepurnov,
K. Choi,
L. Collica,
D. D'Angelo,
S. Davini
, et al. (91 additional authors not shown)
Abstract:
We have measured the flux of cosmic muons in the Laboratori Nazionali del Gran Sasso at 3800\,m\,w.e. to be $(3.432 \pm 0.003)\cdot 10^{-4}\,\mathrm{{m^{-2}s^{-1}}}$ based on ten years of Borexino data acquired between May 2007 and May 2017. A seasonal modulation with a period of $(366.3 \pm 0.6)\,\mathrm{d}$ and a relative amplitude of $(1.36 \pm0.04)\%$ is observed. The phase is measured to be…
▽ More
We have measured the flux of cosmic muons in the Laboratori Nazionali del Gran Sasso at 3800\,m\,w.e. to be $(3.432 \pm 0.003)\cdot 10^{-4}\,\mathrm{{m^{-2}s^{-1}}}$ based on ten years of Borexino data acquired between May 2007 and May 2017. A seasonal modulation with a period of $(366.3 \pm 0.6)\,\mathrm{d}$ and a relative amplitude of $(1.36 \pm0.04)\%$ is observed. The phase is measured to be $(181.7 \pm 0.4)\,\mathrm{d}$, corresponding to a maximum at the 1$^\mathrm{st}$ of July. Using data inferred from global atmospheric models, we show the muon flux to be positively correlated with the atmospheric temperature and measure the effective temperature coefficient $α_\mathrm{T} = 0.90 \pm 0.02$. The origin of cosmic muons from pion and kaon decays in the atmosphere allows to interpret the effective temperature coefficient as an indirect measurement of the atmospheric kaon-to-pion production ratio $r_{\mathrm{K}/π} = 0.11^{+0.11}_{-0.07}$ for primary energies above $18\,\mathrm{TeV}$. We find evidence for a long-term modulation of the muon flux with a period of $\sim 3000\,\mathrm{d}$ and a maximum in June 2012 that is not present in the atmospheric temperature data. A possible correlation between this modulation and the solar activity is investigated. The cosmogenic neutron production rate is found to show a seasonal modulation in phase with the cosmic muon flux but with an increased amplitude of $(2.6 \pm 0.4)\%$.
△ Less
Submitted 28 January, 2019; v1 submitted 13 August, 2018;
originally announced August 2018.
-
Speeding up complex multivariate data analysis in Borexino with parallel computing based on Graphics Processing Unit
Authors:
X. F. Ding,
M. Agostini,
K. Altenmuller,
S. Appel,
V. Atroshchenko,
Z. Bagdasarian,
D. Basilico,
G. Bellini,
J. Benziger,
D. Bick,
G. Bonfini,
D. Bravo,
B. Caccianiga,
F. Calaprice,
A. Caminata,
S. Caprioli,
M. Carlini,
P. Cavalcante,
A. Chepurnov,
K. Choi,
L. Collica,
D. D'Angelo,
S. Davini,
A. Derbin,
A. Di Ludovico
, et al. (82 additional authors not shown)
Abstract:
A spectral fitter based on the graphics processor unit (GPU) has been developed for Borexino solar neutrino analysis. It is able to shorten the fitting time to a superior level compared to the CPU fitting procedure. In Borexino solar neutrino spectral analysis, fitting usually requires around one hour to converge since it includes time-consuming convolutions in order to account for the detector re…
▽ More
A spectral fitter based on the graphics processor unit (GPU) has been developed for Borexino solar neutrino analysis. It is able to shorten the fitting time to a superior level compared to the CPU fitting procedure. In Borexino solar neutrino spectral analysis, fitting usually requires around one hour to converge since it includes time-consuming convolutions in order to account for the detector response and pile-up effects. Moreover, the convergence time increases to more than two days when including extra computations for the discrimination of $^{11}$C and external $γ$s. In sharp contrast, with the GPU-based fitter it takes less than 10 seconds and less than four minutes, respectively. This fitter is developed utilizing the GooFit project with customized likelihoods, pdfs and infrastructures supporting certain analysis methods. In this proceeding the design of the package, developed features and the comparison with the original CPU fitter are presented.
△ Less
Submitted 28 May, 2018;
originally announced May 2018.
-
Spectral Calibration of the Fluorescence Telescopes of the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin,
G. Avila,
A. M. Badescu,
A. Balaceanu,
F. Barbato,
R. J. Barreira Luz
, et al. (381 additional authors not shown)
Abstract:
We present a novel method to measure precisely the relative spectral response of the fluorescence telescopes of the Pierre Auger Observatory. We used a portable light source based on a xenon flasher and a monochromator to measure the relative spectral efficiencies of eight telescopes in steps of 5 nm from 280 nm to 440 nm. Each point in a scan had approximately 2 nm FWHM out of the monochromator.…
▽ More
We present a novel method to measure precisely the relative spectral response of the fluorescence telescopes of the Pierre Auger Observatory. We used a portable light source based on a xenon flasher and a monochromator to measure the relative spectral efficiencies of eight telescopes in steps of 5 nm from 280 nm to 440 nm. Each point in a scan had approximately 2 nm FWHM out of the monochromator. Different sets of telescopes in the observatory have different optical components, and the eight telescopes measured represent two each of the four combinations of components represented in the observatory. We made an end-to-end measurement of the response from different combinations of optical components, and the monochromator setup allowed for more precise and complete measurements than our previous multi-wavelength calibrations. We find an overall uncertainty in the calibration of the spectral response of most of the telescopes of 1.5% for all wavelengths; the six oldest telescopes have larger overall uncertainties of about 2.2%. We also report changes in physics measureables due to the change in calibration, which are generally small.
△ Less
Submitted 2 October, 2017; v1 submitted 5 September, 2017;
originally announced September 2017.
-
Muon Counting using Silicon Photomultipliers in the AMIGA detector of the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
P. Allison,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
M. Ambrosio,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin,
G. Avila,
A. M. Badescu
, et al. (400 additional authors not shown)
Abstract:
AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is com…
▽ More
AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is composed of three scintillation modules, with a 10 m$^2$ detection area per module. In this paper, a new generation of detectors, replacing the current multi-pixel photomultiplier tube (PMT) with silicon photo sensors (aka. SiPMs), is proposed. The selection of the new device and its front-end electronics is explained. A method to calibrate the counting system that ensures the performance of the detector is detailed. This method has the advantage of being able to be carried out in a remote place such as the one where the detectors are deployed. High efficiency results, i.e. 98 % efficiency for the highest tested overvoltage, combined with a low probability of accidental counting ($\sim$2 %), show a promising performance for this new system.
△ Less
Submitted 4 October, 2017; v1 submitted 17 March, 2017;
originally announced March 2017.
-
Prototype muon detectors for the AMIGA component of the Pierre Auger Observatory
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
P. Allison,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
R. Alves Batista,
M. Ambrosio,
A. Aminaei,
G. A. Anastasi,
L. Anchordoqui,
B. Andrada,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin
, et al. (429 additional authors not shown)
Abstract:
Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to extend its range of detection and to directly measure the muon content of the particle showers. It consists of an infill of surface water-Cherenkov detectors accompanied by buried scintillator detectors used for muon counting. The main objectives of the AMIGA engineering array, referred to as the Unitary…
▽ More
Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory to extend its range of detection and to directly measure the muon content of the particle showers. It consists of an infill of surface water-Cherenkov detectors accompanied by buried scintillator detectors used for muon counting. The main objectives of the AMIGA engineering array, referred to as the Unitary Cell, are to identify and resolve all engineering issues as well as to understand the muon-number counting uncertainties related to the design of the detector. The mechanical design, fabrication and deployment processes of the muon counters of the Unitary Cell are described in this document. These muon counters modules comprise sealed PVC casings containing plastic scintillation bars, wavelength-shifter optical fibers, 64 pixel photomultiplier tubes, and acquisition electronics. The modules are buried approximately 2.25 m below ground level in order to minimize contamination from electromagnetic shower particles. The mechanical setup, which allows access to the electronics for maintenance, is also described in addition to tests of the modules' response and integrity. The completed Unitary Cell has measured a number of air showers of which a first analysis of a sample event is included here.
△ Less
Submitted 12 May, 2016; v1 submitted 5 May, 2016;
originally announced May 2016.
-
Nanosecond-level time synchronization of autonomous radio detector stations for extensive air showers
Authors:
The Pierre Auger Collaboration,
A. Aab,
P. Abreu,
M. Aglietta,
E. J. Ahn,
I. Al Samarai,
I. F. M. Albuquerque,
I. Allekotte,
P. Allison,
A. Almela,
J. Alvarez Castillo,
J. Alvarez-Muñiz,
R. Alves Batista,
M. Ambrosio,
A. Aminaei,
G. A. Anastasi,
L. Anchordoqui,
S. Andringa,
C. Aramo,
F. Arqueros,
N. Arsene,
H. Asorey,
P. Assis,
J. Aublin,
G. Avila
, et al. (426 additional authors not shown)
Abstract:
To exploit the full potential of radio measurements of cosmic-ray air showers at MHz frequencies, a detector timing synchronization within 1 ns is needed. Large distributed radio detector arrays such as the Auger Engineering Radio Array (AERA) rely on timing via the Global Positioning System (GPS) for the synchronization of individual detector station clocks. Unfortunately, GPS timing is expected…
▽ More
To exploit the full potential of radio measurements of cosmic-ray air showers at MHz frequencies, a detector timing synchronization within 1 ns is needed. Large distributed radio detector arrays such as the Auger Engineering Radio Array (AERA) rely on timing via the Global Positioning System (GPS) for the synchronization of individual detector station clocks. Unfortunately, GPS timing is expected to have an accuracy no better than about 5 ns. In practice, in particular in AERA, the GPS clocks exhibit drifts on the order of tens of ns. We developed a technique to correct for the GPS drifts, and an independent method is used for cross-checks that indeed we reach nanosecond-scale timing accuracy by this correction. First, we operate a "beacon transmitter" which emits defined sine waves detected by AERA antennas recorded within the physics data. The relative phasing of these sine waves can be used to correct for GPS clock drifts. In addition to this, we observe radio pulses emitted by commercial airplanes, the position of which we determine in real time from Automatic Dependent Surveillance Broadcasts intercepted with a software-defined radio. From the known source location and the measured arrival times of the pulses we determine relative timing offsets between radio detector stations. We demonstrate with a combined analysis that the two methods give a consistent timing calibration with an accuracy of 2 ns or better. Consequently, the beacon method alone can be used in the future to continuously determine and correct for GPS clock drifts in each individual event measured by AERA.
△ Less
Submitted 15 February, 2016; v1 submitted 7 December, 2015;
originally announced December 2015.