-
Timing resolution performance of Timepix4 bump-bonded assemblies
Authors:
Riccardo Bolzonella,
Jerome Alexandre Alozy,
Rafael Ballabriga,
Martin van Beuzekom,
Nicolò Vladi Biesuz,
Michael Campbell,
Paolo Cardarelli,
Viola Cavallini,
Victor Coco,
Angelo Cotta Ramusino,
Massimiliano Fiorini,
Vladimir Gromov,
Marco Guarise,
Xavier Llopart Cudie,
Shinichi Okamura,
Gabriele Romolini,
Alessandro Saputi,
Arseniy Vitkovskiy
Abstract:
The timing performance of the Timepix4 application-specific integrated circuit (ASIC) bump-bonded to a $100\;μ\textrm{m}$ thick n-on-p silicon sensor is presented. A picosecond pulsed infrared laser was used to generate electron-hole pairs in the silicon bulk in a repeatable fashion, controlling the amount, position and time of the stimulated charge signal. The timing resolution for a single pixel…
▽ More
The timing performance of the Timepix4 application-specific integrated circuit (ASIC) bump-bonded to a $100\;μ\textrm{m}$ thick n-on-p silicon sensor is presented. A picosecond pulsed infrared laser was used to generate electron-hole pairs in the silicon bulk in a repeatable fashion, controlling the amount, position and time of the stimulated charge signal. The timing resolution for a single pixel has been measured to $107\;\textrm{ps}$ r.m.s. for laser-stimulated signals in the silicon sensor bulk. Considering multi-pixel clusters, the measured timing resolution reached $33\;\textrm{ps}$ r.m.s. exploiting oversampling of the timing information over several pixels.
△ Less
Submitted 9 July, 2024; v1 submitted 23 April, 2024;
originally announced April 2024.
-
The LHCb VELO Upgrade Module Construction
Authors:
K. Akiba,
M. Alexander,
C. Bertella,
A. Biolchini,
A. Bitadze,
G. Bogdanova,
S. Borghi,
T. J. V. Bowcock,
K. Bridges,
M. Brock,
A. T. Burke,
J. Buytaert,
W. Byczynski,
J. Carroll,
V. Coco,
P. Collins,
A. Davis,
O. De Aguiar Francisco,
K. De Bruyn,
S. De Capua,
K. De Roo,
F. Doherty,
L. Douglas,
L. Dufour,
R. Dumps
, et al. (62 additional authors not shown)
Abstract:
The LHCb detector has undergone a major upgrade for LHC Run 3. This Upgrade I detector facilitates operation at higher luminosity and utilises full-detector information at the LHC collision rate, critically including the use of vertex information. A new vertex locator system, the VELO Upgrade, has been constructed. The core element of the new VELO are the double-sided pixelated hybrid silicon dete…
▽ More
The LHCb detector has undergone a major upgrade for LHC Run 3. This Upgrade I detector facilitates operation at higher luminosity and utilises full-detector information at the LHC collision rate, critically including the use of vertex information. A new vertex locator system, the VELO Upgrade, has been constructed. The core element of the new VELO are the double-sided pixelated hybrid silicon detector modules which operate in vacuum close to the LHC beam in a high radiation environment. The construction and quality assurance tests of these modules are described in this paper. The modules incorporate 200 \mum thick, n-on-p silicon sensors bump-bonded to 130 \nm technology ASICs. These are attached with high precision to a silicon microchannel substrate that uses evaporative CO$_2$ cooling. The ASICs are controlled and read out with flexible printed circuits that are glued to the substrate and wire-bonded to the chips. The mechanical support of the module is given by a carbon fibre plate, two carbon fibre rods and an aluminium plate. The sensor attachment was achieved with an average precision of 21 $\mathrm{μm}$, more than 99.5\% of all pixels are fully functional, and a thermal figure of merit of 3 \mathrm{Kcm^{2}W^{-1}}$ was achieved. The production of the modules was successfully completed in 2021, with the final assembly and installation completed in time for data taking in 2022.
△ Less
Submitted 21 April, 2024;
originally announced April 2024.
-
Considerations on time resolution of neutron irradiated single pixel 3D structures at fuences up to $10^{17}$ n$_{eq}$/cm$^{2}$ using 120 GeV SPS pion beams
Authors:
Evangelos-Leonidas Gkougkousis,
Edgar Lemos Cid,
Viktor Coco
Abstract:
The proven radiation hardness of silicon 3D devices up to fluences of $1 {\times} 10^{17}$ $n_{eq}/cm^{2}$ makes them an excellent choice for next generation trackers, providing < 10 $μm$ position resolution at a high multiplicity environment. The anticipated pile-up increase at HL-LHC conditions and beyond, requires the addition of < 50 ps per hit timing information to successfully resolve displa…
▽ More
The proven radiation hardness of silicon 3D devices up to fluences of $1 {\times} 10^{17}$ $n_{eq}/cm^{2}$ makes them an excellent choice for next generation trackers, providing < 10 $μm$ position resolution at a high multiplicity environment. The anticipated pile-up increase at HL-LHC conditions and beyond, requires the addition of < 50 ps per hit timing information to successfully resolve displaced and primary vertices. In this study, the timing performance, uniformity and efficiency of neutron and proton irradiated single pixel 3D devices is discussed. Fluences up to $1 {\times} 10^{17}$ $n_{eq}/cm^{2}$ in three different geometrical implementations are evaluated using 120 GeV SPS pion beams. A MIMOSA-26 type telescope is used to provide detailed tracking information with a ~ 5 $μm$ position resolution. Productions with single- and double-sided processes, yielding active thicknesses of 130 and 230 $μm$ respectively, are examined with varied pixel sizes from $55 {\times} 55$ $μm^{2}$ to $25 {\times} 100$ $μm^{2}$ and a comparative study of field uniformity is presented with respect to electrode geometry. The question of electronics bandwidth is extensively addressed with respect to achievable time resolution, efficiency and collected charge, forming a 3D phase space to which an appropriate operating point can be selected depending on the application requirements.
△ Less
Submitted 4 March, 2024; v1 submitted 1 March, 2024;
originally announced March 2024.
-
Fabrication of a Silicon Electron Multiplier sensor using Metal Assisted Chemical Etching and its characterisation
Authors:
Marius Mæhlum Halvorsen,
Victor Coco,
Paula Collins,
Heidi Sandaker,
Lucia Romano
Abstract:
The Silicon Electron Multiplier (SiEM) sensor is a novel sensor concept that enables charge multiplication by high electric fields generated by embedded metal electrodes within the sensor bulk. Metal assisted chemical etching (MacEtch) in gas phase with platinum as a catalyst has been used to fabricate test structures consisting of vertically aligned silicon pillars and strips on top of a silicon…
▽ More
The Silicon Electron Multiplier (SiEM) sensor is a novel sensor concept that enables charge multiplication by high electric fields generated by embedded metal electrodes within the sensor bulk. Metal assisted chemical etching (MacEtch) in gas phase with platinum as a catalyst has been used to fabricate test structures consisting of vertically aligned silicon pillars and strips on top of a silicon bulk. The pillars exceed 10 $μm$ in height with a diameter of 1.0 $μm$ and are arranged as a hexagonal lattice with a pitch of 1.5 $μm$. Electrical characterisations through current $-$ voltage measurements inside a scanning electron microscope and a climate chamber have demonstrated that the MacEtch process is compatible with active media and p-n junctions.
△ Less
Submitted 27 August, 2023;
originally announced August 2023.
-
The LHCb upgrade I
Authors:
LHCb collaboration,
R. Aaij,
A. S. W. Abdelmotteleb,
C. Abellan Beteta,
F. Abudinén,
C. Achard,
T. Ackernley,
B. Adeva,
M. Adinolfi,
P. Adlarson,
H. Afsharnia,
C. Agapopoulou,
C. A. Aidala,
Z. Ajaltouni,
S. Akar,
K. Akiba,
P. Albicocco,
J. Albrecht,
F. Alessio,
M. Alexander,
A. Alfonso Albero,
Z. Aliouche,
P. Alvarez Cartelle,
R. Amalric,
S. Amato
, et al. (1298 additional authors not shown)
Abstract:
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their select…
▽ More
The LHCb upgrade represents a major change of the experiment. The detectors have been almost completely renewed to allow running at an instantaneous luminosity five times larger than that of the previous running periods. Readout of all detectors into an all-software trigger is central to the new design, facilitating the reconstruction of events at the maximum LHC interaction rate, and their selection in real time. The experiment's tracking system has been completely upgraded with a new pixel vertex detector, a silicon tracker upstream of the dipole magnet and three scintillating fibre tracking stations downstream of the magnet. The whole photon detection system of the RICH detectors has been renewed and the readout electronics of the calorimeter and muon systems have been fully overhauled. The first stage of the all-software trigger is implemented on a GPU farm. The output of the trigger provides a combination of totally reconstructed physics objects, such as tracks and vertices, ready for final analysis, and of entire events which need further offline reprocessing. This scheme required a complete revision of the computing model and rewriting of the experiment's software.
△ Less
Submitted 17 May, 2023;
originally announced May 2023.
-
Reconstruction of charged tracks with Timepix4 ASICs
Authors:
Kazu Akiba,
Martin van Beuzekom,
Vincent van Beveren,
Wiktor Byczynski,
Victor Coco,
Paula Collins,
Elena Dall'Occo,
Raphael Dumps,
Tim Evans,
Robbert Geertsema,
Evangelios Gkougkousis,
Marius Halvorsen,
Bas van der Heijden,
Kevin Heijhoff,
Edgar Lemos Cid,
Tommaso Pajero,
David Rolf,
Heinrich Schindler
Abstract:
The design of a detector system comprised of four silicon sensors bump-bonded to Timepix4 ASICs is described together with its data acquisition system, operational infrastructure, and dedicated software. The spatial and temporal performance of the system are assessed with a 180 GeV/c mixed hadron beam at the CERN SPS and reported in detail. Particle tracks are reconstructed using time-space measur…
▽ More
The design of a detector system comprised of four silicon sensors bump-bonded to Timepix4 ASICs is described together with its data acquisition system, operational infrastructure, and dedicated software. The spatial and temporal performance of the system are assessed with a 180 GeV/c mixed hadron beam at the CERN SPS and reported in detail. Particle tracks are reconstructed using time-space measurements from the four detector planes. The spatial hit resolution is assessed to be $(15.5\pm 0.5)$ $μ$m and $(4.5\pm0.3)$ $μ$m for 100 and 300 $μ$m thick sensors, respectively. The timestamps from the detectors are also measured with fine precision, yielding time resolutions of $(452\pm10)$ ps, $(420\pm10)$ ps, $(639\pm10)$ ps, $(631\pm10)$ ps for the two 100 and two 300 $μ$m thick sensors respectively. These measurements are combined to a track time resolution of $(340\pm 5)$ ps.
△ Less
Submitted 23 December, 2022; v1 submitted 4 October, 2022;
originally announced October 2022.
-
The Silicon Electron Multiplier Sensor
Authors:
Marius Mæhlum Halvorsen,
Victor Coco,
Evangelos Leonidas Gkougkousis,
Paula Collins,
Olivier Girard
Abstract:
The Silicon Electron Multiplier (SiEM) is a novel sensor concept for minimum ionizing particle (MIP) detection which uses internal gain and fine pitch to achieve excellent temporal and spatial resolution. In contrast to sensors where the gain region is induced by do** (LGADs, APDs), amplification in the SiEM is achieved by applying an electric potential difference in a composite electrode struct…
▽ More
The Silicon Electron Multiplier (SiEM) is a novel sensor concept for minimum ionizing particle (MIP) detection which uses internal gain and fine pitch to achieve excellent temporal and spatial resolution. In contrast to sensors where the gain region is induced by do** (LGADs, APDs), amplification in the SiEM is achieved by applying an electric potential difference in a composite electrode structure embedded within the silicon bulk using MEMS fabrication techniques. Since no gain-layer deactivation is expected with radiation damage, such a structure is expected to withstand fluences of up to $10^{16} n_{eq}$. Various geometries and biasing configurations are studied, within the boundaries imposed by the fabrication process being considered. The effective gain, the field in the sensor, the leakage current and breakdown conditions are studied for cell sizes in the range of $6 - 15 μm$. Simulations show that gains in excess of 10 can be achieved, and studies of the time structure of the induced signals from a charge cloud deposited in the middle of the sensor show that time resolutions similar to other sensors with internal gain can be expected. Plans for the manufacture of a proof-of-concept sensor and for its subsequent characterisation are discussed.
△ Less
Submitted 2 March, 2022;
originally announced March 2022.
-
Microchannel cooling for the LHCb VELO Upgrade I
Authors:
Oscar Augusto De Aguiar Francisco,
Wiktor Byczynski,
Kazu Akiba,
Claudia Bertella,
Alexander Bitadze,
Matthew Brock,
Bartosz Bulat,
Guillaume Button,
Jan Buytaert,
Stefano De Capua,
Riccardo Callegari,
Christine Castellana,
Andrea Catinaccio,
Catherine Charrier,
Collette Charvet,
Victor Coco,
Paula Collins,
Jordan Degrange,
Raphael Dumps,
Diego Alvarez Feito,
Julian Freestone,
Mariusz Jedrychowski,
Vinicius Franco Lima,
Abraham Gallas,
Wouter Hulsbergen
, et al. (35 additional authors not shown)
Abstract:
The LHCb VELO Upgrade I, currently being installed for the 2022 start of LHC Run 3, uses silicon microchannel coolers with internally circulating bi-phase \cotwo for thermal control of hybrid pixel modules operating in vacuum. This is the largest scale application of this technology to date. Production of the microchannel coolers was completed in July 2019 and the assembly into cooling structures…
▽ More
The LHCb VELO Upgrade I, currently being installed for the 2022 start of LHC Run 3, uses silicon microchannel coolers with internally circulating bi-phase \cotwo for thermal control of hybrid pixel modules operating in vacuum. This is the largest scale application of this technology to date. Production of the microchannel coolers was completed in July 2019 and the assembly into cooling structures was completed in September 2021. This paper describes the R\&D path supporting the microchannel production and assembly and the motivation for the design choices. The microchannel coolers have excellent thermal peformance, low and uniform mass, no thermal expansion mismatch with the ASICs and are radiation hard. The fluidic and thermal performance is presented.
△ Less
Submitted 23 December, 2021;
originally announced December 2021.
-
Comprehensive technology study of radiation hard LGADs
Authors:
E. L. Gkougkousis,
L. Castillo Garcia,
S. Grinstein,
V. Coco
Abstract:
Towards radiation tolerant sensors for pico-second timing, several dopants are explored. Using a common mask, CNM produced LGADs with boron, boron + carbon and gallium implanted gain layers are studied under neutron and proton irradiation. With fluences ranging from $10^{14}$ to $6\times 10^{15} n_{eq}/cm^{2}$ on both particle species, reported results focus on acceptor removal and gain reduction…
▽ More
Towards radiation tolerant sensors for pico-second timing, several dopants are explored. Using a common mask, CNM produced LGADs with boron, boron + carbon and gallium implanted gain layers are studied under neutron and proton irradiation. With fluences ranging from $10^{14}$ to $6\times 10^{15} n_{eq}/cm^{2}$ on both particle species, reported results focus on acceptor removal and gain reduction via electrical characterization. Timing performance, charge collection, gain and relative efficiency are treated through charged particle measurements, including signal analysis and noise characterization. An accent is placed on stability, via dark rate and operating voltage studies while, radiation related gain reduction mechanisms are examined comparing gain estimations through different approaches.
△ Less
Submitted 17 September, 2022; v1 submitted 12 November, 2021;
originally announced November 2021.
-
Calibration and performance of the LHCb calorimeters in Run 1 and 2 at the LHC
Authors:
C. Abellán Beteta,
A. Alfonso Albero,
Y. Amhis,
S. Barsuk,
C. Beigbeder-Beau,
I. Belyaev,
R. Bonnefoy,
D. Breton,
O. Callot,
M. Calvo Gomez,
A. Camboni,
H. Chanal,
D. Charlet,
M. Chefdeville,
V. Coco,
E. Cogneras,
A. Comerma-Montells,
S. Coquereau,
O. Deschamps,
F. Domingo Bonal,
C. Drancourt,
O. Duarte,
N. Dumont Dayot,
R. Dzhelyadin,
V. Egorychev
, et al. (62 additional authors not shown)
Abstract:
The calibration and performance of the LHCb Calorimeter system in Run 1 and 2 at the LHC are described. After a brief description of the sub-detectors and of their role in the trigger, the calibration methods used for each part of the system are reviewed. The changes which occurred with the increase of beam energy in Run 2 are explained. The performances of the calorimetry for $γ$ and $π^0$ are de…
▽ More
The calibration and performance of the LHCb Calorimeter system in Run 1 and 2 at the LHC are described. After a brief description of the sub-detectors and of their role in the trigger, the calibration methods used for each part of the system are reviewed. The changes which occurred with the increase of beam energy in Run 2 are explained. The performances of the calorimetry for $γ$ and $π^0$ are detailed. A few results from collisions recorded at $\sqrt {s}$ = 7, 8 and 13 TeV are shown.
△ Less
Submitted 26 August, 2020;
originally announced August 2020.
-
The HEV Ventilator
Authors:
J. Buytaert,
A. Abed Abud,
P. Allport,
A. Pazos Álvarez,
K. Akiba,
O. Augusto de Aguiar Francisco,
A. Bay,
F. Bernard,
S. Baron,
C. Bertella,
J. Brunner,
T. Bowcock,
M. Buytaert-De Jode,
W. Byczynski,
R. De Carvalho,
V. Coco,
P. Collins,
R. Collins,
N. Dikic,
N. Dousse,
B. Dowd,
R. Dumps,
P. Durante,
W. Fadel,
S. Farry
, et al. (49 additional authors not shown)
Abstract:
HEV is a low-cost, versatile, high-quality ventilator, which has been designed in response to the COVID-19 pandemic. The ventilator is intended to be used both in and out of hospital intensive care units, and for both invasive and non-invasive ventilation. The hardware can be complemented with an external turbine for use in regions where compressed air supplies are not reliably available. The stan…
▽ More
HEV is a low-cost, versatile, high-quality ventilator, which has been designed in response to the COVID-19 pandemic. The ventilator is intended to be used both in and out of hospital intensive care units, and for both invasive and non-invasive ventilation. The hardware can be complemented with an external turbine for use in regions where compressed air supplies are not reliably available. The standard modes provided include PC-A/C(Pressure Assist Control),PC-A/C-PRVC(Pressure Regulated Volume Control), PC-PSV (Pressure Support Ventilation) and CPAP (Continuous Positive airway pressure). HEV is designed to support remote training and post market surveillance via a web interface and data logging to complement the standard touch screen operation, making it suitable for a wide range of geographical deployment. The HEV design places emphasis on the quality of the pressure curves and the reactivity of the trigger, delivering a global performance which will be applicable to ventilator needs beyond theCOVID-19 pandemic. This article describes the conceptual design and presents the prototype units together with their performance evaluation.
△ Less
Submitted 23 July, 2020;
originally announced July 2020.
-
The Upgrade I of LHCb VELO -- towards an intelligent monitoring platform
Authors:
P. Kopciewicz,
T. Szumlak,
M. Majewski,
K. Akiba,
O. Augusto,
J. Back,
D. S. Bobulska,
G. Bogdanova,
S. Borghi,
T. Bowcock,
J. Buytaert,
E. Lemos Cid,
V. Coco,
P. Collins,
E. Dall'Occo,
K. de Bruyn,
S. de Capua,
F. Dettori,
K. Dreimanis,
D. Dutta,
L. Eklund,
T. Evans,
M. Ferro-Luzzi W. Funk,
L. Meyer Garcia,
O. Boente García
, et al. (41 additional authors not shown)
Abstract:
The Large Hadron Collider beauty (LHCb) detector is designed to detect decays of b- and c- hadrons for the study of CP violation and rare decays. At the end of the LHC Run 2, many of the LHCb measurements remained statistically dominated. In order to increase the trigger yield for purely hadronic channels, the hardware trigger will be removed, and the detector will be read out at 40 MHz. This, in…
▽ More
The Large Hadron Collider beauty (LHCb) detector is designed to detect decays of b- and c- hadrons for the study of CP violation and rare decays. At the end of the LHC Run 2, many of the LHCb measurements remained statistically dominated. In order to increase the trigger yield for purely hadronic channels, the hardware trigger will be removed, and the detector will be read out at 40 MHz. This, in combination with the five-fold increase in luminosity, requires radical changes to LHCb's electronics, and, in some cases, the replacement of entire sub-detectors with state-of-the-art detector technologies. The Vertex Locator (VELO) surrounding the interaction region is used to reconstruct the collision points (primary vertices) and decay vertices of long-lived particles (secondary vertices). The upgraded VELO will be composed of 52 modules placed along the beam axis divided into two retractable halves. The modules will each be equipped with 4 silicon hybrid pixel tiles, each read out by 3 VeloPix ASICs. The total output data rate anticipated for the whole detector will be around 1.6 Tbit/s. The highest occupancy ASICs will have pixel hit rates of approximately 900 Mhit/s, with the corresponding output data rate of 15 Gbit/s. The LHCb upgrade detector will be the first detector to read out at the full LHC rate of 40 MHz. The VELO upgrade will utilize the latest detector technologies to read out at this rate while maintaining the required radiation-hard profile and minimizing the detector material.
△ Less
Submitted 22 July, 2022; v1 submitted 16 June, 2020;
originally announced June 2020.
-
The HEV Ventilator Proposal
Authors:
J. Buytaert,
A. Abed Abud,
K. Akiba,
A. Bay,
C. Bertella,
T. Bowcock,
W. Byczynski,
V. Coco,
P. Collins,
O. Augusto De Aguiar Francisco,
N. Dikic,
R. Dumps,
P. Durante,
A. Fernández Prieto,
V. Franco Lima,
R. Guida,
K. Hennessy,
D. Hutchcroft,
S. Ilic,
A. Jevtic,
K. Kapusniak,
E. Lemos Cid,
J. Lindner,
M. Milovanovic,
D. Murray
, et al. (6 additional authors not shown)
Abstract:
We propose the design of a ventilator which can be easily manufactured and integrated into the hospital environment to support COVID-19 patients. The unit is designed to support standard ventilator modes of operation, most importantly PRVC (Pressure Regulated Volume Control) and SIMV-PC (Synchronised Intermittent Mandatory Ventilation) modes. The unit is not yet an approved medical device and is i…
▽ More
We propose the design of a ventilator which can be easily manufactured and integrated into the hospital environment to support COVID-19 patients. The unit is designed to support standard ventilator modes of operation, most importantly PRVC (Pressure Regulated Volume Control) and SIMV-PC (Synchronised Intermittent Mandatory Ventilation) modes. The unit is not yet an approved medical device and is in the concept and prototy** stage. It is presented here to invite fast feedback for development and deployment in the face of the COVID-19 pandemic.
△ Less
Submitted 2 April, 2020; v1 submitted 1 April, 2020;
originally announced April 2020.
-
Background studies for the CODEX-b experiment: measurements and simulation
Authors:
Biplab Dey,
Jongho Lee,
Victor Coco,
Chang-Seong Moon
Abstract:
This report presents results from a background measurement campaign for the CODEX-b proposal undertaken in August, 2018. The data were recorded in the DELPHI side of the LHCb cavern behind a 3.2~m concrete shield wall, during Run~2 proton-proton collisions with the goal of calibrating the simulation for the full CODEX-b detector. The maximum flux rate in the DELPHI side of the cavern was found to…
▽ More
This report presents results from a background measurement campaign for the CODEX-b proposal undertaken in August, 2018. The data were recorded in the DELPHI side of the LHCb cavern behind a 3.2~m concrete shield wall, during Run~2 proton-proton collisions with the goal of calibrating the simulation for the full CODEX-b detector. The maximum flux rate in the DELPHI side of the cavern was found to be around 0.6~mHz/cm$^2$ across a vertical plane just behind the shield wall, parallel to the beam line. A detailed simulation under development within the LHCb {\tt Gauss} framework is described. This includes shielding elements pertinent for CODEX-b's acceptance -- the LHCb detector, the shield wall and cavern infrastructure. Additional flux from tracks not in the line of sight from the interaction point, but bent by the magnetic fields, are incorporated. Overall, the simulation overestimates the background flux compared to the measurement. Several cross-checks and avenues for further investigations are described.
△ Less
Submitted 19 December, 2020; v1 submitted 8 December, 2019;
originally announced December 2019.
-
Characterisation of a large area silicon photomultiplier
Authors:
A. Nagai,
C. Alispach,
A. Barbano,
V. Coco,
D. della Volpe,
M. Heller,
T. Montaruli,
S. Njoh,
Y. Renier,
I. Troyano-Pujadas
Abstract:
This work illustrates and compares some methods to measure the most relevant parameters of silicon photo-multipliers (\sipm{}s), such as photon detection efficiency as a function of over-voltage and wavelength, dark count rate, optical cross-talk, afterpulse probability. For the measurement of the breakdown voltage, $V_{BD}$, several methods using the current-voltage $IV$ curve are compared, such…
▽ More
This work illustrates and compares some methods to measure the most relevant parameters of silicon photo-multipliers (\sipm{}s), such as photon detection efficiency as a function of over-voltage and wavelength, dark count rate, optical cross-talk, afterpulse probability. For the measurement of the breakdown voltage, $V_{BD}$, several methods using the current-voltage $IV$ curve are compared, such as the "IV Model", the "relative logarithmic derivative", the "inverse logarithmic derivative", the "second logarithmic derivative", and the "third derivative" models. We also show how some of these characteristics can be quite well described by few parameters and allow, for example, to build a function of the wavelength and over-voltage describing the photodetection efficiency. This is fundamental to determine the working point of SiPMs in applications where external factors can affect it.
These methods are applied to the large area monolithic hexagonal SiPM S10943-2832(X), developed in collaboration with Hamamatsu and adopted for a camera for a gamma-ray telescope, called the SST-1M. We describe the measurements of the performance at room temperature of this device. The methods used here can be applied to any other device and the physics background discussed here are quite general and valid for a large phase-space of the parameters.
△ Less
Submitted 9 January, 2020; v1 submitted 4 October, 2018;
originally announced October 2018.
-
Map** the material in the LHCb vertex locator using secondary hadronic interactions
Authors:
M. Alexander,
W. Barter,
A. Bay,
L. J. Bel,
M. van Beuzekom,
G. Bogdanova,
S. Borghi,
T. J. V. Bowcock,
E. Buchanan,
J. Buytaert,
K. Carvalho Akiba,
S. Chen,
V. Coco,
P. Collins,
A. Crocombe,
F. Da Cunha Marinho,
E. Dall'Occo,
S. De Capua,
C. T. Dean,
F. Dettori,
D. Dossett,
K. Dreimanis,
G. Dujany,
L. Eklund,
T. Evans
, et al. (41 additional authors not shown)
Abstract:
Precise knowledge of the location of the material in the LHCb vertex locator (VELO) is essential to reducing background in searches for long-lived exotic particles, and in identifying jets that originate from beauty and charm quarks. Secondary interactions of hadrons produced in beam-gas collisions are used to map the location of material in the VELO. Using this material map, along with properties…
▽ More
Precise knowledge of the location of the material in the LHCb vertex locator (VELO) is essential to reducing background in searches for long-lived exotic particles, and in identifying jets that originate from beauty and charm quarks. Secondary interactions of hadrons produced in beam-gas collisions are used to map the location of material in the VELO. Using this material map, along with properties of a reconstructed secondary vertex and its constituent tracks, a $p$-value can be assigned to the hypothesis that the secondary vertex originates from a material interaction. A validation of this procedure is presented using photon conversions to dimuons.
△ Less
Submitted 18 June, 2018; v1 submitted 20 March, 2018;
originally announced March 2018.
-
The HeRSCheL detector: high-rapidity shower counters for LHCb
Authors:
K. Carvalho Akiba,
F. Alessio,
N. Bondar,
W. Byczynski,
V. Coco,
P. Collins,
R. Dumps,
R. Dzhelyadin,
P. Gandini,
B. R. Gruberg Cazon,
R. Jacobsson,
D. Johnson,
J. Manthey,
J. Mauricio,
R. McNulty,
S. Monteil,
B. Rachwal,
M. Ravonel Salzgeber,
L. Roy,
H. Schindler,
S. Stevenson,
G. Wilkinson
Abstract:
The HeRSCheL detector consists of a set of scintillating counters, designed to increase the coverage of the LHCb experiment in the high-rapidity regions on either side of the main spectrometer. The new detector improves the capabilities of LHCb for studies of diffractive interactions, most notably Central Exclusive Production. In this paper the construction, installation, commissioning, and perfor…
▽ More
The HeRSCheL detector consists of a set of scintillating counters, designed to increase the coverage of the LHCb experiment in the high-rapidity regions on either side of the main spectrometer. The new detector improves the capabilities of LHCb for studies of diffractive interactions, most notably Central Exclusive Production. In this paper the construction, installation, commissioning, and performance of HeRSCheL are presented.
△ Less
Submitted 4 June, 2018; v1 submitted 12 January, 2018;
originally announced January 2018.
-
SENSE: A comparison of photon detection efficiency and optical crosstalk of various SiPM devices
Authors:
A. Nagai,
C. Alispach,
T. Berghöfer,
G. Bonanno,
V. Coco,
D. della Volpe,
A. Haungs,
M. Heller,
K. Henjes-Kunst,
R. Mirzoyan,
T. Montaruli,
G. Romeo,
Y. Renier,
H. C. Schultz-Coulon,
W. Shen,
D. Strom,
H. Tajima,
I. Troyano-Pujadas
Abstract:
This paper describes a comparison of photon detection efficiency and optical crosstalk measurements performed by three partners: Geneva University, Catania Observatory and Nagoya University. The measurements were compared for three different SiPM devices with different active areas: from 9 $mm^2$ up to 93.6 $mm^2$ produced by Hamamatsu. The objective of this work is to establish the measurements a…
▽ More
This paper describes a comparison of photon detection efficiency and optical crosstalk measurements performed by three partners: Geneva University, Catania Observatory and Nagoya University. The measurements were compared for three different SiPM devices with different active areas: from 9 $mm^2$ up to 93.6 $mm^2$ produced by Hamamatsu. The objective of this work is to establish the measurements and analysis procedures for calculating the main SiPM parameters and their precision. This work was done in the scope of SENSE project which aims to build roadmap for the last developments in field of sensors for low light level detection.
△ Less
Submitted 26 February, 2019; v1 submitted 11 December, 2017;
originally announced December 2017.
-
Performance of the LHCb Outer Tracker
Authors:
LHCb Outer Tracker group,
R. Arink,
S. Bachmann,
Y. Bagaturia,
H. Band,
Th. Bauer,
A. Berkien,
Ch. Färber,
A. Bien,
J. Blouw,
L. Ceelie,
V. Coco,
M. Deckenhoff,
Z. Deng,
F. Dettori,
D. van Eijk,
R. Ekelhof,
E. Gersabeck,
L. Grillo,
W. D. Hulsbergen,
T. M. Karbach,
R. Koopman,
A. Kozlinskiy,
Ch. Langenbruch,
V. Lavrentyev
, et al. (30 additional authors not shown)
Abstract:
The LHCb Outer Tracker is a gaseous detector covering an area of 5x6 m2 with 12 double layers of straw tubes. The detector with its services are described together with the commissioning and calibration procedures. Based on data of the first LHC running period from 2010 to 2012, the performance of the readout electronics and the single hit resolution and efficiency are presented. The efficiency to…
▽ More
The LHCb Outer Tracker is a gaseous detector covering an area of 5x6 m2 with 12 double layers of straw tubes. The detector with its services are described together with the commissioning and calibration procedures. Based on data of the first LHC running period from 2010 to 2012, the performance of the readout electronics and the single hit resolution and efficiency are presented. The efficiency to detect a hit in the central half of the straw is estimated to be 99.2%, and the position resolution is determined to be approximately 200 um. The Outer Tracker received a dose in the hottest region corresponding to 0.12 C/cm, and no signs of gain deterioration or other ageing effects are observed.
△ Less
Submitted 22 January, 2014; v1 submitted 15 November, 2013;
originally announced November 2013.
-
Absolute luminosity measurements with the LHCb detector at the LHC
Authors:
The LHCb Collaboration,
R. Aaij,
B. Adeva,
M. Adinolfi,
C. Adrover,
A. Affolder,
Z. Ajaltouni,
J. Albrecht,
F. Alessio,
M. Alexander,
G. Alkhazov,
P. Alvarez Cartelle,
A. A. Alves Jr,
S. Amato,
Y. Amhis,
J. Anderson,
R. B. Appleby,
O. Aquines Gutierrez,
F. Archilli,
L. Arrabito,
A. Artamonov,
M. Artuso,
E. Aslanides,
G. Auriemma,
S. Bachmann
, et al. (549 additional authors not shown)
Abstract:
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-prot…
▽ More
Absolute luminosity measurements are of general interest for colliding-beam experiments at storage rings. These measurements are necessary to determine the absolute cross-sections of reaction processes and are valuable to quantify the performance of the accelerator. Using data taken in 2010, LHCb has applied two methods to determine the absolute scale of its luminosity measurements for proton-proton collisions at the LHC with a centre-of-mass energy of 7 TeV. In addition to the classic "van der Meer scan" method a novel technique has been developed which makes use of direct imaging of the individual beams using beam-gas and beam-beam interactions. This beam imaging method is made possible by the high resolution of the LHCb vertex detector and the close proximity of the detector to the beams, and allows beam parameters such as positions, angles and widths to be determined. The results of the two methods have comparable precision and are in good agreement. Combining the two methods, an overall precision of 3.5% in the absolute luminosity determination is reached. The techniques used to transport the absolute luminosity calibration to the full 2010 data-taking period are presented.
△ Less
Submitted 11 January, 2012; v1 submitted 13 October, 2011;
originally announced October 2011.