-
Performance of the LHCb RICH detectors during LHC Run 2
Authors:
R. Calabrese,
M. Fiorini,
E. Luppi,
L. Minzoni,
I. Slazyk,
L. Tomassetti,
M. Bartolini,
R. Cardinale,
F. Fontanelli,
A. Petrolini,
A. Pistone,
M. Calvi,
C. Matteuzzi,
A. Lupato,
G. Simi,
M. Kucharczyk,
B. Malecki,
M. Witek,
S. Benson,
M. Blago,
G. Cavallero,
A. Contu,
C. D'Ambrosio,
C. Frei,
T. Gys
, et al. (57 additional authors not shown)
Abstract:
The performance of the ring-imaging Cherenkov detectors at the LHCb experiment is determined during the LHC Run 2 period between 2015 and 2018. The stability of the Cherenkov angle resolution and number of detected photons with time and running conditions is measured. The particle identification performance is evaluated with data and found to satisfy the requirements of the physics programme.
The performance of the ring-imaging Cherenkov detectors at the LHCb experiment is determined during the LHC Run 2 period between 2015 and 2018. The stability of the Cherenkov angle resolution and number of detected photons with time and running conditions is measured. The particle identification performance is evaluated with data and found to satisfy the requirements of the physics programme.
△ Less
Submitted 26 May, 2022;
originally announced May 2022.
-
Universal pulses for homogeneous excitation using single channel coils
Authors:
Ronald Mooiweer,
Ian A. Clark,
Eleanor A. Maguire,
Martina F. Callaghan,
Jospeh V. Hajnal,
Shaihan J. Malik
Abstract:
Purpose: Universal Pulses (UPs) are excitation pulses that reduce the flip angle inhomogeneity in high field MRI systems without subject-specific optimization, originally developed for parallel transmit (PTX) systems at 7T. We investigated the potential benefits of UPs for single channel (SC) transmit systems at 3T, which are widely used for clinical and research imaging, and for which flip angle…
▽ More
Purpose: Universal Pulses (UPs) are excitation pulses that reduce the flip angle inhomogeneity in high field MRI systems without subject-specific optimization, originally developed for parallel transmit (PTX) systems at 7T. We investigated the potential benefits of UPs for single channel (SC) transmit systems at 3T, which are widely used for clinical and research imaging, and for which flip angle inhomogeneity can still be problematic.
Methods: SC-UPs were designed using a spiral nonselective k-space trajectory for brain imaging at 3T using transmit field maps (B1+) and off-resonance maps (B0) acquired on two different scanner types: a 'standard' single channel transmit system and a system with a PTX body coil. The effect of training group size was investigated using data (200 subjects) from the standard system. The PTX system was used to compare SC-UPs to PTX-UPs (15 subjects). In two additional subjects, prospective imaging using SC-UP was studied.
Results: Average flip angle error fell from 9.5+/-0.5% for 'default' excitation to 3.0+/-0.6% using SC-UPs trained over 50 subjects. Performance of the UPs was found to steadily improve as training group size increased, but stabilized after ~15 subjects. On the PTX-enabled system, SC-UPs again outperformed default excitation in simulations (4.8+/-0.6% error versus 10.6+/-0.8% respectively) though greater homogenization could be achieved with PTX-UPs (3.9+/-0.6%) and personalized pulses (SC-PP 3.6+/-1.0%, PTX-PP 2.9+/-0.6%). MP-RAGE imaging using SC-UP resulted in greater separation between grey and white matter signal intensities than default excitation.
Conclusions: SC-UPs can improve excitation homogeneity in standard 3T systems without further calibration and could be used instead of a default excitation pulse for nonselective neuroimaging at 3T.
△ Less
Submitted 6 January, 2022;
originally announced January 2022.
-
The design, construction and performance of the MICE scintillating fibre trackers
Authors:
M. Ellis,
P. R. Hobson,
P. Kyberd,
J. J. Nebrensky,
A. Bross,
J. Fagan,
T. Fitzpatrick,
R. Flores,
R. Kubinski,
J. Krider,
R. Rucinski,
P. Rubinov,
C. Tolian,
T. L. Hart,
D. M. Kaplan,
W. Luebke,
B. Freemire,
M. Wojcik,
G. Barber,
D. Clark,
I. Clark,
P. J. Dornan,
A. Fish,
S. Greenwood,
R. Hare
, et al. (27 additional authors not shown)
Abstract:
Charged-particle tracking in the international Muon Ionisation Cooling Experiment (MICE) will be performed using two solenoidal spectrometers, each instrumented with a tracking detector based on 350 μm diameter scintillating fibres. The design and construction of the trackers is described along with the quality-assurance procedures, photon-detection system, readout electronics, reconstruction and…
▽ More
Charged-particle tracking in the international Muon Ionisation Cooling Experiment (MICE) will be performed using two solenoidal spectrometers, each instrumented with a tracking detector based on 350 μm diameter scintillating fibres. The design and construction of the trackers is described along with the quality-assurance procedures, photon-detection system, readout electronics, reconstruction and simulation software and the data-acquisition system. Finally, the performance of the MICE tracker, determined using cosmic rays, is presented.
△ Less
Submitted 11 July, 2010; v1 submitted 19 May, 2010;
originally announced May 2010.